Leuze BCL22S-M312 Laser Barcode Scanner

(Eslogan, not Lenze) Nro. de orden: 50032097, BCL22 series fixed-mount 1D laser barcode scanner (line-scan type) Model Decoding `BCL 22 S M 312` BCL22: Serie de productos, industrial fixed barcode reader S: Single-line scanning M: High-speed version, 1000 scans per second (N version = 800 scans/s) 312: Optical variant, reading range 50-260 mm, barcode module 0.2-0.8 mm Key Technical ...

  • Detalles del producto

(Eslogan, no Lenz)

Nro. de orden: 50032097, BCL22 series fixed-mount 1D laser barcode scanner (line-scan type)

Decodificación de modelos

`BCL 22 S M 312`

BCL22: Serie de productos, industrial fixed barcode reader

S: Single-line scanning

METRO: High-speed version, 1000 scans per second (N version = 800 scans/s)

312: Optical variant, reading range 50-260 mm, barcode module 0.2-0.8 mm

Especificaciones técnicas clave

ArtículoEspecificación
Fuente de luz655 nm red laser, laser class 2
Scan Rate1000 scans/s
Reading Distance50 … 260 mm
Barcode Module0.2~0.8 mm
Supported BarcodesCode39/93/128, EAN‑UPC, Interleaved 2‑of‑5, Codabar, Pharmacode
Fuente de alimentaciónDC 10‑30 V, máximo. 310 mA
E/S2 entradas digitales / 2 salidas digitales, output max. 700 mA
Interfaces de comunicaciónRS232 process port, RS232 service configuration port; 15‑pin male Sub‑D
Protección de ingresoIP65
Dimensiones68 × 82 × 28 mm, weight 370 g
Temperatura de funcionamiento0~+40℃, storage ‑20~+60℃

Solicitud

Conveyor line barcode reading, clasificación logística, maquinaria de embalaje, production-line part identification, warehouse automation. Supports Auto-Config automatic setup, external trigger reading, multi-code reading (arriba a 63 codes).

Interfaces & Accesorios

15-pin male Sub-D connector; matching cable: KD BCL 2. MA30/MA31 modules extend Leuze multiNet-plus RS485 bus networking.

Reemplazo / Modelos compatibles

  1. BCL22-SM312 (identical original part)
  2. BCL22-SN312: N-variant, 800 scans/s, identical optics
  3. Alternativa de actualización: BCL348i SM 100 (new-generation, supports RS232/422/485 and Ethernet)

Common Fault Points & Used-Unit Inspection Checklist

  1. Polygon mirror motor aging: ruido anormal, intermittent decode failures, stationary laser scan line
  2. Oxidation or broken wires at 15-pin Sub-D connector
  3. Scratched laser window leading to unstable decoding
  4. Damaged I/O output channels caused by over-current

Nota: This device is manufactured by Leuze. Lenze is a drives brand; the two are frequently confused.

BCL22S-M312 (Eslogan) 15-Pin Male Sub-D Pinout

Device side: 15-pin male Sub-D. MA2 / MA4 connection modules are strongly recommended; direct crimping of Sub-D plugs is not advised. Power supply DC10-30 V; I/O is PNP output, inputs active-high.

AlfilerSeñalDescripción
1SW‑IN1Digital Input 1: external scan trigger
2SW‑IN2Digital Input 2: auxiliary function (reiniciar / barcode gate)
3SW‑OUT2Switch Output 2: decode success / status signal
4SW‑OUT1Switch Output 1: barcode read valid signal
5GND_SAI/O output ground
6VDD_INMain power positive DC10‑30 V
7GND_INMain power 0 V reference
8educación físicaTierra protectora; must connect to chassis ground for noise immunity
9RXD‑PROProcess‑port RS232‑RXD (scanner receive)
10TXD‑PROProcess‑port RS232‑TXD (scanner transmit barcode data)
11-Reservado, do not connect
12-Reservado, do not connect
13-Reservado, do not connect
14-Reservado, do not connect
15-Reservado, do not connect

Notas de cableado

  1. Comunicación: Barcode data uses pins 9/10 RS232 process port. The 9-pin service configuration port resides on the MA wiring module and is not present on the 15-pin connector.
  2. Modo de disparo: Apply 24 V high level to SW-IN1 for one-shot trigger; 0 V stops scanning.
  3. Salidas: SW-OUT1 / 2 are PNP, output voltage equals supply VDD_IN, máximo. 700 mA. When connecting to PLC inputs, tie PLC common terminal to 0 V.
  4. MA2 / MA4 original modules are highly recommended. Home-brewed 15-Sub-D cables frequently cause communication instability and noise-related data loss.
  5. Always connect PE protective earth. Un-grounded units on conveyor systems suffer garbled data and false triggering.

Matching Cable Part-Numbers

KD BCL2: Standard cable with power, I/O and RS232 signals, typical lengths 3 m / 5 metro; Order No. 50036410.

MA30 / MA31: MultiNet-Plus bus modules for RS485 multi-scanner networking.

Direct Replacement Comparison

BCL22S-M312: single-line laser scanner, 1000 scans/s, reading range 50-260 mm, barcode module 0.2-0.8 mm, RS232, 2-en / 2-afuera, IP65, for high-speed conveyor-line 1D barcode acquisition.

Imported Upgrade Replacements (project-level drop-in compatible, configuration reuse)

  1. BCL348i SM 100

Optical range 50-280 mm, 1000 Hz scan rate; adds TCP-IP Ethernet while retaining RS232, 2-en / 2-out I/O. Preferred upgrade for BCL22 series retrofits; Order No. 50124782.

Nota: mounting hole pattern differs; custom adapter bracket required.

  1. BCL22-SM312: Exact original spare-part replacement, Order No. 50032097.

Domestic Alternative Scanners (for production-line retrofits)

Domestic ModelEspecificaciones claveObservaciones
Newland NLS‑FS500‑1DSingle‑line laser, 50‑300 mm, 1000 scans/s; RS232, 2IN/2OUT; IP65Conveyor‑line 1D reading; output format can emulate Leuze protocol, rentable
Hikrobot MV‑ID2000‑LSingle‑line laser, large depth‑of‑field; RS232/Ethernet configurable I/OFor new projects requiring direct MES Ethernet upload

Nota: Domestic alternatives have different mechanical mounting dimensions. Serial protocol frames require commissioning; true plug-and-play is not possible. For legacy production-line spare-parts, prefer the BCL348i SM100.

Practical Used-Unit Test Procedure for BCL22

  1. Power-on and listen to polygon motor: steady low hum is normal. Rattling, jitter or stationary scan line indicates motor failure; repair costs are high, avoid purchasing such units.
  2. Inspect laser window for scratches or haze; scratches cause partial-field decode failures.
  3. I/O test: apply 24 V trigger to IN1; OUT1 must assert 24 V upon successful decode. Absent output indicates burnt output transistor.
  4. RS232 loop-back test by shorting TXD/RXD. Verify no broken conductors or bent / oxidized pins inside the 15-pin connector.
  5. Barcode read test using 0.3-0.5 mm module barcode across full 50-260 mm working range. Frequent failures at nearor far-range indicate degraded optics.

BCL22S-M312 Scan Frequency

1000 scans per second (1000 scans/s)

M = high-speed variant: 1000 Hz

Sibling N-variant (BCL22S-N312): 800 scans/s

Suplementario: Polygon-mirror single-line laser delivers 1000 scan lines per second, suited for high-speed conveyor lines.

Optical version 312: reading range 50-260 mm, barcode module 0.2-0.8 mm.

BCL22S-M312 ↔ S7-200 SMART RS232 Wiring

⚠️ The native S7-200 SMART port is RS485 and cannot connect directly to RS232 scanner. SB CM01 signal board is mandatory, configured for RS232 mode, using Free-Port communication to receive barcode strings.

For BCL22 15-Sub-D male connector: MA2 / MA4 wiring modules are strongly recommended; avoid direct soldering to Sub-D plugs.

Hardware Cross-Wiring (3-wire RS232, no hardware handshaking)

BCL22 (15‑Pin Sub‑D) AlfilerSignal DescriptionSB‑CM01 Terminal
Pin10 TXD‑PRO (Scanner Transmit)Barcode data output from scannerTerminal 4 RxA (PLC Receive)
Pin9 RXD‑PRO (Scanner Receive)Commands sent to scannerTerminal 1 TxB (PLC Transmit)
Pin7 GND_IN (Tierra eléctrica)RS232 signal reference groundTerminal 3 M (PLC logic ground)

Rule of thumb: Scanner TX connects to PLC RX; scanner RX connects to PLC TX; common ground is mandatory. Missing ground leads to garbled characters and dropped data.

Fuerza & I/O Wiring (external-trigger mode, typical factory setup)

BCL22 power supply:

Pin6 VDD_IN: DC24 V positive

Pin7 GND_IN: 24 V return / 0 V

Pin8 PE: protective earth, connect chassis to ground for noise suppression

External scan trigger:

SW-IN1 (Pin1): driven by PLC digital output; 24 V high-level triggers scan, 0 V stops.

SW-OUT1 (Pin3): PNP output asserts 24 V on successful decode; wired to PLC digital input.

SB-CM01 System-Block Configuration (Micro/WIN SMART)

  1. System Block → SB CM01, communication mode select: RS232
  2. BCL22 factory-default serial parameters:

velocidad en baudios: 9600

bits de datos: 8, bits de parada: 1, Paridad: None

  1. PLC Port 1 (SB-CM01) set to Free-Port mode; SMB130 = 1600 (9600, 8-N-1 Free-Port).

Register note: SB-CM01 maps to Port 1. Free-Port control byte SMB130. Receive buffer uses SMB134-SMB141. RCV instruction targets Port 1, do not use Port 0 (on-board RS485).

BCL22 Scanner Parameter Setup (Leuze-Config software)

  1. Modo de salida: trigger-based reading; transmit barcode string automatically upon successful decode, suffix CR(0D) or CR+LF(0D0A).
  2. Disable XON/XOFF software flow-control; disable RTS/CTS hardware handshaking.
  3. Trigger source: rising edge on external IN1 for single-shot scan.
  4. Output format: transmit barcode payload only, no extra protocol headers.

PLC Free-Port Receive Logic

Use RCV instruction; define carriage-return CR (160D) as message end delimiter.

Upon complete receipt of barcode string, copy buffer contents to VB memory area; re-arm RCV instruction for next acquisition.

Timeout-only termination is discouraged. BCL22 appends CR character to every output string; frame delimiter is far more reliable.

Field Troubleshooting

  1. Garbled characters: missing common ground; baud-rate / parity mismatch; cable shield grounding at both ends.
  2. No data received: TX/RX swapped; download RS232 system-block configuration and power-cycle PLC to activate SB-CM01.
  3. I/O trigger does not start scanning: IN1 needs valid 24 V high level; scanner internal parameter must enable external-trigger mode.
  4. Longitud del cable >15 metro: RS232 is unsuitable for long distances. Use MA31 module for MultiNet-Plus RS485 bus extension.

Fall-back without SB-CM01

Native Port 0 is RS485. Fit an active RS232-RS485 converter. RS232 side connects to BCL22; converter RS485 side connects to PLC Port 0 terminals 3 & 8. Configure Port 0 for Free-Port. Para entornos industriales, SB-CM01 solution is preferred; converters incur higher noise-error risk