Pilz 773400-PNOZ-MI1P Safety Input Expansion Module

Pilz 773400-PNOZ-MI1P Safety Input Expansion Module The Pilz 773400-PNOZ-MI1P is an 8-channel 24VDC safety digital input expansion module belonging to the PNOZmulti Classic product range. It provides I/O expansion for the PNOZmulti safety control system and supports safety functions such as emergency stop, safety gate monitoring and two-hand control. Complying with PLd per EN ISO ...

  • Détails du produit

Pilz 773400-PNOZ-MI1P Safety Input Module d'extension

Le Champignon 773400-PNOZ-MI1P is an 8-channel 24VDC safety digital input expansion module belonging to the PNOZmulti Classic product range. It provides I/O expansion for the PNOZmulti safety control system and supports safety functions such as emergency stop, safety gate monitoring and two-hand control. Complying with PLd per EN ISO 13849-1 and SIL CL 2 per EN/IEC 62061, it is designed for industrial automation applications requiring high-safety-level signal acquisition. Ce produit a été abandonné, and corresponding modules from the PNOZmulti 2 series are recommended as replacements.

  1. Définition du code modèle
Segment de codeDéfinitionDescription détaillée
773400Code de commandeUnique official Pilz part number for ordering and inventory management
PNOZSeries PrefixCore identifier for Pilz safety relay and safety control product line
MIType de moduleSafety Digital Input Module (M-Series Input), differentiated from MO (Sortir) and MC (Mixed I/O)
1Channel SpecStandard 8-input variant (1 = 8 chaînes, 2 = 16 chaînes)
P.Version CodePNOZmulti Classic edition, distinguished from Series 2 (new-generation PNOZmulti 2)

Note: This is an expansion module for PNOZmulti Classic and must be used together with compatible base units (par exemple. PNOZ m1p); standalone operation is not supported.

  1. Spécifications techniques de base
CatégorieSpécificationRemarques
Caractéristiques de base
Channel Count8 safety digital input channelsConfigurable for single-channel or dual-channel safety circuit logic
Type d'entrée24VDC discrete inputConforme à la norme EN 61131-2 Taper 1; compatible with PNP / NPN sensors
Input PolarityPositive/Negative Logic configurableParameterized via PNOZmulti Configurator software
Courant d'entréeEnviron. 5mA per channelLow-power design to reduce load on field sensors
Paramètres électriques
Tension de fonctionnement20.4~28,8 VCC (nominal 24VDC)Powered from base unit via internal backplane bus
Input Signal LevelOFF-state: -3~+5VDC; ON-state:19.2~30VDCWide voltage tolerance against field supply fluctuation
Test Pulse FunctionBuilt-in test pulse outputDetects short-circuit across input contacts to elevate safety integrity
Isolation RatingNo inter-channel isolation; isolation between module and backplaneDielectric withstand: 250Vrms
Temps de réponse≤10ms (factory default setup)Fast safety reaction for emergency stop and safety interlock
Certifications de sécurité
Safety RatingEN ISO 13849-1 PLd; EN/IEC 62061 SIL CL 2For medium-risk machinery safety applications
Approved CertificatesCE, UKCA, cULus, KOSHA, CAE (TÜV certified)Meets global mainstream market safety compliance
Données environnementales
Température de fonctionnement.0℃ ~ 60℃Standard industrial ambient range
Température de stockage.-25℃ ~ 70℃Tolerates harsh transportation & storage conditions
Humidité relative93%RH @40℃, sans condensationExtended humidity resistance
Protection contre la pénétrationIP20For cabinet indoor installation only
Mécanique & Montage
Dimensions94(H)×22.5(W)×121(D) MMStandard DIN rail footprint
Poids~120g (without terminals), ~138g (avec bornes)Lightweight to minimize DIN rail load
MontageHorizontal installation on 35×7.5mm EN 50022 standard DIN railConvenient system expansion and integration
Type de borneOptional spring-cage plug-in terminals / bornes à visFast field wiring and maintenance

III. Full Product Lineup (PNOZmulti Classic Input Expansion Modules)

ModèleChannel QtyInput SpecCaractéristique spécialeNuméro de commande.Statut du cycle de vie
PNOZ MI1P824VDC Safety DIStandard non-coated version773400Discontinué
PNOZ MI1P C824VDC Safety DIConformal coated for harsh ambient773405Discontinué
PNOZ MI2P1624VDC Safety DI16-channel extended model773410Discontinué
PNOZ MI2P C1624VDC Safety DI16-channel coated variant773415Discontinué
PNOZ MI4P424VDC Safety DICompact 4-channel type773420Discontinué
  1. Remplacement & Comparaison entre marques
  2. Internal Pilz Alternatives
Original PNReplacement PNRaison du remplacementRemarque sur la compatibilité
773400-PNOZ-MI1P774700-PNOZ m2p mi1pNew upgrade to PNOZmulti 2 platformRequires PNOZmulti 2 base unit + full program reconfiguration
773400-PNOZ-MI1P774705-PNOZ m2p mi1p CCoated version for corrosive environmentRequires PNOZmulti 2 base unit + full program reconfiguration
773400-PNOZ-MI1P773405-PNOZ MI1P CConformal coating addedDrop-in compatible with original PNOZmulti Classic base unit
  1. Competitor Cross Reference
Pilz PartSiemens EquivalentSchneider EquivalentOmron EquivalentDifférences fondamentales
773400-PNOZ-MI1P3RK1304-0CB00-0AA2140SAI73400G9SA-501Champignon: Built-in safety test pulse, PLd/SIL2
Siemens: PROFIsafe fieldbus, PLd/SIL3
Schneider: Quantum safety I/O, PLd/SIL2
Omron: Standalone safety relay, PLc/SIL1
  1. Champs d'application & Cas industriels
  2. Scénarios d'application recommandés

Fabrication automobile

Body Welding Line: Signal collection for E-stop pushbuttons, safety gate limit switches and two-hand control devices

Final Assembly Line: Connection for safety light curtains, safety mats and robot perimeter protection signals

Coating Workshop: Interlock input for explosion-proof doors and flammable gas detection alarms

Machine Tool & Usinage

CNC Machine: Safe spindle stop, tool-change safety interlock and workpiece clamping confirmation signals

Press & Bending Equipment: Mould safety gate, two-hand start button and slide stroke limit monitoring

Automated Conveying Line: Conveyor safety interlock and personnel access detection

Nourriture & Boisson / Conditionnement

High-speed Packaging Machine: Safety door switches, emergency stop and overload protection signals

Food Processing Line: Wash zone interlock and sterilizer safety gate status monitoring

Filling Equipment: Bottle/can in-position detection and protective door interlock

Logistique & Warehouse Automation

Automated AS/RS: Stacker crane limit switches, E-stop and walk-in access detection

Conveyor System: Line emergency stop, safety gate and overload fault input

Robotic Sorting Line: Robot cell guarding and safety light curtain signal acquisition

  1. Applications non recommandées

Standalone operation: Mandatory pairing with PNOZmulti Classic base unit; cannot run independently

High safety requirement (PL e / SIL3): Select PNOZmulti 2 or higher-grade safety modules instead

Outdoor exposed installation: IP20 rated only for cabinet mounting

AC signal input: Module exclusively for 24VDC; dedicated AC input modules required for AC field signals

  1. Cas d'application typique

Project Title: Safety Retrofit for Automotive Component Stamping Line

Bill of Material: 1×PNOZ m1p base unit + 2×PNOZ MI1P (773400) + 1×PNOZ MO1P output module + PNOZmulti Configurator

Application Benefits:

  1. Monitors 8 safety gate limits, 4 emergency stops and 2 two-hand control signals
  2. Redundant safety circuit design fulfilling EN ISO 13849-1 PLd specification
  3. Onboard test pulse automatically diagnoses input contact short-circuit to improve system reliability
  4. Integrated diagnostics cut unplanned downtime by 40% and enable rapid fault pinpointing for safety loops
  5. Guide de dépannage
Symptôme de panneRoot CauseÉtapes d'inspectionRemedial Action
Module dead, all LEDs off1.Base unit power failure1.Check base unit power LED1.Repair base unit power supply
2.Poor backplane connection2.Unplug and re-seat module2.Fix module locking position
3.Internal hardware damage3.Replace with spare module3.Install replacement module
Partial channels no input1.Erreur de câblage1.Verify wiring against schematic1.Correct field wiring
2.Field sensor defective2.Measure sensor output via multimeter2.Replace faulty sensor
3.Incorrect test pulse setup3.Check test pulse parameter in Configurator3.Config test pulse (only for dry contacts)
4.Burned input channel4.Test with known-good sensor4.Swap to spare channel or replace module
Spurious safety trip1.EMI interference1.Check shielding & mise à la terre1.Reroute cable & add shielding
2.Unstable supply voltage2.Measure input DC 19.2~30V range2.Add power filter for stable supply
3.Loose terminal wiring3.Tighten all screw terminals3.Re-terminate loose wiring
4.Test pulse cross-interference4.Adjust/disable test pulse (for active sensors only)4.Optimize test pulse configuration
Permanent fault LED ON1.Safety circuit fault1.Inspect safety loop wiring1.Remediate faulty safety wiring
2.Backplane communication loss2.Check inter-module bus connection2.Restore bus connection
3.Invalid project configuration3.Download corrected configuration3.Re-program and download project

VII. Lignes directrices de sélection & Référence rapide

Mnémonique de sélection

Eight-channel safety DI MI1P, 24VDC PNOZ expansion piece;

PLd safety grade, test pulse stops short-circuit disease;

Auto, machine, packaging cabinet-mounted IP20 lease;

Classic discontinued, upgrade to m2p series.

Règles rapides

  1. Model Decoding:773400 = PNOZ MI1P; PNOZ=Safety Series; MI=Input; 1=8CH; P=Classic Version
  2. Core Spec Shortcut:8CH /24VDC /PLd SIL2 /Built-in Test Pulse /IP20 /DIN Rail Mount
  3. Guide de remplacement:Upgrade → PNOZmulti2; Harsh environment → Coated C version; Same platform → Classic coated spare
  4. Application Filter:Safety DI + Medium risk + Cabinet installation = PNOZ MI1P applicable

VIII. Informations de commande & Accessoires

Standard Part No.:773400-PNOZ-MI1P (8-channel safety input module)

Conformal Coated Variant:773405-PNOZ-MI1P C

Recommended Spare Parts:

783400: PNOZmulti Spring Terminal Kit (fits MI1P/MI2P/MO1P)

793400: PNOZmulti Screw Terminal Kit (fits MI1P/MI2P/MO1P)

779110: PNOZmulti Bus Terminator (mandatory for multi-module expansion setup)