In the model numbers of the Contactor de CA CHINT CJX2 serie, the meaning of the four-digit suffix is mainly related to the rated current and the configuration of auxiliary contacts, and the specific rules are as follows:
- Decomposition and Meanings of the Four-digit Number
Take the common models CJX2-1210 and CJX2-0901 as examples:
- The first two digits (como 12, 09)
They represent the rated current of the contactor, with the unit being amperes (A).
– Por ejemplo:
12 indicates that the rated current is 12A (suitable for small and medium-sized loads, such as lighting and small motors);
09 indicates that the rated current is 9A (suitable for low-load scenarios).
Special instructions:
– For some models, there may be “rounding” or approximate values. Por ejemplo, the rated current of CJX2-1810 is 18A, but it may be marked as 17.5A in the actual product manual (it is necessary to refer to the official parameters).
– If the model contains a letter (such as CJX2-1210N), “norte” usually indicates a reversible contactor, but the meaning of the four-digit number remains unchanged.
- Los dos últimos dígitos (como 10, 01)
They represent the quantity and type of auxiliary contacts, in the format of “number of normally open contacts + number of normally closed contacts”.
– Por ejemplo:
10 indica 1 contacto normalmente abierto (NO) y 0 contactos normalmente cerrados (CAROLINA DEL NORTE);
01 indica 0 normally open contacts and 1 contacto normalmente cerrado;
22 indica 2 normally open contacts and 2 contactos normalmente cerrados (Por ejemplo, in CJX2-4011, the last two digits “11” indicate 1NO + 1CAROLINA DEL NORTE).
Special instructions:
– For some models, the functions may be further distinguished by “letter suffixes”. Por ejemplo, “04” in CJX2-1204N indicates 0 normally open contacts and 4 contactos normalmente cerrados, but this type of model is relatively rare, and it is necessary to confirm in combination with the specific product parameters.
- Examples of Typical Models and Parameter Correspondences
| Modelo | Corriente nominal (A) | Configuration of Auxiliary Contacts | Escenarios de aplicación |
| CJX2-0910 | 9 | 1NO | Circuitos de iluminación, control of small relays |
| CJX2-1201 | 12 | 1CAROLINA DEL NORTE | Motor protection circuits (normally closed signal feedback) |
| CJX2-1810 | 18 | 1NO | Small and medium-sized motors (such as below 1.5kW) |
| CJX2-2501 | 25 | 1CAROLINA DEL NORTE | Control of industrial equipment (requiring normally closed signals) |
| CJX2-4011 | 40 | 1NO + 1CAROLINA DEL NORTE | Complex logic control (como arranque estrella-triángulo) |
III. Association between Other Key Parameters and Models
- Número de polos (Polo)
It is usually not directly reflected in the four-digit number, and it is necessary to confirm through the model suffix or product description.
– Por ejemplo:
CJX2-1210N 220V indicates a 3-pole (3PAG) reversible contactor, suitable for three-phase motor control;
CJX2-6504N indicates a 4-pole (4PAG) contactor, used in special power distribution scenarios.
- Voltaje de la bobina
The voltage information may be included in the model, but it is necessary to judge in combination with the complete model.
– Por ejemplo:
CJX2-1210 24V indicates that the coil voltage is 24V AC;
CJX2-1801 380V indicates that the coil voltage is 380V AC.
- Certificaciones y estándares
Certificación CE: Complies with the EN 60947-4-1 estándar (low-voltage switchgear and controlgear);
Certificación CCC: Models sold in China need to pass the China Compulsory Certification.
- Sugerencias de selección y uso
- Select the Rated Current According to the Load Current
Principio: The rated current of the contactor ≥ 1.2 veces la corriente de carga (considering the motor starting impact).
Ejemplo: When controlling a 10A motor, CJX2-1210 (12A) should be selected instead of CJX2-0910 (9A).
- Select the Auxiliary Contacts According to the Control Logic
Contactos normalmente abiertos (NO): Used for signal output (such as start indication);
Contactos normalmente cerrados (CAROLINA DEL NORTE): Used for safety interlocking (such as emergency stop circuits).
- Pay Attention to Environmental and Installation Requirements
Nivel de protección: Usually IP20 (protección contra el contacto con los dedos), and models with an IP55 or above protection level need to be selected for special scenarios;
Método de instalación: Supports rail installation (35mm estándar), which is convenient for quick replacement.
- Official Documents and Verification
For further confirmation, you can refer to the CHINT official website or product manuals. Por ejemplo:
– The technical parameters of CJX2-1210 clearly state “rated current 12A, auxiliary contact 1NO”;
– The manual of CJX2-0901 states “9A, 1Contacto auxiliar NC”.
Through the above rules, users can quickly identify the core parameters of the CJX2 contactor to ensure accurate model selection.
contactor,cortacircuitos,inversor solar,sensor,Codificador,SOCIEDAD ANÓNIMA


















NH42-63-318x560.png)