Modelo completo: RAK-TW.5010S-H
Nro. de orden: S55700-P122
Marca: SIEMENS (Building HVAC Series)
Tipo de producto: Capillary frost protection thermostat (TW frost-type temperature limit switch)
Core Contact: SPDT single-pole double-throw switching contact
Origen: Original imported from Switzerland/Germany
Compatible Power Supply: Wide voltage range AC 24V ~ AC 250V
- Segment-by-Segment Model Code Breakdown
- RAK: General prefix for full series of mechanical capillary temperature switches
- TW: Type Winter Frost, dedicated thermostat for frost protection (low-temperature anti-freeze logic)
- 5010: Temperature measuring range code `-10℃ ~ +50℃`
primeros dos dígitos 50: Upper limit 50℃
últimos dos dígitos 10: Lower limit -10℃
- S: Sleeve-free, no immersion temperature sleeve, fixed only by binding capillary
- h: Standard housing with push-in quick-disconnect terminals
Supplementary coding rules for the same series:
B = Equipped with immersion temperature sleeve
M = With external adjustment knob
TR = High temperature limit type
ST = Overheat protection thermostat
- Cableado de terminales & Lógica de contacto
Definición de terminal (SPDT Switching Contact)
Terminal común 1, normally closed circuit 1-3, normally open circuit 1-2
- Frost Protection Action Logic (Triggered by Temperature Drop)
When medium temperature drops to the set frost protection value → contacts switch: circuito 1-3 disconnects, circuito 1-2 cierra, activating heat tracing/circulating pump anti-freeze circuit.
- Restablecer lógica (Recovered by Temperature Rise)
When temperature rises by a fixed hysteresis of 5K → contacts automatically switch back to 1-3, and the anti-freeze circuit shuts down.
Contact Load Capacity (CA 250 V)
Circuito 1-2 (Frost protection output): 16(2.5)A
Circuito 1-3 (Normal state signal): 6(2.5)A
Terminal structure: Tool-free push-in wiring, suitable for 0.5~2.5mm² solid and flexible wires.
- Núcleo Eléctrico & Parámetros mecánicos
- Rango de temperatura ajustable: -10°C ~ +50 °C
- Histéresis del interruptor: Fixed 5K (5℃), no ajustable
- Capillary Length: Standard 1600mm liquid expansion temperature-sensing capillary
- Clase de protección: IP43 housing, UV-resistant flame-retardant plastic shell
- Three-in-One Mounting Method: Pipe strap mounting / duct sleeve mounting / wall mounting
- Vida útil mecánica: ≥ 100,000 ciclos de conmutación
- Temperatura ambiente de funcionamiento: -20℃ ~ +60℃
- Dimensiones: 156×72×55mm; Net weight ≈ 320g
- Estándares de cumplimiento: CE, RoHS, TU ÚNICO 14597 safety standard for HVAC thermostats
- Funciones & Escenarios de aplicación
Función principal
Provides low-temperature frost protection for pipes and air ducts. Automatically activates anti-freeze heat tracing and circulating pumps when medium temperature is too low to prevent water pipe cracking; meanwhile, Las señales de alarma de baja temperatura se pueden cargar en el PLC..
Campos de aplicación segmentados
- Aire Acondicionado Central / Sistemas de conductos de aire
Monitorización de heladas en tuberías de agua fría y conductos de aire fresco de aparatos de aire acondicionado; activar cables de trazado calefactor de tuberías en condiciones de baja temperatura.
- Calefacción & Salas de calderas de agua caliente
Protección contra heladas para intercambiadores de calor de placas, Colectores de agua y tuberías principales de calefacción exterior..
- Construcción de sistemas BA electromecánicos
Alarma de baja temperatura para enfriadoras, Tuberías de agua de reposición de torres de enfriamiento y tuberías de plomería en estacionamientos subterráneos..
- Purificación / Sistemas HVAC farmacéuticos
Bloqueo anticongelante para tuberías de agua circulante y conductos de aire de proceso en talleres limpios.
- Soporte de cadena de frío & Sala de ordenadores Aire acondicionado
Frost monitoring for pipelines of outdoor water-cooled units and precision air conditioning water pipes in equipment rooms.
- Heating Pipe Networks in Industrial Workshops
Anti-freeze protection for workshop circulating hot water pipes during winter shutdown.
- Selection Table for RAK-TW Frost Protection Series
| Modelo | Temperature Measuring Range | Sleeve Configuration | Core Application Scenario |
| RAK-TW.5010S-H | -10~50 ℃ | Sleeve-free Type S | Pipe strap frost protection (este modelo) |
| RAK-TW.5010B-H | -10~50 ℃ | With immersion sleeve Type B | Immersion temperature measurement for water tanks / water manifolds |
| RAK-TW.1000S-H | 15~95℃ | Sleeve-free | High temperature limit protection for hot water |
| RAK-TW.1200S-H | 40~120℃ | Sleeve-free | Overheat protection for steam and high-temperature heat conduction pipelines |
- Reemplazo & Cross-Brand Substitution Instructions
7.1 Direct Substitutes from Siemens Same Series
For water tank immersion application: RAK-TW.5010B-H (only equipped with extra temperature sleeve, identical temperature range and contacts)
For high-temperature overheat protection only: Switch to RAK-TW.1000 series (temperature range 15~95℃)
7.2 Cross-Brand Substitutes with Identical Functions
danfoss: 060G3450 frost capillary thermostat
Controles Johnson: A11B-4C frost limit switch
Alternativa doméstica: Shanghai Fengshen WTQ series capillary frost thermostat
7.3 Notas sobre el reemplazo
- Only TW frost type (triggered by temperature drop) se puede utilizar; TR overheat thermostats (act on temperature rise with opposite logic) are prohibited.
- The capillary length of the substitute should match 1600mm as much as possible to avoid temperature measurement delay.
- The built-in contact is SPDT switching type; it cannot be directly replaced by thermostats with single NO or single NC contacts.
- Strict Usage Prohibitions
- Do not apply to steam or oil media over 50℃ (exceeding the range will permanently damage the capillary).
- The capillary must not be sharply bent or squeezed; minimum bending radius ≥50mm, otherwise temperature measurement will fail.
- IP43 rating is only applicable to indoor or covered outdoor environments; long-term exposure to open rain is forbidden.
- Contacts are only for AC24~250V control circuits; connection to 380V main power circuits is prohibited.
- Do not cut the capillary; length modification will deviate the calibrated temperature measurement accuracy.
Replacement Instructions for Temperature-Sensing Probe (Capillary Bulb) of SIEMENS RAK-TW.5010S-H
- Conclusión central
The temperature-sensing probe/capillary cannot be replaced separately by original parts. The temperature bulb, El capilar y el actuador de fuelle interno forman un conjunto soldado integrado sellado que no se puede desmontar para su reemplazo..
- El capilar y el cuerpo del termostato están llenos de un líquido de expansión especial y soldados herméticamente.. El desmontaje provocará fugas de líquido y desguace permanente..
- Siemens no vende sondas capilares de repuesto separadas con especificación de 1600 mm., y los repuestos divididos no están disponibles.
- Una vez doblada la sonda, exprimido, filtrado o roto, la única solución compatible es reemplazar toda la unidad con RAK-TW.5010S-H.
- Principio estructural (Por qué la sonda no se puede reemplazar por separado)
- Medio de trabajo: El bulbo de temperatura y el capilar están llenos herméticamente con un líquido de alto coeficiente de expansión., que acciona el microinterruptor interno mediante expansión y contracción térmica.
- Proceso de conexión: La raíz del capilar y el fuelle interno de la carcasa están integralmente soldados y sellados sin juntas desmontables..
- Coincidencia de calibración: La longitud del capilar de 1600 mm., El volumen del bulbo y el volumen de llenado del líquido están calibrados uniformemente en fábrica.. El reemplazo arbitrario de la sonda o la modificación de la longitud del capilar darán lugar a:
Cambio severo de la temperatura de funcionamiento e histéresis fuera de control;
Fallo de la lógica anticongelante de baja temperatura y riesgo de rotura de tuberías;
Incumplimiento de DIN EN 14597 Certificación de termostato de seguridad HVAC y aceptación de equipos no calificados..
- Juicio de culpa & Soluciones
3.1 Síntomas típicos de una sonda dañada
Capilar doblado y aplanado., pared de tubería rota con fuga de líquido;
Bombilla de temperatura abollada o fracturada por impacto;
El termostato permanece desconectado durante mucho tiempo sin respuesta a través de la ventana de ajuste de temperatura;
La desviación de la temperatura de funcionamiento supera los ±5 ℃ y el ajuste no es válido.
3.2 Métodos de manipulación
- Para proyectos formales que requieren aceptación: Compre una unidad RAK-TW.5010S-H completa nueva para reemplazo directo.
- Uso temporal de emergencia (sin requisito de aceptación, No se recomienda el uso a largo plazo.): No corte ni empalme el capilar.; solo une el segmento intacto temporalmente para medir la temperatura con precisión no garantizada.
- Unidades sustitutas completas de la misma especificación (No se requiere modificación de montaje)
- Reemplazo directo con modelo idéntico original.: RAK-TW.5010S-H (Número de pedido. S55700-P122, 1600capilar mm sin manguito)
- For water tank immersion application: RAK-TW.5010B-H (rango de temperatura idéntico, manguito de temperatura adaptado y otros parámetros totalmente consistentes)
- Instalación & Restricciones de uso (Para evitar daños a la sonda)
- Radio de curvatura mínimo del capilar ≥50 mm; curvatura aguda en ángulo recto, Prohibido pisar y apretar..
- Corte, Está estrictamente prohibido truncar y empalmar el capilar..
- La bombilla de temperatura solo puede contactar con medios ≤50 ℃; Está prohibido el contacto con fuentes de calor de alta temperatura o escorias de soldadura..
- Evite que las abrazaderas metálicas afiladas rayen la pared exterior del capilar durante la unión del tubo..
- No tire del capilar con fuerza durante el transporte.; dejar subsidio suelto.
- Unidades completas alternativas de marcas cruzadas
Si el ciclo de entrega de los productos Siemens es largo, sustituir por termostatos capilares anticongelantes completos de lógica idéntica:
Danfoss 060G3450 (-10~50 ℃, 1.6m interruptor de escarcha SPDT capilar)
Interruptor de límite de heladas de baja temperatura A11B-4C de Johnson Controls
contactor,cortacircuitos,sensor,Codificador,SOCIEDAD ANÓNIMA,Convertidor



















NH42-63-318x560.png)