CHINT NXC-65A AC Contactor - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

CHINT NXC-65A AC Contactor - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

contacteur/

CHINT NXC-65A AC Contactor

  Model Segment Description NXC Product series code: CHINT KunLun series AC contactor, upgraded replacement for traditional CJX2 series 65 Rated operational current: 65UN (sous AC-3, 400V) A Configuration code: Modèle standard (no suffix = standard; suffix /N = reversing type) Common Suffix Coil voltage code: 220V / 380V / 110V / 24V, par exemple. NXC-65 ...

  • Détails du produit

 

Segment de modèleDescription
NXCProduct series code: CHINT KunLun series AC contactor, upgraded replacement for traditional CJX2 series
65Rated operational current: 65UN (sous AC-3, 400V)
UNCode de configuration: Modèle standard (no suffix = standard; suffix /N = reversing type)
Common SuffixCoil voltage code: 220V / 380V / 110V / 24V, par exemple. NXC-65 220V

Full Model Example:

NXC-65 220V 50Hz = CHINT KunLun 65A AC contactor, coil voltage 220V, 50Hz, configuration standard

Typical Order No.: 710010100000281 (NXC-65 220V 50Hz, 1NON+1NC)

  1. Main Technical Data
CatégorieCaractéristiquesRemarques
Informations de base
Marque / SérieCHINT Electric / KunLun NXC SeriesStructure compacte, direct replacement for CJX2-65
Type de produit3-phase AC ContactorFor frequent motor starting & remote circuit switching
Normes de conformitéGB/T 14048.1 / CEI 60947-1, GB/T 14048.4 / CEI 60947-4-1International certified, sûr et fiable
Electrical Data
Courant de fonctionnement nominal (C'est à dire)65UN (AC-3, 400V)Main contact rated current
Tension de fonctionnement nominale (Ue)380V / 400V (50Hz)Standard industrial grid voltage
Tension d'isolation nominale (Interface utilisateur)690VMax withstand voltage of insulation system
Tension de tenue aux impulsions nominale (Ump)8kVOvervoltage protection capability
Tension de la bobine de commandeOptional AC 24V / 36V / 110V / 220V / 380VSelected according to control system
Coil Frequency50 / 60HzGlobal grid compatibility
Rated Operating Frequency1200 cycles/h (AC-3)High frequent operation capability
Capacité de coupure10× rated currentShort-circuit withstand capability
Configuration des contacts
Contacts principaux3NON (3-pole normally open)Standard for main power circuit
Contacts auxiliaires1NON + 1Caroline du NordExpandable on request
Auxiliary Contact Rating5UN / 220V etFor control signal circuits
Caractéristiques physiques
Dimensions (L×H×P)90mm × 150mm × 105mmCompact, space-saving
PoidsEnviron. 0.8kilosLightweight for easy installation
MontageRail DIN standard de 35 mm / montage à visSnap-on design, fast assembly
Classe de protectionIP20Suitable for cabinet installation
Température de fonctionnement-30℃ ~ +60℃Wide temperature range for harsh environments
Température de stockage-25℃ ~ +40℃Suitable for transportation & warehouse storage
Electromagnetic Performance
Puissance de la bobineEnviron. 180Virginie (pick-up) / 25Virginie (holding)Faible consommation d'énergie, économie d'énergie
Drop-out Voltage30% ~ 70% de tension nominaleReliable disconnection
Système électromagnétiqueOptimized silicon steel lamination (32-piece core)Smooth closure, faible bruit & loss
Caractéristiques de sécurité
CertificationsCE, CCCDomestique & international compliance
Arc ExtinctionMulti-channel magnetic blow-out arc suppressionHigh breaking performance
Fonctions de protectionSurintensité, surchauffe, undervoltage protectionComprehensive equipment & circuit protection
  1. Accessory List
AccessoireModèleFonctionMounting Position
Auxiliary Contact BlockAX-3M/20 (2NON), AX-3M/02 (2Caroline du Nord), AX-3M/11 (1NON+1NC)Expand auxiliary contacts for complex logicTop front
Time Delay ModuleF5-08 (0.1~30s), F5-11 (0.1~180s)On-delay / off-delay controlHaut
Surge SuppressorSR2-220, SR2-380Suppress coil surge voltageBas
Verrouillage mécaniqueNXC-ILPrevent phase short circuit for reversing contactor (NXC-65/N)Side
Mounting Rail35Rail DIN standard de mmFixed installationInside control cabinet
Terminal Protection CoverStandard equippedAnti-touch protectionMain & auxiliary terminals
Mounting ScrewsM4×12mmFixation par visBase mounting holes
Operation ManualÉlectronique / hard copyInstallation, commissioning & maintenance guide
Coil ConnectorFacultatifFast coil wiring & replacementCoil terminal side
  1. Cross-Brand Equivalent & Remplacement
MarqueSérieModèleCourant nominalDifférencesCompatibilité de remplacement
CHINTCJX2CJX2-651165UNOld generation; NXC is fully upgraded versionDirect full replacement (same mounting size)
SchneiderTeSys DLC1D65M7C65UNImport brand, coût plus élevé, similar functionsHaut (verify mounting & contacts auxiliaires)
Siemens3RT3RT2026-1BB4065UNConception modulaire, hot-swap supportMoyen (different dimension & câblage)
ABBDEAF65-30-1165UNWide-voltage coil, global applicationMoyen (needs position adjustment)
MitsubishiS-NS-N6565UNCompact Japanese design, moderate priceMoyen (different terminal layout)
ChangshuCK3CK3-6565UNDomestic equivalent, same performanceHaut (fully compatible size & montage)
  1. Fonctions principales & Applications

Fonctions principales

  1. High-efficiency Electromagnetic System: Optimized core structure for stable closure, low noise and low energy consumption.
  2. Highly Reliable Arc Suppression: Magnetic blow-out technology with 10× rated breaking capacity for higher safety.
  3. Expansion flexible: Supports auxiliary contacts, timer modules and surge suppressors for customized control.
  4. Installation facile: Snap-on DIN rail mounting for fast assembly and maintenance.
  5. Wide Temperature Adaptation: Stable operation from -30℃ to +60℃ for various industrial environments.

Applications typiques

  1. Contrôle du moteur: Frequent start/stop/reverse of 3-phase asynchronous motors (environ. 30kW @ 400V).
  2. Automatisation industrielle: Production lines, convoyeurs, les fans, water pumps and general machinery.
  3. Building Electrical: Systèmes CVC, fire water pumps, elevator auxiliary circuits.
  4. Machine Tools: Spindle control for milling machines, drilling machines and small machining centers.
  5. Power Distribution: Combiné avec des relais de surcharge thermique (série NR2) for complete motor protection starters.
  6. Notes complémentaires
  7. Product Upgrade: The NXC KunLun series fully replaces the traditional CJX2 series with improved mechanical structure, electromagnetic performance and expandability.
  8. Lignes directrices de sélection:

Select current rating according to motor power (65A matches approx. 30kW motor).

Confirm coil voltage (220V / 380V most common).

Expand auxiliary contacts via AX series modules if signal points are insufficient.

  1. Conseils d'entretien:

Regularly check contact wear; replace contacts when excessive contact resistance occurs.

Keep the contactor clean from dust and moisture.

Apply periodic energization (1–2 times monthly) for long-term idle equipment to prevent coil dampness.

CHINT Contactor Full Series List

  1. Product Series Overview
SériePositionnementPlage actuelleCaractéristiquesReplacement Relation
NXCKunLun Main Series6A ~ 630ACompact, modular, high cost-performanceFull replacement for CJX2
NC5High-performance Intelligent Series9A ~ 630ASmart control, économie d'énergie, haute stabilitéHigh-end alternative to NXC
CJX2Classic Traditional Series9A ~ 95AMature model, rentableGradually phased out by NXC
NXCFSlim Compact Series9A ~ 32AUltra-thin, space-savingSmall cabinet & compact installation
NC8Heavy-duty Industrial Series9A ~ 500AHigh mechanical life, strong arc resistanceFrequent start-stop working conditions
NXCCCapacitor Switching Contactor16A ~ 100AInrush current suppression, reactive power compensation dedicatedCapacitor bank control
NCH8Household & Building Series16A ~ 63ATaille miniature, building automationÉclairage, CVC & residential control
CJ40 / CJ20High-power Heavy Series100A ~ 630AHeavy-load design for large motorsHeavy industrial equipment
  1. NXC KunLun Series Main Model List (AC-3 400V)
Courant nominalStandard ModelReversing ModelStandard Aux. ContactMatched Motor PowerNuméro de commande.
6UNNXC-06M.1NON+1NC0.75kW710010100000276
9UNNXC-09NXC-09/N1NON+1NC1.5kW710010100000277
12UNNXC-12NXC-12/N1NON+1NC2.2kW710010100000278
18UNNXC-18NXC-18/N1NON+1NC3kW710010100000279
25UNNXC-25NXC-25/N1NON+1NC5.5kW710010100000280
32UNNXC-32NXC-32/N1NON+1NC7.5kW710010100000281
40UNNXC-40NXC-40/N1NON+1NC11kW710010100000282
50UNNXC-50NXC-50/N1NON+1NC15kW710010100000283
65UNNXC-65NXC-65/N1NON+1NC30kW710010100000284
80UNNXC-80NXC-80/N1NON+1NC37kW710010100000285
95UNNXC-95NXC-95/N1NON+1NC45kW710010100000286
100UNNXC-100NXC-100/N2NON+2NC55kW710010100000287
120UNNXC-120NXC-120/N2NON+2NC75kW710010100000288
160UNNXC-160NXC-160/N2NON+2NC90kW710010100000289
200UNNXC-200NXC-200/N2NON+2NC110kW710010100000290
250UNNXC-250NXC-250/N2NON+2NC132kW710010100000291
315UNNXC-315NXC-315/N2NON+2NC160kW710010100000292
400UNNXC-400NXC-400/N2NON+2NC200kW710010100000293
500UNNXC-500NXC-500/N2NON+2NC250kW710010100000294
630UNNXC-630ANXC-630A/N2NON+2NC315kW710010100000295
  1. NC5 High-performance Series

Model Rule

NC5-[Actuel][Taper][Tension de bobine]

– Taper: Standard / E=Economy / NE=Intelligent / F=Reversing

Plage actuelleStandardIntelligentReversingAux. ContactTension d'isolation
9A~38ANC5-09~38NC5NE-09~38NC5F-09~381NON+1NC690V
40A~100ANC5-40~100NC5NE-40~100NC5F-40~1001NON+1NC690V
115A~250ANC5-115~250NC5NE-115~250NC5F-115~2502NON+2NC1000V
315A~630ANC5-315~630NC5NE-315~630NC5F-315~6302NON+2NC1000V
  1. Classic CJX2 Series
ActuelModèleAux. ContactMatched Motor
9UNCJX2-0910 / 0901 / 09111NON / 1Caroline du Nord / 1NON+1NC1.5kW
12UNCJX2-1210 / 1201 / 12111NON / 1Caroline du Nord / 1NON+1NC2.2kW
18UNCJX2-1810 / 1801 / 18111NON / 1Caroline du Nord / 1NON+1NC3kW
25UNCJX2-2510 / 2501 / 25111NON / 1Caroline du Nord / 1NON+1NC5.5kW
32UNCJX2-3210 / 3201 / 32111NON / 1Caroline du Nord / 1NON+1NC7.5kW
40UNCJX2-4010 / 4001 / 40111NON / 1Caroline du Nord / 1NON+1NC11kW
50UNCJX2-5010 / 5001 / 50111NON / 1Caroline du Nord / 1NON+1NC15kW
65UNCJX2-6510 / 6501 / 65111NON / 1Caroline du Nord / 1NON+1NC30kW
80UNCJX2-8010 / 8001 / 80111NON / 1Caroline du Nord / 1NON+1NC37kW
95UNCJX2-9510 / 9501 / 95111NON / 1Caroline du Nord / 1NON+1NC45kW
  1. Other Special Series

NXCF Slim Series

ActuelModèleLargeurAux. Contact
9UNNXCF-0922.5mm1NON+1NC
12UNNXCF-1222.5mm1NON+1NC
16UNNXCF-1622.5mm1NON+1NC
25UNNXCF-2536mm1NON+1NC
32UNNXCF-3236mm1NON+1NC

NC8 Heavy-duty Series

ActuelModèlePoteauxDurée de vie mécanique
9A~38ANC8-09~383P.10 millions de cycles
40A~100ANC8-40~1003P.10 millions de cycles
115A~500ANC8-115~5003P/4P8 millions de cycles

NXCC Capacitor Contactor

ActuelModèleSuppression TypeCapacitor Rating
16UNNXCC-16Series resistor10kvar
25UNNXCC-25Series resistor15kvar
32UNNXCC-32Series resistor20kvar
40UNNXCC-40Series resistor25kvar
50UNNXCC-50Series resistor30kvar
63UNNXCC-63Series resistor40kvar
80UNNXCC-80Series resistor50kvar
100UNNXCC-100Series resistor60kvar

NCH8 Building / Household Contactor

ModèlePoteauxActuelApplication
NCH8-16M2P.16UNSmart home control
NCH8-25M2P.25UNAir conditioning control
NCH8-32M2P.32UNSmall water pump
NCH8-40M2P.40UNFloor heating system
NCH8-63M2P.63UNBuilding lighting
  1. Universal Accessories
AccessoireModèleApplicable Series
Auxiliary Contact BlockAX-3M SeriesNXC / NC5 / CJX2
Time Delay ModuleF5 SeriesFull series
Coil Surge SuppressorSR2 SeriesFull series
Verrouillage mécaniqueNXC-IL / NC5-ILReversing contactor
Relais de surcharge thermiqueNR2 / NR5 SeriesMotor protection combination
35mm Rail DINModèle standardFull cabinet-mounted contactors
  1. Sélection & Guide de remplacement
  2. Series Selection

Nouveau projet: Adopt NXC KunLun series as priority.

Intelligent control: Choose NC5NE intelligent contactor.

Compact cabinet: Use ultra-thin NXCF.

Reactive power compensation: Special NXCC capacitor contactor.

  1. Sélection actuelle

Rated current ≥ motor rated current × 1.1 (service normal).

Frequent operation ≥ motor current × 1.25.

  1. Tension de bobine

Match control circuit voltage: AC220V / AC380V most common; safety low-voltage 24V/36V optional.

  1. Contacts auxiliaires

Expandable via external auxiliary blocks when signal points are insufficient.

Reversing circuit must adopt mechanical interlock type.

Précédent:

Laisser une réponse

Laisser un message