OMRON S8VK-T12024 DIN Rail Power Supply - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 OMRON S8VK-T12024 DIN Rail Power Supply - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

API/

OMRON S8VK-T12024 DIN Rail Power Supply

S8VK: OMRON S8VK series switching power supply T: Model for three-phase AC400V input 120: Rated power 120W 24: DC24V output Core Specifications Item Parameter Rated Input Three-phase AC380~480V; Operating range AC320~576V (works with three-phase or two-phase input), DC 450~810V Rated Output DC24V, 5UN, 120W Peak Output 120% surcharge (6UN) auto-recovery protection Efficiency Typical 89% Mounting DIN35 ...

  • Détails du produit

S8VK: OMRON S8VK series switching alimentation

T: Model for three-phase AC400V input

120: Rated power 120W

24: DC24V output

Spécifications de base

ArticleParamètre
Entrée nominaleThree-phase AC380~480V; Operating range AC320~576V (works with three-phase or two-phase input), DC 450~810V
Sortie nominaleDC24V, 5UN, 120W
Sortie de crête120% surcharge (6UN) auto-recovery protection
EfficacitéTypique 89%
MontageMontage sur rail DIN35, bornes à vis
Dimensions hors toutH125 × W40 × D113 mm
RefroidissementNatural convection cooling, sans ventilateur
Protection contre la pénétrationIP20
Température ambiante de fonctionnement-40~+70℃ (derating required at high temperature, pas de condensation ni de givrage)
Fonctions de protectionSurintensité (surcharge, récupération automatique), surtension (latch-off, reset by power cycle), undervoltage alarm
Fonctionnalités supplémentairesMax.. 2 units in series (external diode required); Conformal coated PCB optional; MTBF≥135,000 hours

Définition du terminal

  1. L1, L2, L3: Three-phase AC input
  2. PE: Terre de protection
  3. +V, -V: DC24V output
  4. V.ADJ: Output voltage trim potentiometer
  5. DC ON: Green indicator for normal output

Scénarios d'application typiques

Three-phase industrial control cabinets, machines-outils, équipement d'emballage, HVAC automatic control, 380V powered automated production lines, supplying DC24V for PLCs, capteurs, relays and valve islands.

In-series Comparison

S8VK-T12024: 120W / 5UN / Width 40mm

S8VK-T24024: 240W /10A / Width 60mm

S8VK-T48024: 480W /20A / Width 95mm

S8VK-T96024: 960W /40A

Référence de sélection alternative

  1. OMRON single-phase version: S8VK-C12024 (also 120W/24V, single-phase 220V input, ne confondez pas)
  2. Alternatives nationales: Meanwell DRT-120-24, Delta DRP0120, Phoenix Contact three-phase 24V/5A rail power supply

Directives de dépannage

  1. DC indicator off: Check three-phase input voltage, PE earthing, input circuit breaker; failure to start if two phases are missing
  2. Voltage drop under load: Load exceeds rated 5A; high-temperature derating; low input voltage
  3. Intermittent undervoltage alarm: Main circuit voltage fluctuation, loose terminal wiring
  4. Overvoltage latch-off: Triggered by output overvoltage, restore by power cycling; check for load short circuit / reverse voltage

OMRON S8VK-T12024 Detailed Technical Specifications

Three-phase 380V input DIN rail switching power supply, rated 120W DC24V/5A

  1. Spécifications d'entrée
ArticleParamètre
Rated Three-phase InputAC380~480V, 50/60Hz
Three-phase Operating Voltage RangeAC320~576V
Two-phase Input RangeAC340~576V (two-phase operation supported)
DC InputDC450~810V
Courant d'entréeEnviron. 0.45A @ AC400V full load
Courant d'appelInternally limited
Recommended Circuit BreakerB/C/D type, 5~20A (triphasé); 2~20A (two-phase)
Recommended Fuse600Vcc, 5A fast blow
  1. Output Specifications
ArticleParamètre
Rated Output VoltageDC24V
Courant de sortie nominal5UN
Puissance nominale120W
Output Adjustment Range24V±10 % (V.ADJ potentiometer)
Ondulation & Bruit120mVp-p (typique)
Capacité de surchargeOverload protection activates at 121% courant nominal, récupération automatique
Protection contre les surtensionsTriggered at approx.130% rated voltage, latches off output, reset by power cycle
Alarme de sous-tensionBuilt-in undervoltage detection signal
Parallel OperationMultiple units parallelable (follow current-sharing requirements)
Series OperationMax.. 2 units in series, external isolation diode required
  1. Isolation & Tension de tenue
  2. Input ↔ Output: AC3000V, 1min, cut-off current 20mA
  3. Input ↔ PE: AC2500V, 1min, cut-off current 20mA
  4. Output ↔ PE: AC1000V, 1min, cut-off current 30mA
  5. Résistance d'isolation: ≥100 MΩ (DC500V, between input/output/PE)
  6. Conditions environnementales
ArticleParamètre
Température de fonctionnement-40℃ ~ + 70 ℃ (derating required above 50℃, pas de condensation ni de givrage)
Température de stockage-40℃ ~ + 85 ℃
Humidité relative0~95%HR (opération & stockage, sans condensation)
Résistance aux vibrations10~55Hz, amplitude 0.375mm, 2 hours per axis for 3 axes
Résistance aux chocs150m/s², 3 shocks per direction for 6 instructions
Méthode de refroidissementNatural convection cooling, sans ventilateur
Protection contre la pénétrationIP20 (pour usage intérieur en armoire)
  1. Spécifications mécaniques

Montage: Montage sur rail DIN35 mm

Dimensions: H125 × W40 × D112.2 mm

Terminaux: Screw-type terminals

Poids: Environ. 600g

Facultatif: Conformal coated PCB version (anti-corrosion & étanche à la poussière)

  1. Fiabilité & Certifications

MTBF: ≥135,000 hours

Indicateur: Green DC ON lamp, illuminates when output ≥80~90% rated voltage

Certifications de sécurité: UL, ASC, CE and other global industrial standards

  1. Définition du terminal
  2. L1, L2, L3: Three-phase AC input
  3. PE: Terre de protection (must be earthed reliably)
  4. +V, -V: DC24V output
  5. V.ADJ: Output voltage trim potentiometer
  6. Summary of Protection Functions

✅ Overload protection (récupération automatique)

✅ Short-circuit protection (récupération automatique)

✅ Output overvoltage protection (latch-off, reset by power cycle)

✅ Built-in undervoltage monitoring

✅ Input surge suppression

  1. Notes critiques
  2. Derating is mandatory when ambient temperature>50℃
  3. Load capacity will be limited under two-phase input
  4. External diodes are mandatory for series connection; direct series connection is prohibited
  5. PE terminal must be reliably earthed to comply with safety standards

OMRON S8VK-T Three-phase DIN Rail Power Supply Full Series List

S8VK-T: Three-phase AC380~480V input, DC24V output, Montage sur rail DIN35, fanless natural cooling; suffixe -400 = conformal coated PCB (for dust, moisture and corrosive environments)

Modèles standards

ModèlePuissance nominaleSortirCourant nominalPeak Boost CurrentDimension W×H×D(mm)
S8VK-T12024120WDC24V5UN6UN40 × 125 × 112.2
S8VK-T24024240WDC24V10UN12UN60 × 125 × 140
S8VK-T48024480WDC24V20UN24UN95 × 125 × 140
S8VK-T96024960WDC24V40UN48UN135 × 125 × 170

Revêtement conforme (Anticorrosion) Modèles

Coated ModelCorresponding Standard ModelPouvoirRemarques
S8VK-T12024-400S8VK-T12024120WPCB with coating, for dusty and humid environments
S8VK-T24024-400S8VK-T24024240WPCB with coating
S8VK-T48024-400S8VK-T48024480WPCB with coating
S8VK-T96024-400S8VK-T96024960WPCB with coating

Liste des accessoires

Modèle d'accessoireDescriptionApplicable Units
S82Y-VK10FFront mounting bracketT12024 (120W)
S82Y-VK20FFront mounting bracketT24024 / T48024 (240W, 480W)
S8VK-R10Redundancy module 10AFor power redundancy with S8VK-T
S8VK-R20Redundancy module 20AFor power redundancy with S8VK-T

Common Specifications for Entire S8VK-T Series

  1. Saisir: Three-phase AC380~480V; operating range AC320~576V; two-phase input supported; DC450~810V DC input
  2. Sortir: DC24V, adjustable range 24V±10% (V.ADJ potentiometer)
  3. Protection: Surcharge / court-circuit (récupération automatique), output overvoltage latch-off (reset by power cycle), built-in undervoltage monitoring
  4. Environnement: Operating temperature -40℃ ~ +70℃, derating required above 50℃; fanless natural cooling; IP20 cabinet use
  5. Tension de tenue: Input↔Output AC3000V 1min; Input↔PE AC2500V 1min; Output↔PE AC1000V 1min
  6. Montage: rail DIN35, bornes à vis; multiple units parallelable for capacity expansion; maximum. 2 units in series (external diode required)

Quick Selection Tips

All models are single DC24V output. S8VK-T series has no other voltage options (12V/48V not available in T series)

Modèle sans -400: Standard PCB for normal control cabinets; with `-400`: Coated board for dusty, humid and corrosive gas environments

S8VK-T is three-phase power supply, do not confuse with single-phase S8VK-C / S8VK-G

Redundant power supply requires separate S8VK-R redundancy module

OMRON S8VK-T Three-phase DIN Rail Power Supply Cross-Brand Model Comparison Table

Matching prerequisites: Three-phase AC380~480V input, DC24V output, DIN35 rail mount, fanless natural cooling. Grouped into【Premium International Brands】【Taiwan Brands】【Domestic Industrial Brands】; replacement rating marked. ⚠️Differences exist in dimension, terminal layout, BOOST capability and PCB coating. Drawings must be verified for direct replacement.

OMRON Original ModelSpec.Contact PhénixMeanwellMeanwell RemarksSiemensDelta
S8VK-T12024 (120W/5A)3-phase 380V input 24V 5AQUINT4-PS/3AC/24DC/5 PN:2904620TDR-120-24DRT-120 obsolete; TDR is replacement; three-phase input, sans ventilateur6EP3436-8SB00-0AY0DRL-24V120W3ENA
S8VK-T24024 (240W/10A)3-phase 380V input 24V 10ATRIO-PS/3AC/24DC/10 2866459TDR-240-24DRT-240 obsolete; new TDR, parallelable6EP3437-8SB00-0AY0DRL-24V240W3ENA
S8VK-T48024 (480W/20A)3-phase 380V input 24V 20ATRIO-PS/3AC/24DC/20 2866462TDR-480-24DRT-480 obsolete; new TDR, parallel expansion supported6EP3438-8SB00-0AY0DRL-24V480W3ENA
S8VK-T96024 (960W/40A)3-phase 380V input 24V 40ATRIO-PS/3AC/24DC/40 2866404TDR-960-24DRT-960 obsolete; new TDR, max 40A output6EP3440-8SB00-0AY0DRL-24V960W3ENA

Version à revêtement conforme (-400 Anticorrosion) Référence croisée

S8VK-Txxx24-400 (PCB conformal coating for dusty/humid/corrosive environments)

  1. Contact Phénix: QUINT4 series Coated version (coating option via suffix)
  2. Meanwell TDR: Custom conformal coating available (standard TDR uncoated, custom order required)
  3. Siemens: SITOP PSU coated version
  4. Domestique: RDW series with three-proof coating

Redundancy Module Cross Reference (S8VK-R10 / S8VK-R20)

OMRON Redundancy ModulePhoenix RedundancyMeanwell RedundancySiemens Redundancy
S8VK-R10 (10UN)QUINT-DIODE/12-24DC/10DR-RDN206EP1961-3BA01
S8VK-R20 (20UN)QUINT-DIODE/12-24DC/20DR-RDN206EP1961-3BA21

Key Difference Notes (Selection Focus)

  1. BOOST Peak Capacity

S8VK-T fixed 120% Power Boost for all models; Phoenix QUINT4 has stronger dynamic BOOST for short-time peak loads; Meanwell TDR uses conventional constant current limiting.

  1. Caractéristiques d'entrée

OMRON S8VK-T supports two-phase input. Some competitors’ three-phase power supplies do not support two-phase single-side power supply, verify carefully for retrofit projects.

  1. Dimension & Installation

OMRON S8VK-T is compact narrow-width design; Phoenix TRIO and Siemens SITOP models of same power are generally wider. DIN rail mounting space is the most common bottleneck for direct replacement.

  1. Protection Logic Difference

S8VK-T overvoltage protection is output latch-off, reset by power cycle. Some competitors adopt hiccup auto-recovery, which may affect control system logic.

  1. Plage de température

OMRON S8VK-T features -40℃ cold start advantage; some Taiwan and domestic brands have lower limit of -30℃, use caution for cold-region equipment.

Selection Recommendation Strategy

Équipement d'exportation, haute fiabilité, cold environment: Prefer Phoenix QUINT4 / Siemens SITOP

Priorité aux coûts, ordinary domestic automation equipment: Meanwell TDR series

Budget control for domestic projects: Domestic RDW three-phase DIN rail power supply

Précédent:

Laisser une réponse

Laisser un message