DELIXI CJX2-25 AC Contactor

DELIXI CJX2-25 is a general-purpose AC contactor with a rated current of 25A. It complies with IEC 60947-4-1 and GB/T14048.4 standards. It is mainly used for remote making and breaking of circuits, as well as frequent starting and control of AC motors. Model Code Explanation Code Meaning CJ AC Contactor X2 Design sequence number 25 ...

  • Détails du produit

DELIXI CJX2-25 is a general-purpose AC contactor with a rated current of 25A. It complies with IEC 60947-4-1 and GB/T14048.4 standards. It is mainly used for remote making and breaking of circuits, as well as frequent starting and control of AC motors.

  1. Model Code Explanation
CodeSignification
CJContacteur CA
X2Design sequence number
25Rated current of main poles: 25UN
Suffixe (par exemple. 10/01/11)Configuration des contacts auxiliaires:
10 = 1 NON, 0 Caroline du Nord
01 = 0 NON, 1 Caroline du Nord
11 = 1 NON, 1 Caroline du Nord
Coil voltage codeM = AC220V, Q = AC380V
Other options: AC24V, 36V, 48V, 110V, 127V

Complete model example: CJX2-2510M (25UN, 1 NON + 0 Caroline du Nord, Bobine AC220V)

  1. Paramètres techniques clés
ArticleValeurRemarques
Rated operational current25UN (AC‑3, 380V)Corresponding motor power: 7.5kW (380V)
Tension d'isolement nominale690VMaximum operating voltage
Rated operational voltageUp to 690V50/60Hz universal
Main contact configuration3NON (3 Normalement ouvert)Configuration standard
Contacts auxiliaires1NON / 1Caroline du Nord / 1NON+1NCOptional configurations
Tension de bobineAC24V ~ 380VMultiple specifications available
Endurance mécanique≥ 10 millions d'opérationsOperating frequency ≤ 1200 opérations/heure
Endurance électrique≥ 1 millions d'opérationsUtilization category AC‑3
Méthode de montageScrew mounting / Rail mountingCompatible with standard 35mm DIN rail
Degree of protectionIP20Empêche le contact des doigts avec les pièces sous tension

III. Environnement opérationnel

  1. Température ambiante: -5℃ ~ +40℃, average temperature over 24 hours ≤ +35℃
  2. Altitude: ≤ 2000m; derating required above this altitude
  3. Relative humidity: ≤ 90% (at +25℃), pas de condensation
  4. Mounting condition: Vertical mounting (inclinaison ≤ 5°), no significant vibration or shock
  5. Degré de pollution: 3, adapté aux environnements industriels
  6. Cross-Reference / Modèles de remplacement (Other Brands)
MarqueModèle de remplacementCompatibilité
SchneiderLC1D25Compatible dimensions and mounting holes, direct replacement
Siemens3RT2026Functionally equivalent, identical electrical parameters
CHINTNXC‑25 (formerly CJX2‑25)Same platform, fully interchangeable
ABBA16‑30‑01 (note rated current difference)25A equivalent: A26‑30‑01
  1. Official Order Codes & Liste complète des modèles

Complete models of DELIXI CJX2-25 series (based on official data):

Main ModelContacts auxiliairesTension de bobineOrder Code Example
CJX2‑2510 (1NON)AC220VCJX22510M
CJX2‑2510 (1NON)AC380VCJX22510Q
CJX2‑2501 (1Caroline du Nord)AC220VCJX22501M
CJX2‑2501 (1Caroline du Nord)AC380VCJX22501Q
CJX2‑2511 (1NON+1NC)AC220VCJX22511M
CJX2‑2511 (1NON+1NC)AC380VCJX22511Q
CJX2‑2504 (4NON)AC220VCJX22504M
  1. Engineering Application Recommendations
  2. Lignes directrices de sélection

Select the appropriate model based on load type (résistif/inductif), courant nominal, control voltage, and operating frequency.

  1. Notes d'installation

Inspect product appearance before installation to ensure no damage

Tighten terminal screws securely to avoid overheating from loose connections

When used with thermal relays, maintain a gap ≥ 5mm for heat dissipation

  1. Maintenance Suggestions

Regularly check contact wear; replace contacts if wear exceeds 1mm

Clean the coil core surface to remove dust and oil for reliable attraction

Inspect and retighten loose wiring terminals

VII. Key Tips

  1. CJX2-25 is a standard contactor for general industrial control. For high-frequency operation (>600 opérations/heure), the CJX2S series (Pioneer series) is recommended.
  2. Coil voltage must match the control circuit voltage to prevent coil burnout.
  3. When replacing contactors of other brands, verify mounting dimensions and wiring methods to ensure compatibility.

DELIXI Contactors-Full Series Model List (Official 2026 Edition)

DELIXI contactors are classified into General AC Contactors, DC Contactors, and Special-Purpose Contactors by technical platform and application scenario. They cover a full current range from 0.9A to 1000A, meeting demands in industry, construction, new energy, et d'autres domaines.

  1. General AC Contactors (Mainstream Series)
  2. CJX2s Series (Pioneer Series, Ideal for High-Frequency Operation)

Positioning: Upgraded version of classic CJX2, suitable for high-frequency start/stop equipment such as fans and pumps

Paramètres clés: Rated current 6A~95A, AC-3 380V, rated insulation voltage 690V, operating frequency ≤ 1800 opérations/heure

Complete model list:

Main ModelAuxiliary Contact Config.Code de tension de bobineOrder Code Example
CJX2s‑0610/01/11/22M.(AC220V)/Q(AC380V)/

UN(AC110V)/D(DC24V)

CJX2s0610M
CJX2s‑0910/01/11/22M/Q/A/DCJX2s0901Q
CJX2s‑1210/01/11/22M/Q/A/DCJX2s1211M
CJX2s‑1810/01/11/22M/Q/A/DCJX2s1822Q
CJX2s‑2510/01/11/22M/Q/A/DCJX2s2510M
CJX2s‑3210/01/11/22M/Q/A/DCJX2s3201Q
CJX2s‑3810/01/11/22M/Q/A/DCJX2s3811M
CJX2s‑4010/01/11/22M/Q/A/DCJX2s4022Q
CJX2s‑5010/01/11/22M/Q/A/DCJX2s5010M
CJX2s‑6510/01/11/22M/Q/A/DCJX2s6501Q
CJX2s‑8010/01/11/22M/Q/A/DCJX2s8011M
CJX2s‑9510/01/11/22M/Q/A/DCJX2s9522Q

Caractéristiques: Upgraded silver contact technology, 70%–120% wide voltage pull-in, mechanical endurance ≥ 10 millions d'opérations, electrical endurance ≥ 1 millions d'opérations

  1. Série CJX2 (Classic General-Purpose Type)

Positioning: Traditional general contactor, choix rentable

Paramètres clés: Rated current 9A~95A, AC-3 380V, rated insulation voltage 690V, operating frequency ≤ 1200 opérations/heure

Complete model list:

Main ModelAuxiliary Contact Config.Code de tension de bobineOrder Code Example
CJX2‑0910/01/11M/Q/A/DCJX20910M
CJX2‑1210/01/11M/Q/A/DCJX21201Q
CJX2‑1810/01/11M/Q/A/DCJX21811M
CJX2‑2510/01/11M/Q/A/DCJX22510M
CJX2‑3210/01/11M/Q/A/DCJX23201Q
CJX2‑4010/01/11M/Q/A/DCJX24011M
CJX2‑5010/01/11M/Q/A/DCJX25010M
CJX2‑6510/01/11M/Q/A/DCJX26501Q
CJX2‑8010/01/11M/Q/A/DCJX28011M
CJX2‑9510/01/11M/Q/A/DCJX29510M
  1. CJX1 Series (Traditional High-Power Type)

Positioning: Economical high-power motor control, replaces part of CJ20 series

Paramètres clés: Rated current 9A~475A, AC-3 380V, rated insulation voltage 690V

Complete model list:

Main ModelAuxiliary Contact Config.Tension de bobineOrder Code Example
CJX1‑922 (2NON+2NC)AC220V/380VCJX1922M
CJX1‑1222AC220V/380VCJX11222Q
CJX1‑1622AC220V/380VCJX11622M
CJX1‑2222AC220V/380VCJX12222Q
CJX1‑3222AC220V/380VCJX13222M
CJX1‑4522AC220V/380VCJX14522Q
CJX1‑7522AC220V/380VCJX17522M
CJX1‑8522AC220V/380VCJX18522Q
CJX1‑10022AC220V/380VCJX110022M
CJX1‑14022AC220V/380VCJX114022Q
CJX1‑17022AC220V/380VCJX117022M
CJX1‑20522AC220V/380VCJX120522Q
CJX1‑25022AC220V/380VCJX125022M
CJX1‑30022AC220V/380VCJX130022Q
CJX1‑40022AC220V/380VCJX140022M
CJX1‑47522AC220V/380VCJX147522Q
  1. CJ20 Series (Traditional Classic High-Power)

Positioning: Heavy-duty motor control, suitable for heavy-load scenarios such as metallurgy and mining

Paramètres clés: Rated current 10A~630A, AC-3 380V, rated insulation voltage 1140V

Complete model list:

Main ModelAuxiliary Contact Config.Tension de bobinePuissance moteur applicable (380V)
CJ20‑1022AC220V/380V5.5kW
CJ20‑1622AC220V/380V7.5kW
CJ20‑2522AC220V/380V11kW
CJ20‑4022AC220V/380V18.5kW
CJ20‑6322AC220V/380V30kW
CJ20‑10022AC220V/380V55kW
CJ20‑16022AC220V/380V90kW
CJ20‑25022AC220V/380V132kW
CJ20‑40022AC220V/380V200kW
CJ20‑63022AC220V/380V315kW
  1. CJ40 Series (New-Generation High-Power Contactors)

Positioning: Replaces CJ20, preferred for industrial power distribution, energy-saving and efficient

Paramètres clés: Rated current 63A~630A, AC-3 380V, rated insulation voltage 1140V, power consumption reduced by 30%

Complete model list:

Main ModelAuxiliary Contact Config.Tension de bobinePuissance moteur applicable (380V)
CJ40‑6322AC220V/380V30kW
CJ40‑10022AC220V/380V55kW
CJ40‑16022AC220V/380V90kW
CJ40‑25022AC220V/380V132kW
CJ40‑40022AC220V/380V200kW
CJ40‑50022AC220V/380V250kW
CJ40‑63022AC220V/380V315kW
  1. CDC6 Series (For Automation, High Cost-Performance)

Positioning: Dedicated for automated production lines and test equipment, matches CDR6 thermal relays

Paramètres clés: Rated current 9A~630A, AC-3 380V, rated insulation voltage 690V

Complete model list:

Main ModelAuxiliary Contact Config.Tension de bobineOrder Code Example
CDC6‑0911AC220V/380VCDC60911M
CDC6‑1211AC220V/380VCDC61211Q
CDC6‑1811AC220V/380VCDC61811M
CDC6‑2511AC220V/380VCDC62511Q
CDC6‑3211AC220V/380VCDC63211M
CDC6‑4011AC220V/380VCDC64011Q
CDC6‑5011AC220V/380VCDC65011M
CDC6‑6511AC220V/380VCDC66511Q
CDC6‑8011AC220V/380VCDC68011M
CDC6‑9511AC220V/380VCDC69511Q
CDC6‑11522AC220V/380VCDC611522M
CDC6‑15022AC220V/380VCDC615022Q
CDC6‑18522AC220V/380VCDC618522M
CDC6‑22522AC220V/380VCDC622522Q
CDC6‑26522AC220V/380VCDC626522M
CDC6‑33022AC220V/380VCDC633022Q
CDC6‑40022AC220V/380VCDC640022M
CDC6‑50022AC220V/380VCDC650022Q
CDC6‑63022AC220V/380VCDC663022M
  1. CDC6i Series (Nouveau 6 Série, Intelligent Control)

Positioning: For automated production and testing equipment, compatible with intelligent control modules

Paramètres clés: Rated current 9A~95A, AC-3 380V, Protection IP20, compatible with smart modules

Complete model list:

Main ModelAuxiliary Contact Config.Tension de bobineOrder Code Example
CDC6i‑0910/01/11AC220V/380VCDC6i0910M
CDC6i‑1210/01/11AC220V/380VCDC6i1201Q
CDC6i‑1810/01/11AC220V/380VCDC6i1811M
CDC6i‑2510/01/11AC220V/380VCDC6i2510M
CDC6i‑3210/01/11AC220V/380VCDC6i3201Q
CDC6i‑4010/01/11AC220V/380VCDC6i4011M
CDC6i‑5010/01/11AC220V/380VCDC6i5010M
CDC6i‑6510/01/11AC220V/380VCDC6i6501Q
CDC6i‑8010/01/11AC220V/380VCDC6i8011M
CDC6i‑9510/01/11AC220V/380VCDC6i9510M
  1. CDC10 Series (Traditional Economical Type)

Positioning: Building power distribution and general motor control, large market inventory

Paramètres clés: Rated current 10A~150A, AC-3 380V

Complete model list:

Main ModelAuxiliary Contact Config.Tension de bobineApplication
CDC10‑1022AC220V/380VPetits moteurs
CDC10‑2022AC220V/380VPetits moteurs
CDC10‑4022AC220V/380VMedium motors
CDC10‑6022AC220V/380VMedium motors
CDC10‑10022AC220V/380VLarge motors
CDC10‑15022AC220V/380VLarge motors
  1. CDC1 Series (Mini Contactors)

Positioning: Precision control and small equipment, replaces intermediate relays

Paramètres clés: Rated current 3A~12A, AC220V/380V

Complete model list:

Main ModelAuxiliary Contact Config.Tension de bobineApplication
CDC1‑310/0124V/110V/220VPrecision instruments
CDC1‑610/0124V/110V/220VSmall equipment
CDC1‑910/0124V/110V/220VPetits moteurs
CDC1‑1210/0124V/110V/220VPetits moteurs
  1. DC Contactor Series
  2. CZ0 Series (For Industrial DC Motor Control)

Positioning: Remote frequent making/breaking of DC circuits, control of DC motors

Paramètres clés: Rated current 10A~600A, rated voltage up to 440V DC

Complete model list:

Main ModelContact Config.Tension de bobineOrder Code Example
CZ0‑1010/01DC220V/440VCZ01010DC220V
CZ0‑2010/01DC220V/440VCZ02001DC440V
CZ0‑4010/01DC220V/440VCZ04010DC220V
CZ0‑10010/01DC220V/440VCZ010001DC440V
CZ0‑15010/01DC220V/440VCZ015010DC220V
CZ0‑20010/01DC220V/440VCZ020001DC440V
CZ0‑30010/01DC220V/440VCZ030010DC220V
CZ0‑40010/01DC220V/440VCZ040001DC440V
CZ0‑60010/01DC220V/440VCZ060010DC220V
  1. CDZJ Series (Solenoid-Type DC Contactors)

Positioning: Commencer, reverse, brake of DC motors; control of lifting electromagnets

Paramètres clés: Rated current 50A~400A, single/dual coil optional, intermittent duty

Complete model list:

Main ModelStructure TypeTension de bobineOrder Code Example
CDZJ‑50ANormalement ouvertDC12V/24V/48V/110V/220VCDZJ50ADDC24V
CDZJ‑50BNormalement ferméDC12V/24V/48V/110V/220VCDZJ50BDDC24V
CDZJ‑100ANormalement ouvertDC12V/24V/48V/110V/220VCDZJ100ADDC24V
CDZJ‑100BNormalement ferméDC12V/24V/48V/110V/220VCDZJ100BDDC24V
CDZJ‑200ANormalement ouvertDC12V/24V/48V/110V/220VCDZJ200ADDC24V
CDZJ‑200BNormalement ferméDC12V/24V/48V/110V/220VCDZJ200BDDC24V
CDZJ‑400ANormalement ouvertDC12V/24V/48V/110V/220VCDZJ400ADDC24V
CDZJ‑400BNormalement ferméDC12V/24V/48V/110V/220VCDZJ400BDDC24V
  1. CDEV6i Series (New Energy High-Voltage DC Contactors)

Positioning: EV charging piles, battery power distribution systems, solar power equipment

Paramètres clés: Rated voltage DC1000V, rated current 50A~400A, IP67 protection

Complete model list:

Main ModelContact Config.Tension de bobineApplication
CDEV6i‑5010DC12V/24VSmall charging piles
CDEV6i‑10010DC12V/24VMedium charging piles
CDEV6i‑20010DC12V/24VLarge charging piles
CDEV6i‑30010DC12V/24VEnergy storage systems
CDEV6i‑40010DC12V/24VElectric vehicle batteries

III. Special-Purpose Contactors

  1. CDZ7 Series (Contactor-Type Relays)

Positioning: Signal amplification and transmission in control circuits, replaces intermediate relays

Paramètres clés: Rated current 5A~10A, AC/DC universal control voltage

Complete model list: CDZ7-52P, CDZ7-101P, CDZ7-102P, CDZ7-104P

  1. CDC7 Series (Interlocked Contactors)

Positioning: Reversible control circuits, prevents reverse power connection

Paramètres clés: Rated current 9A~95A, AC-3 380V, reliable mechanical interlock

Complete model list: CDC7-09, CDC7-12, CDC7-18, CDC7-25, CDC7-32, CDC7-40, CDC7-50, CDC7-65, CDC7-80, CDC7-95

  1. CDCH8s Series (Household / Small Commercial Contactors)

Positioning: Light loads such as lighting and air conditioning, residential and small commercial buildings

Paramètres clés: Rated current 6A~63A, AC220V/400V, 2P/4P optional

Complete model list: CDCH8s-6, CDCH8s-10, CDCH8s-16, CDCH8s-20, CDCH8s-25, CDCH8s-32, CDCH8s-40, CDCH8s-50, CDCH8s-63

  1. Sélection & Replacement Guide
SérieBest ApplicationRemplacementRemarques
CJX2sHigh‑frequency start/stop (>600 opérations/heure)Replaces CJX2, Schneider LC1DWide voltage pull‑in, long endurance
CJX2General industrial controlReplaces CHINT NXC, ABB Série ACost‑effective, highly versatile
CJ40High‑power motors (>100kW)Replaces CJ20, Siemens 3RTEnergy‑saving, easy maintenance
CDC6Automated production linesReplaces Siemens 3RT, ABB Série ACompatible with smart modules
CZ0/CDZJCommande de moteur à courant continuReplaces Siemens 3RT DC typeSolenoid structure, pouvoir de coupure élevé
CDEV6iNew energy applicationsNo direct replacementIP67, high‑voltage DC
  1. Règles de dénomination des modèles

DELIXI contactor models follow these rules:

  1. Basic code: CJ = AC Contactor, CZ = DC Contactor, CDC = General Contactor
  2. Design number: X2 = 2nd generation, X1 = 1st generation, 40 = 40th generation
  3. Courant nominal: Directly marked in amps (UN), par ex., 25 = 25A
  4. Contacts auxiliaires: 10 = 1NO 0NC, 01 = 0NO 1NC, 11 = 1NO 1NC, 22 = 2NO 2NC
  5. Tension de bobine: M = AC220V, Q = AC380V, A = AC110V, D = DC24V; special voltages marked numerically

Translation Notes

All brand & model names (CJX2, CDC6, LC1D, 3RT etc.) kept unchanged as industry standard identifiers

Technical terms aligned with IEC / international electrical engineering usage

Format (headings, tables, structure) preserved exactly for engineering documentation use

Précédent:

Laisser une réponse

Laisser un message