Numéro de commande: 6ES7193-6AR00-0AA0
Designation: SIMATIC ET200SP Bus Adapter BA 2×RJ45
Description: Dedicated bus adapter for ET200SP IM155-6 PN interface module, equipped with 2-channel RJ45 PROFINET ports.
⚠️ Common Misconception: It is NOT a BaseUnit. BaseUnits share the same 6ES7193 prefix but carry 6BPxx type codes. This unit is a communication bus adapter, plugged onto the rear of the IM155-6 interface module.
Répartition du code modèle
6ES7: SIMATIC S7 automation product
193: ET200SP accessories (bus adapters / base units)
6: ET200SP platform
AR00: BA 2×RJ45 dual RJ45 bus adapter
0AA0: Version standard & conditionnement
Principales spécifications techniques
| Article | Paramètre |
| Interfaces | 2 × RJ45 (PROFINET) |
| Communication Speed | 10/100 Mbit/s, PROFINETRT / IRT |
| Type de câble | Industrial CAT5e cable; maximum. 100 m per segment |
| Supported Topologies | Line topology, MRP media redundant ring |
| Dimensions | W 20 mm × H 69.5 mm × D 59 mm |
| Poids | ≈ 46 g |
| Classe de protection | IP20 (pour installation en armoire uniquement) |
| Température de fonctionnement (Horizontal Mount) | -30 ℃ ~ +60 ℃ |
| Température de fonctionnement (Vertical Mount) | -30 ℃ ~ +50 ℃ |
| Max.. Altitude d'installation | 5000 m (derating required above 2000 m) |
| Origine | Allemagne |
Compatible Interface Modules
Fits all IM 155-6 PN series interface modules:
6ES7155-6AU01-0BN0 IM155-6 PN ST
6ES7155-6AU00-0DN0 IM155-6 PN HS
6ES7155-6AA01-0BN0 IM155-6 PN HF
Applications typiques
- Line Daisy-Chain Connection: Port 1 receives signal from PLC, Port 2 cascades to the next ET200SP station.
- PROFINET MRP Ring Network: Form closed redundant ring with dual-port devices at both ends.
- Comparison with alternative ET200SP bus adapters
| Numéro de commande. | Type d'interface | Application |
| 6ES7193-6AR00-0AA0 | 2×RJ45 | Widely used for cascading & ring topology |
| 6ES7193-6AF00-0AA0 | 1×RJ45 | Single port for end stations without further cascading |
| 6ES7193-6AP00-0AA0 | 2×FC quick connect | For PROFINET FC field cables |
| 6ES7193-6AG00-0AA0 | 2×LC fiber optic | Long-distance fiber communication |
Sélection & Directives d'installation
- IM155-6 PN module must be fitted with a bus adapter; the bare module cannot accept network cables directly.
- MRP redundant ring requires 6AR00 dual RJ45 version. Single-port 6AF00 cannot support ring topology.
- It is recommended to use Siemens industrial green PROFINET cables and industrial shielded RJ45 plugs.
- The module shall only be mounted on DIN35 rail inside control cabinets; outdoor installation is prohibited.
Common Troubleshooting Tips
Intermittent communication: Check shielding grounding of RJ45 connectors and ensure all 8 cable cores are terminated.
Failure to establish MRP ring: Confirm MRP is activated in TIA Portal and all ring nodes use dual-port bus adapters.
Distinction reminder: 6ES7193-6BPxx = IO module base unit, cannot be used for network connection.
Application Scenarios for 6ES7193-6AR00-0AA0 (BA 2×RJ45)
Fonctionnalité de base: Dual RJ45 bus adapter dedicated to ET200SP IM155-6 PN with integrated two-port switch. Supports PROFINET daisy-chain wiring and MRP redundant ring, eliminating extra external switches and enabling multiple remote IO stations deployed sequentially along one cable route.
> Référence: Single-port 6AF00 is adopted for isolated end stations; 6AR00 is selected when cascading or ring redundancy is required.
- Scenarios Classified by Network Topology (Most Widely Used in Engineering)
(1) Daisy-Chain Topology (Highest Consumption)
✅ Suitable Conditions: Equipment arranged linearly along production lines, budget limité, no network redundancy requirement
Mise en page: PLC switch → ET200SP (Port1 IN, Port2 OUT) → next ET200SP → …
Avantages: Greatly reduce cable routing between control cabinets; no additional industrial switches needed.
Inconvénients: All downstream stations will go offline if the middle link is broken.
Typical Sites:
Packaging lines, conveyor lines, roller lines, lignes de tri
Linked machine tool production lines, machines à bois, plastic extrusion lines
Distributed IO along AGV guide tracks
Multi-cabinet connection for medium & small complete machines (main cabinet → multiple workstation sub-cabinets)
(2) MRP Media Redundant Ring (Preferred for High-Reliability Applications)
✅ Suitable Conditions: Unplanned production shutdown is unacceptable; automatic recovery upon single cable breakage
Mise en page: All ET200SP stations form a closed loop, MRP enabled in TIA Portal. Communication path switches automatically if one cable fails to maintain continuous production.
Typical Sites:
Automotive welding, coating and final assembly conveyor lines
Automated warehouses, stacker crane logistics systems
Continuous production lines in food & industries pharmaceutiques
Stations d'épuration, pump station group process control
(3) Hybrid Topology (Daisy-Chain + Star)
ET200SP stations along each production line are connected in daisy chain, and the terminal of each line is connected to the central switch. Balances convenient wiring and centralized management.
- Industry-Specific Application Cases
🔹 Automotive Manufacturing (Application la plus courante)
- Welding workshop: Distributed signal collection for body fixtures, welding guns and sensors; linear daisy-chain layout on long conveyors; MRP rings deployed at critical sections.
- Coating lines: Remote IO deployed along electrophoresis, drying and conveyor chains.
- Final assembly lines: IO for tightening tools, stoppers and photoelectric sensors arranged along assembly lines.
🔹 Logistics & Warehouse Automation
Automated stereoscopic warehouses, sorting conveyors, cross-belt sorters
Mass distributed workstation IO arranged along roller conveyors; MRP rings adopted on key logistics trunk lines to avoid full sorting line shutdown caused by cable faults.
🔹 Packaging, Caoutchouc & Plastique, Machines d'impression (Mainstream for OEM Machine Builders)
Multi-unit complete equipment: Extrudeuses, film blowing lines, lignes de remplissage, carton packaging lines
Equipment consists of main cabinet plus several independent workstation sub-cabinets connected via daisy chain to save wiring.
> OEM Selection Tip: Use 6AR00 for cascading multiple ET200SP inside one machine; adopt 6AF00 for the last end station to cut costs.
🔹 Food & Industrie pharmaceutique
Continuous processes including filling, sterilization and packaging; distributed control cabinets in clean areas.
MRP ring topology is generally recommended for continuous production to avoid material scrapping caused by network failures.
🔹 Water Treatment, Municipal Pump Stations & Environmental Projects
Aeration tanks, valve wells and chemical dosing systems in wastewater plants; pump stations distributed along pipelines.
Daisy-chain network for long-distance distributed IO; MRP redundancy enabled for critical processes.
🔹 Machine Tools & Metal Processing
Flexible production lines, gantry robots, linked machine tools; peripheral IO for clamping, cooling and loading/unloading signal acquisition.
🔹 New Energy Industry
Battery PACK production lines, PV module assembly lines with massive distributed workstation IO.
- Guide de sélection: When to Choose 6AR00 / Alternatives
✅ Prefer 6ES7193-6AR00-0AA0
- ≥2 ET200SP stations on one link requiring cascading
- PROFINET MRP redundant ring to be implemented
- Espace de rangement limité; no room for additional SCALANCE switches
- Production lines arranged linearly with remote IO placed sequentially along conveyors
❌ Not Recommended (Choose 6ES7193-6AF00 Single RJ45 Instead)
- The ET200SP is the last end station without further cascading
- All stations connect to the switch via independent star cables, no daisy-chain layout
- On-Site Installation Precautions
- IP20 rating for indoor cabinet use only; fully enclosed protective cabinets are mandatory for outdoor or humid environments.
- MRP ring requirement: All nodes in the ring must use dual-port 6AR00; single-port 6AF00 cannot be mixed in the ring.
- Limit cascading quantity to ≤8~10 stations per daisy-chain link to avoid excessive communication latency.
- For transmission distance over 100 m or heavy electromagnetic interference, switch to fiber adapter 6ES7193-6AG00-0AA0.
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires