Statut: EOL Discontinued (since 2017); Remplacement direct: G3PA-220B-VD-X
Taper: Single-hase SSR, integrated heat sink, zero-cross triggering, opto-coupler isolation; the mainstream model for temperature control & charges de chauffage
✅ Model Number Breakdown
G3PA: G3PA series power solid state relay
220: 20Une note, AC24~240V
B: Built-in heat sink
VD: DC control input (DC5~24V)
📌 Spécifications électriques de base
Saisir (Control Side)
Tension d'entrée nominale: DC 5~24V
Plage de tension de fonctionnement: DC 4~30V
Courant d'entrée: ≤7mA @ 25℃
Must-operate voltage: ≤DC4V
Must-release voltage: ≥DC1V
Polarité: CC positif & negative, no reverse connection allowed
Isolement: Opto-triac isolation; dielectric strength AC4000V / 1min (input ↔ output)
Sortir (Côté charge)
Load voltage: AC24 ~ 240 V (50/60Hz)
Plage de tension de fonctionnement: AC19~264V
Rated load current: 0.1~20A @ 40℃ (derating required above 40℃ ambient temperature)
Non-repetitive surge current: 220UN (60Hz, 1 faire du vélo)
Repetitive peak off-state voltage VDRM: 600V
On-state voltage drop: ≤1.8V RMS
Courant de fuite: ≤5mA@AC100V; ≤10mA@AC200V
Trigger mode: Zero-cross turn-on
Operate / release time: ≤½ AC cycle +1ms
I²t rating: 260 A²·s
🧱 Environmental & Données mécaniques
Température de fonctionnement: -30℃ ~ +80℃ (pas de condensation)
Température de stockage: -30℃ ~ +100℃ (pas de givrage ni de condensation)
Humidité: 45~85% RH
Montage: DIN rail mounting or M4 screw fixing
Poids: environ. 340g
Certifications: UL508, cUL, EN60950-1
🛠️ Applications typiques
- Température & Heating Control (Utilisation principale)
- Plastic machinery: Barrel heater bands for injection moulding machines, extrudeuses, PET blow moulders with PID cycle control via temperature controllers
- Food processing equipment: Fours industriels, drying lines, thermoscelleuses, fourneaux, constant-temperature water/oil baths
- Machines d'emballage: Heat sealers, hot foil stamping machines, thermoforming equipment
Avantage: Zero-cross switching suppresses current surges and extends heater life; directly driven by PLC or temperature controller outputs
- CVC & Équipement environnemental
Duct electric heaters, dehumidifier heating modules, auxiliary heating for thermostatic air conditioners, thermal cycling test chambers
Petits ventilateurs & pompes à eau de circulation (résistif / lightly inductive loads; NOT suitable for direct start-up of heavy-duty motors)
- Automation Production & Packaging Lines
AC solenoid valves, thermo-pneumatic actuators, small 220V transformers, indicator light banks
Conveyor auxiliary heating, labeler heating modules
Fonctionnalité: Non-contact switching with no arcing; preferred for control cabinets with dust and low explosion risk
- Éclairage & Automatisation des bâtiments (Resistive Lamp Loads)
Industrial lighting circuits, lamp ageing racks, infrared heating lamps (incandescent lamps only)
⚠️ Remarque: DIRIGÉ & fluorescent lamps suffer leakage current causing faint glow; install bleeder resistors in parallel.
- Burn-in & Équipement d'essai
Power ageing racks, load test benches, component high-temperature ageing boards with independent on/off control for multi-channel AC loads
Low-noise power switching for laboratory instruments without spark interference
✅ Application Limits & Notes de sélection
Recommended loads: Resistive heating loads first; commutation fréquente (several times per second max); driven by DC24V PLC outputs; DIN rail cabinet installation
NOT suitable for: High-frequency PWM voltage regulation, direct starting of large motors, heavy inductive loads (large inductors, bobines de contacteur), charges capacitives
Remarque importante: Ce modèle est abandonné; new projects adopt G3PA-220B-VD-X, fully pin-to-pin and electrically compatible for direct replacement
⚠️ Guide de dépannage
- Output permanently ON: Thyristor breakdown caused by short-circuit load surge
- No switching action: Insufficient input voltage, insufficient PLC output current, reversed DC polarity
- Intermittent switching: Overheating due to poor heat dissipation, bornes desserrées, current exceeding derating curve
- Lamp faint glow from leakage current: Add parallel bleeder resistors for lamp loads
🔁 Replacement Options
- Remplacement direct d'origine: G3PA-220B-VD-X (same pinout & specs, current production)
- Higher current within the same series: PDG du G3PA-240B (40UN), PDG du G3PA-260B (60UN)
- Alternative nationale: Zero-cross SSR 20A/AC240V from Ximaden / Yangming
📎 Terminal Definition (4 terminals total)
+,-: DC control input (polarized)
L, DEHORS : AC load circuit (phase sequence does not matter for zero-cross type)
Liste complète des modèles de OMRON Solid State Relays (RSS)
Explication du suffixe: VD = DC control; VA = AC control; -X = new version replacing discontinued old models; B = integrated heat sink; G3PA is your target series
- G3PA Series-Integrated Heat Sink Single-Phase SSR (Chauffage, Montage sur rail DIN)
Old EOL models: G3PA-210B-VD / G3PA-220B-VD / PDG du G3PA-240B / PDG du G3PA-260B / G3PA-420B-VD
New pin-compatible replacements with suffix -X
G3PA-210B-VD-X|AC24~240V, 10UN, DC5~24V control
G3PA-220B-VD-X|AC24~240V, 20UN, DC5~24V control (direct replacement for G3PA-220B-VD)
PDG du G3PA-240B|AC24~240V, 40UN, DC5~24V control
PDG du G3PA-260B|AC24~240V, 60UN, DC5~24V control
G3PA-420B-VD / -2|AC200~480V, 20UN, DC12 ~ 24 V
G3PA-430B PDG / -2|AC200~480V, 30UN, DC12 ~ 24 V
G3PA-450B-VD-2|AC200~480V, 50UN, DC12 ~ 24 V
Interchangeable power cartridges: G32A-A10/-A20/-A40/-A60/-A420
- G3PE Series-Compact Slim Heat Sink SSR (Célibataire & Three-Phase Heaters)
Monophasé:
G3PE-215B / 225B / 235B / 245B (15/25/35/45UN, AC240V, zero-cross / random options)
Three-phase solid-state contactors:
G3PE-515B / 525B / 535B / 545B (3-phase 380V heating loads)
- G3PJ Series-Low Heat SSR for Dense Cabinet Installation
G3PJ-225B-VD, G3PJ-225B-VD-PU (Bornes à ressort enfichables), 25A single-phase
- G3PF Series-Intelligent SSR with Built-in CT (Brûlure du chauffage & SSR Short-Circuit Detection)
Monophasé: G3PF-225B / 235B / 245B
Triphasé: G3PF-525B / 535B / 545B
- G3PC Series-Fault Detection SSR with Alarm Output
For safety monitoring in temperature control loops with fault signal output
- G3PH Series-High-Current High-Power SSR
G3PH-275B: AC240V, 75UN
G3PH-475B / 4150B: AC480V, 75UN / 150UN
- G3NA Series-Puck-Style SSR (No Built-in Heat Sink; External Heat Sink Required)
5~90A bare power core, cost-effective with separate heat sink
G3NA-205B, 210B, 220B, 240B, 260B, 420B, 440B, 460B, 490B
- G3NE Series-Low-Cost Compact SSR (Built-in Equipment, 5~20A)
G3NE-210T, 220T, 210SL, 220SL; small size for cabinet internal mounting
- G3F / G3FD Series-Plug-in Socket SSR (MY Relay Footprint)
G3F-203SN, G3FD-102SN; DIN socket pluggable, small-power IO & électrovannes
- G3H / G3HD Series-High-Current Plug-in SSR (LY Relay Footprint)
G3H-205B, G3H-210B; pose de prise
- G3R-I/O Series-Isolated Interface SSR (High Insulation for PLC Signal Isolation)
Ultra-thin IO isolation SSR for PLC signal separation
- G3RV Series-6mm Ultra-Slim DIN Rail SSR (G2RV Relay Form Factor)
G3RV-SR, G3RV-ST; high-density control cabinets
- PCB-Mount Miniature SSR (Low Current)
G3MC: Ultra-small PCB SSR, 1UN / 2UN
G3TB: PCB-mounted SSR with status indicator
- G3PW Series-Single-Phase Power Controller (Not Standard SSR; Phase-Angle Regulation)
Thyristor power regulator for continuous voltage adjustment, not simple on/off zero-cross switching
Suffix Code Legend (Guide de sélection rapide)
VD: DC5~24V DC input
Virginie: AC100~240V AC input
B: Dissipateur thermique intégré
-X: New production version replacing discontinued old models
-2: 480V high-voltage variant
Unité centrale: Bornes à ressort enfichables
SL/SN: Input circuit variations
Préfixe 2: AC240V single-phase; Préfixe 4/5: AC400/480V (célibataire / triphasé)
Aide-mémoire de sélection rapide
Standard heating, Rail DIN, 20A → G3PA-220B-VD-X (replaces old G3PA-220B-VD)
Heater burnout monitoring required → G3PF
Three-phase heating → G3PE three-phase / G3PF three-phase
Current above 75A → G3PH
Cost-saving with external heat sink → G3NA
Plug-and-play replacement for mechanical relays → G3F / G3H
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur



















NH42-63-318x560.png)