Siemens 6SE6440-2UC15-5AA1 Frequency Inverter - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 Siemens 6SE6440-2UC15-5AA1 Frequency Inverter - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

onduleur solaire/électrique/

Siemens 6SE6440-2UC15-5AA1 Frequency Inverter

✅ Model Code Explanation Segment Definition 6SE6440 MM440 universal inverter series 2 Built-in Basic Operator Panel (BOP), no AOP U 200~240V single-phase / three-phase universal input (1AC/3AC) C No integrated EMC filter 15 0.55kW power rating 5AA1 Standard version, filterless, frame size A 📋 Key Technical Specifications Rated Power: 0.55 kW (Couple constant) Tension d'entrée: ...

  • Détails du produit

✅ Model Code Explanation

SegmentDéfinition
6SE6440MM440 universal inverter série
2Built-in Basic Operator Panel (BOP), no AOP
U200~240V single-phase / three-phase universal input (1AC/3AC)
CNo integrated EMC filter
150.55Puissance nominale en kW
5AA1Version standard, filterless, frame size A

📋 Key Technical Specifications

Puissance nominale: 0.55 kW (Couple constant)

Tension d'entrée: AC 200–240V ±10%, 47–63Hz, compatible with single-phase or three-phase input

Courant de sortie nominal: 3.0 UN

Capacité de surcharge: 150% pour les années 60; 200% pendant 3s

Classe de protection: IP20

Dimensions hors tout(H×L×P): 173 × 73 × 149 mm (Frame Size A)

Poids net: environ. 1.3 kilos

Température ambiante: -10 ~ +50℃ (no power derating)

Modes de contrôle: Contrôle V/F, contrôle vectoriel, PID intégré, Modbus RTU pris en charge

Équipement standard: BOP panel; no integrated EMC filter

📌 Product Lifecycle

MM440 discontinued in 2019, available only as spare parts. No mass-production new units. Stock new units or used refurbished units circulate in the market.

🔄 Replacement Selection

  1. Direct replacement series: G120 Inverter

Recommandé: 6SL3210-1PB13-0UL0 (0.55kW 220V, without filter), BOP-2 panel to be ordered separately.

  1. Retrofit Note: Terminal definitions and parameter systems differ between MM440 and G120. Control logic and parameters require full re-commissioning.

🛠 Typical Applications

Bandes transporteuses, petits ventilateurs & pompes à eau, mélangeurs, petit matériel de transport, machines d'emballage. Suitable for speed regulation of 0.55kW, 220V AC asynchronous motors.

📎 Optional Accessories

BOP: 6SE6400-0BP00-0AA1 (factory fitted)

AOP Advanced Operator Panel: 6SE6400-0AP00-0AA1

Filtre CEM: 6SE6400-2FA00-6AD0

Résistance de freinage: Optional as required (usually unnecessary for 0.55kW low power)

⚠️ Troubleshooting Summary (General for MM440)

  1. F0001 Overcurrent: Court-circuit moteur, câble endommagé, défaut à la terre, panne du module d'alimentation
  2. F0002 Overvoltage: Rapid deceleration, grid surge; braking resistor may be required
  3. F0003 Undervoltage: Phase d'entrée manquante, voltage drop
  4. F0011 Overtemperature: Blocked cooling channel, température ambiante excessive, fan damage

Code SH

85044084 (Static converters, frequency inverters)

Siemens 6SE6440-2UC15-5AA1 (MM440, 220V 0.55kW) Scénarios d'application

Fonctionnalités principales: Single/three-phase 220V power supply, contrôle vectoriel, PID intégré, Modbus RTU, stable speed regulation at low torque. Power limited to 0.55kW, only compatible with small-load motors, widely used for stand-alone small automation equipment retrofit and spare part replacement for legacy machines.

  1. Transport de matériaux (Le plus courant)
  2. Petits convoyeurs à bande, convoyeurs à rouleaux: Short packaging line conveyors, laboratory transport tables, small sorting branch lines. Démarrage progressif & soft stop prevent material slipping or tipping; multi-speed function available.
  3. Small hoists / miniature winches: Light-duty lifting mechanisms. MM440 vector control delivers stable low-speed torque for light-load lifting within 0.55kW power limit.
  4. Fluid Equipment (Ventilateurs & Pompes, PID for constant pressure/flow)
  5. Petits ventilateurs centrifuges, duct exhaust fans: Workshop local exhaust, oven circulation fans; energy saving via variable speed drive.
  6. Mini water pumps, pompes doseuses: Alimentation en eau à pression constante, chemical dosing pumps. Built-in PID performs closed-loop constant pressure/flow control with 4-20mA analog feedback.

Advantage for low-flow cases: 220V single-phase power input, preferred where 380V three-phase power is unavailable on site.

III. Conditionnement & Light Industrial Machinery

  1. Petites machines d'emballage: Film feeding for pillow packaging, label feed motors, screw bottle separation drive. Smooth start-stop and PLC-linked speed control.
  2. Food light industry equipment: Small mixing tanks, mélangeurs, extrusion actuators (0.55kW small mixing motors), auxiliary drives for food production lines.
  3. Textile auxiliary machines: Small rewind/unwind units for simple tension control.
  4. Machines-outils & Automation Auxiliary Equipment
  5. Machine tool auxiliary drives: Coolant pumps, small lubrication pumps, auxiliary table feed motors.
  6. Tables rotatives, indexing turntables: Stable low-speed rotation for point positioning.
  7. Automation training benches / teaching equipment: Classic MM440 teaching unit for colleges, used to learn vector control, Modbus communication and multi-speed programming.
  8. CVC, Bâtiment & Other Auxiliary Systems
  9. Small air damper actuators, unités d'air frais
  10. Gate valves, small roller shutter drives: Speed control for workshop small doors and automatic roller shutters
  11. Spare part replacement for legacy equipment: Retrofit for original equipment fitted with this MM440 model. The series is discontinued, so it is mostly used for maintenance replacement.

✅ Selection Prerequisites & Limites

Alimentation: Site available power is AC220V (single-phase input can drive three-phase motors)

Moteur: Rated motor power ≤0.55kW three-phase asynchronous motor

Points forts: Good low-speed torque with vector control, equipped with BOP panel, PID intégré, relay/analog I/O, Communication Modbus; more capable than basic simple inverters

❌ Not suitable: Heavy shock loads, high-power machinery, main hoisting winches, continuous high-overload operating conditions

Supporting Control Schemes

Local speed setting via panel: Manual frequency adjustment through BOP

Multi-speed via terminals: DI digital terminals for preset speed levels

Analog closed-loop: AI connected to pressure/flow sensors, PID automatic constant pressure/flow regulation

Communication automate: Modbus RTU for PLC to read/write frequency, running status and fault codes

Siemens 6SE6440-2UC15-5AA1 (MM440 0.55kW 220V, No Built-in EMC Filter) Replacement Models Summary

Original unit features: AC200~240V single/three-phase input, contrôle vectoriel, PID, Modbus RTU, 4DI/2AI/2AO, 2 sorties relais; abandonné, no new original production.

Selection Priority: Siemens official successor models → Siemens economy models → Domestic vector inverters

  1. Siemens Officially Recommended Replacements (Premier choix, Closest function to MM440)
  2. SINAMIQUE G120 (Modulaire, function matches MM440, for complex original control: PID, multi-vitesse, Modbus)

Module d'alimentation: 6SL3210-1PB13-0UL0 (200-240V, 0.55kW, no integrated filter, output current 3A consistent with original unit)

Matching Control Unit: CU240E-2 (6SL3244-0BB12-1BA1), optional BOP-2 panel (6SL3255-0AA00-4CA1)

✅ Avantages: Sensorless vector support, PID intégré, Modbus RTU, I/O count close to MM440; expandable communication

⚠️ Remarque: Terminal definitions and parameter codes are fully incompatible; parameters cannot be copied directly. Re-commissioning required, cutout dimensions differ.

  1. G120C Compact Integrated Type (All-in-one, simple installation, gain de place, preferred for fans/conveyors/pumps)

Numéro de commande: 6SL3210-1KE11-8UB2 (220V 0.55kW, no filter, integrated built-in control unit, BOP interface available)

✅ All-in-one design, separate power module + CU not required. Ideal for cabinet retrofit with limited space; STO safety function integrated

⚠️ I/O count slightly less than original MM440; evaluate carefully for complex logic

  1. SINAMICS V20 (Economy type, simple speed regulation with budget constraints)

Numéro de commande: 6SL3210-5BB11-2UV1 (220V, 0.55kW, no integrated filter)

✅ Lower cost, supports V/F / basic vector, Modbus, multi-vitesse; suitable for fans, pumps and simple conveyors without high-precision low-speed torque requirement

❌ Limites: Vector performance weaker than MM440/G120, not for low-speed heavy-load applications, fewer I/O points

  1. Same-series Spare Part Option (Non recommandé pour les nouveaux projets, emergency maintenance only)

Stock MM440 original unit: 6SE6440-2UC15-5AA1 stock new / second-hand refurbished

Risques: Limited supply, high price, no warranty, ageing risk for used units. Only for short-term equipment transition, pas pour les nouveaux projets.

III. Domestic Replacements (Cost-down retrofit, contrôle vectoriel, 220V single-phase input driving three-phase motors)

Applicable for retrofit projects where wiring and PLC program modification are permitted, pursuing cost advantages

  1. Inovance MD600 / MD380 220V 0.55kW: Contrôle vectoriel, Modbus, PID, abundant I/O
  2. INVT GD20: General vector inverter, widely used for packaging & conveying machinery
  3. Delta VFD-EL / VFD-M: Low-power 220V single-phase input, basic speed regulation scenarios

📌 Selection Comparison Table

ModèleNuméro de commande.TensionPouvoirVector PerformanceApplication
MM440 (Original)6SE6440-2UC15-5AA1220V0.55kWHigh-performance vectorConvoyage, mélange, constant pressure pump, multi-vitesse & PID closed-loop
Modular G1206SL3210-1PB13-0UL0+CU240E-2220V0.55kWHigh-performance vectorPrimary functional replacement, preferred for legacy PID & communication projects
Integrated G120C6SL3210-1KE11-8UB2220V0.55kWStandard vectorArmoire compacte, les fans, convoyeurs à bande, STO safety required
Economy V206SL3210-5BB11-2UV1220V0.55kWBasic vectorSimple speed control, les fans & pompes, budget-sensitive

⚠️ Critical Retrofit Notes

  1. Compatibilité de l'alimentation: The original unit accepts single-phase 220V input for three-phase motor drive. G120C/G120/V20 models of the same specification also support this mode.
  2. Dimensions de découpe: Frame A cutout for MM440 differs from G120/V20. Cabinet cutout modification is usually required.
  3. Parameter Incompatibility: MM440 P-parameter system is independent from G120/V20; parameter upload/download cannot be performed directly.
  4. CEM: Original unit has no integrated filter. Select filterless variant for replacement. Install external EMC filter if noise immunity is needed.
  5. Freinage: Evaluate braking resistor sizing if the machine requires rapid stopping.

✅ Quick Selection Guidance

Original machine uses low-speed vector, PID constant pressure, Communication Modbus, multi-speed → Select G120 (modular CU240E-2)

Simple fan/conveyor application, all-in-one unit preferred for compact cabinet → G120C

Basic speed regulation only, no complex closed loop, budget priority → V20

Cost reduction project, domestic commissioning acceptable → Inovance / INVT and other domestic vector inverters

Précédent:

Suivant:

Laisser une réponse