Schneider TM3AI8 Analog Input Expansion Module

Modicon TM3 series 8-channel analog input expansion module, screw terminal version; spring terminal variant: TM3AI8G ✅ Model Definition TM3: Expansion I/O series for M2xx PLCs AI: Entrée analogique 8: 8 channels TM3AI8: Bornes à vis; TM3AI8G: Spring-cage terminals. Paramètres électriques identiques, only terminal construction differs. ✅ Compatible PLC CPUs Modicon M221 / M241 / M251 / ...

  • Détails du produit

Modicon TM3 series 8-channel analog input module d'extension, screw terminal version; spring terminal variant: TM3AI8G

✅ Model Definition

TM3: Expansion I/O series for M2xx PLCs

IA: Entrée analogique

8: 8 chaînes

TM3AI8: Bornes à vis; TM3AI8G: Spring-cage terminals. Paramètres électriques identiques, only terminal construction differs.

✅ Compatible PLC CPUs

Modicon M221 / M241 / M251 / M262. Logiciel de programmation: Expert en machines EcoStruxure (formerly SoMachine)

✅ Key Technical Specifications

ArticleParamètre
Number of channels8 entrées analogiques asymétriques
ADC resolution12-peu (11 peu + sign bit), Σ-Δ sampling
Signal types (configurable per channel)Tension: 0~10 V, -10~+10V
Actuel: 0~20mA, 4~20mA, extended range modes available
Impédance d'entréeVoltage ≥1MΩ; Current ≤50Ω
Overload withstandMax.. 13V for voltage; Max.. 40mA for current
Précision (25℃)±0,2 % pleine échelle, temperature drift ±0.01%FS/℃
Sampling time1ms par canal activé; Temps de conversion total = 1 ms + 1ms par canal + Temps de scrutation de l'automate
AlimentationAlimentation du module DC24V
MontageRail DIN, en cascade via le bus de fond de panier TM3

⚠️ Avertissement critique: Câblage matériel (tension/courant) doit correspondre à la configuration du logiciel. La configuration d'un canal de tension comme mode courant brûlera directement le circuit du module.

✅ Applications typiques

Acquérir des signaux à partir de transmetteurs de pression, transmetteurs de température, capteurs de niveau, débitmètres, cellules de pesée, potentiomètres et autres capteurs. Utilisé dans les machines d'emballage, CVC, lignes de production et petits systèmes de contrôle de processus.

✅ Directives de câblage

  1. Toutes les entrées sont asymétriques; l'entrée différentielle n'est pas prise en charge.
  2. Signal actuel: Câblez la boucle 4-20 mA de l'émetteur directement à AI+ et AI-.
  3. Signal de tension: Connectez la sortie de tension du capteur à AI+ et AI-.
  4. La terre analogique doit être reliée à la terre d'alimentation du PLC pour réduire les interférences. Utilisez un câble blindé pour les longs trajets analogiques avec mise à la terre à une extrémité.

✅ Diagnostics & Codes d'erreur (IBStatus Status Byte)

Status CodeDescription
0Normale, signal within range
5Over-range high (input too high)
6Under-range / rupture de fil (alarm at 0mA under 4-20mA mode, wire break detection)
7Module hardware fault
94~20mA low extended range (1.2~3.99mA)

Note: When 4-20mA channel is open-circuit with no wiring, the module reads the minimum value by default and diagnostic byte = 6. This is normal wire-break detection. Under 0~20mA mode, open circuit reads 0 without this alarm.

✅ Alternative Selection Options

  1. Remplacement de la même série: TM3AI8G (spring terminals for fast field wiring)
  2. Alternatives compatibles nationales: Inovance AM600/AM400 analog input modules, Xinje XL series AI modules
  3. Upgrade for more channels: Select other TM3 AI modules as required. Observe the maximum TM3 expansion limit for M2xx PLCs.

✅ Maintenance & Liste de contrôle d'inspection d'occasion

  1. Contrôle visuel: Backplane bus latches intact, terminal block free of burn marks.
  2. Power-up test: PLC recognizes module, module LED status normal.
  3. Test de canal: Injecter un signal de référence tension/courant, lire les valeurs brutes et vérifier la linéarité.
  4. Micrologiciel: Micrologiciel du module analogique TM3 V29, évolutif dans Machine Expert.
  5. Bus: L'ordre en cascade du module TM3 ne doit pas être modifié. Un mauvais contact du fond de panier déclenche un défaut du bus d'E/S.

✅ Référence du code SH

Module d'extension d'E/S analogiques API, 85371011 (Module d'entrée/sortie de contrôleur programmable). Classement final soumis au courtier en douane et à la décision douanière locale.

✅ Notes de migration du programme

Mise à niveau des anciens modules TM2 AI vers TM3AI8: Le logiciel doit être mis à jour vers SoMachine V4.3 / EcoStruxure Machine Expert V1.0 ou version ultérieure.

Les adresses de mappage de mémoire et de diagnostic de canal diffèrent de celles des modules TM2. Configuration matérielle et acquisition analogique / la logique de rupture de fil doit être reprogrammée.

Configuration des canaux TM3AI8 dans EcoStruxure Machine Expert (formerly SoMachine)

Processeurs compatibles: M221/M241/M251/M262

  1. Ajouter un module sur le bus matériel
  2. Right-click IO_Bus in Device Tree → Add Device, select `TM3AI8` (borne à vis) / `TM3AI8G` (borne à ressort). Confirm module order, TM3 expansion bus sequence must match physical installation order.
  3. After adding, expand TM3AI8 in device tree. 8 analog channels `CH0~CH7` available.
  4. Channel Parameter Configuration (Cœur)
  5. Double-click TM3AI8 in device tree, switch to the I/O Configuration tab. 8 channels can be configured independently.
  6. Channel Type dropdown options (per channel):

Non utilisé: Channel disabled, no acquisition

0~10 V

-10~+10V

0~20mA

4~20mA (standard, wire-break diagnostic supported)

0~20mA extended

4~~20mA extended (detects 1.2~~3.99mA fault range, diagnostic code 9)

⚠️Important: Hardware wiring must match software type! Setting voltage channel to current mode will damage module input circuit.

  1. After configuration, raw acquisition word `%IWi.x` (Raw AD value) and diagnostic byte `%IBs.x` are generated automatically:

%IWi: Raw channel value

%IBs: Channel status byte for wire-break / over-range judgment

  1. Switch to I/O Mapping: Bind `%IWi` and `%IBs` to custom variables for program access.
  2. Raw Value Range Mapping (for engineering conversion)
Channel TypeRaw MinRaw Max
0~10 V04000
-10~+10V-40004000
0~20mA04000
4~20mA400020000

Example for 4-20mA transmitter: 4mA → 4000; 20mA →20000

Engineering formula:

ProcessValue = (RawValue4000) / (200004000) × (UpperRangeLowerRange)

  1. Diagnostic Byte %IBs.x Definition
Diagnostic CodeDescription
0Normale, signal within range
5Over-range high
6Under-range / rupture de fil (typical alarm when 4-20mA wire disconnected)
7Module hardware fault
94~20mA extended mode: 1.2~3.99mA fault range

Note: Under standard 4~20mA mode, open circuit keeps Raw reading fixed at 4000. Wire break cannot be detected only by raw value; %IBs diagnostic byte must be read.

  1. Télécharger & Mise en service
  2. Compile project, verify no hardware configuration errors.
  3. Go online with PLC, open variable watch table to monitor %IW and %IB.
  4. Apply reference voltage/current signal source and verify readings.
  5. Disconnect signal wire to confirm diagnostic byte becomes 6 for 4~20mA channel, wire-break detection works.
  6. Pièges courants
  7. Wrong TM3 module sequence: IO bus fault, PLC fails to identify module.
  8. Mismatch between software type and physical wiring: risk of channel burnout.
  9. Standard 4~20mA mode: relying only on raw value, missing wire-break detection.
  10. Unshielded cable for long analog runs: ground potential difference causes reading fluctuation.

TM3AI8 Analog Input Module Fault Diagnosis Method

General principle: Isolate fault location: capteur / câblage / module / PLC configuration. Do not assume module failure immediately.

Applicable to Schneider TM3AI8 with M221/M241/M251/M262 + Expert en machines EcoStruxure

  1. Étape 1: Module-level Diagnostic (Whole Module Communication Check)
  2. Connect PLC online, check TM3AI8 icon status in device tree

Red cross: PLC cannot communicate with module

Dépannage: Loose expansion bus latch, wrong module installation order, damaged backplane bus, missing DC24V supply, hardware module failure.

Green OK: Module communication healthy. Fault is limited to channel, wiring or configuration.

  1. Read module global status word (module level fault):

Bus fault: Expansion I/O bus error, all channels invalid.

Internal module hardware fault: Module status alarm, abnormal readings for all channels.

  1. Étape 2: Per-channel Diagnosis (%IBs.x channel diagnostic byte, cœur)

Monitor channel diagnostic byte `%IBs.x` in software

Diagnostic CodeDescriptionEmplacement du défaut
0Normale, signal within rangeChannel hardware OK; unstable reading: check sensor/noise/calibration
5Over-range highInput signal exceeds full scale, check transmitter output
6Under-range / rupture de fil (4~20mA)Signal wire broken, transmitter power loss, open loop; Not necessarily module damage
7Channel hardware faultChannel chip damaged on module
94~20mA extended mode: 1.2~3.99mAPanne de l'émetteur, leakage current in loop; not module damage

Point clé: Only diagnostic code 7 indicates hardware damage; code 6 mostly points to external wiring or sensor open circuit.

  1. Étape 3: Signal Injection Test (Cross Test to Separate External / Module Fault)

Équipement d'essai

Adjustable signal source: 0-10V voltage source / 4-20mA current simulator

  1. Channel swap test (le plus courant)

Exemple: CH0 abnormal reading, CH1 normal

Connect signal source to CH0, configure CH0 for matching signal type.

Move same signal source to CH1.

✅ CH1 reads correctly while CH0 remains abnormal: CH0 channel damaged, module faulty.

✅ Both CH0 and CH1 abnormal: Likely signal source, câblage, grounding or configuration issue, module healthy.

  1. Open-circuit test

Voltage mode: Floating channel shows low drifting reading normally.

4~20mA mode: Floating channel triggers diagnostic byte=6 (wire-break alarm), normal module function, not fault.

⚠️ Forbidden: Feed current signal into channel configured as voltage mode; channel will burn out!

  1. Étape 4: Inspection visuelle & Power Supply Check
  2. Module power supply: Measure DC24V at module terminals, valid range 20.4V~28.8V. La basse tension provoque une gigue de lecture et une communication instable.
  3. Inspection visuelle

Terminaux: Marques de brûlure, cuivre fondu, corrosion, entrée d'eau. Un court-circuit aux bornes brûle les canaux.

Bus de fond de panier: Loquet en plastique cassé, contact métallique oxydé ou déformé → échec de communication.

  1. Environnement: Haute température, l'humidité ou de fortes interférences électriques entraînent un saut de lecture analogique, facile à mal juger en cas de panne de module.
  2. Tableau des phénomènes de panne rapide
PhénomèneCause profonde probableModule Fault?
Toutes les chaînes pas de lecture, L'automate signale une perte de communication du module24V alimentation / bus d'extension / séquence de modulesDommages possibles au module
Code de diagnostic monocanal = 7, toujours l'alarme après le changement de source de signalÉpuisement du circuit de canal✅Module défectueux
Code de diagnostic monocanal = 6, autres chaînes normalesÉmetteur hors tension / rupture de fil❌ Défaut externe
La lecture de tous les canaux fluctue continuellement, octet de diagnostic=0Mauvaise mise à la terre / pas de bouclier / interférence du câble d'alimentation❌ Problème de bruit
Valeur brute %IW fixe quel que soit le signal appliquéVerrouillage de canal, dommages matériels✅Module défectueux
Incompatibilité du type de canal logiciel avec le câblage physiqueErreur de configuration, peut brûler la chaîne❌ Erreur de configuration (sauf si la chaîne est déjà brûlée)
  1. Critères de confirmation finale des défauts

✅ Défaillance du module confirmée:

  1. Communication des modules OK, un canal rapporte systématiquement le code de diagnostic = 7.
  2. La valeur brute ne suit pas l'entrée du signal de référence, tandis que les autres canaux du même module fonctionnent normalement.
  3. Marques de brûlure terminales et aucune réponse à l'injection de signal.

❌ Pas de panne de module:

  1. Code de diagnostic 6,5,9. Lecture normale après avoir déplacé le signal vers un autre canal.
  2. La lecture fluctue avec l'octet de diagnostic = 0, récupéré après mise à la terre et amélioration du blindage.
  3. L'automate ne parvient pas à détecter le module, récupéré après réinstallation du bus et correction de l'alimentation électrique.
  4. Supplémentaire: Liste de contrôle d'inspection pour la réception des modules d'occasion
  5. Allumer, L'automate reconnaît le module sans défaut au niveau du module.
  6. Injecter un signal de référence dans chaque canal, read %IW and diagnostic byte.
  7. Verify 4~20mA wire-break alarm function.
  8. All channels have good linearity with no fixed offset.

Schneider Modicon TM3 Full Range Expansion Module List (Compatible with M221/M241/M251/M262)

Suffix explanation: No suffix = screw terminal; G = spring-cage terminal; K = HE10 flat cable connector

  1. Modules analogiques (AI/AQ/Mixed AM, TM3AI8 family)
ModèleChannel DescriptionRemarques
TM3AI44-entrée analogique de canalBorne à vis; TM3AI4G spring terminal
TM3AI88-entrée analogique de canalModel covered above; TM3AI8G spring terminal
TM3AI2H2-channel high precision analog input,16peuVoltage/current support, haute résolution
TM3AQ22-sortie analogique du canalTM3AQ2G spring terminal
TM3AQ44-sortie analogique du canalTM3AQ4G spring terminal
TM3AM64AI+2AO mixed analog moduleTM3AM6G spring terminal
  1. Digital Input Modules DI
ModèleChannel DescriptionRemarques
TM3DI88-point d'entrée numérique DC24VVis; TM3DI8G spring
TM3DI8A8-point AC120V digital inputType CA
TM3DI1616-point d'entrée numérique DC24VVis; TM3DI16G spring
TM3DI32K32-point d'entrée numérique DC24VHE10 socket, câble plat
  1. Digital Output Modules DQ
ModèleChannel DescriptionRemarques
TM3DQ8R8-point relay outputVis; TM3DQ8RG spring
TM3DQ8T8-point PNP transistor DC24V outputVis; TM3DQ8TG spring
TM3DQ16R16-point relay outputVis; TM3DQ16RG spring
TM3DQ16T16-point PNP transistor DC24V outputVis; TM3DQ16TG spring
TM3DQ32TK32-point PNP transistor DC24V outputHE10 socket
  1. Mixed Digital I/O Modules DM (DI+DO)
ModèleChannel DescriptionRemarques
TM3DM8R4DI+4 relay DOVis; TM3DM8RG spring
TM3DM24R16DI+8 relay DOVis; TM3DM24RG spring
  1. High Speed Counter / Modules de fonctions spéciales
ModèleDescription
TM3XHSC202High speed counter module, borne à visEncoder acquisition
TM3XHSC202GHigh speed counter module, borne à ressortEncoder acquisition
TM3XFHSC202High speed counter with event capture, borne à visEvent capture support
TM3XFHSC202GHigh speed counter with event capture, borne à ressortEvent capture support
TM3XTYS4TeSys motor management moduleInterface RJ45, motor protection linkage
  1. Bus Extension Modules (Remote I/O, expand module quantity)
ModèleDescription
TM3XTRA1TM3 bus transmitterCPU side
TM3XREC1TM3 bus receiverRemote cabinet side, max.5m
  1. Bus Coupler (TM3 I/O island, fieldbus slave)
ModèleDescription
TM3BC8CANopen bus coupler, jusqu'à 8 TM3 modules
TM3BC24EtherNet/IP bus coupler, jusqu'à 24 TM3 modules
  1. Safety Module
ModèleDescription
TM3SAC5Safety relay output moduleSafety related applications

Important System Rules

  1. Direct backplane expansion for M221/M241/M251: max.7 TM3 modules. Jusqu'à 14 modules when using TM3XTRA1+TM3XREC1 remote extension.
  2. version G (borne à ressort) partage des performances électriques identiques avec la variante à bornes à vis, only terminal construction differs.
  3. Logiciel: Expert en machines EcoStruxure (formerly SoMachine) pour la configuration de tous les modules TM3.
  4. Montage: Installation sur rail DIN, modules mis en cascade via des verrous du fond de panier.