Schneider LC1N2501 AC Contactor

LC1N2501 is a 3-pole 25A AC Contactor of Schneider Electric EasyPact D3N Series. It is standard configured with 3 contactos principales normalmente abiertos + 1 normally closed auxiliary contact. It is suitable for 11kW / 380V motor control under AC-3 duty, widely used in industrial automation and motor control circuits, featuring high reliability and flexible ...

  • Detalles del producto

LC1N2501 is a 3-pole 25A AC Contactor of Schneider Electric EasyPact D3N Series. It is standard configured with 3 contactos principales normalmente abiertos + 1 normally closed auxiliary contact. It is suitable for 11kW / 380V motor control under AC-3 duty, widely used in industrial automation and motor control circuits, featuring high reliability and flexible installation.

  1. Model Segment Definition
SegmentoSignificadoDescripción detallada
LC1Código de serie del productoLC = TeSys series contactor; 1 = Standard AC contactor
norteSub-series identifierN = EasyPact D3N Series (replaces the original LC1E Series); economy design for general industrial applications
25Corriente operativa nominalMain contact rated current 25A (AC-3 / 440V, 60°C)
1Configuración de contactos auxiliares0 = 0 Normalmente abierto; 1 = 1 Normalmente cerrado, i.e. 1 NC auxiliary contact
[Sufijo]Código de voltaje de la bobinap.ej. M5=220V AC 50Hz, B5=24V DC, C5=36V AC, F5=110V AC, Q5=380V AC

Complete Model Examples:

LC1N2501M5N (220V AC coil, 50Hz)、LC1N2501B5N (24V DC coil)

  1. Parámetros de especificación principales
Categoría de parámetroÍndice técnicoObservaciones
Basic Characteristics
Tipo de producto3-Pole AC ContactorEasyPact D3N Series, replacement for LC1E2501
MarcaElectricidad SchneiderBenchmark brand in industrial control
Configuración del contacto principal3NO (3 Normalmente abierto)Standard AC-3 motor control configuration
Configuración de contacto auxiliar1CAROLINA DEL NORTE (1 Normalmente cerrado)Expandable up to maximum 4 contactos auxiliares (2NO+2NC)
Corriente operativa nominal25A (AC-3, 440V, 60°C)Potencia del motor correspondiente: 11kW@380V, 15kW@220V
Tensión operativa nominal≤690 VCA (50/60Hz)Maximum working voltage of main circuit
Rendimiento eléctrico
Rated Insulation Voltage Ui690VCumple con IEC 60947-4-1
Rated Impulse Withstand Voltage Uimp6kVStrong surge withstand capability
Frecuencia de funcionamiento nominal1200 cycles/hour (AC-3)Suitable for frequent start-stop operation
Vida mecánica≥10 millones de ciclosHigh durability design
Vida eléctrica≥1 million cycles (AC-3, corriente nominal)Meets long-term service requirements
Voltaje de control de la bobina24V~380V AC/DC optionalEstándar: 220V y (M5)
Consumo de energía de la bobinaLevantar: aprox. 100Virginia; Tenencia: aprox. 10VirginiaBajo consumo de energía, ahorro de energía & alta eficiencia
Dimensiones físicas
Método de montaje35mm Montaje en carril DIN o con tornillosTwo mounting options for different cabinet layouts
Dimensión generalW45mm × H80mm × D85mmDiseño compacto, ahorra espacio en el gabinete
PesoAprox.. 170gramoLigero para una fácil instalación & handling
Tipo de terminalCircuito principal: Screw type; circuito de control: Spring typeMain circuit compatible with 1.5-10mm² wire, tightening torque 1.85N·m
Condiciones ambientales
Temperatura de funcionamiento-25°C ~ +60°CAmplio rango de temperatura, adapts to harsh industrial environments
Temperatura de almacenamiento-40°C ~ +85°CWithstands extreme temperature storage
Protección de ingresoIP20Protects against finger access and solid foreign objects, suitable for cabinet installation
Humidity Resistance5%~95% RH (sin condensación)Adapts to humid environments
Certificaciones & Estándares
Main StandardsCEI 60947-4-1, GB14048.4Compliant with international and national standards
Marcas de certificaciónCCC, CE, UL, CSAGlobal market access qualifications
  1. Lista de accesorios & Mounting Parts
Part ModelNombreFunciónEscenario de aplicación
LRN07N-LRN35NRelé de sobrecarga térmicaDirect plug-in with contactor, provides motor overload protectionMotor control circuit requiring overload protection
LANN01N-LANN22NBloque de contactos auxiliaresExpand auxiliary contact quantity (máximo. 2NO+2NC)Complex control circuits requiring more auxiliary contacts
LA9D09978CMechanical Interlock AccessoryInterlocks two contactors to prevent phase-to-phase short circuitReversible motor control (Forward/Reverse)
LA9D0902Mecánico + Electrical InterlockDual protection of mechanical and electrical interlockReversible control circuits with high safety requirements
Overvoltage Suppression ModuleRC / Varistor Surge SuppressorAbsorbs back EMF generated during coil de-energizationProtects electronic components in control circuit
Riel de montaje35mm Standard DIN RailFixes contactor in positionStandardized installation inside control cabinet
Cubierta de protección de terminalesInsulating Protective ShieldPrevents accidental electric shock and improves safetyProtection for exposed terminals, complies with safety regulations
Manual de instalaciónOperation GuidelineProvides detailed installation procedures and wiring diagramsOn-site installation guidance to ensure correct wiring
  1. Competidor & Equivalente entre marcas
MarcaModelo de reemplazoSimilar FeaturesDiferencias
Schneider Internal ReplacementLC1D25013-pole 25A, 1NC auxiliary, AC-3 11kWSerie TeSys D, better performance, precio más alto
TEJIDOA16-30-013-pole 25A, 1NC auxiliary, 11kW@400VSimilar dimension, slightly higher coil power consumption, comparable price
siemens3RT2026-1BB403-pole 25A, 1NC auxiliary, 11kW@400VVida mecánica 10 millones de ciclos, vida electrica 2 millones de ciclos, slightly higher price
mitsubishiS-N253-pole 25A, 1NC auxiliary, 11kW@400Vtamaño más pequeño, montaje compacto, precio moderado
chintCJX2-25013-pole 25A, 1NC auxiliary, 11kW@380VAlternativa doméstica, rendimiento de alto costo, similar performance
DeliciosoCJX2S-25013-pole 25A, 1NC auxiliary, 11kW@380VAlternativa doméstica, precios má bajo, suitable for budget-limited projects
  1. Directrices de selección & Soluciones de reemplazo

5.1 Parámetros de selección clave

ParámetroPuntos clave de selecciónRecommended Specification
Rated Current MatchingContactor rated current ≥ motor rated current (Servicio AC-3)25A contactor suitable for ≤11kW/380V motors
Configuración de contacto auxiliarSelect NO/NC quantity according to control circuit demandEstándar 01(1CAROLINA DEL NORTE); Normally Open select 10(1NO); More contacts select 22
Selección de voltaje de bobinaConsistent with control circuit voltageIndustrial common: 220V y(M5); Safety voltage: 24En DC(B5)
Método de montajeDetermined by control cabinet layoutMontaje en carril DIN (estándar); Screw mounting for limited space
Protection RequirementNeed for overload protection and interlock functionMotor control must match LRN thermal relay; Reversible control requires interlock accessory
Frecuencia de funcionamientoHigh-frequency start-stop occasion requires high-cycle modelEstándar 1200 cycles/hour; Ultra-high frequency choose LC1D series

5.2 Recomendaciones de reemplazo

Current rating mismatch:

Motor power ≤7.5kW: Select LC1N1801 (18A)

Motor power 15kW: Select LC1N3201 (32A)

Insufficient auxiliary contacts:

Add LANN series auxiliary contact block, expandable up to 2NO+2NC maximum

Different control voltage:

24V DC control: LC1N2501B5N

380V AC control: LC1N2501Q5N

Higher performance required:

Choose LC1D2501 (Serie TeSys D), vida mecánica 10 millones de ciclos, vida electrica 2 millones de ciclos, stronger vibration resistance

Budget limited:

Adopt domestic alternatives such as Chint CJX2-2501, Delixi CJX2S-2501; similar performance with price reduced by about 30-50%

5.3 Application Precautions

  1. Confirm coil voltage matches control circuit before installation to avoid coil burnout.
  2. Fasten main circuit wiring with recommended torque 1.85N·m to prevent overheating and poor contact.
  3. When directly plugging with LRN series thermal relay, ensure complete latch locking to prevent loosening by vibration.
  4. Reversible control circuit must be equipped with LA9D09978C mechanical interlock to prevent phase-to-phase short circuit.
  5. It is recommended to parallel surge suppressor at both ends of the coil to protect PLC/relay contacts in control circuit.
  6. When ambient temperature exceeds 40°C, derate rated current (10% reduction per additional 10°C rise).
  7. Regularly check contact ablation; replace contactor when main contact wear exceeds 1mm.
  8. Escenarios de aplicación típicos

Direct starting control of three-phase asynchronous motor (≤11kW/380V)

Start-stop control for fans, bombas de agua y maquinaria en general

Electrical control for compressors, conveyors and industrial equipment

Compressor control for air conditioning and refrigeration systems

Lighting and ventilation system control in building electrical systems

Motor control circuits for automated production lines

Auxiliary motor control for machine tool equipment

Output switching control for photovoltaic inverters and UPS power supplies

Complete Model List of Schneider LC1N Series (EasyPact D3N) Contactores

LC1N Series is Schneider Electric EasyPact D3N 3-pole AC contactor, replacing the original LC1E Series. It is designed for AC-3 motor control, covering current ratings from 6A to 95A, with multiple auxiliary contact configurations and coil voltage options. Supports DIN rail or screw mounting with IP20 ingress protection.

  1. Reglas de codificación de modelos
SegmentoSignificadoOptional ValueDescripción
LC1Serie de productosLC1Schneider TeSys contactor series
norteSub-seriesnorteEasyPact D3N Series (tipo de economía)
XXCorriente nominal06/09/12/18/25/

32/38/40/50/65

/80/95

Unidad: A (AC-3/440V, 60°C)
YYContacto auxiliar00/01/10/22/1100=No auxiliary; 01=1NC; 10=1NO; 22=2NO+2NC; 11=1NO+1NC
zCódigo de voltaje de la bobinaB/E/F/M/Q/B=24V; E=48V; F=110V; M=220V; Q=380V
5月7日Frecuencia5月7日5=50Hz; 7= 50/60 Hz universales
N/COrigenN/CN=Standard; C=Made in China

Complete Model Example:

LC1N2501M5N (25A, 1CAROLINA DEL NORTE, 220V CA 50 Hz)

  1. Full Current Rating & Basic Model Matrix

2.1 Standard Auxiliary Configuration (01/10)

Corriente nominalPotencia del motor adaptada(380V)1CAROLINA DEL NORTE(01)1NO(10)Observaciones
6A2.2kilovatiosLC1N0601LC1N0610Minimum current size
9A3kilovatiosLC1N0901LC1N0910
12A4kilovatiosLC1N1201LC1N1210
18A7.5kilovatiosLC1N1801LC1N1810
25A11kilovatiosLC1N2501LC1N2510Most commonly used
32A15kilovatiosLC1N3201LC1N3210
38A18.5kilovatiosLC1N3801LC1N3810
40A22kilovatiosLC1N4001LC1N4010
50A25kilovatiosLC1N5001LC1N5010
65A30kilovatiosLC1N6501LC1N6510
80A37kilovatiosLC1N8001LC1N8010
95A45kilovatiosLC1N9501LC1N9510Maximum current size

2.2 Special Auxiliary Configuration (11/22/00)

Corriente nominal1NO+1NC(11)2NO+2NC(22)No Auxiliary(00)Escenario de aplicación
6A~38ALC1NXX11LC1NXX22LC1NXX00Complex control circuit requiring multi-contacts
40~95ALC1NXX11LC1NXX22LC1NXX00High-power motor control requiring contact expansion
  1. Complete Coil Voltage Options

3.1 AC Coil Voltage Code

Voltage CodeVoltaje de la bobinaFrequency CodeComplete Model ExampleEscenario de aplicación
B24V y5(50Hz)/7(50/60Hz)LC1N2501B5N / LC1N2501B7NSafety voltage control, Salida PLC
do36V y5-7LC1N2501C5N / LC1N2501C7NSafety circuit, machine tool control
mi48V y5-7LC1N2501E5N / LC1N2501E7NIndustrial control, special equipment
F110V y5-7LC1N2501F5N / LC1N2501F7NNorth American standard, partial equipment
METRO220V y5-7LC1N2501M5N / LC1N2501M7NChinese industrial standard, most widely used
PAG230V y5-7LC1N2501P5N / LC1N2501P7NEuropean standard, compatible with 220V
q380V y5-7LC1N2501Q5N / LC1N2501Q7NHigh-voltage control circuit, direct 380V supply
R400V y5-7LC1N2501R5N / LC1N2501R7NEuropean industrial standard
S415V y5-7LC1N2501S5N / LC1N2501S7NSoutheast Asian standard

3.2 DC Coil Voltage Code

Voltage CodeVoltaje de la bobinaComplete Model ExampleEscenario de aplicación
B24En DCLC1N2501B5NSafety control, PLC digital output
l48En DCLC1N2501L5NIndustrial DC system
k110En DCLC1N2501K5NSpecial DC equipment
norte220En DCLC1N2501N5NHigh-voltage DC control
  1. Common Complete Model Combinations
Modelo completoActualContacto auxiliarVoltaje de la bobinaPotencia del motor adaptadaAplicación típica
LC1N2501M5N25A1CAROLINA DEL NORTE220V CA 50 Hz11kilovatiosbomba de agua & fan control
LC1N3210B7N32A1NO24V CA 50/60 Hz15kilovatiosPLC control circuit
LC1N1801F5N18A1CAROLINA DEL NORTE110V CA 50 Hz7.5kilovatiosExport equipment
LC1N5011M7N50A1NO+1NC220V CA 50/60 Hz25kilovatiosCompressor control
LC1N6522Q5N65A2NO+2NC380V CA 50 Hz30kilovatiosLarge fan
LC1N0900B5N9ANo auxiliary24V CA 50 Hz3kilovatiosSimple control circuit
LC1N9511M7N95A1NO+1NC220V CA 50/60 Hz45kilovatiosHigh-power motor
  1. Selection Reference Table

5.1 Current Rating vs Motor Power (AC-3/380V)

Corriente nominalPotencia del motor(kilovatios)Wire Size(milímetros)Matching Thermal Relay
6A2.21.5LRN06N
9A31.5LRN06N
12A41.5LRN07N
18A7.52.5LRN10N
25A114LRN14N
32A156LRN21N
38A18.56LRN21N
40A2210LRN25N
50A2510LRN32N
65A3016LRN35N
80A3725LRN35N
95A4535LRN40N

5.2 Auxiliary Contact Expansion Options

Base ModelExpandable AccessoryExpanded Contact ConfigurationEscenario de aplicación
LC1NXX01/10LANN01N(1NO)2NO / 2CAROLINA DEL NORTEAdd more control circuit contacts
LC1NXX01/10LANN22N(2NO+2NC)3NO+2NC / 2NO+3NCComplex control logic
LC1NXX00LANN01N+LANN02N1NO+1NCExpand from no auxiliary to standard configuration
  1. Quick Model Selection Guide
  2. Confirm current rating: Seleccione según la potencia del motor. (Bajo servicio AC-3, contactor rated current ≥ motor rated current).
  3. Select auxiliary contacts: 01(1CAROLINA DEL NORTE) for stop control; 10(1NO) for self-locking; 11(1NO+1NC) para control reversible.
  4. Match coil voltage: Consistent with control circuit voltage (220V AC common; 24V DC for safety occasions).
  5. Frequency selection: Domestic standard 50Hz(Código 5); Export equipment use universal 50/60Hz(Código 7).
  6. Accessory configuration: Motor control must match LRN thermal relay; Reversible control requires LA9D mechanical interlock.
  7. Common Model Replacement Table
Modelo OriginalModelo de reemplazoMotivo del reemplazo
LC1E2501LC1N2501EasyPact D3N replaces original EasyPact E Series
LC1D2501LC1N2501Economy model replaces high-performance model, cost reduced by approx. 20%
CJX2-2501LC1N2501Import replaced by domestic, performance improved with similar price