Relais statique OMRON G3PA-220B-VD - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 Relais statique OMRON G3PA-220B-VD - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

API/

Relais statique OMRON G3PA-220B-VD

Statut: EOL Discontinued (since 2017); Remplacement direct: G3PA-220B-VD-X Type: Single-hase SSR, integrated heat sink, zero-cross triggering, opto-coupler isolation; the mainstream model for temperature control & heating loads ✅ Model Number Breakdown G3PA: G3PA series power solid state relay 220: 20Une note, AC24~240V B: Built-in heat sink VD: DC control input (DC5~24V) 📌 Spécifications électriques de base ...

  • Détails du produit

Statut: EOL Discontinued (since 2017); Remplacement direct: G3PA-220B-VD-X

Taper: Single-hase SSR, integrated heat sink, zero-cross triggering, opto-coupler isolation; the mainstream model for temperature control & charges de chauffage

✅ Model Number Breakdown

G3PA: G3PA series power solid state relay

220: 20Une note, AC24~240V

B: Built-in heat sink

VD: DC control input (DC5~24V)

📌 Spécifications électriques de base

Saisir (Control Side)

Tension d'entrée nominale: DC 5~24V

Plage de tension de fonctionnement: DC 4~30V

Courant d'entrée: ≤7mA @ 25℃

Must-operate voltage: ≤DC4V

Must-release voltage: ≥DC1V

Polarité: CC positif & negative, no reverse connection allowed

Isolement: Opto-triac isolation; dielectric strength AC4000V / 1min (input ↔ output)

Sortir (Côté charge)

Load voltage: AC24 ~ 240 V (50/60Hz)

Plage de tension de fonctionnement: AC19~264V

Rated load current: 0.1~20A @ 40℃ (derating required above 40℃ ambient temperature)

Non-repetitive surge current: 220UN (60Hz, 1 faire du vélo)

Repetitive peak off-state voltage VDRM: 600V

On-state voltage drop: ≤1.8V RMS

Courant de fuite: ≤5mA@AC100V; ≤10mA@AC200V

Trigger mode: Zero-cross turn-on

Operate / release time: ≤½ AC cycle +1ms

I²t rating: 260 A²·s

🧱 Environmental & Données mécaniques

Température de fonctionnement: -30℃ ~ +80℃ (pas de condensation)

Température de stockage: -30℃ ~ +100℃ (pas de givrage ni de condensation)

Humidité: 45~85% RH

Montage: DIN rail mounting or M4 screw fixing

Poids: environ. 340g

Certifications: UL508, cUL, EN60950-1

🛠️ Applications typiques

  1. Température & Heating Control (Utilisation principale)
  2. Plastic machinery: Barrel heater bands for injection moulding machines, extrudeuses, PET blow moulders with PID cycle control via temperature controllers
  3. Food processing equipment: Fours industriels, drying lines, thermoscelleuses, fourneaux, constant-temperature water/oil baths
  4. Machines d'emballage: Heat sealers, hot foil stamping machines, thermoforming equipment

Avantage: Zero-cross switching suppresses current surges and extends heater life; directly driven by PLC or temperature controller outputs

  1. CVC & Équipement environnemental

Duct electric heaters, dehumidifier heating modules, auxiliary heating for thermostatic air conditioners, thermal cycling test chambers

Petits ventilateurs & pompes à eau de circulation (résistif / lightly inductive loads; NOT suitable for direct start-up of heavy-duty motors)

  1. Automation Production & Packaging Lines

AC solenoid valves, thermo-pneumatic actuators, small 220V transformers, indicator light banks

Conveyor auxiliary heating, labeler heating modules

Fonctionnalité: Non-contact switching with no arcing; preferred for control cabinets with dust and low explosion risk

  1. Éclairage & Automatisation des bâtiments (Resistive Lamp Loads)

Industrial lighting circuits, lamp ageing racks, infrared heating lamps (incandescent lamps only)

⚠️ Remarque: DIRIGÉ & fluorescent lamps suffer leakage current causing faint glow; install bleeder resistors in parallel.

  1. Burn-in & Équipement d'essai

Power ageing racks, load test benches, component high-temperature ageing boards with independent on/off control for multi-channel AC loads

Low-noise power switching for laboratory instruments without spark interference

✅ Application Limits & Notes de sélection

Recommended loads: Resistive heating loads first; commutation fréquente (several times per second max); driven by DC24V PLC outputs; DIN rail cabinet installation

NOT suitable for: High-frequency PWM voltage regulation, direct starting of large motors, heavy inductive loads (large inductors, bobines de contacteur), charges capacitives

Remarque importante: Ce modèle est abandonné; new projects adopt G3PA-220B-VD-X, fully pin-to-pin and electrically compatible for direct replacement

⚠️ Guide de dépannage

  1. Output permanently ON: Thyristor breakdown caused by short-circuit load surge
  2. No switching action: Insufficient input voltage, insufficient PLC output current, reversed DC polarity
  3. Intermittent switching: Overheating due to poor heat dissipation, bornes desserrées, current exceeding derating curve
  4. Lamp faint glow from leakage current: Add parallel bleeder resistors for lamp loads

🔁 Replacement Options

  1. Remplacement direct d'origine: G3PA-220B-VD-X (same pinout & specs, current production)
  2. Higher current within the same series: PDG du G3PA-240B (40UN), PDG du G3PA-260B (60UN)
  3. Alternative nationale: Zero-cross SSR 20A/AC240V from Ximaden / Yangming

📎 Terminal Definition (4 terminals total)

+,-: DC control input (polarized)

L, DEHORS : AC load circuit (phase sequence does not matter for zero-cross type)

Liste complète des modèles de OMRON Solid State Relays (RSS)

Explication du suffixe: VD = DC control; VA = AC control; -X = new version replacing discontinued old models; B = integrated heat sink; G3PA is your target series

  1. G3PA Series-Integrated Heat Sink Single-Phase SSR (Chauffage, Montage sur rail DIN)

Old EOL models: G3PA-210B-VD / G3PA-220B-VD / PDG du G3PA-240B / PDG du G3PA-260B / G3PA-420B-VD

New pin-compatible replacements with suffix -X

G3PA-210B-VD-X|AC24~240V, 10UN, DC5~24V control

G3PA-220B-VD-X|AC24~240V, 20UN, DC5~24V control (direct replacement for G3PA-220B-VD)

PDG du G3PA-240B|AC24~240V, 40UN, DC5~24V control

PDG du G3PA-260B|AC24~240V, 60UN, DC5~24V control

G3PA-420B-VD / -2|AC200~480V, 20UN, DC12 ~ 24 V

G3PA-430B PDG / -2|AC200~480V, 30UN, DC12 ~ 24 V

G3PA-450B-VD-2|AC200~480V, 50UN, DC12 ~ 24 V

Interchangeable power cartridges: G32A-A10/-A20/-A40/-A60/-A420

  1. G3PE Series-Compact Slim Heat Sink SSR (Célibataire & Three-Phase Heaters)

Monophasé:

G3PE-215B / 225B / 235B / 245B (15/25/35/45UN, AC240V, zero-cross / random options)

Three-phase solid-state contactors:

G3PE-515B / 525B / 535B / 545B (3-phase 380V heating loads)

  1. G3PJ Series-Low Heat SSR for Dense Cabinet Installation

G3PJ-225B-VD, G3PJ-225B-VD-PU (Bornes à ressort enfichables), 25A single-phase

  1. G3PF Series-Intelligent SSR with Built-in CT (Brûlure du chauffage & SSR Short-Circuit Detection)

Monophasé: G3PF-225B / 235B / 245B

Triphasé: G3PF-525B / 535B / 545B

  1. G3PC Series-Fault Detection SSR with Alarm Output

For safety monitoring in temperature control loops with fault signal output

  1. G3PH Series-High-Current High-Power SSR

G3PH-275B: AC240V, 75UN

G3PH-475B / 4150B: AC480V, 75UN / 150UN

  1. G3NA Series-Puck-Style SSR (No Built-in Heat Sink; External Heat Sink Required)

5~90A bare power core, cost-effective with separate heat sink

G3NA-205B, 210B, 220B, 240B, 260B, 420B, 440B, 460B, 490B

  1. G3NE Series-Low-Cost Compact SSR (Built-in Equipment, 5~20A)

G3NE-210T, 220T, 210SL, 220SL; small size for cabinet internal mounting

  1. G3F / G3FD Series-Plug-in Socket SSR (MY Relay Footprint)

G3F-203SN, G3FD-102SN; DIN socket pluggable, small-power IO & électrovannes

  1. G3H / G3HD Series-High-Current Plug-in SSR (LY Relay Footprint)

G3H-205B, G3H-210B; pose de prise

  1. G3R-I/O Series-Isolated Interface SSR (High Insulation for PLC Signal Isolation)

Ultra-thin IO isolation SSR for PLC signal separation

  1. G3RV Series-6mm Ultra-Slim DIN Rail SSR (G2RV Relay Form Factor)

G3RV-SR, G3RV-ST; high-density control cabinets

  1. PCB-Mount Miniature SSR (Low Current)

G3MC: Ultra-small PCB SSR, 1UN / 2UN

G3TB: PCB-mounted SSR with status indicator

  1. G3PW Series-Single-Phase Power Controller (Not Standard SSR; Phase-Angle Regulation)

Thyristor power regulator for continuous voltage adjustment, not simple on/off zero-cross switching

Suffix Code Legend (Guide de sélection rapide)

VD: DC5~24V DC input

Virginie: AC100~240V AC input

B: Dissipateur thermique intégré

-X: New production version replacing discontinued old models

-2: 480V high-voltage variant

Unité centrale: Bornes à ressort enfichables

SL/SN: Input circuit variations

Préfixe 2: AC240V single-phase; Préfixe 4/5: AC400/480V (célibataire / triphasé)

Aide-mémoire de sélection rapide

Standard heating, Rail DIN, 20A → G3PA-220B-VD-X (replaces old G3PA-220B-VD)

Heater burnout monitoring required → G3PF

Three-phase heating → G3PE three-phase / G3PF three-phase

Current above 75A → G3PH

Cost-saving with external heat sink → G3NA

Plug-and-play replacement for mechanical relays → G3F / G3H

Précédent:

Laisser une réponse

Laisser un message