LANBAO PR18S-BC10DNO - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

LANBAO PR18S-BC10DNO - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

électrique/

LANBAO PR18S-BC10DNO

PR18S-BC10DNO est un capteur photoélectrique à réflexion diffuse à boîtier en plastique cylindrique M18 de LANBAO (Détection Lanbao de Shanghai) Série PR18S. It adopts a dedicated control IC for stable performance and integrates multiple circuit protections. Rated IP67 for dust and water resistance, it is a general-purpose object detection component widely used in industrial automation. It comes standard with a ...

  • Détails du produit

PR18S-BC10DNO is an M18 cylindrical plastic housing diffuse-reflective photoelectric sensor from LANBAO (Détection Lanbao de Shanghai) Série PR18S. It adopts a dedicated control IC for stable performance and integrates multiple circuit protections. Rated IP67 for dust and water resistance, it is a general-purpose object detection component widely used in industrial automation. It comes standard with a 2-meter PVC cable (suffixe: -E2).

  1. Model Code Decoding

The full standard model is PR18S-BC10DNO-E2. The definition of each code is as follows:

PR18S: Série de produits, featuring M18×1 thread, PBT plastic housing and diffuse-reflective detection principle

BC10: Detection specification

BC: Réflexion diffuse (direct reflection) detection mode

10: Rated sensing distance of 10cm (fixé, non réglable)

D: Power supply type, DC 10~30VDC

N: Type de sortie, NPN

Ô: Output logic, Normalement ouvert (NON; output turns on when an object is detected)

-E2 (Default suffix): Cable outlet, standard 2m PVC cable; suffix -C stands for M12 4-pin connector type

  1. Principales spécifications techniques
CatégorieSpécification
Detection ModeDiffuse reflection (direct reflection)
Source de lumière880nm Infrared LED
Rated Sensing Distance10cm (basé sur 90% reflectivity white card, non réglable)
Tension d'alimentation10 ~ 30 VCC
Type de sortie3-wire NPN Normally Open (NON)
Courant de charge maximum≤300mA
Consommation actuelle≤25mA
Temps de réponse<8.2ms
Précision de répétition≤5% Sr
Hysteresis Range3% ~ 20% Sr
Fonctions de protectionProtection contre l'inversion de polarité, protection contre les courts-circuits, protection contre les surcharges, protection contre les surtensions
Status IndicatorLED jaune (lights up when object is detected)
Matériau du boîtierPBT Engineering Plastic
Dimension globaleM18×1 thread × 53.5mm (body length)
Classe de protectionIP67 (Compliant with IEC Standard)
Température de fonctionnement-15℃ ~ +55℃
Ambient Humidity35% ~ 95%RH (Sans condensation)
CertificationsCE, UL
  1. Full Model List of DC Diffuse-Reflective Sensors in the Same Series
Distance de détectionNPN NONNPN NCPNP NONPNP NCNPN NO+NCPNP NO+NC
10cm (Non réglable)PR18S-BC10DNOPR18S-BC10DNCPR18S-BC10DPOPR18S-BC10DPCPR18S-BC10DNRPR18S-BC10DPR
40cm (Réglable)PR18S-BC40DNOPR18S-BC40DNCPR18S-BC40DPOPR18S-BC40DPCPR18S-BC40DNRPR18S-BC40DPR

Note: All models are equipped with -E2 (2m de câble) par défaut; replace the suffix with -C for connector version.

  1. Définition du câblage (3-wire Cable Version)

Brown wire: Power positive (+10~30 V CC)

Blue wire: Puissance négative (0V / GND)

Black wire: Sortie de signal (NPN NON; output conducts when object is detected, connect to the negative side of load)

  1. Applications typiques

Workpiece presence detection and counting on automated production lines

Material detection for packaging and printing industries

Object recognition and sorting trigger on warehouse conveyor lines

Limit positioning and home position detection for equipment stations

Missing part and falling part detection for small components

  1. Matrice de dépannage pour les défauts courants
Phénomène de défautCause premièreSolutions étape par étape
Indicator off and no output after power-on1. Polarité d'alimentation inversée1. Check brown and blue wires and rewire correctly
2. Supply voltage out of 10~30VDC range2. Measure supply voltage with multimeter to ensure it is within rated range
3. Internal cable breakage3. Replace cable or conduct cross test with spare sensor
No signal output even when object is detected1. Object beyond effective sensing distance1. Reduce the distance between sensor and object with proper margin
2. Low reflectivity of measured object (pure black / light-absorbing material)2. Use high-reflective surface or select 40cm long-distance model
3. Wrong wiring of output circuit3. Verify complete connection of black output wire and load circuit
Faux déclenchement & continuous output with no object1. Highly reflective objects in background1. Adjust mounting angle to avoid reflective background
2. Strong ambient light directly irradiating the receiver lens2. Install light shield to block strong direct light
3. Interférences électromagnétiques graves3. Route sensor cables away from power cables and ensure proper grounding
Fluctuating and unstable output signal1. Object stays at the detection boundary1. Fine-tune mounting distance to stay away from critical zone
2. Dust or dirt covering the lens2. Clean the lens with a soft dry cloth
  1. Modèles alternatifs

Upgraded model of the same brand: PR18-BC10DNO (Nickel-copper alloy metal housing with higher mechanical strength, paramètres électriques identiques)

Cross-brand equivalent alternatives: OMRON E3Z-D61, Schneider XUB5BNANL2

PR18S-BC10DNO is a standard M18 plastic housing diffuse-reflective photoelectric sensor manufactured by LANBAO. See physical specifications below:

  1. Detailed Mounting Dimensions

This sensor adopts threaded cylindrical mounting. Dimensions and mounting regulations are specified as follows:

ArticleSpécification
Main ThreadM18 × 1mm (Metric fine thread)
Effective Thread Length30mm
Sensor Body Length (Excluding cable/connector)Environ. 53.5mm (cable version)
Sensing Face DiameterΦ18mm
Accessoires standards2 pcs M18 lock nuts, 1 pc anti-loose washer
Recommended Mounting HoleΦ18.5mm through hole
Minimum Spacing for Side-by-Side Installation≥40mm (to prevent optical crosstalk)

Mounting Instructions

  1. Fix the sensor on cabinet panels, brackets and other mounting positions via two lock nuts; the extension length is adjustable.
  2. Align the sensing face towards the moving direction of measured objects. The tilt angle is recommended ≤15°, otherwise the effective sensing distance will be reduced.
  3. This is a non-flush mount sensor. Do not embed the sensing face into metal mounting surface; keep the sensing face fully exposed.
  4. Définition du câblage & Connection Instructions

9.1 Standard Cable Version (Suffix -E2, 2m PVC Cable, 3-fil)

Couleur du filFonctionDescription
BrunPower Positive (V+)Connect to 10~30VDC positive terminal
BleuPower Negative (GND)Connect to power 0V / negative terminal
NoirSortie de signal (DEHORS)NPN Normally Open (NON) sortir

9.2 Wiring Principle of NPN NO Output

This model is NPN sinking output:

When no object is detected: Output terminal is floating, internal transistor cuts off with no signal output.

When object is detected: Internal transistor turns on, black output wire connects to blue power negative terminal and outputs low level (0V).

Câblage typique (Connect to PLC Sinking Input)

Brown wire → 24V+ of switching power supply

Blue wire → 0V of switching power supply & PLC common terminal (COM)

Black wire → PLC digital input terminal

Wiring for Relay / Indicator Load

One end of load connects to 24V+, the other end connects to sensor black output wire.

Sensor blue wire connects to 24V-.

Single-channel load current shall not exceed 300mA. Pour charges inductives, connect a freewheeling diode in reverse parallel.

9.3 M12 Connector Version (Suffixe -C, 4-pin Male Connector)

Pin assignment (View from sensing face, numbered clockwise):

  1. Épingle 1: Brun (Pouvoir +)
  2. Épingle 3: Bleu (Pouvoir -)
  3. Épingle 4: Noir (Sortie de signal)
  4. Épingle 2: De rechange (Inutilisé)
  5. Montage & Précautions de câblage
  6. Protection de polarité: Do not reverse power polarity. The built-in reverse polarity protection prevents burnout, but the sensor will not work normally under reversed connection.
  7. Load Limit: Maximum output load current is 300mA. Do not drive high-power loads directly; use intermediate relays for transition.
  8. Exigences environnementales: Avoid direct sunlight or strong LED light on the sensing window, and keep away from mirror or polished metal reflective surfaces in the background.
  9. EMC Requirements: Separate sensor cables from power cables (onduleur, servo cables) with a distance of ≥20cm. Do not lay them in the same conduit.

Précédent:

Suivant:

Laisser une réponse