OMRON E3Z-G81 Grooved (U-Type) Capteur photoélectrique - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 OMRON E3Z-G81 Grooved (U-Type) Capteur photoélectrique - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

électrique/

OMRON E3Z-G81 Grooved (U-Type) Capteur photoélectrique

Nom complet du produit: Grooved photoelectric switch with built-in amplifier, 1 axe optique, PNP output ✅ Model Code Explanation E3Z: Series of photoelectric sensors with built-in amplifier G: Grooved / U-type through-beam 8: Sortie PNP (6 = NPN) 1: Single optical axis (2 = Dual optical axis) Suffixe: 2M.: Fixed cable, 2m de longueur (Most common model ...

  • Détails du produit

Nom complet du produit: Grooved photoelectric switch with built-in amplifier, 1 axe optique, Sortie PNP

✅ Model Code Explanation

E3Z: Series of capteur photoélectriques with built-in amplifier

G: Grooved / U-type through-beam

8: Sortie PNP (6 = NPN)

1: Single optical axis (2 = Dual optical axis)

Suffixe:

2M.: Fixed cable, 2m de longueur (Most common model in China)

-M3J 0.3M: M8 4-pin pre-wired connector, 0.3m lead

-M1J-1 0.3M: M12 4-pin pre-wired connector, 0.3m lead

📋 Core Technical Specifications

ArticleParamètre
Méthode de détectionU-slot through-beam, single optical axis
Groove Width (Sensing Gap)25 mm
Source de lumièreLED infrarouge, 940nm
Standard Sensing ObjectOpaque object ≥φ1.5mm
AlimentationDC 12~24V (±10%)
Type de sortieCollecteur ouvert PNP, charge maximale 100mA
Mode de fonctionnementLumière allumée / Dark-ON selectable
Temps de réponseOperate / Reset ≤1ms
Consommation actuelle≤25mA
ProtectionReverse power protection, protection contre les courts-circuits de sortie, mutual interference resistance
Classe de protectionIP64
Température de fonctionnement-25℃ ~ +55℃ (No icing or condensation)
Matériau du boîtierABS
Ambient Light ImmunityIncandescent lamp ≤3000lx, Sunlight ≤10000lx

🛠️ Application Scenarios

The grooved photoelectric sensor triggers signal when an object blocks the infrared beam inside the U-slot:

Conveyor material counting & détection de position

Home position / limit detection for cylinders and slides

Door switch detection for elevator and automation equipment

Label detection, notch detection for disc parts

High-speed sorting and stepping positioning (1ms response suitable for high-speed applications)

📌 Wiring Instruction (E3Z-G81 2M cable version, Brown/Blue/Black/White)

  1. Brun: DC+ 12~24V
  2. Bleu: DC0V
  3. Noir: PNP signal output wire
  4. Blanc: Mode selection wire (Lumière allumée / Dark ON)

White wire connected to DC+: Dark ON (Light-blocked ON, normally closed logic); White wire floating: Lumière allumée (Light-received ON, normally open logic)

⚠️ Model Selection & Troubleshooting Key Points

  1. Distinguish NPN/PNP: E3Z-G61 = NPN; E3Z-G81 = PNP. PLC input module polarity must match.
  2. Dust and debris accumulated in slot will block infrared light and cause false triggering; IP64 rating, NOT suitable for heavy water spray environments.
  3. Detected object must be opaque; transparent plastic or thin translucent sheets cannot be reliably detected.
  4. Dual optical axis model: E3Z-G82, used to prevent false detection of single optical axis, for dual-position signal acquisition.

🔁 Replacement Reference

Alternative nationale: U-groove photoelectric sensor, 25mm slot width, PNP, DC24V, 1réponse de Mme (compatible avec OMRON E3Z-G series, brands like Shenwu, Senso etc.)

Interchange within series: E3Z-G81 (Single axis PNP) ↔ E3Z-G61 (Single axis NPN); E3Z-G82 (Dual axis PNP)

HS Code Reference

85414090 (Photosensitive semiconductor device, capteur photoélectrique, for customs declaration only, subject to customs final verification)

OMRON E3Z-G81 Grooved Photoelectric Sensor Installation Guide

Modèles applicables: E3Z-G81 (2m de câble), E3Z-G81-M3J (M8 0.3m pre-wired connector, PNP single-axis grooved photoelectric)

25mm groove width, built-in amplifier, IP64, DC12 ~ 24 V, Lumière allumée / Dark ON selectable

  1. Inspection avant installation
  2. Unboxing Verification

Confirm model E3Z-G81; Inspect housing, transmitter/receiver windows inside slot for scratches, damage and oil contamination

Check cable integrity; Confirm orange operation indicator is intact

  1. Vérification de l'environnement

Température ambiante: -25℃ ~ +55℃, pas de givrage ni de condensation

Prohibited: Direct sunlight / strong incandescent light on optical path, gaz corrosif, continuous water spray, heavy dust accumulation, heavy vibration and shock

Avoid routing signal cable closely in parallel with inverter, contactor and power cables (EMI causes false triggering)

  1. Workpiece Verification

Sensing object: Opaque solid, minimum detectable size ≥φ1.5mm; Thin transparent sheets cannot be reliably sensed

Workpiece moving direction: Pass perpendicularly through the optical axis of U-slot, avoid sweeping the beam diagonally

  1. Procédure d'installation mécanique

2.1 Méthode de montage

E3Z-G81 housing has built-in M3 mounting holes, fixed with M3 screws

Couple de serrage recommandé: ≤0.5 N·m. Excessive torque may crack ABS housing. Never strike sensor body with hammer; it will damage IP seal and optical path.

Optional OMRON E39 mounting bracket for rack installation

2.2 Position de montage & Optical Path Requirements (Critique)

  1. Workpiece must fully pass through the optical axis at center of U-slot and completely cut off infrared beam when blocked
  2. Keep clearance between workpiece and slot wall. Do not scratch transmitter/receiver window to avoid lens scratch and dust buildup
  3. Workpiece thickness: Opaque material is acceptable; Workpiece entering/exiting slot must not impact sensor housing
  4. Multiple grooved sensors mounted side by side: Keep sufficient spacing to prevent mutual optical interference
  5. Sensor may be mounted directly on metal frame; U-groove type is immune to reflection from nearby metal surfaces.

✅ Installation Verification: Orange indicator toggles when workpiece enters slot to block beam, and recovers after workpiece exits.

2.3 Cable Installation Specification

  1. Cable bending radius ≥ 4 × cable outer diameter; Avoid repeated bending near cable root; Max cable tension ≤50N. Never pull sensor body by cable force
  2. Separate signal cable and power cable into different conduits, not in same trunking; If parallel routing is unavoidable, maintain ≥10cm spacing
  3. Cable extension: Extended wire cross-section ≥0.3mm², total length ≤100m; Insulate terminals properly
  4. Connector version (E3Z-G81-M3J): Do not pull cable during M8 connector plug/unplug; Tighten thread fully; Inspect connector seal regularly
  5. Câblage électrique (Perform under power OFF! Wiring with power ON is prohibited)

3.1 Cable outlet model (E3Z-G81, 4-cœur: Brun, Bleu, Noir, Blanc)

Couleur du filDéfinitionNote
BrunCC+12~24V DC Positive
BleuCC-0V Negative
NoirSortie PNPConnect to PLC input point, charge maximale 100mA
BlancMode Selection WireFloating = Light ON; Connected to DC+ = Dark ON

Sortie PNP: High level active; PLC input module requires sourcing input.

3.2 M8 Connector Model E3Z-G81-M3J (4-épingle)

Broche1: Brown DC+; Broche3: Blue DC-; Broche4: Sortie noire; Broche2: White Mode Selection (can be left unused)

3.3 Pre-power Check

Power supply DC12~24V, ±10%; Do NOT connect AC220V

Confirm power polarity without reverse connection; Sensor has built-in reverse polarity & protection contre les courts-circuits, but wiring verification is still required

Charger (PLC input) wired correctly; Never short output directly

  1. Étapes de mise en service à la mise sous tension
  2. Complete mechanical fixing and wiring with power OFF, double check
  3. Allumer, slot unblocked (beam passes):

Lumière allumée (white wire floating): Beam received, orange LED ON, PNP output activated

Dark ON (white wire connected to +24V): Beam received, orange LED OFF, output deactivated

  1. Insert opaque workpiece into slot to block optical path:

Lumière allumée: Faisceau bloqué, indicator OFF, output deactivated

Dark ON: Faisceau bloqué, indicator ON, PNP output activated

  1. Test workpiece in/out repeatedly to verify stable indicator and PLC signal
  2. If signal jitters, vérifier: ① Workpiece fully blocks beam; ② Dust on window; ③ EMI from power cable; ④ Loose mounting and vibration
  3. Entretien
  4. Regular cleaning of transmitter and receiver windows inside U-slot: Wipe gently with lint-free cloth and anhydrous alcohol. Hard brush and strong solvent (acetone, thinner) are forbidden; they corrode ABS and optical lens
  5. Periodic inspection: Loose screws, damaged cable jacket, water/oil ingress at connector
  6. Increase cleaning frequency for heavy dust environment
  7. Prohibited: Direct water or oil spray onto sensor body
  8. Tabous d’installation & Notes de sécurité
  9. Not for explosive hazardous area
  10. Cannot be immersed or continuously splashed; IP64 only protects against splashing water
  11. Do not touch internal infrared LED by hand
  12. High vibration equipment: Add lock washers and retorque screws periodically
  13. Never unplug cable or disassemble sensor when powered ON
  14. Quick Troubleshooting for Common Installation Issues
SymptômeCause possibleSolution
Indicator not lit after power onPas d'alimentation, polarité inverséeMeasure DC24V between Brown & Bleu, recheck wiring
Continuous output without workpiece blockingWrong operation mode; Dust on lens transmits light; Strong ambient light interferenceSwitch mode; Clean lens; Avoid direct strong light
No signal when workpiece blocks beamWorkpiece translucent; Beam not fully cut; Décalage de montageReplace opaque workpiece; Adjust sensor position to ensure beam cut-off
Intermittent signal fluctuationLoose mounting; EMI from power cable; Debris in slotTighten screws; Separate cable routing; Clean dust/debris in slot

OMRON E3Z-G81 Grooved Photoelectric Sensor with Built-in Amplifier

Complete Product Manual (Anglais, sourced from OMRON official E3Z-G datasheet)

Modèles applicables: E3Z-G81 2M (2m de câble fixe), E3Z-G81-M3J (Connecteur M8 à 4 broches, 0.3m lead)

  1. Présentation du produit

E3Z-G81 is U-shaped grooved through-beam photoelectric sensor with built-in amplifier, single optical axis, PNP open-collector output; groove width 25mm. Detects objects when opaque material blocks infrared beam inside U-slot. Switchable between Light ON / Dark ON, response time ≤1ms, suitable for high-speed positioning, counting and home detection.

Classement des séries:

E3Z-G81: Single axis PNP; E3Z-G82: Dual axis PNP

E3Z-G61: Single axis NPN; E3Z-G62: Dual axis NPN

  1. Composition du modèle

E3Z-G81

E3Z: Photoelectric sensor series with built-in amplifier

G: Grooved U-slot type

8: Sortie PNP (6=NPN)

1: Single optical axis (2=Dual optical axis)

Suffixe:

2M.: Fixed cable, length 2m (version standard)

-M3J: M8 4-pin pre-wired connector, 0.3m lead

  1. Rated Specifications & Performance
ArticleParamètre
Méthode de détectionGrooved through-beam (U-slot)
Groove Width (Sensing Gap)25 mm
Number of Optical Axes1 axe optique
Source de lumièreLED infrarouge, wavelength 940nm
Standard Sensing ObjectOpaque object ≥φ1.5mm; Transparent object cannot be reliably sensed
Tension d'alimentationDC12~24V ±10%, ripple p-p ≤10%
Consommation actuelle≤25mA
Sortie de contrôleCollecteur ouvert PNP; Max load current 100mA; Residual voltage ≤1V; Max load supply DC26.4V
Mode de fonctionnementLumière allumée / Dark ON, selected by white control wire
Temps de réponseOperate / Reset ≤1ms
Protection CircuitReverse power protection, protection contre les courts-circuits de sortie, mutual interference prevention
Ambient Illuminance (Récepteur)Incandescent lamp ≤3000lx; Sunlight ≤10000lx
Température de fonctionnement-25℃ ~ +55℃ (Pas de glaçage, pas de condensation)
Température de stockage-40℃ ~ +70℃
HumiditéOpération:35~85% HR; Stockage:35~95%HR (Pas de condensation)
Résistance d'isolation≥20 MΩ (DC500V, between cables and housing)
Tension de tenueAC1000V, 50/60Hz, 1min (between cables and housing)
Vibration Durability10~55Hz, full amplitude1.5mm, X/Y/Z axes for 2h each
Shock Durability500m/s², X/Y/Z axes, 3 times each
Classe de protectionIP64 (Norme CEI, splash-proof, NOT immersion-proof)
Matériau du boîtierABS
IndicateurOrange operation indicator
Poids2M cable version ≈65g; M8 connector version≈30g
MTTFd817 années
  1. Dimension Outline (Unité: mm)

U-shaped body, Trous de montage M3; 25mm slot opening, two built-in M3 screw holes.

Couple de serrage recommandé: ≤0.5 N·m. Excessive torque may crack housing.

Accessoire en option: E39 mounting bracket (vendu séparément)

  1. Définition du câblage

5.1 Cable Outlet Version E3Z-G81 2M (4-cœur: Brun, Bleu, Noir, Blanc)

Couleur du filSignalDescription
BrunCC+DC12~24V Positive
BleuCC-0V Negative
NoirSortie PNPSortie de signal, connect to PLC sourcing input
BlancMode Selection WireFloating = Light ON; Connected to DC+ = Dark ON

5.2 M8 Connector Version E3Z-G81-M3J (4-épingle)

Numéro de broche.Corresponding WireFonction
1BrunCC+
3BleuCC-
4NoirSortie PNP
2BlancMode Selection Wire

✅ Operation Logic

  1. Lumière allumée (White wire floating, défaut d'usine)

Beam unblocked (no obstruction): Orange LED ON, PNP output ON (Haut niveau);

Faisceau bloqué: Orange LED OFF, output OFF.

  1. Dark ON (White wire connected to DC+)

Beam unblocked (no obstruction): Orange LED OFF, output OFF;

Faisceau bloqué: Orange LED ON, PNP output ON (Haut niveau).

  1. Exigences d'installation
  2. Fix with M3 screws, add lock washer, torque ≤0.5N·m. Do not strike sensor body.
  3. Workpiece passes perpendicularly through U-slot optical axis; workpiece movement must not scratch or impact transmitter/receiver window.
  4. Keep enough spacing for multiple grooved sensors mounted side by side to prevent mutual optical interference.
  5. Separate signal cable and power cable; ≥100mm spacing if parallel routing is mandatory. Cable minimum bending radius ≥4 × cable OD; Max cable tension ≤50N.
  6. Environnement d'installation: Avoid direct strong light on optical path, gaz corrosif, continuous water spray and heavy dust accumulation.
  7. Étapes de mise en service
  8. Wire with power OFF, confirm no AC220V miswiring, check polarity.
  9. Allumer, slot unobstructed, observe orange indicator to verify operation mode.
  10. Insert opaque workpiece into slot to cut beam, observe indicator state flip and verify PLC input signal.
  11. Repeat workpiece in/out test to confirm stable signal without jitter.
  12. Entretien
  13. Regular cleaning of U-slot transmitter and receiver windows: Wipe gently with lint-free cloth dipped in anhydrous alcohol. Acetone, thinner and other strong solvents are forbidden; hard material scratch on lens is prohibited.
  14. Regular inspection for loose mounting screws, damaged cable jacket and connector seal integrity.
  15. Increase cleaning frequency for dusty environment. Do not spray water or oil directly onto sensor.
  16. Notes de sécurité
  17. This product cannot be used in explosive hazardous areas; IP64 only protects splash water and cannot resist immersion.
  18. Do NOT plug/unplug cable or disassemble sensor while powered ON.
  19. Load current of output must not exceed 100mA, otherwise internal circuit damage occurs.
  20. Do not touch infrared LED emitting surface by hand.
  21. This sensor is for general industrial detection, cannot be directly used as safety protective device (safety light curtain).
  22. Tableau de dépannage
Phénomène de défautCause premièreSolution
Indicator not lit after power onPas d'alimentation, polarité d'alimentation inverséeMeasure DC24V between Brown & Bleu, recheck wiring
Continuous output without workpiece blockingWrong mode setting; Dust on lens transmits light; Strong ambient light interferenceSwitch mode; Clean lens; Avoid direct strong light
No output signal when workpiece blocks beamWorkpiece translucent; Beam not cut fully; Décalage de montageReplace opaque workpiece; Adjust sensor position
Intermittent signal jitterLoose mounting; EMI from power cable; Dust/debris in slotTighten screws; Separate cable routing; Clean debris inside slot
  1. Accessoires, Alternatives & Customs Reference

Interchange within series: E3Z-G81 (Single axis PNP) ↔ E3Z-G61 (Single axis NPN); E3Z-G82 Dual axis PNP

Alternative nationale: Groove photoelectric sensor, 25mm slot width, PNP output DC24V, response ≤1ms

HS Code Reference: 85414090 (Photosensitive semiconductor device, for customs declaration only, subject to customs final verification)

Si nécessaire, I can further provide:

  1. A4 one-page printable condensed English manual
  2. Wiring schematic for E3Z-G81 to Siemens PLC sourcing input

Précédent:

Suivant:

Laisser une réponse

Laisser un message