Explicación del código del modelo
| Segmento de código | Significado | Descripción detallada |
| LC1 | Product series identifier | Basic code for Schneider TeSys contactors |
| D | código de serie | TeSys Deca series, high-performance full-range industrial contactors |
| 25 | Corriente nominal | 25A (rated operational current under AC-3 utilization category) |
| 6 | Coil characteristic | Low-power consumption coil (<2.4W.), diseño de ahorro de energía |
| B | voltaje de la bobina | 24V |
| l | Coil type | bobina de CC |
| Full Description | Three-pole contactor of Schneider TeSys Deca series, rated current 25A, 24VDC low-power coil, ring terminal connection, 1Contactos auxiliares NA+1NC |
- Especificaciones técnicas principales
| Categoría | Datos técnicos | Observaciones |
| Parámetros básicos | ||
| Tipo de producto | 3-pole non-reversible contactor | 3 main NO contacts |
| Corriente nominal (AC-3) | 25A @ 400V | For controlling 11kW three-phase motors |
| Corriente nominal (AC-1) | 40A @ 400V | Para cargas resistivas |
| Tensión operativa nominal | máx.. 690VACACIONES / máx.. 300VCC | |
| Coil Specification | 24VCC, Baja potencia (≤2.4W) | voltaje de entrada: 19.2-30VCC |
| Mecánico & Resistencia eléctrica | ||
| Vida mecánica | 15,000,000 ciclos (no load) | |
| Vida eléctrica (AC-3) | 1,600,000 ciclos (with load) | |
| Physical Features | ||
| Tipo de montaje | Montaje en carril DIN estándar de 35 mm | |
| Tipo de conexión | Ring-lugs | For firm wiring |
| Contactos auxiliares | 1NO+1NC (estándar) | Expandable |
| Dimensiones (milímetros) | Aprox.. 45×85×101 | Tamaño compacto, ahorra espacio en el gabinete |
| Certificaciones & Estándares | CEI 60947-4-1, EN 60947-4-1, Cumple con RoHS | Comply with international industrial standards |
| Entorno operativo | ||
| Temperatura de funcionamiento | -25°C ~ +70°C | Wide temperature range for harsh industrial environments |
| Temperatura de almacenamiento | -40°C ~ +85°C | |
| Protección de ingreso | IP20 (unidad principal) | Use with qualified protective enclosures |
- Full Model List (LC1D Series, 25A Range)
| Modelo | Voltaje de la bobina | Tipo de bobina | Consumo de energía de la bobina | Contactos auxiliares | Reference Order No. |
| LC1D256BL | 24VCC | corriente continua | Baja potencia (<2.4W.) | 1NO+1NC | LC1D256BL |
| LC1D256B7 | 24VACACIONES | C.A. | Baja potencia | 1NO+1NC | LC1D256B7 |
| LC1D2501BL | 24VCC | corriente continua | Standard power | 1NO+1NC | LC1D2501BL |
| LC1D2501B7 | 24VACACIONES | C.A. | Standard power | 1NO+1NC | LC1D2501B7 |
| LC1D2510BL | 24VCC | corriente continua | Standard power | 1NC+1NO | LC1D2510BL |
| LC1D2510B7 | 24VACACIONES | C.A. | Standard power | 1NC+1NO | LC1D2510B7 |
| LC1D25BD | 24VCC | corriente continua | Standard power | 1NO+1NC | LC1D25BD |
| LC1D25M7 | 220VACACIONES | C.A. | Standard power | 1NO+1NC | LC1D25M7 |
| LC1D25Q7 | 380VACACIONES | C.A. | Standard power | 1NO+1NC | LC1D25Q7 |
| LC1DT256BL | 24VCC | corriente continua | Baja potencia | 1NO+1NC (4-polo) | LC1DT256BL |
- Marca cruzada & Old/New Model Replacement List
4.1 In-brand Replacement (Schneider)
| Modelo Original | Modelo de reemplazo | Descripción |
| LC1D25BD | LC1D256BL | Upgraded to low-power coil, 24VDC retained with improved performance |
| LC1D25B7 | LC1D256B7 | Low-power AC coil version |
| LC1D2500BL | LC1D256BL | Optimized auxiliary contacts (1NO+1NC replaces 0NO+0NC) |
4.2 Reemplazo entre marcas
| Original Brand | Modelo Original | Schneider Equivalent | Matching Level | Observaciones |
| TEJIDO | A26-30-10 | LC1D256BL | ★★★★★ | 3-polo 25A, 24V coil, identical specifications |
| siemens | 3RT6026-1AN20 | LC1D256BL | ★★★★☆ | 25A, 24VCC, Misma configuración de contacto auxiliar. |
| Omrón | GMC-25 | LC1D256BL | ★★★★☆ | 3-polo 25A, 24VCC, equivalent mechanical life |
| mitsubishi | S-N25 | LC1D256BL | ★★★★☆ | 3-polo 25A, low-power 24VDC coil |
- Entorno de aplicación & Casos de la industria
5.1 Aplicaciones recomendadas
Automatización Industrial: Control of three-phase asynchronous motors (fans, bombas de agua, compresores, transportadores)
Sistemas HVAC: Air conditioning compressors and ventilation systems
Electricidad del edificio: Building automation, lighting systems and fire-fighting equipment
Industria energética: Power generation equipment, power distribution systems and renewable energy facilities
Tratamiento de agua: Water pump control and wastewater treatment equipment
Marina & Railway: Transportation industry requiring special certifications (LC1D series advantages)
5.2 Not Recommended Applications
High-frequency switching: Encima 1200 operations per hour (Select LC1Q / LC1R series instead)
High altitude: Elevation over 2000m (Derate load or use special models)
Corrosive environments: Direct exposure to acid, alkali and salt mist (Additional protection required)
Áreas a prueba de explosiones: Special explosion-proof certified models are mandatory
5.3 Casos de aplicación típicos
- Automobile Manufacturing Plant
Used for motor control of stamping production lines. Después del reemplazo, breaking time is reduced by 30%, failure rate drops by 50%, maintenance time is shortened from 2 horas para 30 minutos, and annual maintenance cost is cut by about 200,000 RMB.
- Alimento & Beverage Industry
Applied to three-phase motors of filling lines. Thanks to 2.4W low power consumption, each contactor saves approximately 18 kWh per year under 24-hour continuous operation. A factory with 100 units saves 1,800 kWh annually.
- Centro de datos
Controls air conditioning compressors and ventilation fans. The 24VDC low-power coil ensures stable operation under UPS power supply, reduces battery load and extends backup duration.
- Directrices de selección & Quick Reference Rules
Quick Selection Tips
This is a 3-pole 25A contactor with 24VDC low-power coil and ring terminals. Equipped with 1NO+1NC auxiliary contacts, it features energy efficiency, high reliability and long service life, ideal for motors, bombas de agua y compresores.
Quick Reference Rules
- Coincidencia actual: 25A under AC-3 for 11kW three-phase motors; 40A capacity for resistive loads under AC-1.
- Coil Identification: Suffix BL = 24VDC low power; B7 = 24VAC low power; BD = 24VDC standard power.
- Contactos auxiliares: Standard 1NO+1NC. Models with suffix 01 o 10 for alternative contact configurations.
- Instalación: Montaje en carril DIN estándar de 35 mm; ring terminals ensure reliable connection.
- Energy Saving: Low-power coil (≤2.4W) saves 70% energy compared with standard coil (aprox. 8W.), perfect for long-term operation.
- Fallos comunes & Solución de problemas
| Fenómeno de falla | Posibles causas | Soluciones |
| El contactor no logra entrar | Insufficient coil voltage / Cableado incorrecto | Check power voltage (19.2-30VCC) y cableado |
| bobina quemada | Sobretensión / Reverse polarity | Confirm 24VDC polarity; install overvoltage protection |
| Overheated contacts | Sobrecarga / Cableado suelto | Check load current and retighten terminals |
| Welded contacts | Sobrecarga / Cortocircuito | Inspect circuit protection devices and replace contact assembly |
| Ruido excesivo | Dirty core contact surface | Clean core surface and check short-circuit ring |
- Key Ordering Information
Modelo estándar: LC1D256BL
Modelos alternativos: LC1D25BD (standard power version), LC1D256B7 (24VAC low-power version)
Accesorios compatibles:
Auxiliary contact blocks: LADN series (p.ej. LADN20C: 2NO; LADN02C: 2CAROLINA DEL NORTE)
Overload relays: LRD series (p.ej. LRD08C: 6-10A, matches 25A contactor)
Mounting base: Optional separate base
Application Scenarios for LC1D256BL
Core features: 3-polo 25A, 24VDC low-power coil, larga vida útil, standard DIN rail mounting, 1Contactos auxiliares NA+1NC, strong anti-interference performance.
- Recommended Application Scenarios (Aplicaciones principales)
Featured with 24VDC low-power DC coil, this model perfectly matches standard industrial DC control circuits. Its 25A rating is suitable for three-phase motors up to 11kW and resistive loads up to 40A, serving as a mainstream component for automatic control cabinets.
1.1 Industrial Automation Equipment (Aplicación principal)
Equipo aplicable
PLC/DCS control cabinets, pequeñas máquinas herramienta, manipulator auxiliary mechanisms, inverter-driven fans, small drive motors, test and inspection equipment.
Ventajas
24VDC is the mainstream control voltage for industrial control systems, no extra power converter required.
DC coil provides strong EMC performance, avoiding misoperation caused by inverters and servos.
Baja potencia (≤2.4W) generates little heat during continuous power-on, suitable for 24/7 standby equipment.
1.2 climatización & Air Ventilation Systems
Equipo aplicable
Interior & outdoor unit fans of central air conditioners, condensate pumps, ventiladores de torre de enfriamiento, fresh air handling units, damper drive motors, machine room exhaust fans.
Ventajas
HVAC rooms widely adopt 24VDC automatic control circuits for high compatibility.
Low power design reduces energy consumption and cabinet temperature for year-round continuous operation.
Rango de temperatura de funcionamiento: -25°C ~ +70°C, adapts to drastic temperature changes in machine rooms.
1.3 Electricidad del edificio & Fire Emergency Systems
Equipo aplicable
Domestic water pumps, basement exhaust fans, fire smoke exhaust fans, fire roller shutter motors, centralized emergency lighting circuits (cargas resistivas).
Ventajas
Standard 24VDC for fire emergency circuits, directly powered by UPS/emergency batteries for normal operation during power failure.
Built-in 1NO+1NC auxiliary contacts transmit operation/fault signals to fire alarm hosts and building monitoring systems.
40A load capacity under AC-1 for multi-circuit lighting control.
1.4 Water Treatment Industry (Sewage / Purified Water / Circulating Water)
Equipo aplicable
Circulating water pumps, dosing metering pumps, aeration fans, small agitator motors, ventilation equipment for water treatment workshops.
Ventajas
Almost all automatic control systems for water treatment use 24VDC.
IP20 protection rating adapts to slightly humid indoor machine rooms.
Satisfactory electrical endurance for frequent start-stop operation with low failure rate.
1.5 Nueva energía, fotovoltaica & Energy Storage Cabinets
Equipo aplicable
Cooling fans for PV boxes, temperature control pumps for battery compartments, ventilation motors of energy storage cabinets, small auxiliary inverter loads.
Ventajas
PV and energy storage systems are DC-powered inherently; no inverter needed for 24VDC coil.
Ultra-low coil power avoids extra consumption of backup battery power and extends backup time.
No AC humming for DC coil, ideal for quiet energy storage rooms.
1.6 Logística, almacenamiento & Conveyor Lines
Equipo aplicable
Cintas transportadoras, roller sorting lines, small elevators, warehouse ventilation fans.
Ventajas
Mechanical and electrical endurance meets frequent regular start-stop for long-running production lines.
Auxiliary contacts realize interlock, chain control and sequence start to ensure safety logic of production lines.
1.7 Alimento, Embalaje & Light Industrial Equipment
Equipo aplicable
Conveyors of packaging machines, auxiliary motors of filling lines, dehumidifiers and ventilation fans for workshops.
Ventajas
Suitable for clean indoor workshops without heavy corrosion; standard rail mounting facilitates standardized cabinet wiring.
Compact structure saves cabinet space, a standard OEM component for complete machines.
- No recomendado / Escenarios prohibidos (Riesgos & Alternativas)
2.1 High-frequency Start-Stop (Encima 1200 ciclos por hora)
Riesgo: Excessive switching frequency causes rapid contact ablation, welding and shortened service life.
Alternativa: Schneider LC1R / LC1R series high-frequency contactors.
2.2 Altitude above 2000m
Riesgo: Thin air degrades arc extinction capability, leading to arcing and reduced insulation performance.
Recommendation: Use special high-altitude contactors or derate the load by over 30%.
2.3 Severe Corrosion, Salt Spray & Heavy Dust (Chemical Plants, Coastal Open Areas, Mines)
Riesgo: IP20 rating cannot protect coil, terminals and contacts from acid, alkali, salt mist and dust erosion.
Requisito: Bare installation is forbidden. Use sealed enclosures of IP54 or higher; select anti-corrosion models for chemical environments.
2.4 Direct Outdoor Installation without Protection
Riesgo: Rain, sunlight and condensation lead to coil short circuit and contact oxidation.
Mandatory Requirement: Install inside distribution cabinets or control enclosures with IP54 or higher protection.
2.5 High-power Pure DC Main Circuit Loads
Riesgo: Designed mainly for AC loads with poor DC breaking capacity; high DC loads easily cause contact welding.
Alternativa: Schneider LP1D dedicated DC contactors.
2.6 CA 220 V. / AC380V Control Circuits
Riesgo: 24VDC coil will burn out instantly if connected to AC power.
Alternative AC coil models:
24VACACIONES: LC1D256B7
220VACACIONES: LC1D25M7
380VACACIONES: LC1D25Q7
2.7 Control Three-phase 380V Motors over 11kW (AC-3)
Riesgo: Rated 25A under AC-3 corresponds to 11kW motor; overload results in overheating and burnt contacts.
Alternativa: Upgrade to higher current models such as LC1D32 series.
- Notes for Marginal Operating Conditions (Usable with Protection Measures)
- Basements & Humid Machine Rooms
The product is applicable. Install dehumidifiers inside control cabinets to prevent condensation inside the contactor.
- Ambient Temperature near Limits (-25°C / +70°C)
Derate the load by 10% and avoid long-term full-load operation.
- Coil Wiring Length over 10m
Voltage drop occurs on 24VDC lines. Ensure terminal voltage of the contactor coil is no lower than 19.2V (minimum pull-in voltage).
- Control Inductive Loads such as Motors
Equip with surge suppressors (Schneider LADRC series) to absorb back EMF and protect the coil.
- Scenario Summary
✅ Preferred Applications: Indoor control cabinets, 24VDC control systems, three-phase motors up to 11kW, 24/7 continuous-operation equipment (Automatización, climatización, Fire Protection, Tratamiento de agua, Energy Storage).
❌ Evitar: High-frequency switching, high altitude, unprotected outdoor areas, heavily corrosive environments, high-power DC main circuits, AC control power supply.
contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares