Pilz 773400-PNOZ-MI1P Safety Input Expansion Module - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Pilz 773400-PNOZ-MI1P Safety Input Expansion Module - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

eléctrico/

Pilz 773400-PNOZ-MI1P Safety Input Expansion Module

Pilz 773400-PNOZ-MI1P Safety Input Expansion Module The Pilz 773400-PNOZ-MI1P is an 8-channel 24VDC safety digital input expansion module belonging to the PNOZmulti Classic product range. It provides I/O expansion for the PNOZmulti safety control system and supports safety functions such as emergency stop, safety gate monitoring and two-hand control. Complying with PLd per EN ISO ...

  • Detalles del producto

Pilz 773400-PNOZ-MI1P Safety Input Expansion Module

El Champiñón 773400-PNOZ-MI1P is an 8-channel 24VDC safety digital input expansion module belonging to the PNOZmulti Classic product range. It provides I/O expansion for the PNOZmulti safety control system and supports safety functions such as emergency stop, safety gate monitoring and two-hand control. Complying with PLd per EN ISO 13849-1 and SIL CL 2 per EN/IEC 62061, it is designed for industrial automation applications requiring high-safety-level signal acquisition. Este producto ha sido descontinuado., and corresponding modules from the PNOZmulti 2 series are recommended as replacements.

  1. Definición del código del modelo
Segmento de códigoDefiniciónDescripción detallada
773400Código de pedidoUnique official Pilz part number for ordering and inventory management
PNOZSeries PrefixCore identifier for Pilz safety relay and safety control product line
MITipo de móduloSafety Digital Input Module (M-Series Input), differentiated from MO (Producción) and MC (E/S mixtas)
1Channel SpecStandard 8-input variant (1 = 8 canales, 2 = 16 canales)
PAGVersion CodePNOZmulti Classic edition, distinguished from Series 2 (new-generation PNOZmulti 2)

Nota: This is an expansion module for PNOZmulti Classic and must be used together with compatible base units (p.ej. PNOZ m1p); standalone operation is not supported.

  1. Especificaciones técnicas básicas
CategoríaEspecificaciónObservaciones
Características básicas
Channel Count8 safety digital input channelsConfigurable for single-channel or dual-channel safety circuit logic
Tipo de entrada24VDC discrete inputCumple con EN 61131-2 Tipo 1; compatible with PNP / NPN sensors
Input PolarityPositive/Negative Logic configurableParameterized via PNOZmulti Configurator software
Corriente de entradaAprox.. 5mA per channelLow-power design to reduce load on field sensors
Parámetros eléctricos
Voltaje de funcionamiento20.4~28.8VDC (nominal 24VDC)Powered from base unit via internal backplane bus
Input Signal LevelOFF-state: -3~+5VDC; ON-state:19.2~30VDCWide voltage tolerance against field supply fluctuation
Test Pulse FunctionBuilt-in test pulse outputDetects short-circuit across input contacts to elevate safety integrity
Isolation RatingNo inter-channel isolation; isolation between module and backplaneDielectric withstand: 250Vrms
Tiempo de respuesta≤10ms (factory default setup)Fast safety reaction for emergency stop and safety interlock
Certificaciones de seguridad
Safety RatingEN ISO 13849-1 PLd; ES/CEI 62061 SIL CL 2For medium-risk machinery safety applications
Approved CertificatesCE, Reino Unido, cULus, KOSHA, CAO (TÜV certified)Meets global mainstream market safety compliance
Datos ambientales
Temperatura de funcionamiento.0℃ ~ 60 ℃Standard industrial ambient range
Storage Temp.-25℃ ~ 70 ℃Tolerates harsh transportation & storage conditions
Humedad relativa93%RH @40℃, sin condensaciónExtended humidity resistance
Protección de ingresoIP20For cabinet indoor installation only
Mecánico & Montaje
Dimensiones94(h)×22.5(W.)×121(D) milímetrosStandard DIN rail footprint
Peso~120g (without terminals), ~138g (con terminales)Lightweight to minimize DIN rail load
MontajeHorizontal installation on 35×7.5mm EN 50022 standard DIN railConvenient system expansion and integration
Tipo de terminalOptional spring-cage plug-in terminals / terminales de tornilloFast field wiring and maintenance

III. Full Product Lineup (PNOZmulti Classic Input Expansion Modules)

ModeloChannel QtyInput SpecCaracterística especialNúmero de pedido.Lifecycle Status
PNOZ MI1P824VDC Safety DIStandard non-coated version773400Interrumpido
PNOZ MI1P C824VDC Safety DIConformal coated for harsh ambient773405Interrumpido
PNOZ MI2P1624VDC Safety DI16-channel extended model773410Interrumpido
PNOZ MI2P C1624VDC Safety DI16-channel coated variant773415Interrumpido
PNOZ MI4P424VDC Safety DICompact 4-channel type773420Interrumpido
  1. Reemplazo & Comparación entre marcas
  2. Internal Pilz Alternatives
Original PNReplacement PNReason for ReplacementNota de compatibilidad
773400-PNOZ-MI1P774700-PNOZ m2p mi1pNew upgrade to PNOZmulti 2 platformRequires PNOZmulti 2 base unit + full program reconfiguration
773400-PNOZ-MI1P774705-PNOZ m2p mi1p CCoated version for corrosive environmentRequires PNOZmulti 2 base unit + full program reconfiguration
773400-PNOZ-MI1P773405-PNOZ MI1P CConformal coating addedDrop-in compatible with original PNOZmulti Classic base unit
  1. Competitor Cross Reference
Pilz PartEquivalente SiemensSchneider EquivalentEquivalente de OmronDiferencias fundamentales
773400-PNOZ-MI1P3RK1304-0CB00-0AA2140SAI73400G9SA-501Champiñón: Built-in safety test pulse, PLd/SIL2
siemens: PROFIsafe fieldbus, PLd/SIL3
Schneider: Quantum safety I/O, PLd/SIL2
Omrón: Standalone safety relay, PLc/SIL1
  1. Campos de aplicación & Casos de la industria
  2. Escenarios de aplicación recomendados

Fabricación de automóviles

Body Welding Line: Signal collection for E-stop pushbuttons, safety gate limit switches and two-hand control devices

Final Assembly Line: Connection for safety light curtains, safety mats and robot perimeter protection signals

Coating Workshop: Interlock input for explosion-proof doors and flammable gas detection alarms

Máquina herramienta & Machining

CNC Machine: Safe spindle stop, tool-change safety interlock and workpiece clamping confirmation signals

Prensa & Bending Equipment: Mould safety gate, two-hand start button and slide stroke limit monitoring

Automated Conveying Line: Conveyor safety interlock and personnel access detection

Alimento & Bebida / Embalaje

High-speed Packaging Machine: Safety door switches, emergency stop and overload protection signals

Food Processing Line: Wash zone interlock and sterilizer safety gate status monitoring

Filling Equipment: Bottle/can in-position detection and protective door interlock

Logística & Warehouse Automation

Automated AS/RS: Stacker crane limit switches, E-stop and walk-in access detection

Conveyor System: Line emergency stop, safety gate and overload fault input

Robotic Sorting Line: Robot cell guarding and safety light curtain signal acquisition

  1. Not Recommended Applications

Standalone operation: Mandatory pairing with PNOZmulti Classic base unit; cannot run independently

High safety requirement (pl y / SIL3): Select PNOZmulti 2 or higher-grade safety modules instead

Outdoor exposed installation: IP20 rated only for cabinet mounting

AC signal input: Module exclusively for 24VDC; dedicated AC input modules required for AC field signals

  1. Caso de aplicación típico

Project Title: Safety Retrofit for Automotive Component Stamping Line

Bill of Material: 1×PNOZ m1p base unit + 2×PNOZ MI1P (773400) + 1×PNOZ MO1P output module + PNOZmulti Configurator

Beneficios de la aplicación:

  1. Monitors 8 safety gate limits, 4 emergency stops and 2 two-hand control signals
  2. Redundant safety circuit design fulfilling EN ISO 13849-1 PLd specification
  3. Onboard test pulse automatically diagnoses input contact short-circuit to improve system reliability
  4. Integrated diagnostics cut unplanned downtime by 40% and enable rapid fault pinpointing for safety loops
  5. Guía de solución de problemas
Síntoma de fallaCausa principalPasos de inspecciónRemedial Action
Module dead, all LEDs off1.Base unit power failure1.Check base unit power LED1.Repair base unit power supply
2.Poor backplane connection2.Unplug and re-seat module2.Fix module locking position
3.Internal hardware damage3.Replace with spare module3.Install replacement module
Partial channels no input1.Error de cableado1.Verify wiring against schematic1.Correct field wiring
2.Field sensor defective2.Measure sensor output via multimeter2.Replace faulty sensor
3.Incorrect test pulse setup3.Check test pulse parameter in Configurator3.Config test pulse (only for dry contacts)
4.Burned input channel4.Test with known-good sensor4.Swap to spare channel or replace module
Spurious safety trip1.EMI interference1.Check shielding & earthing1.Reroute cable & add shielding
2.Unstable supply voltage2.Measure input DC 19.2~30V range2.Add power filter for stable supply
3.Loose terminal wiring3.Tighten all screw terminals3.Re-terminate loose wiring
4.Test pulse cross-interference4.Adjust/disable test pulse (for active sensors only)4.Optimize test pulse configuration
Permanent fault LED ON1.Safety circuit fault1.Inspect safety loop wiring1.Remediate faulty safety wiring
2.Backplane communication loss2.Check inter-module bus connection2.Restore bus connection
3.Invalid project configuration3.Download corrected configuration3.Re-program and download project

VII. Directrices de selección & Referencia rápida

Mnemónico de selección

Eight-channel safety DI MI1P, 24VDC PNOZ expansion piece;

PLd safety grade, test pulse stops short-circuit disease;

Auto, machine, packaging cabinet-mounted IP20 lease;

Classic discontinued, upgrade to m2p series.

Quick Rules

  1. Model Decoding:773400 = PNOZ MI1P; PNOZ=Safety Series; MI=Input; 1=8CH; P=Classic Version
  2. Core Spec Shortcut:8CH /24VDC /PLd SIL2 /Built-in Test Pulse /IP20 /DIN Rail Mount
  3. Guía de reemplazo:Upgrade → PNOZmulti2; Harsh environment → Coated C version; Same platform → Classic coated spare
  4. Application Filter:Safety DI + Medium risk + Cabinet installation = PNOZ MI1P applicable

VIII. Información de pedido & Accesorios

Standard Part No.:773400-PNOZ-MI1P (8-channel safety input module)

Conformal Coated Variant:773405-PNOZ-MI1P C

Repuestos recomendados:

783400: PNOZmulti Spring Terminal Kit (fits MI1P/MI2P/MO1P)

793400: PNOZmulti Screw Terminal Kit (fits MI1P/MI2P/MO1P)

779110: PNOZmulti Bus Terminator (mandatory for multi-module expansion setup)