NXC-65 from the Kunlun Series by CHINT Electric is a 3-pole AC contactor, évalué à 65A dans la série NXC. Le modèle complet est généralement exprimé sous la forme NXC-65 [Tension de bobine] [Fréquence] (par ex., NXC-65 220V 50Hz). It is mainly used for frequent starting and control of AC motors, as well as remote making and breaking of circuits.
Paramètres électriques de base
| Article | Spécification | Description |
| Courant opérationnel nominal (C'est à dire) | 65UN | Rated current of the main circuit |
| Conventional Thermal Current (je) | 80UN | Courant de fonctionnement continu maximum |
| Tension de fonctionnement nominale (Ue) | 220V~690V | Voltage range of the main circuit |
| Nombre de pôles | 3P. | Three-phase main contact design |
| Configuration des contacts principaux | 3NON (3 Normalement ouvert) | Standard for connecting three-phase power |
| Contacts auxiliaires | 1NON + 1Caroline du Nord | Intégré 1 NO and 1 Caroline du Nord, extensible |
| Tension de bobine | AC24V/127V/220V/380V, etc.. | Multiple voltages available for various control systems |
| Durée de vie mécanique | 1,200,000 opérations | Cycles de fonctionnement mécaniques |
| Durée de vie électrique | 100,000 opérations | Electrical cycles under rated load |
| Normes applicables | GB/T 14048.1/IEC 60947-1, GB/T 14048.4/CEI 60947-4-1 | Normes nationales et internationales |
Caractéristiques du produit
- Structure compacte: Kunlun series design, petite taille, low installation space requirement
- Haute fiabilité: Made of high-quality materials with precision manufacturing, adapté aux environnements industriels difficiles
- Faible consommation d'énergie: Low coil power loss, obvious energy-saving effect
- Installation facile & entretien: Montage sur rail DIN standard de 35 mm, clear terminals for easy operation
- Strong expandability: Optional auxiliary contacts, air delay modules and other accessories available
- Good safety performance: Excellent arc extinguishing performance and high breaking capacity
Applications
AC motor control: Frequent start, stop and reversing control for three-phase asynchronous motors up to approx. 30kW
Systèmes d'automatisation industrielle: Control of production lines, convoyeurs, les fans, pompes, etc..
Electrical control systems: Combined with thermal overload relays to form magnetic starters for motor overload protection
Électricité du bâtiment: Systèmes de climatisation, fire equipment, water pump control systems
New energy equipment: Auxiliary control circuits for charging piles, Onduleurs photovoltaïques, etc..
Partial List of CHINT NXC Series Models
| Modèle | Courant nominal | Conventional Thermal Current | Typical Motor Power | Remarques |
| NXC-06 | 6UN | 10UN | Up to 2.2kW | Minimum rating |
| NXC-12 | 12UN | 16UN | Up to 5.5kW | |
| NXC-18 | 18UN | 25UN | Up to 7.5kW | |
| NXC-25 | 25UN | 32UN | Up to 11kW | |
| NXC-32 | 32UN | 40UN | Up to 15kW | |
| NXC-40 | 40UN | 50UN | Up to 18.5kW | |
| NXC-50 | 50UN | 63UN | Up to 22kW | |
| NXC-65 | 65UN | 80UN | Up to 30kW | |
| NXC-80 | 80UN | 100UN | Up to 37kW | |
| NXC-95 | 95UN | 125UN | Up to 45kW | |
| NXC-115 | 115UN | 140UN | Up to 55kW | |
| NXC-150 | 150UN | 175UN | Up to 75kW |
Comparaison entre marques (Equivalent AC Contactors)
Below is a comparison between CHINT NXC-65 and equivalent contactors from major brands, all functionally compatible:
| CHINT | Schneider | Siemens | ABB | Délicieux | Compatibilité |
| NXC-65 | LC1D65M7C | 3RT2036-1AP00 | A63-30-10 | CJX2-6511 | Fonctionnellement compatible, slight dimensional differences, mounting may need adjustment |
Brand Feature Comparison
| Marque | Core Strengths | Applications typiques |
| CHINT | Rentable, extensive after-sales network | Contrôle industriel général, civil & électricité du bâtiment |
| Schneider | International brand, technologie mature, haute fiabilité | High-end industrial automation, critical equipment |
| Siemens | High intelligence, strong communication functions | Industrie 4.0, intelligent manufacturing |
| ABB | Haute performance, robust in harsh environments | Industrie lourde, nouvelle énergie, transport ferroviaire |
| Délicieux | Affordable, high domestic market share | PME, civil electrical systems |
Remarques importantes
- Ensure the coil voltage matches the control system to avoid malfunction.
- Use the contactor with protective devices such as thermal overload relays for motor overload protection.
- Pour un fonctionnement à haute fréquence, select models with longer electrical life or increase maintenance frequency.
- Ensure firm wiring of main and control circuits to prevent failures caused by poor contact.
CHINT Contactor Full Series Coding System & Cross-Brand Reference
- CHINT Contactor Series Overview & Règles de dénomination
1.1 Main Series Classification
| Série | Positionnement | Plage actuelle | Applications typiques |
| Série NXC | Kunlun, new flagship | 6UN ~ 630A | Contrôle industriel général, motor starting, distribution d'énergie |
| Série NC1 | Economic basic series | 9UN ~ 95A | Petit matériel, contrôle de l'éclairage |
| Série NC2 | Standard industrial series | 9UN ~ 630A | General industrial & commande moteur |
| Série NC8 | High-performance series | 6UN ~ 100A | Opération fréquente, contrôle de précision |
| Série CJX2 | Classic predecessor of NXC | 9UN ~ 95A | Traditional industrial equipment, petits moteurs |
| Série CJ20 | High-current series | 10UN ~ 630A | High-power motors, heavy-duty equipment |
| CJ19 Series | Capacitor switching dedicated | 16UN ~ 100A | Reactive power compensation, capacitor cabinets |
| NCH8 Series | Ménage / civil use | 16A~63A | Smart home, small appliances |
| NXJ Series | Mini electromagnetic relay | 5A~10A | Circuits de contrôle, signal switching |
| CKJ Series | Vacuum contactor | 63UN ~ 630A | High-voltage applications, démarrages fréquents |
1.2 CHINT Contactor Model Naming Rules
NXC Series Format
NXC □□□ [M.] [Tension de bobine] [Fréquence]
│ │ │ │ │
│ │ │ │ └─ Coil frequency (50Hz/60 Hz, default 50Hz)
│ │ │ └─ Coil voltage (AC24V/110V/220V/380V or DC24V/110V/220V)
│ │ └─ M = reversing contactor; blank = non-reversing
│ └─ Rated operational current (UN)
└─ Brand code + product type (CHINT + Contacteur CA)
Auxiliary Contact Marking
Modèle de base: default 1NO + 1Caroline du Nord (11)
Extended format: NXC-□□□-[XX], where XX = contact combination (01=0NO1NC, 22=2NO2NC)
Special Function Codes
Z: DC-operated contactor
N: Reversing contactor (NS = horizontal, NC = vertical)
-12: Newer version with improved performance
- Complete CHINT Contactor Model List
2.1 Full NXC Series (Kunlun)
| Modèle | Courant nominal | Courant thermique | Typical Motor Power (AC-3, 380V) | Base Aux. Contacts |
| NXC-06 | 6UN | 10UN | Up to 2.2kW | 1NON+1NC |
| NXC-09 | 9UN | 12.5UN | Up to 3kW | 1NON+1NC |
| NXC-12 | 12UN | 16UN | Up to 5.5kW | 1NON+1NC |
| NXC-18 | 18UN | 25UN | Up to 7.5kW | 1NON+1NC |
| NXC-25 | 25UN | 32UN | Up to 11kW | 1NON+1NC |
| NXC-32 | 32UN | 40UN | Up to 15kW | 1NON+1NC |
| NXC-40 | 40UN | 50UN | Up to 18.5kW | 1NON+1NC |
| NXC-50 | 50UN | 63UN | Up to 22kW | 1NON+1NC |
| NXC-65 | 65UN | 80UN | Up to 30kW | 1NON+1NC |
| NXC-80 | 80UN | 100UN | Up to 37kW | 1NON+1NC |
| NXC-95 | 95UN | 125UN | Up to 45kW | 1NON+1NC |
| NXC-115 | 115UN | 140UN | Up to 55kW | 1NON+1NC |
| NXC-150 | 150UN | 175UN | Up to 75kW | 1NON+1NC |
| NXC-185 | 185UN | 210UN | Up to 90kW | 1NON+1NC |
| NXC-225 | 225UN | 250UN | Up to 110kW | 1NON+1NC |
| NXC-265 | 265UN | 300UN | Up to 132kW | 1NON+1NC |
| NXC-300 | 300UN | 350UN | Up to 160kW | 1NON+1NC |
| NXC-370 | 370UN | 400UN | Up to 200kW | 1NON+1NC |
| NXC-400 | 400UN | 450UN | Up to 220kW | 1NON+1NC |
| NXC-500 | 500UN | 560UN | Up to 250kW | 1NON+1NC |
| NXC-630 | 630UN | 700UN | Up to 315kW | 1NON+1NC |
2.2 Core Models of Other Series
| Série | Modèles de base | Plage actuelle | Principales fonctionnalités |
| NC1 | NC1-09/12/18/25/32/40 /50/65/80/95 | 9UN ~ 95A | Compact, économique |
| NC2 | NC2-09~150 | 9A~150A | Standard design, versatile |
| NC8 | NC8-06~100 | 6UN ~ 100A | Faible puissance, long mechanical life |
| CJX2 | CJX2-09~95 | 9UN ~ 95A | Mounting compatible with Schneider LC1-D |
| CJ20 | CJ20-10~630 | 10UN ~ 630A | Capacité de charge de courant élevée |
| CJ19 | CJ19-16~100 | 16UN ~ 100A | Special arc quenching for capacitor switching |
- Cross-Brand Reference for CHINT Contactors
3.1 General Contactor Cross Reference (AC-3, 380V)
| CHINT | Schneider | Siemens | ABB | Délicieux | Functional Compatibility |
| NXC-06 | LC1D0610M5C | 3RT2015-1AP00 | A6-30-10 | CJX2-0610 | Entièrement compatible, minor dimensional differences |
| NXC-09 | LC1D0910M5C | 3RT2016-1AP00 | A9-30-10 | CJX2-0910 | Entièrement compatible, minor dimensional differences |
| NXC-12 | LC1D1210M5C | 3RT2017-1AP00 | A12-30-10 | CJX2-1210 | Entièrement compatible, minor dimensional differences |
| NXC-18 | LC1D1810M5C | 3RT2026-1AP00 | A18-30-10 | CJX2-1810 | Entièrement compatible, minor dimensional differences |
| NXC-25 | LC1D2510M5C | 3RT2027-1AP00 | A26-30-10 | CJX2-2510 | Entièrement compatible, minor dimensional differences |
| NXC-32 | LC1D3210M5C | 3RT2036-1AP00 | A30-30-10 | CJX2-3210 | Entièrement compatible, minor dimensional differences |
| NXC-40 | LC1D4010M5C | 3RT2037-1AP00 | A40-30-10 | CJX2-4010 | Entièrement compatible, minor dimensional differences |
| NXC-50 | LC1D5010M5C | 3RT2040-1AP00 | A50-30-10 | CJX2-5010 | Entièrement compatible, minor dimensional differences |
| NXC-65 | LC1D6510M5C | 3RT2046-1AP00 | A63-30-10 | CJX2-6510 | Entièrement compatible, minor dimensional differences |
| NXC-80 | LC1D8010M5C | 3RT2056-1AP00 | A75-30-10 | CJX2-8010 | Entièrement compatible, minor dimensional differences |
| NXC-95 | LC1D9510M5C | 3RT2066-1AP00 | A95-30-10 | CJX2-9510 | Entièrement compatible, minor dimensional differences |
| NXC-115 | LC1D11510M5C | 3RT2076-1AP00 | A110-30-10 | CJX2-11510 | Generally compatible, mounting may need adjustment |
| NXC-150 | LC1D15010M5C | 3RT2086-1AP00 | A145-30-10 | CJX2-15010 | Generally compatible, mounting may need adjustment |
3.2 Brand Technical Comparison
| Marque | Caractéristiques techniques | Strengths | Price Position |
| CHINT | Modular Kunlun design, bobine de faible puissance, long-life contacts | Industrie générale, building electrics | Mid-low, rentable |
| Schneider | TeSys series, intelligent control, rich communication | High-end automation, critical loads | Mid-high, leading tech |
| Siemens | 3RT series, haute fiabilité, integrated protection | Industrie 4.0, smart manufacturing | Haut, écurie |
| ABB | Modulaire, high noise immunity, eco-friendly materials | Industrie lourde, nouvelle énergie, transit | Haut, premium performance |
| Délicieux | CJX2 compatible with CHINT | PME, civil installations | Faible, abordable |
- Sélection & Directives de remplacement
4.1 Paramètres de sélection clés
- Courant nominal (C'est à dire): Select according to load; for motors, Ie ≥ 1.2 × courant nominal du moteur.
- Tension de bobine: Must match control system (AC/DC not interchangeable).
- Fréquence de fonctionnement: Pour >1200 opérations/heure, use long-life models.
- Contacts auxiliaires: Choose based on control logic (default 1NO+1NC).
- Montage: Rail DIN standard de 35 mm; high-current models may use bolt mounting.
4.2 Cross-Brand Replacement Notes
- Compatibilité mécanique
NXC mostly compatible with Schneider LC1-D mounting, but hole positions differ slightly.
Models above 100A vary greatly; brackets may need modification.
- Electrical compatibility
Coil voltage and frequency must match exactly.
Auxiliary contact ratings differ (CHINT ~5A, some Schneider ~10A).
Short-circuit coordination with fuses/circuit breakers should be rechecked.
- Performance differences
NXC: durée de vie mécanique 1.2 million, durée de vie électrique 100,000 (AC-3).
Premium Schneider/Siemens models reach 200,000 electrical cycles for ultra-frequent use.
4.3 NXC vs CJX2 Replacement
| CHINT CJX2 | Equivalent NXC | Upgrade Benefits |
| CJX2-09 | NXC-09 | Smaller, puissance inférieure, durée de vie plus longue |
| CJX2-12 | NXC-12 | Smaller, puissance inférieure, durée de vie plus longue |
| CJX2-18 | NXC-18 | Smaller, puissance inférieure, durée de vie plus longue |
| CJX2-25 | NXC-25 | Smaller, puissance inférieure, durée de vie plus longue |
| CJX2-32 | NXC-32 | Smaller, puissance inférieure, durée de vie plus longue |
| CJX2-40 | NXC-40 | Smaller, puissance inférieure, durée de vie plus longue |
| CJX2-50 | NXC-50 | Smaller, puissance inférieure, durée de vie plus longue |
| CJX2-65 | NXC-65 | Smaller, puissance inférieure, durée de vie plus longue |
| CJX2-80 | NXC-80 | Smaller, puissance inférieure, durée de vie plus longue |
| CJX2-95 | NXC-95 | Smaller, puissance inférieure, durée de vie plus longue |
- Quick Motor Selection Table
| Puissance du moteur (kW) | Courant nominal (UN) | Recommended CHINT | Schneider | Siemens | ABB |
| 2.2 | 5 | NXC-06 | LC1D0610 | 3RT2015 | A6-30-10 |
| 3 | 6.5 | NXC-09 | LC1D0910 | 3RT2016 | A9-30-10 |
| 5.5 | 12 | NXC-12 | LC1D1210 | 3RT2017 | A12-30-10 |
| 7.5 | 16 | NXC-18 | LC1D1810 | 3RT2026 | A18-30-10 |
| 11 | 23 | NXC-25 | LC1D2510 | 3RT2027 | A26-30-10 |
| 15 | 32 | NXC-32 | LC1D3210 | 3RT2036 | A30-30-10 |
| 18.5 | 39 | NXC-40 | LC1D4010 | 3RT2037 | A40-30-10 |
| 22 | 47 | NXC-50 | LC1D5010 | 3RT2040 | A50-30-10 |
| 30 | 63 | NXC-65 | LC1D6510 | 3RT2046 | A63-30-10 |
| 37 | 78 | NXC-80 | LC1D8010 | 3RT2056 | A75-30-10 |
| 45 | 94 | NXC-95 | LC1D9510 | 3RT2066 | A95-30-10 |
CHINT contactors cover a full range from 6A to 630A. The NXC (Kunlun) series offers greatly improved performance, reliability and compatibility, and can directly replace the CJX2 series and equivalent products from other brands. Pour le remplacement entre marques, verify rated current, tension de bobine, mounting dimensions and auxiliary contact configuration to ensure stable system operation.
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires


















NH42-63-318x560.png)