OMRON E8F2-A01 Digital Pressure Sensor

Estado: Interrumpido (End of Order) in Sep 2024. Only stock / used units available. New projects require alternative models. Serie: E8F2 Mini Cube Digital Pressure Sensor, Gauge Pressure, Positive Pressure, NPN Output ✅ Model Code Explanation E8F2: Serie, LED digital display pressure sensor A: Measuring range 0~100 kPa (positive pressure) 01: 100kPa specification C: PNP ...

  • Detalles del producto

Estado: Interrumpido (End of Order) in Sep 2024. Only stock / used units available. New projects require alternative models.

Serie: E8F2 Mini Cube Digital Pressure Sensor, Gauge Pressure, Positive Pressure, NPN Output

✅ Model Code Explanation

E8F2: Serie, LED digital display pressure sensor

A: Measuring range 0~100 kPa (positive pressure)

01: 100kPa specification

do: NPN open collector output; B = PNP version (E8F2-A01B)

📌 Key Specifications

ArtículoParámetro
Tipo de presiónGauge Pressure
Rated Range0~100kPa (0~14.5 psi)
Presión de prueba400 kPa
Medios aplicablesNon-corrosive, non-flammable gas (compressed air, etc.)
Fuente de alimentaciónDC12~24V ±10%, ripple p-p ≤10%
Max Current Consumption≤70mA
Producción2-channel independent NPN open collector switch output + 1~5V linear analog output (output impedance 1kΩ)
Switch Output LoadMax 30mA, external voltage ≤DC30V
Tiempo de respuesta≤5 ms (switch output)
ExactitudRepeatability ±1%FS; Linearity ±1%FS; Display accuracy ±3%FS±1 digit
Operation ModesHysteresis mode / Window mode / Auto-teach
Mostrar3.5-digit red LED + green bar graph, orange LED for OUT status
Puerto de presiónR(PT)1/8 taper thread + M5 internal thread dual port
CablePre-wired cable, standard length 2m
Clasificación del gabineteIP50
Temperatura de funcionamiento0~+55℃ (sin glaseado); Storage -10~60℃
Dimensión28×28×29mm, Weight approx.110g
ProtecciónProtección contra polaridad inversa, protección contra cortocircuitos de carga

🧩 Application Scenarios

Pneumatic pressure detection, vacuum adsorption (this model is positive pressure; select E8F2-AN0C for negative pressure), fixture pressure confirmation, air source pressure monitoring, pressure judgment in semiconductor/electronics production, OK/NG pressure judgment with PLC.

⚠️ Alternative Selection Recommendation (New Projects)

E8F2 discontinued. OMRON recommends next-generation E8CC series for replacement with same range 0~100kPa NPN digital pressure sensor.

Replacement checkpoints: pressure port, NPN output type, 1~5V analog signal, soporte de montaje, wiring definition.

🛠️ Accessories

E89-F3: Mounting bracket included with main unit

E89-F4: Panel mount bracket (se vende por separado)

📎 HS Code Reference (Customs Declaration)

90262090 Sensor de presión (for gas pressure measurement)

🔍 Inspection Checklist for Used Units

  1. Apariencia: No cracks on housing, no corrosion at pressure port, funda de cable intacta
  2. Power-on test: LED digits and bar graph display normally, no garbled characters
  3. Zero-point reset function test
  4. Pressure calibration: Connect adjustable air source, verify readings and 1~5V analog output
  5. Operation test of 2 OUT switch outputs, hysteresis/window mode switching
  6. Insulation and short-circuit protection test

Tabla comparativa: E8F2-A01C (Original) vs E8CC-A01C (Official Recommended Replacement)

Nota importante: E8FC is flow sensor and cannot replace E8F2 pressure sensor. The official direct replacement for E8F2-A01C is E8CC-A01C (0~100kPa, PNP, 2cable m). E8CC pressure sensor and E8FC flow sensor are frequently confused.

Artículo de comparaciónE8F2-A01C (Interrumpido)E8CC-A01C (Reemplazo recomendado)Replacement Remarks
Tipo de productoMini Cube Digital Pressure SensorSlim Digital Pressure SensorBoth gauge pressure, 0~100kPa positive pressure for gas measurement
Rango de medición0~100kPa (Indicador)0~98 kPa (≈0~100kPa, Indicador)Equivalent for engineering application
Puerto de presiónR(PT)1/8 taper thread + M5 internal thread dual portR(PT)1/8 taper thread + M5 internal thread dual portThread identical, no air tube modification required
Fuente de alimentaciónDC12~24V ±10%DC12~24V ±10%Power supply compatible
Configuración de salida2-channel NPN open collector switch + 1~5V analog voltage2-channel NPN open collector switch + 1~5V analog voltageSame signal type
Analog Output Spec1~5V, output impedance 1kΩ, load ≥500kΩ1~5V, output impedance 20Ω, load ≥10kΩE8CC analog output has stronger drive capability, no PLC analog input modification
Switch Output LoadMax 30mA per channelMax 80mA per channelE8CC has larger current margin
Tiempo de respuesta≤5 ms (switch output)≤5 ms (switch output)Same response speed
ExactitudRepeatability±1%FS; Linearity±1%FS; Display ±3%FS±1 digitRepeatability±1%FS; Linearity±1%FS; Display ±3%FS±1 digitSame accuracy specifications
Operation ModesHistéresis / Ventana / Auto-teachHistéresis / Ventana / Auto-teachIdentical menu logic
Clasificación del gabineteIP50IP50Only for dry cabinet installation, no impermeable
Tipo de cablePre-wired 2m cablePre-wired 2m cableWiring color definition differs, do not directly match wires
Mostrar3.5-digit red LED + bar graph2.5-digit LCDDifferent display hardware, misma funcion
Presión de prueba400kPa490kPaE8CC higher proof pressure, seguridad mejorada
Temperatura de funcionamiento0~+55℃ (sin glaseado)−10~+55℃E8CC better low-temperature tolerance
PesoApprox.110gApprox.80gE8CC lighter, different outline; mounting bracket must be replaced
Medios aplicablesNon-corrosive, non-flammable gas (compressed air)Non-corrosive, non-flammable gas (compressed air)Suitable for pneumatic adsorption & air source pressure monitoring
EstadoInterrumpido 2024, stock / used onlyInterrumpido, limited stock; E8PE recommended for new projectsE8CC also phasing out; select E8PE for new machine design

Replacement Implementation Guide

✅ No air tube change, no PLC program modification. Only replace mounting bracket, re-set pressure threshold and zero calibration after power on.

⚠️ E8CC slim strip housing vs E8F2 cube housing. Mounting hole incompatible, original E89-F3 bracket cannot be reused. Use dedicated E8CC bracket.

Long-term Alternative for New Projects (E8PE Series)

When E8CC stock is exhausted, E8PE-B01C (0~100kPa, PNP, conector M12, Enlace IO, IP67) is recommended for new machines.

Diferencias: M12 connector instead of pre-wired cable; analog output changed to 4-20mA, PLC analog wiring adjustment required. Prioritize E8CC-A01C for direct retrofit of existing equipment.

Common Pitfall Reminder

E8FC is liquid flow sensor (for cooling water / oil flow + medición de temperatura), NOT pressure sensor. Do not confuse E8CC pressure sensor and E8FC flow sensor during model selection.

Accuracy Parameters from OMRON Original Datasheet: E8F2-A01C vs E8CC-A01C

FS = Full Scale

Accuracy ItemE8F2-A01C (0~100kPa)E8CC-A01C (0~98kPa)
Switch Repeatability (ENCENDIDO/APAGADO)±1%FS max±1%FS max
Linealidad (1~5V analog)±1%FS max±1%FS max
Total Analog Output Accuracy1~5V output: ±5%FS maxAnalog output accuracy: ±3%FS max
Display Accuracy±3%FS ±1 digit (0~55℃ full temp range)0~50℃±3%FS ±1 digit
50~55℃±4%FS ±1 digit
-10~0℃±5%FS ±1 digit
Histéresis (Switch dead band)Adjustable built-in hysteresis≤2%FS

Brief Explanation

  1. Switch judgment (OK/NG):Both have identical repeatability. Accuracy difference negligible for pneumatic pressure threshold replacement.
  2. Analog acquisition (PLC AD input):E8CC analog output has better overall accuracy (±3%FS vs E8F2 ±5%FS).
  3. Display readingIdentical specification at ambient 25℃. E8CC error increases at low temperature or near 55℃ high temperature.
  4. Minor range difference: E8F2 0~~100kPa; E8CC 0~~98kPa, acceptable equivalent in engineering.

Output Signal Comparison Table: E8F2-A01C vs E8CC-A01C

Both have identical output configuration: 2-channel independent NPN switch + 1 channel 1~5V analog voltage signal. No PLC interface modification required for retrofit.

ArtículoE8F2-A01CE8CC-A01CReplacement Remarks
Salida del interruptor2-channel independent NPN open collector. NO/NC configurable; Histéresis / Ventana / Auto-teach supported2-channel independent NPN open collector. NO/NC configurable; Histéresis / Ventana / Auto-teach supportedSame logic function
Max load current per switch channel30mamá80mamáE8CC higher load capacity
Linear Analog Output1~5V voltage signal (1V@0kPa, 5V@full scale)1~5V voltage signal (1V@0kPa, 5V@full scale)Same voltage level; E8CC low output impedance, compatible with standard PLC analog input
Output impedance:1kΩOutput impedance:20Oh
Minimum load resistance ≥500kΩMinimum load resistance ≥10kΩ
Switch response time≤5 ms≤5 msSame speed
Cable color assignmentMarrón: Power+, Azul: 0V, Negro: SALIDA1, Blanco: OUT2, Gris:1~5V AnalogMarrón: Power+, Azul:0V, Negro:1~5V Analog, Blanco:AFUERA⚠️ Wire color definition different! Do not hard connect by matching colors only
Communication OutputNingunoNingunoNo RS485 / IO-Link for both

Key Summary

✅ Same signal types: 2-channel NPN switch + 1~5V analog voltage, no PLC program change needed.

⚠️ Different wire color mapping, most common field replacement error point.

✅ Analog is voltage output, NOT 4-20mA current signal.

Anterior: