NXC-185-380V (Numéro de commande: 710010100000343) Segment Meaning Description NXC Product Series CHINT Kunlun series AC contactor, upgraded compact structure replacing traditional CJX2 series 185 Rated Current Rated operational current of main contact: 185UN (AC-3, 400V) 380V Coil Voltage Rated control coil voltage: AC380V, standard frequency 50Hz Supplementary Specifications: 3-pôle (3P.), 3 normally-open main contacts, 2NO+2NC auxiliary ...

  • Détails du produit

NXC-185-380V (Numéro de commande: 710010100000343)

SegmentSignificationDescription
NXCSérie de produitsCHINT Kunlun series AC contactor, upgraded compact structure replacing traditional CJX2 series
185Courant nominalRated operational current of main contact: 185UN (AC-3, 400V)
380VTension de bobineRated control coil voltage: AC380V, standard frequency 50Hz

Supplementary Specifications: 3-pôle (3P.), 3 normally-open main contacts, 2Contacts auxiliaires NO+2NC, standard mounting type

  1. Paramètres de spécification de base
CatégorieDonnées techniquesRemarques
Basic Properties
Type de produitElectromagnetic AC ContactorSérie Kunlun, replacement for CJX2-1850
Normes applicablesGB/T 14048.4 / CEI 60947-4-1Compliant with GB 21518 safety standard
Tension d'isolation nominale1000VUnified standard for specifications above 120A
Tension de fonctionnement nominale220V~690VCompatible with various industrial power supply systems
Paramètres électriques
Courant opérationnel nominal (C'est à dire)185UN (AC-3, 400V)Matches motor power around 90kW
Capacité de fabrication nominale10×C'est à dire (AC-3)1850UN, reliable load switching
Capacité de coupure nominale8×C'est à dire (AC-3)1480UN, safe fault current interruption
Paramètres de la bobineAC380V, 50Hz, power approx. 170VirginiePick-up/holding power ratio about 3:1
Contacts auxiliaires2NON+2NC, rated current 5ASignal transmission for control circuits
Paramètres mécaniques
Numéro de pôle3P. (3 AUCUN contact principal)Configuration standard, 4P version optional
Méthode de montageRail DIN standard de 35 mm / montage à visFits mainstream control cabinets
Matériau du boîtierFlame-retardant engineering plasticUL94 V0 flame resistance grade
Degré de protectionIP20Finger-touch safe, indoor cabinet installation only
Durée de vie mécanique10,000,000 opérationsLongue durée de vie, low maintenance frequency
Durée de vie électrique1,000,000 opérations (AC-3)Convient aux opérations de démarrage et d'arrêt fréquentes
Paramètres environnementaux
Température de fonctionnement-30°C ~ +70°CWide temperature range for harsh industrial conditions
Température de stockage-40°C ~ +85°CMeets storage and transportation requirements
Humidité relative5%~95 %, sans condensationAdaptable to humid working environment
Altitude≤2000mDerating required for higher altitude
  1. Cross-brand Replacement Comparison
MarqueModèleFonctionnalités similairesDifférences
CHINTNXC-185-380VReference modelSérie Kunlun, rentable, preferred domestic replacement
SchneiderLC1D18500Q7185UN, 3P., 380Bobine VPrix ​​plus élevé, 1NO+1NC auxiliary contacts
ABBA185-30-11185UN, 3P., 380Bobine V1NO+1NC auxiliary contacts, different mounting dimensions
Siemens3RT2036-1AP00185UN, 3P., 380Bobine VHigh price, réponse rapide, ideal for precision control
DÉLIXICDM3-185185UN, 3P., 380Bobine VAlternative nationale, similar price, slightly lower performance

Notes de remplacement:

  1. Confirm identical coil voltage, pole number and auxiliary contact configuration before replacement
  2. Verify mounting hole compatibility among different brands
  3. Check derating curve matching for high altitude and special environments
  4. Matching CHINT NXR thermal overload relay is recommended for optimal protection
  5. Liste des modèles de la série complète (Core NXC Models)
Modèle Courant nominal Tension de bobine Contact auxiliaire Pôle Numéro de commande.
NXC-06-220V 6UN AC220V 1NON+1NC 3P.710010100000001
NXC-12-380V 12UN AC380V 1NON+1NC 3P.710010100000002
NXC-18-220V 18UN AC220V 1NON+1NC 3P.710010100000003
NXC-25-380V 25UN AC380V 1NON+1NC 3P.710010100000004
NXC-32-220V 32UN AC220V 1NON+1NC 3P.710010100000005
NXC-40-380V 40UN AC380V 1NON+1NC 3P.710010100000006
NXC-50-220V 50UN AC220V 1NON+1NC 3P.710010100000007
NXC-65-380V 65UN AC380V 1NON+1NC 3P.710010100000008
NXC-80-220V 80UN AC220V 2NON+2NC 3P.710010100000009
NXC-100-380V 100UN AC380V 2NON+2NC 3P.710010100000305
NXC-120-220V 120UN AC220V 2NON+2NC 3P.710010100000306
NXC-150-380V 150UN AC380V 2NON+2NC 3P.710010100000307
NXC-185-380V 185UN AC380V 2NON+2NC 3P.710010100000343
NXC-225-380V 225UN AC380V 2NON+2NC 3P.710010100000344
NXC-265-380V 265UN AC380V 2NON+2NC 3P.710010100000345

Model Extension Rules:

Suffix M: Contacteur réversible (par exemple. NXC-25M-220V)

Suffix 4P: 4-contacteur de pôle (par exemple. NXC-65-4P-380V)

Suffix Z: Bobine CC (par exemple. NXC-18-24Z)

Auxiliary contact expansion: Max 6NO+6NC with F4-XX auxiliary contact block

  1. Défauts courants & Dépannage
Phénomène de défautCauses possiblesSolutions
Le contacteur ne parvient pas à s'enclencher1. Abnormal coil voltage1. Verify stable 380V power supply
2. Open control circuit2. Check wiring and fuse
3. Bobine brûlée3. Tester la résistance de la bobine (normal ~800Ω), replace damaged coil
4. Mechanical jam4. Clean iron core and reset spring
Bruit fort après l'arrivée1. Oil contamination on core surface1. Clean contact surface of iron core
2. Anneau de court-circuit cassé2. Replace iron core or short-circuit ring
3. Sous-tension3. Assurer une tension ≥85 % de la valeur nominale
Overheated / burned contacts1. Excessive load current1. Upgrade to higher capacity model
2. Poor contact performance2. Clean contacts and adjust contact pressure
3. Frequent switching3. Optimize control logic to reduce unnecessary switching
4. Failed arc suppression4. Inspect and maintain arc shield
Malfunction of auxiliary contacts1. Contacter l'oxydation1. Polish and clean contacts
2. Contacter l'ablation2. Replace auxiliary contact assembly
3. Câblage lâche3. Fasten terminal connections
Overheating and burnt coil1. Surtension1. Keep voltage within rated range
2. Excessive operation frequency2. Reduce switching frequency or adopt AC-4 type contactor
3. Température ambiante élevée3. Improve ventilation condition
4. Stuck iron core4. Ensure flexible mechanical movement
  1. Conformité du fret aérien & Certifications
  2. Certifications

Certification CE, compliant with EU Machinery Directive

cULus certification complying with North American safety standards

CCC compulsory certification of China

RoHS environmental compliance

  1. Air Transport Regulations

No built-in lithium battery or super capacitor, classified as ordinary industrial electrical equipment

Marchandises non dangereuses, conforms to IATA DGR Class 9 exigences

Standard industrial packaging, maximum 20 units per carton to avoid collision damage

Recommended marks: FRAGILE, ELECTRICAL EQUIPMENT, KEEP DRY

  1. Environnement d'application & Adaptation

Scénarios applicables

Contrôle de moteur industriel: Commencer, stop and reverse control of three-phase asynchronous motors below 90kW

Ventilateur & Water Pump System: CVC, industrial circulating water and sewage aeration equipment control

Compressor Control: Heavy-duty air and refrigeration compressors for AC-3 working condition

Automatic Production Line: Core component for sequence control and interlock protection

Building Electrical System: Climatisation centrale, fire water pump and elevator room equipment control

Machines minières: Remote control and protection for belt conveyors and crushers

Metallurgical Equipment: Electrical control system for small rolling mills and furnace auxiliary units

Scénarios inappropriés

DC circuit control (Select dedicated NXC-Z series DC contactors)

High-frequency operation over 1200 cycles per hour (AC-4 contactor or solid state relay recommended)

Use above 2000m altitude without power derating

Severe vibration environment over 5g without damping measures

Corrosive gas environment without anti-corrosion protection

  1. Application Cases

Cas 1: Central Air Conditioning Control of Large Shopping Mall

Application: Control of 3 sets 90kW water chillers and 4 sets 75kW cooling tower fans

Challenges: 20-30 daily start-stop cycles, high reliability and energy saving requirement

Solution: NXC-185-380V + NXR-185 thermal overload relay + intelligent PLC control system

Résultat: Trouble-free operation for 2 années, 30% energy saving with frequency conversion, 50% maintenance cost reduction

Cas 2: Conveyor System for Auto Parts Production Line

Application: 12 belt conveyor lines with 75kW driving motor each, sequential start-stop and interlock protection

Challenges: Multi-motor synchronous control, frequent forward/reverse rotation, oily environment

Solution: NXC-185-380V for main drive + NXC-65-380V for auxiliary drive + safety relay

Résultat: Precise synchronous operation, IP20 protection against oil contamination, mechanical life up to 8 millions de cycles

  1. Lignes directrices de sélection

Règles rapides

Courant nominal: NXC-X ranging 6~630A, matching motor power about X/2 kW

Standard coil voltage: 220V / 380V; optional 110V / 24V / 48V

Contact auxiliaire: 1NO+1NC for ≤80A; 2NO+2NC for ≥100A

Montage: Universal 35mm DIN rail for mainstream cabinets

Classe de protection: IP20, indoor cabinet use only, outdoor exposed installation prohibited

Specific Application Scenarios of NXC185-380V

  1. Contrôle du moteur

Commencer, stop and reverse control of three-phase asynchronous motors below 90kW

Continuous operation control of constant-load equipment including fans, pumps and compressors

Motor control with operation frequency ≤1200 cycles per hour

  1. Industrial Automation System

Sequence control and interlock protection of production line facilities

Peripheral equipment control of robot workstations

Stacker and conveyor control in automated warehouses

  1. Construction & Infrastructure

Water chiller and cooling tower control for commercial central air conditioning

Fire water pump and exhaust fan control of high-rise buildings

Ventilation system control of underground parking lots

  1. Énergie & Protection de l'environnement

Aeration equipment and sludge pump control in sewage treatment plants

Switch control of small photovoltaic inverters and energy storage systems

Control system of waste disposal equipment

  1. Exploitation minière & Métallurgie

Belt conveyor and crusher control in mines

Auxiliary equipment control of small metallurgical furnaces

Electrical control system of mineral processing facilities

Restricted Application

DC circuit application

Operation frequency exceeding 1200 cycles per hour

Underrated use at altitude over 2000m

Heavy vibration environment without damping measures

Corrosive gas environment without protective treatment

Précédent:

Laisser une réponse

Laisser un message