Danfoss FC-051P18KT4E20H3BXCXXXSXXX Inverter - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Danfoss FC-051P18KT4E20H3BXCXXXSXXX Inverter - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

onduleur solaire/

Danfoss FC-051P18KT4E20H3BXCXXXSXXX Inverter

Doté d'une structure compacte, high-efficiency control and reliable performance, Danfoss FC-051P18KT4E20H3BXCXXXSXXX inverter delivers outstanding performance in fields including fans & pompes à eau, manutention des matériaux, food & textile industry, traitement de l'eau, achieving an average energy-saving rate of 30-50%. It also extends service life of equipment, improves product quality and cuts maintenance costs. Reasonable configuration shall be conducted ...

  • Détails du produit

Doté d'une structure compacte, high-efficiency control and reliable performance, Danfoss FC-051P18KT4E20H3BXCXXXSXXX onduleur delivers outstanding performance in fields including fans & pompes à eau, manutention des matériaux, food & textile industry, traitement de l'eau, achieving an average energy-saving rate of 30-50%. It also extends service life of equipment, improves product quality and cuts maintenance costs. Reasonable configuration shall be conducted according to load characteristics, ambient conditions and control requirements during model selection to maximize its technical advantages.

  1. Définition du code modèle
CodeSignificationDescription détaillée
FC-051Code de sérieVLT® Micro Drive FC-51 Compact General-purpose Inverter Series
P18KPuissance nominaleMatched motor power: 18.5kW / 25HP
T4Power Supply Spec.T=Three-phase input; 4=380-480VAC voltage class
E20Classe de protectionProtection IP20, chassis mounting type
H3RFI FilterEquipped with RFI Class A1/B (C1) filtre
BBrake UnitBuilt-in brake chopper
XLocal Control PanelWithout local control panel (LCP to be ordered separately)
CPCB CoatingCoated printed circuit board for higher reliability in harsh environments
XPower OptionStandard power configuration without special options
XAdapter AStandard cable entry
XAdapter BNo extra adapters
SXXXSoftware VersionLatest standard software version
M5Taille du cadreM5 frame (corresponding to 18.5kW power grade)
Numéro de commande.132F0060Official unique identification code
  1. Spécifications techniques de base
CatégorieSpécificationRemarques
Paramètres de base
Puissance nominale18.5kW / 25HPMatched motor power
Courant de sortie nominal37UN (Heavy-duty) / 34UN (Light-duty)Current values for different load types
Tension d'entrée3-phase 380-480VACAllowable fluctuation: ±10%
Input Frequency50/60HzAuto-adaptive
Tension de sortie0~100% of input voltageVaries with frequency
Output Frequency0-200Hz (VVC+ Mode) / 0-400Hz (U/f Mode)Contrôle vectoriel / V/f ratio control
Control Features
Mode de contrôleVVC+ (Voltage Vector Control), U/f ControlClosed-loop vector control available (encoder optional)
Capacité de surcharge150% rated current for 60 secondesStandard overload protection
Acc/Dec Time0.1~3600sAcceleration and deceleration time set independently
Entrée numérique5 entrées programmablesSupport PNP/NPN logic, 0-24VCC
Entrée analogique1 channel 0-10V/4-20mAProgrammable functions
Sortie relais2 chaînes (1 NON + 1 Caroline du Nord)Max switching capacity: 250VAC/2A
Physical Properties
Degré de protectionIP20Chassis mounting
Méthode de refroidissementRefroidissement naturel + forced air coolingM5 frame with built-in fan
Température ambiante-20°C ~ +50°CDerating operation required above 40°C
Humidité relative5%~95 %, sans condensationStandard industrial environment requirement
PoidsEnviron. 9.98kilos (net weight)Environ. 10.27kg with package
Attestation & Conformité
Certifications de sécuritéCE, UL, cUL, RoHSCompliant with EU Low Voltage Directive 2014/35/EU
EMC StandardDANS 55011 Classe AEMC requirement for industrial environment
ECCN CodeEU: Y901, US: 3A999.aExport control classification code
  1. Full Series Model List (380-480V Three-phase)
PouvoirModèleNuméro de commandeCourant nominalTaille du cadre
0.37kWFC-051PK37T4E20H3BXCXXXSXXX132F00011.1UNM1
0.75kWFC-051PK75T4E20H3BXCXXXSXXX132F00022.1UNM1
1.5kWFC-051P1K5T4E20H3BXCXXXSXXX132F00033.7UNM1
2.2kWFC-051P2K2T4E20H3BXCXXXSXXX132F00045.2UNM1
3.0kWFC-051P3K0T4E20H3BXCXXXSXXX132F00247.0UNM2
4.0kWFC-051P4K0T4E20H3BXCXXXSXXX132F00259.3UNM2
5.5kWFC-051P5K5T4E20H3BXCXXXSXXX132F002612.5UNM3
7.5kWFC-051P7K5T4E20H3BXCXXXSXXX132F002717.0UNM3
11kWFC-051P11KT4E20H3BXCXXXSXXX132F005925.0UNM4
15kWFC-051P15KT4E20H3BXCXXXSXXX132F006032.0UNM5
18.5kWFC-051P18KT4E20H3BXCXXXSXXX132F006037.0UNM5
22kWFC-051P22KT4E20H3BXCXXXSXXX132F006145.0UNM5
  1. Cross-brand Equivalent Model Comparison
Danfoss FC-051P18KT4E20H3BXCXXXSXXXSiemensSchneiderABBReplacement Suggestion
18.5kW/37A/380-480VSINAMICS G120C 6SL3210-1KE22-6UF1Altivar 320 ATV320U40N4ACS150-03E-04A1-4Similar functions, communication protocols need matching
Mode de contrôle: VVC+/U/fContrôle vectorielContrôle vectorielDTC Direct Torque ControlABB features fastest dynamic response; Schneider offers higher cost performance
Built-in brake chopperExternal accessory requiredIntégréExternal accessory requiredDanfoss features more flexible configuration
RFI Class A1/BOptional Class A/BClasse A intégréeOptional Class A/BMeet industrial EMC standards
Without LCP (acheté séparément)Standard BOP-2Standard keypadStandard assistant control panelSiemens owns friendliest operation interface

Obsolete Replacement: FC-051 is still mainstream without direct discontinued substitutes. For function upgrade, choose Danfoss FC-301 series with richer functions and support for PROFINET and other advanced communication protocols.

  1. Environnement d'application & Cas industriels

Scénarios applicables

Ventilateurs & Water Pumps: Systèmes CVC, water treatment plants, cooling towers, realize 30%-50% energy saving via variable frequency speed regulation

Material Conveying: Convoyeurs, palans, machines d'emballage, achieve smooth start/stop and precise speed control

Nourriture & Beverage Industry: Filling lines, labeling machines, sterilization equipment, adapt to humid environment with PCB coating protection

Machines textiles: Spinning machines, weaving machines, satisfy low-speed high-torque demands

Small Machine Tools: Drilling machines, fraiseuses, broyeurs, realize accurate speed adjustment

Non-recommended Scenarios

Heavy-duty impact loads: Such as crushers and punch presses (FC-302 series is recommended)

Explosion-proof occasions: Special explosion-proof models required (FC-051 has no explosion-proof certification)

Altitude above 1000m: Derating operation needed (1% power reduction per 100m rise)

Ambient temperature over 50°C: Additional cooling measures or derating operation required

Cas d'application typiques

  1. Constant Pressure Water Supply System

Adopt FC-051P18KT4 to control 18.5kW water pump with closed-loop control via pressure sensor, realizing 40% économie d'énergie, stabilizing pipeline pressure and extending equipment service life.

  1. Packaging Production Line

Four sets of FC-051 series inverters including 18.5kW model are applied to control conveyor speed for synchronous operation, lowering product damage rate and greatly reducing downtime frequency.

  1. Central Air-conditioner Fan System

Applied in shopping mall air conditioner fans to adjust rotating speed automatically by ambient temperature, économiser sur 28,000 RMB electricity fee annually per unit and reducing operating noise.

  1. Air Freight Compliance & Attestation

Air Freight Regulations

Built-in Capacitor: Equipped with DC bus electrolytic capacitors without lithium batteries, UN38.3 test report is not required

Transport Classification: Non-dangerous goods, deliverable as common electronic products by air

Packaging Requirements

Power off completely with capacitors discharged for more than 5 minutes

Fixed in anti-static package to avoid collision damage

Mark with labels ofFragile Electronic Equipment” et “This Side Up

Main Certifications

Code d'erreurFault DescriptionCauses possiblesÉtapes de dépannage
AL16Output Short Circuit1. Motor winding short circuit1. Cut off power and disconnect UVW motor wiring
2. Damaged motor cable2. Test three-phase motor winding resistance balance
3. Power module failure3. Check cable insulation condition
4. Reset and test inverter output under no-load state
AL10Motor Overheating1. Overloaded operation1. Confirm actual load within rated range
2. Poor motor heat dissipation2. Clean motor heat sink
3. Temperature sensor failure3. Inspect PT100 and thermistor connection
AL51DC Bus Undervoltage1. Low input voltage1. Measure input voltage (normal range: 342-528V)
2. Phase loss of power supply2. Check three-phase power balance
3. Rectifier bridge failure3. Detect rectifier module output
AL71Inverter Overheating1. Température ambiante trop élevée1. Ensure ambient temperature ≤40°C
2. Cooling fan malfunction2. Check fan running status
3. Radiator blockage3. Remove dust and sundries on radiator
AL52Input Phase Loss1. Power supply phase missing1. Measure three-phase input voltage
2. Loose wiring terminals2. Fasten terminal wiring
3. Faulty input contactor3. Test contactor switching performance
  1. Défauts courants & Guide de dépannage
Nom de l'accessoireModèleFonctionNecessity
Local Control PanelLCP 12On-site parameter setting and monitoringRecommandé (not standard equipped)
Brake ResistorMCE 101-0300Dissipate regenerative energy and prevent overvoltageMandatory for models with code B
Module de communicationFC CAN/ProfibusRealize industrial network connectionOptional on demand
Input FilterH3 Upgrade KitUpgrade EMC performance to Class BRecommended for electromagnetic sensitive occasions
Protective CoverFC-051-IP40Upgrade protection class to IP40Recommended for dusty working sites
  1. Règles de sélection & Quick Tips
  2. Correspondance de puissance: Inverter rated current ≥ 1.1 times motor rated current to cope with starting impact
  3. Voltage Confirmation: Input voltage shall stay within 380-480V with fluctuation ≤±10%
  4. Brake Configuration: Models with code B have built-in brake choppers, external brake resistors required (power ≥ 30% of motor power)
  5. Heat Dissipation: Keep ventilation space over 10cm for M5 frame; déclasser 10% power per 5°C rise above 40°C
  6. Expansion des communications: Additional Modbus/Profibus modules need separate purchase for network communication
  7. Recommended Key Accessories
Nom de l'accessoireModèleFonctionNecessity
Local Control PanelLCP 12On-site parameter setting and monitoringRecommandé (not standard equipped)
Brake ResistorMCE 101-0300Dissipate regenerative energy and prevent overvoltageMandatory for models with code B
Module de communicationFC CAN/ProfibusRealize industrial network connectionOptional on demand
Input FilterH3 Upgrade KitUpgrade EMC performance to Class BRecommended for electromagnetic sensitive occasions
Protective CoverFC-051-IP40Upgrade protection class to IP40Recommended for dusty working sites

Full Analysis on Application Cases of Danfoss FC-051P18KT4E20H3BXCXXXSXXX (18.5kW) Onduleur

  1. Overview of Core Application Fields

This 18.5kW/37A/380-480V inverter with built-in brake chopper and coated PCB board is widely applied relying on VVC+ vector control, IP20 protection and high cost performance:

HVAC industry: Central air conditioner fans, cooling towers, pompes à eau

Traitement de l'eau: Alimentation en eau à pression constante, aeration tanks, sludge return pumps

Manutention des matériaux: Heavy-duty conveyors, ascenseurs, logistics sorting lines

Food industry: Filling machines, sterilization equipment, machines d'emballage

Textile industry: Spinning machines, weaving machines, setting machines

Building material machinery: Mélangeurs, light-duty crushers

  1. Detailed Introduction of Five Typical Application Cases

Cas 1: Constant Pressure Water Supply for Residential Communities

Original power frequency water supply system suffered from severe pressure fluctuation, high power consumption and frequent pump startup-stop. After adopting FC-051 constant pressure frequency conversion control system with pressure sensor feedback, it realizes sleep & wake-up automatic operation, cutting daily power consumption greatly, stabilizing water supply pressure and prolonging pump service life obviously.

Cas 2: Central Air-conditioner Fan System in Shopping Malls

Replace fixed-speed fan operation with variable frequency temperature closed-loop control, set minimum frequency to avoid fan surging, realize intelligent speed regulation according to indoor temperature, save massive electricity cost annually and lower operating noise effectively.

Cas 3: Food Packaging Production Line Multi-machine Linkage

Adopt multi-speed regulation and synchronous follow-up control to match operating speed of different conveying equipment. Built-in brake chopper achieves rapid stop, reduces material stacking and product damage rate, and improves overall production efficiency. Coated PCB adapts to humid and dusty food workshop environment.

Cas 4: Spinning Machine Control System in Textile Mill

Replace traditional slip speed regulating motor with VVC+ vector control inverter, realize high torque output at low speed, broaden speed regulation range, promote motor operating efficiency, reduce yarn breakage rate and cut daily maintenance frequency.

Cas 5: Aeration System for Sewage Treatment Plant

Match dissolved oxygen sensor to build PID closed-loop control system, automatically adjust fan air volume to keep dissolved oxygen content in optimal range, stabilize sewage treatment effect, reduce invalid energy consumption and lower equipment abrasion.

  1. Application Scene Matching Table
Application SceneMatching LevelAvantages principauxRemarques
Alimentation en eau à pression constante / circulating pump★★★★★PI regulation + intelligent logic, prominent energy-saving effectEquipped with pressure sensor and brake resistor suggested
Central air conditioner / cooling tower fan★★★★★Temperature closed-loop control, low noise and energy savingSurge prevention setting required, derate at high altitude
Heavy conveyor / hoist★★★★☆Stable start-stop, strong overload resistanceConfirm actual load type in advance
Nourriture & beverage production line★★★★☆Multi-speed control, high synchronization precisionCoated PCB for humid environment adaptation
Textile printing & dyeing machinery★★★★☆Low-speed high torque, wide speed rangeAdd anti-interference measures
Sewage treatment aeration system★★★★☆Precise PID control, energy consumption optimizationRegular radiator cleaning required
Heavy impact load equipment★☆☆☆☆Choose FC-302 series instead
Explosion-proof working environment★☆☆☆☆Special explosion-proof inverters required
Altitude over 2000m★☆☆☆☆Not recommended due to large power derating amplitude
  1. Key Selection Points for Practical Application
  2. Match inverter current reasonably according to actual motor load
  3. Select models with built-in brake units for frequent start-stop and fast stop working conditions
  4. Choose U/f control mode for fan & pump loads, VVC+ vector control for transmission and processing equipment
  5. Prioritize coated PCB models for humid, dusty and corrosive sites
  6. Select matched external accessories and control panels according to on-site debugging and remote control demands

Précédent:

Laisser une réponse

Laisser un message