Nom complet du produit: Grooved photoelectric switch with built-in amplifier, 1 axe optique, Sortie PNP
✅ Model Code Explanation
E3Z: Series of capteur photoélectriques with built-in amplifier
G: Grooved / U-type through-beam
8: Sortie PNP (6 = NPN)
1: Single optical axis (2 = Dual optical axis)
Suffixe:
2M.: Fixed cable, 2m de longueur (Most common model in China)
-M3J 0.3M: M8 4-pin pre-wired connector, 0.3m lead
-M1J-1 0.3M: M12 4-pin pre-wired connector, 0.3m lead
📋 Core Technical Specifications
| Article | Paramètre |
| Méthode de détection | U-slot through-beam, single optical axis |
| Groove Width (Sensing Gap) | 25 mm |
| Source de lumière | LED infrarouge, 940nm |
| Standard Sensing Object | Opaque object ≥φ1.5mm |
| Alimentation | DC 12~24V (±10%) |
| Type de sortie | Collecteur ouvert PNP, charge maximale 100mA |
| Mode de fonctionnement | Lumière allumée / Dark-ON selectable |
| Temps de réponse | Operate / Reset ≤1ms |
| Consommation actuelle | ≤25mA |
| Protection | Reverse power protection, protection contre les courts-circuits de sortie, mutual interference resistance |
| Classe de protection | IP64 |
| Température de fonctionnement | -25℃ ~ +55℃ (No icing or condensation) |
| Matériau du boîtier | ABS |
| Ambient Light Immunity | Incandescent lamp ≤3000lx, Sunlight ≤10000lx |
🛠️ Application Scenarios
The grooved photoelectric sensor triggers signal when an object blocks the infrared beam inside the U-slot:
Conveyor material counting & détection de position
Home position / limit detection for cylinders and slides
Door switch detection for elevator and automation equipment
Label detection, notch detection for disc parts
High-speed sorting and stepping positioning (1ms response suitable for high-speed applications)
📌 Wiring Instruction (E3Z-G81 2M cable version, Brown/Blue/Black/White)
- Brun: DC+ 12~24V
- Bleu: DC0V
- Noir: PNP signal output wire
- Blanc: Mode selection wire (Lumière allumée / Dark ON)
White wire connected to DC+: Dark ON (Light-blocked ON, normally closed logic); White wire floating: Lumière allumée (Light-received ON, normally open logic)
⚠️ Model Selection & Troubleshooting Key Points
- Distinguish NPN/PNP: E3Z-G61 = NPN; E3Z-G81 = PNP. PLC input module polarity must match.
- Dust and debris accumulated in slot will block infrared light and cause false triggering; IP64 rating, NOT suitable for heavy water spray environments.
- Detected object must be opaque; transparent plastic or thin translucent sheets cannot be reliably detected.
- Dual optical axis model: E3Z-G82, used to prevent false detection of single optical axis, for dual-position signal acquisition.
🔁 Replacement Reference
Alternative nationale: U-groove photoelectric sensor, 25mm slot width, PNP, DC24V, 1réponse de Mme (compatible avec OMRON E3Z-G series, brands like Shenwu, Senso etc.)
Interchange within series: E3Z-G81 (Single axis PNP) ↔ E3Z-G61 (Single axis NPN); E3Z-G82 (Dual axis PNP)
HS Code Reference
85414090 (Photosensitive semiconductor device, capteur photoélectrique, for customs declaration only, subject to customs final verification)
OMRON E3Z-G81 Grooved Photoelectric Sensor Installation Guide
Modèles applicables: E3Z-G81 (2m de câble), E3Z-G81-M3J (M8 0.3m pre-wired connector, PNP single-axis grooved photoelectric)
25mm groove width, built-in amplifier, IP64, DC12 ~ 24 V, Lumière allumée / Dark ON selectable
- Inspection avant installation
- Unboxing Verification
Confirm model E3Z-G81; Inspect housing, transmitter/receiver windows inside slot for scratches, damage and oil contamination
Check cable integrity; Confirm orange operation indicator is intact
- Vérification de l'environnement
Température ambiante: -25℃ ~ +55℃, pas de givrage ni de condensation
Prohibited: Direct sunlight / strong incandescent light on optical path, gaz corrosif, continuous water spray, heavy dust accumulation, heavy vibration and shock
Avoid routing signal cable closely in parallel with inverter, contactor and power cables (EMI causes false triggering)
- Workpiece Verification
Sensing object: Opaque solid, minimum detectable size ≥φ1.5mm; Thin transparent sheets cannot be reliably sensed
Workpiece moving direction: Pass perpendicularly through the optical axis of U-slot, avoid sweeping the beam diagonally
- Procédure d'installation mécanique
2.1 Méthode de montage
E3Z-G81 housing has built-in M3 mounting holes, fixed with M3 screws
Couple de serrage recommandé: ≤0.5 N·m. Excessive torque may crack ABS housing. Never strike sensor body with hammer; it will damage IP seal and optical path.
Optional OMRON E39 mounting bracket for rack installation
2.2 Position de montage & Optical Path Requirements (Critique)
- Workpiece must fully pass through the optical axis at center of U-slot and completely cut off infrared beam when blocked
- Keep clearance between workpiece and slot wall. Do not scratch transmitter/receiver window to avoid lens scratch and dust buildup
- Workpiece thickness: Opaque material is acceptable; Workpiece entering/exiting slot must not impact sensor housing
- Multiple grooved sensors mounted side by side: Keep sufficient spacing to prevent mutual optical interference
- Sensor may be mounted directly on metal frame; U-groove type is immune to reflection from nearby metal surfaces.
✅ Installation Verification: Orange indicator toggles when workpiece enters slot to block beam, and recovers after workpiece exits.
2.3 Cable Installation Specification
- Cable bending radius ≥ 4 × cable outer diameter; Avoid repeated bending near cable root; Max cable tension ≤50N. Never pull sensor body by cable force
- Separate signal cable and power cable into different conduits, not in same trunking; If parallel routing is unavoidable, maintain ≥10cm spacing
- Cable extension: Extended wire cross-section ≥0.3mm², total length ≤100m; Insulate terminals properly
- Connector version (E3Z-G81-M3J): Do not pull cable during M8 connector plug/unplug; Tighten thread fully; Inspect connector seal regularly
- Câblage électrique (Perform under power OFF! Wiring with power ON is prohibited)
3.1 Cable outlet model (E3Z-G81, 4-cœur: Brun, Bleu, Noir, Blanc)
| Couleur du fil | Définition | Note |
| Brun | CC+ | 12~24V DC Positive |
| Bleu | CC- | 0V Negative |
| Noir | Sortie PNP | Connect to PLC input point, charge maximale 100mA |
| Blanc | Mode Selection Wire | Floating = Light ON; Connected to DC+ = Dark ON |
Sortie PNP: High level active; PLC input module requires sourcing input.
3.2 M8 Connector Model E3Z-G81-M3J (4-épingle)
Broche1: Brown DC+; Broche3: Blue DC-; Broche4: Sortie noire; Broche2: White Mode Selection (can be left unused)
3.3 Pre-power Check
Power supply DC12~24V, ±10%; Do NOT connect AC220V
Confirm power polarity without reverse connection; Sensor has built-in reverse polarity & protection contre les courts-circuits, but wiring verification is still required
Charger (PLC input) wired correctly; Never short output directly
- Étapes de mise en service à la mise sous tension
- Complete mechanical fixing and wiring with power OFF, double check
- Allumer, slot unblocked (beam passes):
Lumière allumée (white wire floating): Beam received, orange LED ON, PNP output activated
Dark ON (white wire connected to +24V): Beam received, orange LED OFF, output deactivated
- Insert opaque workpiece into slot to block optical path:
Lumière allumée: Faisceau bloqué, indicator OFF, output deactivated
Dark ON: Faisceau bloqué, indicator ON, PNP output activated
- Test workpiece in/out repeatedly to verify stable indicator and PLC signal
- If signal jitters, vérifier: ① Workpiece fully blocks beam; ② Dust on window; ③ EMI from power cable; ④ Loose mounting and vibration
- Entretien
- Regular cleaning of transmitter and receiver windows inside U-slot: Wipe gently with lint-free cloth and anhydrous alcohol. Hard brush and strong solvent (acetone, thinner) are forbidden; they corrode ABS and optical lens
- Periodic inspection: Loose screws, damaged cable jacket, water/oil ingress at connector
- Increase cleaning frequency for heavy dust environment
- Prohibited: Direct water or oil spray onto sensor body
- Tabous d’installation & Notes de sécurité
- Not for explosive hazardous area
- Cannot be immersed or continuously splashed; IP64 only protects against splashing water
- Do not touch internal infrared LED by hand
- High vibration equipment: Add lock washers and retorque screws periodically
- Never unplug cable or disassemble sensor when powered ON
- Quick Troubleshooting for Common Installation Issues
| Symptôme | Cause possible | Solution |
| Indicator not lit after power on | Pas d'alimentation, polarité inversée | Measure DC24V between Brown & Bleu, recheck wiring |
| Continuous output without workpiece blocking | Wrong operation mode; Dust on lens transmits light; Strong ambient light interference | Switch mode; Clean lens; Avoid direct strong light |
| No signal when workpiece blocks beam | Workpiece translucent; Beam not fully cut; Décalage de montage | Replace opaque workpiece; Adjust sensor position to ensure beam cut-off |
| Intermittent signal fluctuation | Loose mounting; EMI from power cable; Debris in slot | Tighten screws; Separate cable routing; Clean dust/debris in slot |
OMRON E3Z-G81 Grooved Photoelectric Sensor with Built-in Amplifier
Complete Product Manual (Anglais, sourced from OMRON official E3Z-G datasheet)
Modèles applicables: E3Z-G81 2M (2m de câble fixe), E3Z-G81-M3J (Connecteur M8 à 4 broches, 0.3m lead)
- Présentation du produit
E3Z-G81 is U-shaped grooved through-beam photoelectric sensor with built-in amplifier, single optical axis, PNP open-collector output; groove width 25mm. Detects objects when opaque material blocks infrared beam inside U-slot. Switchable between Light ON / Dark ON, response time ≤1ms, suitable for high-speed positioning, counting and home detection.
Classement des séries:
E3Z-G81: Single axis PNP; E3Z-G82: Dual axis PNP
E3Z-G61: Single axis NPN; E3Z-G62: Dual axis NPN
- Composition du modèle
E3Z-G81
E3Z: Photoelectric sensor series with built-in amplifier
G: Grooved U-slot type
8: Sortie PNP (6=NPN)
1: Single optical axis (2=Dual optical axis)
Suffixe:
2M.: Fixed cable, length 2m (version standard)
-M3J: M8 4-pin pre-wired connector, 0.3m lead
- Rated Specifications & Performance
| Article | Paramètre |
| Méthode de détection | Grooved through-beam (U-slot) |
| Groove Width (Sensing Gap) | 25 mm |
| Number of Optical Axes | 1 axe optique |
| Source de lumière | LED infrarouge, wavelength 940nm |
| Standard Sensing Object | Opaque object ≥φ1.5mm; Transparent object cannot be reliably sensed |
| Tension d'alimentation | DC12~24V ±10%, ripple p-p ≤10% |
| Consommation actuelle | ≤25mA |
| Sortie de contrôle | Collecteur ouvert PNP; Max load current 100mA; Residual voltage ≤1V; Max load supply DC26.4V |
| Mode de fonctionnement | Lumière allumée / Dark ON, selected by white control wire |
| Temps de réponse | Operate / Reset ≤1ms |
| Protection Circuit | Reverse power protection, protection contre les courts-circuits de sortie, mutual interference prevention |
| Ambient Illuminance (Récepteur) | Incandescent lamp ≤3000lx; Sunlight ≤10000lx |
| Température de fonctionnement | -25℃ ~ +55℃ (Pas de glaçage, pas de condensation) |
| Température de stockage | -40℃ ~ +70℃ |
| Humidité | Opération:35~85% HR; Stockage:35~95%HR (Pas de condensation) |
| Résistance d'isolation | ≥20 MΩ (DC500V, between cables and housing) |
| Tension de tenue | AC1000V, 50/60Hz, 1min (between cables and housing) |
| Vibration Durability | 10~55Hz, full amplitude1.5mm, X/Y/Z axes for 2h each |
| Shock Durability | 500m/s², X/Y/Z axes, 3 times each |
| Classe de protection | IP64 (Norme CEI, splash-proof, NOT immersion-proof) |
| Matériau du boîtier | ABS |
| Indicateur | Orange operation indicator |
| Poids | 2M cable version ≈65g; M8 connector version≈30g |
| MTTFd | 817 années |
- Dimension Outline (Unité: mm)
U-shaped body, Trous de montage M3; 25mm slot opening, two built-in M3 screw holes.
Couple de serrage recommandé: ≤0.5 N·m. Excessive torque may crack housing.
Accessoire en option: E39 mounting bracket (vendu séparément)
- Définition du câblage
5.1 Cable Outlet Version E3Z-G81 2M (4-cœur: Brun, Bleu, Noir, Blanc)
| Couleur du fil | Signal | Description |
| Brun | CC+ | DC12~24V Positive |
| Bleu | CC- | 0V Negative |
| Noir | Sortie PNP | Sortie de signal, connect to PLC sourcing input |
| Blanc | Mode Selection Wire | Floating = Light ON; Connected to DC+ = Dark ON |
5.2 M8 Connector Version E3Z-G81-M3J (4-épingle)
| Numéro de broche. | Corresponding Wire | Fonction |
| 1 | Brun | CC+ |
| 3 | Bleu | CC- |
| 4 | Noir | Sortie PNP |
| 2 | Blanc | Mode Selection Wire |
✅ Operation Logic
- Lumière allumée (White wire floating, défaut d'usine)
Beam unblocked (no obstruction): Orange LED ON, PNP output ON (Haut niveau);
Faisceau bloqué: Orange LED OFF, output OFF.
- Dark ON (White wire connected to DC+)
Beam unblocked (no obstruction): Orange LED OFF, output OFF;
Faisceau bloqué: Orange LED ON, PNP output ON (Haut niveau).
- Exigences d'installation
- Fix with M3 screws, add lock washer, torque ≤0.5N·m. Do not strike sensor body.
- Workpiece passes perpendicularly through U-slot optical axis; workpiece movement must not scratch or impact transmitter/receiver window.
- Keep enough spacing for multiple grooved sensors mounted side by side to prevent mutual optical interference.
- Separate signal cable and power cable; ≥100mm spacing if parallel routing is mandatory. Cable minimum bending radius ≥4 × cable OD; Max cable tension ≤50N.
- Environnement d'installation: Avoid direct strong light on optical path, gaz corrosif, continuous water spray and heavy dust accumulation.
- Étapes de mise en service
- Wire with power OFF, confirm no AC220V miswiring, check polarity.
- Allumer, slot unobstructed, observe orange indicator to verify operation mode.
- Insert opaque workpiece into slot to cut beam, observe indicator state flip and verify PLC input signal.
- Repeat workpiece in/out test to confirm stable signal without jitter.
- Entretien
- Regular cleaning of U-slot transmitter and receiver windows: Wipe gently with lint-free cloth dipped in anhydrous alcohol. Acetone, thinner and other strong solvents are forbidden; hard material scratch on lens is prohibited.
- Regular inspection for loose mounting screws, damaged cable jacket and connector seal integrity.
- Increase cleaning frequency for dusty environment. Do not spray water or oil directly onto sensor.
- Notes de sécurité
- This product cannot be used in explosive hazardous areas; IP64 only protects splash water and cannot resist immersion.
- Do NOT plug/unplug cable or disassemble sensor while powered ON.
- Load current of output must not exceed 100mA, otherwise internal circuit damage occurs.
- Do not touch infrared LED emitting surface by hand.
- This sensor is for general industrial detection, cannot be directly used as safety protective device (safety light curtain).
- Tableau de dépannage
| Phénomène de défaut | Cause première | Solution |
| Indicator not lit after power on | Pas d'alimentation, polarité d'alimentation inversée | Measure DC24V between Brown & Bleu, recheck wiring |
| Continuous output without workpiece blocking | Wrong mode setting; Dust on lens transmits light; Strong ambient light interference | Switch mode; Clean lens; Avoid direct strong light |
| No output signal when workpiece blocks beam | Workpiece translucent; Beam not cut fully; Décalage de montage | Replace opaque workpiece; Adjust sensor position |
| Intermittent signal jitter | Loose mounting; EMI from power cable; Dust/debris in slot | Tighten screws; Separate cable routing; Clean debris inside slot |
- Accessoires, Alternatives & Customs Reference
Interchange within series: E3Z-G81 (Single axis PNP) ↔ E3Z-G61 (Single axis NPN); E3Z-G82 Dual axis PNP
Alternative nationale: Groove photoelectric sensor, 25mm slot width, PNP output DC24V, response ≤1ms
HS Code Reference: 85414090 (Photosensitive semiconductor device, for customs declaration only, subject to customs final verification)
Si nécessaire, I can further provide:
- A4 one-page printable condensed English manual
- Wiring schematic for E3Z-G81 to Siemens PLC sourcing input
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur





















NH42-63-318x560.png)