Omron CS1W-OD231 PLC Expansion Module

CS1W: Prefix for CS-series PLC expansion modules OD: Output Digital, module de sortie numérique 231: Model revision number Product family: OMRON CS1 series large-scale PLC (rack-mounted module, used with CS1 CPU backplane) Key Specifications Item Parameter Module Type Transistor output (sinking NPN) Number of Outputs 32 points Rated Load Voltage DC 12~24V Current per Point 0.5A ...

  • Détails du produit

CS1W: Prefix for CS-series PLC expansion modules

DE: Output Digital, module de sortie numérique

231: Model revision number

Famille de produits: OMRON CS1 series large-scale PLC (rack-mounted module, used with CS1 CPU backplane)

Spécifications clés

ArticleParamètre
Type de moduleSortie transistorisée (sinking NPN)
Number of Outputs32 points
Rated Load VoltageDC 12~24V
Current per Point0.5UN / indiquer; max common group current 4A
Output IsolationIsolation par optocoupleur
Terminaux2 × 20-pin connectors (2 groupes, 16 points par groupe)
Temps de réponseOFF→ON: ≤0.1ms; MARCHE→ARRÊT: ≤0.4ms
Compatible BackplaneCS1W-BC series backplane (Support CS1)
Consommation d'énergie5À DC: 0.35UN (powered from PLC backplane)
Output Circuit32 points divided into 2 common groups, 16 points sharing one COM per group

Description de la fonction

  1. 32-channel NPN transistor sinking output: Load connected to positive DC24V. When the output point turns ON, it pulls the signal down to GND.
  2. Charges adaptées: DC24V small relays, voyants lumineux, solid state relays (RSS). Not for direct drive of high-power solenoid valves (intermediate relay required for current amplification).
  3. This is a CS1-series I/O expansion module and cannot operate standalone. It must be installed on a CS1 CPU rack or expansion rack.
  4. I/O Address: Automatically assigned by CS1 PLC according to the slot position on the backplane.

Directives de câblage

COM terminals connect to DC24V negative (for NPN sinking)

Output terminal → Load → DC24V+

Charges inductives (bobines) are recommended to connect a freewheeling diode in parallel to suppress reverse EMF and prevent transistor damage.

Alternatives courantes & Compatibilité

Same series comparison:

CS1W-OD211: 16-point transistor output

CS1W-OD231: 32-point de naufrage du NPN (le plus largement utilisé)

CS1W-OD261: 32-point PNP sourcing

Replacement note: Sinking and sourcing outputs cannot be swapped directly. Verify field load wiring before substitution.

Dépannage

  1. Aucune action de sortie: Check slot number, PLC I/O allocation, program output bit status; measure COM power supply and load circuit.
  2. Panne d'un seul canal: Usually caused by inductive loads without freewheeling diodes, resulting in permanent transistor breakdown.
  3. Module error: Insufficient backplane 5V power supply or poor module contact. Remove the module, clean gold fingers and re-seat.

Référence du code SH (Foreign Trade)

85371011 (Digital input/output module for programmable logic controllers)

Scénarios d'application

Automation production lines, machines d'emballage, metallurgical and HVAC complete sets of equipment; high-density DC24V discrete output for CS1 large PLC systems.

CS1W-OD231 Replacement Schemes

CS1W-OD231: CS1 series, 32-sortie transistor NPN descendante, DC12–24V, 0.5A/point, 2×20-pin connectors. The CS1 series has been discontinued. Three replacement categories: Same rack direct replacement (minor modification), Mise à niveau inter-séries (complete system retrofit), Remplacement compatible domestique.

Schème 1: Same CS Rack Replacement (Priorité, Modification minimale)

Applicable when original CS1 CPU + CS1 backplane remain intact, only the I/O module needs replacement.

  1. New spare: CS1W-OD231 (original stock / used tested unit)

✅ Identical I/O address, programme, wiring and connectors. Zero program modification, plug-and-play replacement.

⚠️ Discontinued by manufacturer; only surplus stock or tested second-hand units available. Inspect gold fingers and test output channels before use.

  1. Alternative de même série: CS1W-OD232

Consistent specifications, 32-point NPN; hardware pin compatible.

Différence: Updated internal circuit revision. No program modification required, remplacement direct.

Prudence: Do not confuse with CS1W-OD261 (32-point PNP sourcing). COM polarity is reversed, direct replacement will burn loads.

Schème 2: System Upgrade to CJ Series (Official OMRON Recommendation for Discontinued Product)

Modèle recommandé: CJ1W-OD231 (32-point de naufrage du NPN, fully matched parameters to CS1W-OD231)

Key Specification Comparison

ArticleCS1W-OD231CJ1W-OD231
Sortir32-point NPN sinking DC12–24V32-point NPN sinking DC12–24V
Current per Point0.5UN0.5UN
Connecteur2×20-pin2×20-pin
Allocation d'E/SSlot-based automatic assignmentSlot-based automatic assignment

Critical Retrofit Differences

  1. Backplane incompatibility: CS backplane cannot accommodate CJ modules. CJ-series CPU and CJ backplane must be replaced.
  2. Programme: Most instructions compatible. CX-Programmer project can be saved and converted; verify and adjust special instructions, memory addresses and CPU bus commands.
  3. Two wiring options

Option A (cost saving, recrimp cables): Replace XW2Z cables and XW2R terminal blocks, rewire all field connections.

Option B (minimal rewiring, official adapter): CJ1W-AT631 conversion adapter. Reuse original CS1W-OD231 terminal block and field cables without re-routing, significantly reduce site commissioning work.

CJ2 Series Upgrade Option (Performances supérieures)

CJ2M/CJ2H racks support CJ1W-OD231 (CJ1W I/O modules work on CJ2 backplanes);

CJ2M CPU cannot accept CS modules directly due to different backplane structure.

Schème 3: Série NX (Full System Renewal for New Projects)

NX series NX-OD6121, 32-sortie transistor NPN, EtherCAT bus module.

✅ Higher performance, supports remote I/O;

❌ Heavy modification: Full system replacement with NX CPU + Bus EtherCAT. Original backplane and I/O addressing structure discarded, extensive program reconstruction required. Suitable for whole-line technical transformation, not single module replacement.

Schème 4: Remplacement compatible domestique (Cost-Optimized for New Projects / Des pièces de rechange)

Domestic PLC modules (Innovation, Xinje etc.), 32-point NPN DC24V transistor output modules.

Avantages: Short lead time, moindre coût;

Inconvénients: Incompatible rack, bus and I/O addressing logic. Program rewrite + full rewiring required. Only for complete PLC replacement, not single module swap.

Replacement Risk Checklist (Mandatory Before Onsite Replacement)

  1. ✅ Confirm output type: Naufrage du NPN. Load wiring: OUT → Load → DC24V+, COM à 0V; avoid PNP sourcing by mistake.
  2. ✅ Inductive loads (électrovannes, relay coils) must use parallel freewheeling diodes to protect output channels.
  3. ✅ Single-point load current ≤0.5A, module total output current ≤4A.
  4. ✅ Connectors: 2 × 20-pin, cable series XW2Z, terminal block XW2R.
  5. ✅ Program: After CS→CJ migration, perform I/O address validation and forced output test to prevent address offset.

Résumé de la sélection

  1. Existing CS system healthy, only damaged module replacement: Prioritize original CS1W-OD231 stock / tested second-hand units;
  2. CS main unit aging, plan PLC upgrade but avoid large-scale rewiring: CJ1W-OD231 + CJ1W-AT631 conversion adapter;
  3. Whole line retrofit with EtherCAT requirement: série NX;
  4. Petit budget, full PLC replacement: Domestic modules.

No domestic rack module can be directly inserted into the original CS1 backplane or use the CS1 CPU private backplane bus (CS1 backplane protocol is proprietary OMRON protocol, domestic PLC backplanes are mutually incompatible).

Domestic replacement falls into two categories:

  1. Complete machine retrofit: Replace entire PLC with domestic rack PLC, select domestic 32-point NPN sinking DO module matching CS1W-OD231 specifications
  2. Distributed remote I/O solution: Retain original CS1 CPU, add bus coupler + domestic remote 32DO NPN module. No backplane disassembly required, minor program modification.

Core target specifications matching CS1W-OD231: 32-point DC24V NPN sinking transistor output; 0.5A/point; optocoupler isolation; 2 Groupes COM (16 points chacun); response time ≤0.4ms

  1. Rack-mounted Domestic PLC Modules (Full PLC Replacement, Recommended Brands)
  2. Innovation (Grand / Medium Rack PLC, Mainstream Industrial)

AM400 series: AM401-32DO-N

Spécifications: 32-point NPN sinking DC24V transistor output; 0.5A/point; 2 groups of 16-point common terminals, optocoupler isolation; bus de fond de panier, rack mounting.

Application: Replace complete CS1 system; original program needs porting/rewrite.

GL20 series: GL20-32DO-N (Compact rack module)

Spécifications: 32 NPN DC24V, 0.5A/point; EtherCAT backplane, réponse rapide; suitable for high-density I/O cabinets.

  1. HollySys (Domestic Large PLC, Widely Used in Automation Projects)

LK series LK610

Spécifications: 32-point DC24V NPN transistor output, 0.5A/point; grouped COM terminals, rack backplane, domestic large PLC module.

Application: Métallurgie, CVC, complete equipment packages, high reliability applications.

  1. Xinje (Medium Rack PLC, Rentable)

XF series XF-E32YT-N

Spécifications: 32-point NPN sinking DC24V transistor output; 0.5A/point; expansion rack module for XF/XSF CPU.

Caractéristiques: Domestic medium PLC, faible coût, suitable for packaging and general automation lines.

  1. NA Technology (Domestic Independent Controllable PLC)

NA series NA911: 32-point DC24V NPN transistor output rack module, 0.5A/point, for localization technical transformation projects.

  1. Domestic Distributed Remote I/O Modules (Retain Original CS1 CPU, Preferred Retrofit Option)

Principe: Add EtherCAT/ModbusTCP coupler to CS1 CPU, domestic remote I/O connected to bus. No CS backplane removal needed; only communication configuration and I/O mapping required.

  1. Hongchuang HC-32DO-N

32-point NPN sinking DC24V; 0.5A/point; EtherCAT/Profinet optional; optocoupler isolation, grouped COM. Terminal block version, direct field cable connection.

  1. Chenyue, Huatai, Inovance remote I/O

Inovance AM600-RTU-32DO-N: Modbus RTU remote 32DO NPN.

  1. Deckerwell, Lingkong distributed I/O

32DO-NPN EtherCAT module, widely deployed in industrial sites with proven stability.

III. Domestic Replacement Comparison Table

ArticleOMRON CS1W-OD231Inovance GL20-32DO-NXinje XF-E32YT-NHongchuang HC-32DO-N (Remote I/O)
Type de sortie32-point NPN sinking DC24V32-point NPN sinking DC24V32-point NPN sinking DC24V32-point NPN sinking DC24V
Current per Point0.5UN0.5UN0.5UN0.5UN
Grouping2×16 COM groups2×16 COM groups2×16 COM groups2×16 COM groups
MontageCS1 rack backplaneGL20 rack backplaneXF rack backplaneDIN rail remote bus
Compatible with Original CS Backplane❌ Proprietary OEM bus✅ Connect to CS1 CPU via bus coupler
Program ModificationAucun (original module)Full rewriteFull rewriteI/O address mapping, minor edits
  1. Replacement Risk Checklist (Points clés)
  2. Backplane non-interchangeable! All domestic rack modules cannot plug into CS1 backplane. This is a common misunderstanding. Only remote I/O scheme keeps original CS1 CPU.
  3. Output polarity must be NPN sinking. Do not purchase PNP sourcing modules, wiring is reversed and may damage loads.
  4. Charges inductives (électrovannes, relais) require parallel freewheeling diodes, same requirement for domestic modules.
  5. Total current limit: Module total current ≤4A, same as original CS1W-OD231.
  6. Address mapping: Remote I/O scheme requires FINS/Modbus/EtherCAT address mapping inside CS1 program. Control logic remains unchanged but I/O tags must be remapped.
  7. Recommandation de sélection
  8. Retain original CS1 CPU and backplane, only replace I/O points: Select EtherCAT domestic remote I/O (HC-32DO-N / Deckerwell 32DO-NPN) with EtherCAT coupler for CS1. Minimal modification.
  9. Full PLC aging, plan complete replacement to domestic system: Inovance AM400/GL20, HollySys LK; HollySys preferred for large complete projects, Inovance for general machinery.
  10. Limited budget, small equipment retrofit: Xinje XF series full replacement.