Contactor de CA CHINT NXC-65A - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Contactor de CA CHINT NXC-65A - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

contactor/

Contactor de CA CHINT NXC-65A

  Model Segment Description NXC Product series code: Contactor de CA serie CHINT KunLun, upgraded replacement for traditional CJX2 series 65 Corriente operativa nominal: 65A (under AC-3, 400V) A Configuration code: Tipo estándar (no suffix = standard; suffix /N = reversing type) Common Suffix Coil voltage code: 220V / 380V / 110V / 24V, p.ej. NXC-65 ...

  • Detalles del producto

 

Segmento de modeloDescripción
NXCCódigo de serie del producto: Contactor de CA serie CHINT KunLun, upgraded replacement for traditional CJX2 series
65Corriente operativa nominal: 65A (under AC-3, 400V)
ACódigo de configuración: Tipo estándar (no suffix = standard; suffix /N = reversing type)
Common SuffixCódigo de voltaje de la bobina: 220V / 380V / 110V / 24V, p.ej. NXC-65 220V

Full Model Example:

NXC-65 220V 50Hz = CHINT KunLun 65A AC contactor, voltaje de la bobina 220V, 50Hz, configuración estándar

Typical Order No.: 710010100000281 (NXC-65 220V 50Hz, 1NO+1NC)

  1. Main Technical Data
CategoríaPresupuestoObservaciones
Información básica
Marca / SerieCHINT Electric / KunLun NXC SeriesCompact structure, direct replacement for CJX2-65
Tipo de producto3-phase AC ContactorFor frequent motor starting & remote circuit switching
Estándares de cumplimientoGB/T 14048.1 / CEI 60947-1, GB/T 14048.4 / CEI 60947-4-1International certified, safe and reliable
Electrical Data
Corriente de funcionamiento nominal (Es decir)65A (AC-3, 400V)Main contact rated current
Tensión de funcionamiento nominal (ue)380V / 400V (50Hz)Standard industrial grid voltage
Tensión nominal de aislamiento (interfaz de usuario)690VMax withstand voltage of insulation system
Tensión nominal de resistencia al impulso (árbitro)8kVOvervoltage protection capability
Control Coil VoltageOptional AC 24V / 36V / 110V / 220V / 380VSelected according to control system
Frecuencia de la bobina50 / 60HzGlobal grid compatibility
Rated Operating Frequency1200 cycles/h (AC-3)High frequent operation capability
Capacidad de ruptura10× rated currentShort-circuit withstand capability
Configuración de contacto
Contactos principales3NO (3-polo normalmente abierto)Standard for main power circuit
Contactos auxiliares1NO + 1CAROLINA DEL NORTEExpandable on request
Auxiliary Contact Rating5A / 220V yFor control signal circuits
Características físicas
Dimensiones (Ancho×Alto×Profundidad)90mm × 150mm × 105mmCompacto, space-saving
PesoAprox.. 0.8kilosLightweight for easy installation
MontajeCarril DIN estándar de 35 mm / montaje con tornillosSnap-on design, fast assembly
Clase de protecciónIP20Suitable for cabinet installation
Temperatura de funcionamiento-30℃ ~ +60℃Wide temperature range for harsh environments
Temperatura de almacenamiento-25℃ ~ +40℃Suitable for transportation & warehouse storage
Electromagnetic Performance
Coil PowerAprox.. 180Virginia (pick-up) / 25Virginia (tenencia)Low power consumption, ahorro de energía
Voltaje de caída30% ~ 70% of rated voltageReliable disconnection
Sistema electromagnéticoOptimized silicon steel lamination (32-piece core)Smooth closure, low noise & loss
Características de seguridad
CertificacionesCE, CCCDoméstico & international compliance
Arc ExtinctionMulti-channel magnetic blow-out arc suppressionHigh breaking performance
Funciones de protecciónsobrecorriente, calentamiento excesivo, undervoltage protectionComprehensive equipment & protección de circuito
  1. Accessory List
AccesorioModeloFunciónMounting Position
Auxiliary Contact BlockAX-3M/20 (2NO), AX-3M/02 (2CAROLINA DEL NORTE), AX-3M/11 (1NO+1NC)Expand auxiliary contacts for complex logicTop front
Time Delay ModuleF5-08 (0.1~30s), F5-11 (0.1~180s)On-delay / off-delay controlArriba
Surge SuppressorSR2-220, SR2-380Suppress coil surge voltageAbajo
Enclavamiento mecánicoNXC-ILPrevent phase short circuit for reversing contactor (NXC-65/N)Side
Mounting Rail35carril DIN estándar mmFixed installationInside control cabinet
Terminal Protection CoverStandard equippedAnti-touch protectionMain & auxiliary terminals
Mounting ScrewsM4×12mmScrew fixingBase mounting holes
Operation ManualElectrónico / hard copyInstalación, commissioning & maintenance guide
Coil ConnectorOpcionalFast coil wiring & reemplazoCoil terminal side
  1. Cross-Brand Equivalent & Reemplazo
MarcaSerieModeloCorriente nominalDiferenciasReplacement Compatibility
CHINTCJX2CJX2-651165AOld generation; NXC is fully upgraded versionDirect full replacement (same mounting size)
SchneiderTeSysDLC1D65M7C65AImport brand, higher cost, similar functionsAlto (verify mounting & contactos auxiliares)
siemens3RT3RT2026-1BB4065ADiseño modular, hot-swap supportMedio (different dimension & wiring)
TEJIDOAFAF65-30-1165AWide-voltage coil, global applicationMedio (needs position adjustment)
mitsubishiS-NS-N6565ACompact Japanese design, precio moderadoMedio (different terminal layout)
ChangshuCK3CK3-6565ADomestic equivalent, same performanceAlto (fully compatible size & montaje)
  1. Funciones principales & Aplicaciones

Funciones principales

  1. High-efficiency Electromagnetic System: Optimized core structure for stable closure, low noise and low energy consumption.
  2. Highly Reliable Arc Suppression: Magnetic blow-out technology with 10× rated breaking capacity for higher safety.
  3. Expansión flexible: Soporta contactos auxiliares, timer modules and surge suppressors for customized control.
  4. Fácil instalación: Snap-on DIN rail mounting for fast assembly and maintenance.
  5. Wide Temperature Adaptation: Stable operation from -30℃ to +60℃ for various industrial environments.

Aplicaciones típicas

  1. Control de motores: Frequent start/stop/reverse of 3-phase asynchronous motors (aprox. 30kW @ 400V).
  2. Automatización Industrial: Production lines, transportadores, fans, water pumps and general machinery.
  3. Electricidad del edificio: sistemas de climatización, fire water pumps, elevator auxiliary circuits.
  4. Machine Tools: Spindle control for milling machines, drilling machines and small machining centers.
  5. Power Distribution: Combined with thermal overload relays (Serie NR2) for complete motor protection starters.
  6. Notas complementarias
  7. Product Upgrade: The NXC KunLun series fully replaces the traditional CJX2 series with improved mechanical structure, electromagnetic performance and expandability.
  8. Directrices de selección:

Select current rating according to motor power (65A matches approx. 30kW motor).

Confirm coil voltage (220V / 380V most common).

Expand auxiliary contacts via AX series modules if signal points are insufficient.

  1. Consejos de mantenimiento:

Comprobar periódicamente el desgaste de los contactos; replace contacts when excessive contact resistance occurs.

Keep the contactor clean from dust and moisture.

Apply periodic energization (1–2 times monthly) for long-term idle equipment to prevent coil dampness.

CHINT Contactor Full Series List

  1. Product Series Overview
SeriePosicionamientoRango actualCaracterísticasReplacement Relation
NXCKunLun Main Series6A ~ 630ACompacto, modular, high cost-performanceFull replacement for CJX2
NC5High-performance Intelligent Series9A ~ 630ASmart control, ahorro de energía, alta estabilidadHigh-end alternative to NXC
CJX2Classic Traditional Series9A ~ 95AMature model, rentableGradually phased out by NXC
NXCFSlim Compact Series9A ~ 32AUltra-thin, space-savingSmall cabinet & compact installation
NC8Heavy-duty Industrial Series9A ~ 500AHigh mechanical life, strong arc resistanceFrequent start-stop working conditions
NXCCCapacitor Switching Contactor16A ~ 100AInrush current suppression, reactive power compensation dedicatedCapacitor bank control
NCH8Familiar & Building Series16A ~ 63AMiniature size, building automationIluminación, climatización & residential control
CJ40 / CJ20High-power Heavy Series100A ~ 630AHeavy-load design for large motorsHeavy industrial equipment
  1. NXC KunLun Series Main Model List (AC-3 400V)
Corriente nominalStandard ModelReversing ModelStandard Aux. ContactoMatched Motor PowerNúmero de pedido.
6ANXC-06METRO1NO+1NC0.75kilovatios710010100000276
9ANXC-09NXC-09/norte1NO+1NC1.5kilovatios710010100000277
12ANXC-12NXC-12/N1NO+1NC2.2kilovatios710010100000278
18ANXC-18NXC-18/N1NO+1NC3kilovatios710010100000279
25ANXC-25NXC-25/N1NO+1NC5.5kilovatios710010100000280
32ANXC-32NXC-32/N1NO+1NC7.5kilovatios710010100000281
40ANXC-40NXC-40/N1NO+1NC11kilovatios710010100000282
50ANXC-50NXC-50/N1NO+1NC15kilovatios710010100000283
65ANXC-65NXC-65/N1NO+1NC30kilovatios710010100000284
80ANXC-80NXC-80/N1NO+1NC37kilovatios710010100000285
95ANXC-95NXC-95/N1NO+1NC45kilovatios710010100000286
100ANXC-100NXC-100/N2NO+2NC55kilovatios710010100000287
120ANXC-120NXC-120/N2NO+2NC75kilovatios710010100000288
160ANXC-160NXC-160/N2NO+2NC90kilovatios710010100000289
200ANXC-200NXC-200/N2NO+2NC110kilovatios710010100000290
250ANXC-250NXC-250/N2NO+2NC132kilovatios710010100000291
315ANXC-315NXC-315/N2NO+2NC160kilovatios710010100000292
400ANXC-400NXC-400/N2NO+2NC200kilovatios710010100000293
500ANXC-500NXC-500/N2NO+2NC250kilovatios710010100000294
630ANXC-630ANXC-630A/N2NO+2NC315kilovatios710010100000295
  1. NC5 High-performance Series

Model Rule

NC5-[Actual][Tipo][Voltaje de la bobina]

– Tipo: Estándar / E=Economy / NE=Intelligent / F=Reversing

Rango actualEstándarInteligenteReversingAux. ContactoVoltaje de aislamiento
9A~38ANC5-09~38NC5NE-09~38NC5F-09~381NO+1NC690V
40A~100ANC5-40~100NC5NE-40~100NC5F-40~1001NO+1NC690V
115A~250ANC5-115~250NC5NE-115~250NC5F-115~2502NO+2NC1000V
315~630ANC5-315~630NC5NE-315~630NC5F-315~6302NO+2NC1000V
  1. Classic CJX2 Series
ActualModeloAux. ContactoMatched Motor
9ACJX2-0910 / 0901 / 09111NO / 1CAROLINA DEL NORTE / 1NO+1NC1.5kilovatios
12ACJX2-1210 / 1201 / 12111NO / 1CAROLINA DEL NORTE / 1NO+1NC2.2kilovatios
18ACJX2-1810 / 1801 / 18111NO / 1CAROLINA DEL NORTE / 1NO+1NC3kilovatios
25ACJX2-2510 / 2501 / 25111NO / 1CAROLINA DEL NORTE / 1NO+1NC5.5kilovatios
32ACJX2-3210 / 3201 / 32111NO / 1CAROLINA DEL NORTE / 1NO+1NC7.5kilovatios
40ACJX2-4010 / 4001 / 40111NO / 1CAROLINA DEL NORTE / 1NO+1NC11kilovatios
50ACJX2-5010 / 5001 / 50111NO / 1CAROLINA DEL NORTE / 1NO+1NC15kilovatios
65ACJX2-6510 / 6501 / 65111NO / 1CAROLINA DEL NORTE / 1NO+1NC30kilovatios
80ACJX2-8010 / 8001 / 80111NO / 1CAROLINA DEL NORTE / 1NO+1NC37kilovatios
95ACJX2-9510 / 9501 / 95111NO / 1CAROLINA DEL NORTE / 1NO+1NC45kilovatios
  1. Other Special Series

NXCF Slim Series

ActualModeloAnchoAux. Contacto
9ANXCF-0922.5milímetros1NO+1NC
12ANXCF-1222.5milímetros1NO+1NC
16ANXCF-1622.5milímetros1NO+1NC
25ANXCF-2536milímetros1NO+1NC
32ANXCF-3236milímetros1NO+1NC

NC8 Heavy-duty Series

ActualModelopolacosVida mecánica
9A~38ANC8-09~383PAG10 millones de ciclos
40A~100ANC8-40~1003PAG10 millones de ciclos
115A~500ANC8-115~5003P/4P8 millones de ciclos

NXCC Capacitor Contactor

ActualModeloSuppression TypeCapacitor Rating
16ANXCC-16Series resistor10kvar
25ANXCC-25Series resistor15kvar
32ANXCC-32Series resistor20kvar
40ANXCC-40Series resistor25kvar
50ANXCC-50Series resistor30kvar
63ANXCC-63Series resistor40kvar
80ANXCC-80Series resistor50kvar
100ANXCC-100Series resistor60kvar

NCH8 Building / Contactor doméstico

ModelopolacosActualSolicitud
NCH8-16M2PAG16ASmart home control
NCH8-25M2PAG25AAir conditioning control
NCH8-32M2PAG32ASmall water pump
NCH8-40M2PAG40AFloor heating system
NCH8-63M2PAG63ABuilding lighting
  1. Universal Accessories
AccesorioModeloApplicable Series
Auxiliary Contact BlockAX-3M SeriesNXC / NC5 / CJX2
Time Delay ModuleF5 SeriesFull series
Coil Surge SuppressorSR2 SeriesFull series
Enclavamiento mecánicoNXC-IL / NC5-ILReversing contactor
Relé de sobrecarga térmicaNR2 / NR5 SeriesMotor protection combination
35mm carril DINTipo estándarFull cabinet-mounted contactors
  1. Selección & Guía de reemplazo
  2. Series Selection

Nuevo proyecto: Adopt NXC KunLun series as priority.

Intelligent control: Choose NC5NE intelligent contactor.

Compact cabinet: Use ultra-thin NXCF.

Reactive power compensation: Special NXCC capacitor contactor.

  1. Selección actual

Rated current ≥ motor rated current × 1.1 (normal duty).

Frequent operation ≥ motor current × 1.25.

  1. Voltaje de la bobina

Match control circuit voltage: CA 220 V. / AC380V most common; safety low-voltage 24V/36V optional.

  1. Contactos auxiliares

Expandable via external auxiliary blocks when signal points are insufficient.

Reversing circuit must adopt mechanical interlock type.

Anterior:

Deja una respuesta

Dejar un mensaje