E82EV552K4C is a 5.5kW three-phase inverter of Lenze 8200 Vector series. It accepts 380-480VAC input, delivers 13A output with IP20 protection grade. Built-in vector control and brake transistor, suitable for general industrial speed regulation applications.
- Définition du code modèle
| Segment de code | Description |
| E82 | Platform identifier for Lenze 8200 series inverters |
| EV | Contrôle vectoriel, supports precise torque and speed regulation |
| 55 | Power rating code: 5.5kW (7.5HP) |
| 2 | Frame size code: Taille 2 logement (100×240×140mm) |
| K | Integrated EMC filter, conforme à la norme EN 61800-3 |
| 4 | Input voltage class: 3-phase 400-500VAC (compatible with 380-480VAC) |
| C | Standard control interface with RS232/485 communication port |
Numéro de commande: E82EV552K4C (Modèle standard); E82EV552K4C200 (Extended Version)
- Principales spécifications techniques
| Catégorie | Caractéristiques | Remarques |
| Paramètres de base | ||
| Puissance nominale | 5.5kW (7.5HP) | Matches standard asynchronous motors |
| Tension d'entrée | 3-phase 380-480VAC, 50/60Hz | Conception à large tension |
| Tension de sortie | 3-phase 0-480VAC, same frequency as input | Vector controlled output |
| Courant de sortie | 13Une note, 150% surcharge pendant 60s | Strong overload capability |
| Gamme de fréquences | 0-599Hz | Applicable to high-speed motors |
| Performances de contrôle | ||
| Mode de contrôle | Contrôle vectoriel (Closed-loop V/F) | High low-speed torque, ±0.5% precision |
| Speed Ratio | 0.111111111 | Stable wide-range speed adjustment |
| Torque Response | Less than 100ms | Fast dynamic response |
| Braking Mode | Built-in brake transistor (≤11kW) | Compatible with 75Ω/500W brake resistor |
| Physical Properties | ||
| Classe de protection | IP20 | Indoor cabinet mounting only |
| Température ambiante | -10℃ ~ +55℃ (derate above 40℃) | Stockage: -25℃ ~ +70℃ |
| Humidité relative | 5%-95% sans condensation | Keep away from humid environment |
| Dimensions (L×H×P) | 100×240×140mm | Standard size 2 logement |
| Poids | Environ. 3.5kilos | Lightweight structure |
| Communication & Fonctions | ||
| Interface standard | RS232/485 (Modbus RTU) | Remote parameter configuration supported |
| Optional Modules | PROFIBUS, AppareilNet, etc.. | Compatible with industrial networks |
| Built-in Functions | Régulateur PID, 4 parameter sets, energy saving mode | Multi-scenario adaption |
- Full E82EV Series Model List
3-phase 400V Series (Suffix K4C)
| Modèle | Pouvoir | Courant de sortie | Size Code | Remarques |
| E82EV222K4C | 2.2kW | 5.5UN | 2 | Modèle de base |
| E82EV302K4C | 3.0kW | 7.5UN | 2 | |
| E82EV402K4C | 4.0kW | 10UN | 2 | |
| E82EV552K4C | 5.5kW | 13UN | 2 | Modèle actuel |
| E82EV752K4C | 7.5kW | 18UN | 2 | |
| E82EV113K4C | 11kW | 25UN | 3 | Enlarged housing |
| E82EV153K4C | 15kW | 32UN | 3 |
3-phase 230V Series (Suffix K2C)
| Modèle | Pouvoir | Courant de sortie | Size Code |
| E82EV251K2C | 0.25kW | 1.5UN | 1 |
| E82EV371K2C | 0.37kW | 2.0UN | 1 |
| E82EV551K2C | 0.55kW | 2.8UN | 1 |
| E82EV751K2C | 0.75kW | 3.8UN | 1 |
| E82EV112K2C | 1.1kW | 5.5UN | 2 |
| E82EV152K2C | 1.5kW | 7.5UN | 2 |
| E82EV222K2C | 2.2kW | 11UN | 2 |
Modèles étendus (Suffixe 200)
All standard models support 200 suffixe, par exemple. E82EV552K4C200
Enhanced C1-class EMC filter
Extended working temperature: -10℃ ~ +60℃
24-month warranty period
- Cross-brand Replacement Comparison
| Lenze Model | Siemens | Schneider | ABB | Omron | Replacement Tips |
| E82EV552K4C | MM440-5.5kW | ATV312HU55N4 | ACS550-01-012A-4 | 3G3RX-A4055 | Functions matched, note communication protocol difference |
| Principales différences | Rich parameter options | Rentable | Superior overload resistance | Compact dimension | Reset parameters when keeping original motor |
- Défauts courants & Solutions
| Code d'erreur | Type de défaut | Causes possibles | Solutions |
| F02 | Surtension | Excessive input voltage, rapid deceleration | 1. Check grid voltage |
| 2. Extend deceleration time | |||
| 3. Install brake resistor | |||
| F05 | Sous-tension | Low input voltage, power fluctuation | 1. Stabiliser l'alimentation |
| 2. Inspect wiring | |||
| 3. Equip voltage stabilizer | |||
| F08 | Surchauffer | Mauvaise dissipation de la chaleur, température ambiante élevée | 1. Clean cooling fan |
| 2. Améliorer la ventilation | |||
| 3. Operate under derated load | |||
| F13 | Surintensité | Motor short circuit, charge excessive | 1. Check motor winding |
| 2. Réduire la charge | |||
| 3. Adjust current limit parameters | |||
| Aucun affichage | Power failure | Phase loss, internal power damage | 1. Verify 3-phase input |
| 2. Test DC bus voltage | |||
| 3. Remplacer le module d'alimentation |
- Conformité des expéditions aériennes & Certifications
Air Transport Assessment
Lithium Battery: Built-in electrolytic capacitor, no lithium battery, UN38.3 test exempted
Classification: Ordinary electrical equipment, non-dangerous goods
Conditionnement: Anti-static package, fixed firmly against collision
Documents: Commercial invoice, packing list, CE certificate
Liste des certifications
| Certificate | Standard | Champ d'application |
| CE | DANS 61800-5-1(Sécurité), DANS 61800-3(CEM) | EU market access |
| UL | UL 508C | North America |
| ASC | C22.2 n°14 | Canada |
| CCC | GB/T 12668.3 | Chine |
| RoHS | 2011/65/UE | Environmental protection compliance |
Shipment Instructions
- Disconnect all external connections before delivery
- Fix inside rigid container with cushion materials
- Avoid inversion and violent vibration
- Attach copies of certification documents
- Application Cases & Industry Adaptation
Applications typiques
Material Conveying: Speed control for belt and chain conveyors, sur 30% économie d'énergie
Ventilateur & Water Pump: Constant pressure/flow PID control for central air conditioning and cooling towers
Machines-outils: Spindle drive, stepless speed regulation and fast start-stop
Machines d'emballage: Food and printing equipment, precise synchronous operation
Agitator Equipment: Chemical reactor stirring for variable viscosity materials
Industry Adaptation
| Industrie | Suitability | Avantages | Remarques |
| Automobile Manufacturing | ★★★★★ | Haute fiabilité, quick response | Reinforce EMC protection against interference |
| Nourriture & Beverage | ★★★★☆ | Suitable protection grade, entretien facile | Keep away from damp and corrosive atmosphere |
| Logistique & Entreposage | ★★★★★ | Excellent energy saving, entretien facile | Adapt to frequent start-stop operation |
| Chemical Industry | ★★★☆☆ | Good temperature resistance, strong overload capacity | Optional explosion-proof accessory required |
| Machines de construction | ★★★☆☆ | Vibration resistance, harsh environment adaptability | Additional reinforcement installation |
Practical Case
An auto parts factory adopts E82EV552K4C for stamping line conveyor:
Speed control accuracy improved to ±0.1m/min
Consommation d’énergie réduite de 28%, annual power saving about 120,000 RMB
Equipment failure rate decreased by 40%, maintenance cost cut by 35%
- Lignes directrices de sélection
Règles rapides
- Power Code: 55=5,5 kW, 75=7,5 kW, 11=11kW
- Voltage Identification: K4=400V, K2=230V
- Size Identification: 2=100mm width, 3=140mm width
- Fonction principale: EV=Vector control, K=EMC filter, C=Standard control
- Application Environment Requirements
Suitable Conditions
Installed inside industrial automation control cabinets
Température ambiante: -10℃ ~ +40℃, sec, dust-free and non-corrosive air
Stable power grid with voltage fluctuation ≤±10%
Scenarios requiring precise speed and torque adjustment
Unsuitable Conditions
Outdoor or humid locations (insufficient IP20 protection)
Heavy dust and corrosive gas environment
Severe grid fluctuation over ±15% without stabilizer
Heavy load frequent forward/reverse operation without brake resistor
Installation Precautions for Lenze E82EV552K4C
- Cabinet Installation Space
- Vertical wall mounting only; horizontal, side or upside-down installation forbidden
- Reserve ≥100mm vertical clearance, ≥30mm lateral clearance for heat dissipation
- Minimum 50mm spacing between multiple inverters to avoid heat interference
- Keep away from heat sources, air outlets and direct sunlight
- Environmental Limits
Température de fonctionnement: -10℃ ~ +55℃, derate load above 40℃
No condensation, poussière, corrosive or flammable gas
Keep distance from high-power electromagnetic devices, contactors and motors
Derate operation when altitude exceeds 1000m
- Spécifications de câblage
Câblage du circuit principal
- Do not reverse incoming L1/L2/L3 and outgoing U/V/W terminals
- Separate power cables and control cables with ≥20cm gap, no same conduit laying
- Reliable earthing, résistance de mise à la terre ≤4Ω, ground wire diameter no less than half of phase wire
- Fasten terminals with proper torque to prevent loose connection and overheating
Câblage du circuit de commande
- Use shielded twisted pair for analog and communication cables, single-end shielding grounding
- Avoid routing signal cables close to power lines
- Prevent polarity reversal of external 24V power supply
- Dissipation thermique & Ventilation
- Keep cabinet door ventilated, clean filter screen regularly
- Equip cooling fan for smooth air circulation
- Avoid direct sunlight on the device
- CEM & Anti-interference Protection
- Built-in EMC filter works only with complete grounding
- Motor cable length recommended ≤50m; install output reactor for long cables
- Do not coil or twist input and output wires
- Freewheel diodes parallel connected to peripheral relays and solenoid valves
- Brake Accessory Installation
Built-in brake transistor matched with external brake resistor
- Use 75Ω/500W resistor, mount in well-ventilated area
- Short resistor wiring, firm connection and thermal isolation protection
- Pre-power Inspection
- Confirm 3-phase 380-480V input without phase loss
- Check no inter-phase or earth short circuit, correct and tight wiring
- Pass motor insulation test; perform no-load trial run first
- Mechanical Fixation
- Tighten four mounting screws evenly to avoid shake
- Flat mounting surface to prevent housing deformation
- Règlements de sécurité
- Attendez 5 minutes after power off for DC bus discharge before disassembly
- Do not open cover or touch terminals during operation
- Forbid short-circuit protection terminals or disable fault protection functions
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires



















NH42-63-318x560.png)