Schneider LC1F1250MD Contactor

Definition of each part of LC1F1250MD: Segment Description LC Product category code, stands for Schneider Contactor product line 1 Standard single contactor (2 = reversing contactor) F Series code, stands for TeSys F Series (heavy-duty industrial contactor) 1250 Rated current specification: 1250UN (actual 1260A under AC-1 @ 440V) M Coil voltage code: 220V (AC or DC distinguished by the ...

  • Détails du produit

Definition of each part of LC1F1250MD:

SegmentDescription
LCProduct category code, stands for Contacteur Schneider product line
1Standard single contactor (2 = reversing contactor)
FCode de série, stands for TeSys F Series (heavy-duty industrial contactor)
1250Rated current specification: 1250UN (actual 1260A under AC-1 @ 440V)
M.Code de tension de bobine: 220V (AC or DC distinguished by the following letter)
DCoil type code: Bobine CC (M7 = AC coil; MD = DC coil)

Core Difference:

LC1F1250MD is fitted with 220VDC coil, while LC1F1250M7 is 220VAC coil. Both share identical main circuit parameters; only the control circuit power supply type differs.

  1. Spécifications techniques de base
CatégorieParamètres
Basic Characteristics• Product Series: TeSys F heavy-duty industrial contactor
• Poles: 3P. (3 poteaux)
• Main Contacts: 3NON (3 Normalement ouvert)
• Utilization Category: AC-1 (non-inductive / slightly inductive loads such as resistance furnaces)
• Montage: Rail DIN standard de 35 mm / bolt mounting
Main Circuit Ratings• Rated Operational Voltage (Ue): ≤690 V CA (50/60Hz) / ≤460V DC
• Rated Insulation Voltage (Interface utilisateur): 1000V et
• Rated Operational Current (C'est à dire): 1260UN (AC-1, 440V, 40°C)
• Conventional Thermal Current (je): 1260UN
• Short-time Withstand Current (Icw): 25le / 1s @ 400V
• Contact Resistance: ≤0.12mΩ
Control Circuit Ratings• Coil Type: Bobine CC
• Rated Coil Voltage (Uc): 220VCC (compatible with 230VDC in practice)
• Coil Power Consumption: Pull-in 140W, Holding 24W
• Pull-in Time: ≤80ms
• Drop-out Time: ≤50ms
• Control Terminals: Screw clamp type
Mécanique & Environnemental• Mechanical Life: 1,000,000 opérations
• Electrical Life (AC-1): 100,000 opérations
• Max Operating Frequency: 300 cycles/hour
• Operating Temperature: -5~+40°C (derating required +40~+60°C)
• Storage Temperature: -25~+60°C
• Protection Class: IP20 (after installation)
• Dimensions (L×H×P): 309×280×181mm
• Weight: Environ. 18kilos
Certifications & Normes• Compliance: CEI 60947-4-1, DANS 60947-4-1, FR 14048.4
• Approvals: CE, UL, ASC, CCC, UKCA
• Eco Certification: Green Premium (RoHS / REACh compliant)
  1. Accessory List

3.1 Accessoires standards

Contactor main unit LC1F1250MD ×1

Mounting fasteners (DIN rail clip / bolts) ×1

Operation Manual (electronic version) ×1

Coil surge suppressor (facultatif, separate order required)

3.2 Accessoires en option (Sold Separately)

Type d'accessoireExemple de modèleBut
Auxiliary Contact BlockLAD9F01 / LAD9F10Add 1NO / 1NC auxiliary contacts for control circuit expansion
Mechanical Interlock BlockLA9FF976For reversing circuit (forward/reverse), prevents simultaneous closing of two contactors
Terminal Protection CoverLAD9V6Safety protection for main circuit terminals, prévention des chocs électriques
Power Connection BusbarLAD9B1250High-current main circuit wiring, simplifies installation
Surge SuppressorLAD9R220Protect coil, suppress reverse EMF when DC coil is de-energized
Auxiliary Contact BaseLAD9FMount multiple auxiliary modules; expandable up to 6 auxiliary contacts maximum
  1. Competitor & Cross-Brand Equivalent
MarqueModèleCourant nominalTension de bobinePoteaux / ContactsNiveau de prixMain Advantages
SchneiderLC1F1250MD1250UN220VCC3P. / 3NONHautHeavy-duty design, drawer-type coil, entretien facile
Schneider AlternativeLC1G1250MD1250UN220VCC3P. / 3NONMi-hautTeSys Giga series, upgraded replacement for LC1F
Siemens3TF5544-0XM01250UN220VCC3P. / 3NONHautFull series compatibility, seamless S7 PLC connection
ABBA1450-30-111250UN220VCC3P. / 3NONHautConception modulaire, flexible auxiliary contact expansion
MitsubishiS-N12501250UN220VCC3P. / 3NONMi-hautJapanese quality, cost-performance
EatonDILM1250(220VCC)1250UN220VCC3P. / 3NONMilieuStructure compacte, saves cabinet space
  1. Lignes directrices de sélection & Solutions de remplacement

5.1 Core Selection Rules

Type de charge: AC-1 (resistance furnace, chauffage) → suitable for LC1F1250MD; AC-3 (moteur) → operate with derating or select dedicated AC-3 contactor

Control Supply: 220VDC → choose MD suffix; 220VAC → choose M7 suffix; refer to Schneider coil code table for other voltages

Espace d'installation: Width 309mm, reserve sufficient cabinet space; for compact layout adopt LC1G series (smaller dimension)

Contacts auxiliaires: No built-in auxiliary contacts by default; order LAD9 series auxiliary modules separately

Commodité d'entretien: Drawer-type coil structure; coil replacement without disconnecting main circuit wiring, ideal for frequent maintenance scenarios

5.2 Recommended Replacement Models

Scénario d'applicationModèle recommandéReason
Upgrade existing LC1FLC1G1250MDTeSys Giga upgraded series, performances supérieures, more compact size, entièrement interchangeable
AC control power supplyLC1F1250M7Same main circuit parameters, 220VAC coil for AC control system
Contrôle du moteur (AC-3)LC1F1250MD (derated to 800A)Heavy-duty design, usable for AC-3 after derating; alternatively use LC1F1400
Compact cabinet installationABB A1450-30-11Width 280mm, saves 29mm compared with LC1F1250MD
Budget limitedMitsubishi S-N1250Japanese brand, 15-20% lower price than European brands with reliable performance
DC supply & opération fréquenteLC1F1250MD + LAD9R220Surge suppressor protects coil and extends service life

5.3 Key Technical Advantages

  1. Heavy-duty Construction: 1260Un courant nominal, 25kA short-time withstand capability, suitable for large industrial loads
  2. Drawer-type Coil: Independent coil module; replaceable without removing main circuit wiring, maintenance efficiency improved by 50%
  3. Wide Voltage Compatibility: Main circuit up to 690V AC / 460À DC, adaptable to various industrial power systems
  4. Global Approvals: Full CE/UL/CSA/CCC/UKCA certification for worldwide project deployment
  5. Eco Compliance: Green Premium certified, meets RoHS/REACh environmental standards for sustainable application

Schneider LC1F1250MD is a TeSys F Series 3-pole 1250A heavy-duty industrial contactor. Its core strengths are drawer-type DC coil design and high short-circuit withstand capability, perfectly suited for AC-1 non-inductive / slightly inductive loads such as resistance furnaces and heating equipment.

Lors de la sélection, focus on control supply type (220VCC), load category (AC-1 optimal), and installation space. For upgrade or replacement, prefer the new-generation TeSys Giga LC1G1250MD, or select LC1F1250M7 (220ACC) according to control power type.

Complete Model List of Schneider TeSys F (LC1F) Contacteurs (Latest 2026 Version)

Classified by model naming rule, current rating, coil code, full model list and selection guide. Covers all LC1F specifications including 3-pole / 4-pôle, CA / Bobine CC, standard / wide voltage versions for heavy-duty industrial control.

  1. LC1F Model Naming Rule

Format: LC1F[Note actuelle][Code de bobine][Special Function]

SegmentDescriptionPossibilités & Explication
LCProduct CategoryContactor product line
1Contactor Type1 = Standard single contactor; 2 = Reversing contactor (forward/reverse)
FCode de sérieTeSys F Series heavy-duty type, 115A~2100A
[Note actuelle]Courant nominal115/150/185/225/265/330/400/500/630/780/1000/1250/1400/1700/2100
[Code de bobine]Tension de bobine & TaperFirst letter = voltage level; last letter = coil type (7=AC, D=DC)
[Special Function]Optional FeatureS411 = Wide voltage coil (100-250V CA/CC); Blank = Standard version

Exemple:

LC1F1250MD → 1250A, 220Bobine VCC

LC1F265M7 → 265A, 220VAC coil

  1. Coil Voltage Code Table (General for Whole Series)
Code de bobineTensionType de bobineApplication
B6/B724VCA (50/60Hz)Safety control circuit, PLC output
C6/C736VCALow-voltage safety location
E6/E748VCAIndustrial control, small equipment
F6/F7110VCANorth America / Japan standard control system
M6/M7220VCAChine / Asia standard general control
P6/P7230VCAEuropean standard general control
Q6/Q7380VCAIndustrial high-voltage control, large equipment
R6/R7400VCAEuropean industrial 3-phase standard
S6/S7415VCACommonwealth national standard
U6/U7440VCANorth American industrial standard
BD24VCCContrôle CC, PLC output
CD36VCCDC low-voltage control
ED48VCCDC industrial control
FD110VCCDC control system
MD220VCCGeneral DC control (most widely used)
PD230VCCEuropean DC standard
QD380VCCDC high-voltage control
S411100-250VAC/DC UniversalWide voltage for global projects
  1. LC1F Full Current Ratings & Base Models

3P Standard Type (3P/3NO) for AC-1 resistive load and AC-3 motor load:

Base ModelRated Current AC-1@440V,40°CAC-3 Current@400VMatched Motor Power@400V AC-3Largeur (mm)
LC1F115115UN115UN55kW100
LC1F150150UN150UN75kW100
LC1F185185UN185UN90kW125
LC1F225225UN225UN110kW140
LC1F265265UN265UN132kW160
LC1F330330UN330UN160kW180
LC1F400400UN400UN200kW200
LC1F500500UN500UN250kW220
LC1F630630UN630UN315kW250
LC1F780780UN780UN375kW280
LC1F10001000UN1000UN450kW300
LC1F12501260UN1250UN560kW309
LC1F14001400UN1400UN630kW320
LC1F17001700UN1700UN750kW340
LC1F21002100UN2100UN900kW360

4P Extended Type (4P/4NO): Model suffix with 4 (LC1F1154 ~ LC1F21004). Rated current same as 3P version, suitable for 4-wire systems.

  1. Complete LC1F Model List by Current

4.1 115A~265A Medium Power

Modèle completActuelCoil SpecPoteaux
LC1F115B6115UN24V et3P.
LC1F115B7115UN24V et3P.
LC1F115BD115UN24À DC3P.
LC1F115M7115UN220V et3P.
LC1F115MD115UN220À DC3P.
LC1F150M7150UN220V et3P.
LC1F150MD150UN220À DC3P.
LC1F185M7185UN220V et3P.
LC1F185MD185UN220À DC3P.
LC1F225M7225UN220V et3P.
LC1F225MD225UN220À DC3P.
LC1F265M7265UN220V et3P.
LC1F265MD265UN220À DC3P.
LC1F265S411265UN100-250V CA/CC3P.

4.2 330A~780A High Power

Modèle completActuelCoil SpecPoteaux
LC1F330M7330UN220V et3P.
LC1F330MD330UN220À DC3P.
LC1F400M7400UN220V et3P.
LC1F400MD400UN220À DC3P.
LC1F500M7500UN220V et3P.
LC1F500MD500UN220À DC3P.
LC1F630M7630UN220V et3P.
LC1F630MD630UN220À DC3P.
LC1F780M7780UN220V et3P.
LC1F780MD780UN220À DC3P.

4.3 1000A~2100A Super High Power

Modèle completActuelCoil SpecPoteauxRemarques
LC1F1000M71000UN220V et3P.
LC1F1000MD1000UN220À DC3P.
LC1F1250M71250UN220V et3P.Popular model
LC1F1250MD1250UN220À DC3P.Popular model
LC1F1400M71400UN220V et3P.Drawer coil type
LC1F1400MD1400UN220À DC3P.Drawer coil type
LC1F1700M71700UN220V et3P.Drawer coil type
LC1F1700MD1700UN220À DC3P.Drawer coil type
LC1F2100M72100UN220V et3P.Drawer coil type
LC1F2100MD2100UN220À DC3P.Drawer coil type
LC1F2100S411P72100UN100-250V et3P.Wide voltage version

4.4 4-Pole Series (Suffix with 4)

Modèle completActuelCoil SpecPoteauxApplication
LC1F1154M7115UN220V et4P.4-système de fil
LC1F1854MD185UN220À DC4P.3-phase 4 fils
LC1F2654M7265UN220V et4P.Load with neutral line
LC1F4004MD400UN220À DC4P.4-pole protection system
  1. Reversing Contactor Models (LC2F Series)

LC2F = Reversing type for motor forward/reverse control with mechanical interlock to prevent simultaneous closing:

Modèle completActuelCoil SpecPoteauxInterlock Type
LC2F115M7115UN220V et3P+3PMechanical interlock
LC2F185MD185UN220À DC3P+3PMechanical interlock
LC2F265M7265UN220V et3P+3PMechanical interlock
LC2F400MD400UN220À DC3P+3PMechanical interlock
  1. Remplacement du modèle & Upgrade Guide
  2. LC1F Upgrade: Replace LC1F with LC1G (TeSys Giga); more compact size, 30% performance improvement, fully interchangeable mounting and wiring.
  3. Coil Replacement: Same current rating different coils are interchangeable (par exemple. LC1F1250M7 ↔ LC1F1250MD, only coil module replaced).
  4. Load Application:

AC-1 resistive load: Use 100% courant nominal

AC-3 motor load: Use 100% courant nominal (LC1F designed for heavy duty)

AC-4 frequent starting: Derate by 30%

  1. Wide Voltage Requirement: Select S411 suffix model, compatible with 100-250V AC/DC global control power supply.
  2. Quick Selection Chart
Scénario d'applicationModèle recommandéKey Reason
55kW motor control @400VLC1F115M7Matched power, rentable
110kW motor control @400VLC1F225M7Heavy-duty design, stable operation
560kW resistance furnaceLC1F1250MD1260Un courant nominal, Contrôle CC
Global multi-voltage projectLC1F265S411Wide voltage adaption, no coil replacement needed
DC control systemLC1FxxxMDBobine CC, forte anti-interférence
4-wire distribution systemLC1Fxxx4M74-pole design for neutral circuit
Frequent maintenance siteLC1F1400MD+Drawer-type coil structure, entretien facile