ABBACS355-03E-07Convertisseur de fréquence A3-4 - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

ABBACS355-03E-07Convertisseur de fréquence A3-4 - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

API/

ABBACS355-03E-07Convertisseur de fréquence A3-4

Description du modèle: ACS355 machinery drive frequency converter; 03E = 3-phase input, IP20 enclosure; 07A3 = rated output 7.3 UN; 4 = 380–480 V voltage class Part Number: 3AUA0000058188 ✅ Core Electrical Specifications Rated Power: 3.0 kW (light overload / droit standard) Rated Output Current I₂ₙ: 7.3 Une entrée: 3-phase 380–480 V ±10%, 48–63 Hz Output: ...

  • Détails du produit

Description du modèle: ACS355 machinery drive frequency convertisseur; 03E = 3-phase input, IP20 enclosure; 07A3 = rated output 7.3 UN; 4 = 380–480 V voltage class

Numéro de pièce: 3AUA0000058188

✅ Spécifications électriques de base

Puissance nominale: 3.0 kW (light overload / droit standard)

Rated Output Current I₂ₙ: 7.3 UN

Saisir: 3-phase 380–480 V ±10%, 48–63 Hz

Sortir: 0 ~ Uₙ, 0–599 Hz

Enclosure Protection: IP20 (without +B063 or other options)

Taille du cadre: R0

Refroidissement: Refroidissement par air

Moteur compatible: 3 kW 3-phase asynchronous motor

📦 Dimensions & Poids

Unité: W70 mm × H239 mm × D161 mm

Poids net: 1.8 kilos

Packaged Size: 350×220×130 mm, Poids brut 2.3 kilos

🧩 On-board I/O (Standard)

5 Entrées numériques (DEPUIS)

1 Sortie relais (RO)

2 Entrées analogiques (IA, 0–10 V / 4–20 mA)

1 Sortie analogique (AU, 4–20 mA)

Modbus RTU intégré (Terminal X1)

Optional plug-in communication adapters: Profibus-DP, CANopen, AppareilNet, EtherCAT, etc..

📌 Applications typiques

Machines générales: convoyeurs, les fans, pompes, mélangeurs, small processing machines. Supports standard V/F control and vector control, vitesses prédéfinies, ramps, multi-set parameter groups.

⚠️ Sélection & Notes de remplacement

  1. For IP66 version: add suffix +B063. Dimensions and weight differ completely, part number changes.
  2. Upgrade alternative within ABB portfolio: ACS380. Older ACS350 of the same power can be cross-referenced by current rating.
  3. Fusible / disjoncteur: sized per 7.3 A converter standard circuit. Output du/dt reactor is optional.

📎 Common Spare Parts & Accessoires

Control Panels: ACS-CP-A / ACS-CP-D

Input filter, output du/dt filter, résistance de freinage (braking chopper built-in)

Adaptateurs de communication, Modules d'extension d'E/S

ABB ACS355 (ACS355-03E-07A3-4)|Factory Default Parameters for ABB Standard Macro (9902=1)

Note: Parameters in Group 99 (données de la plaque signalétique du moteur) have no fixed default values. Enter data per 3 kW motor nameplate after power-up.

Numéro de paramètre.Nom du paramètreValeur par défautRemarques
9902Application Macro Selection1 ABB Standard MacroDI1 start, DI2 direction, AI1 reference; le plus largement utilisé
9904Motor Control Mode3 Scalaire (V/F)Facultatif: 1=Vector Speed, 2=Vector Torque
9905Motor Rated Voltage—Follow nameplate; 380 V for standard 3 Moteur kW
9906Courant nominal du moteur—Typical value for matched motor ≈6.2 A
9907Motor Rated Frequency—50 Hz for general asynchronous motors
9908Motor Rated Speed—1440 tr/min (4-pôle)
9909Motor Rated Power—3.0 kW
1001Ext1 Start/Stop Command2 DI1DI1 closed = Run
1002Ext Direction Command3 DI2DI2=0 Forward, DI2=1 Reverse
1103Ext Reference 1 Sélection1 AI1AI1 0–10 V / 4–20 mA
1105Ext Reference 1 Maximum50.0 HzMatches full-scale AI signal
1201Constant Speed Selection0 Not SelectedMulti-speed via DI combination
1301AI1 Minimum0.0 V0 V correspond à 0 Hz
1302AI1 Maximum10.0 V10 V correspond à 50 Hz
1304AI2 Minimum0.0 VAI2 disabled by default
1401Relay Output RO1 Source0 ReadyOutput when drive is ready
1501AO1 Signal Source102 Fréquence de sortieAU: 4–20 mA mapped to 0–50 Hz
1504AO1 Minimum Output4 mA
1505AO1 Maximum Output20 mA
2007Minimum Frequency0.0 Hz
2008Maximum Frequency50.0 Hz
2202Temps d'accélération 15.0 s
2203Temps de décélération 15.0 s
2102Stop Mode1 Coast Stop2=Ramp Stop
2601U/F Ratio1 LinéaireSquared for fan/pump duty
3017Overcurrent Trip Limit4×I₂n
3025STO Function0 Alarm OnlyRégler sur 1 triggers fault 0044
5302EFB Station Address1Modbus RTU Slave Address
5303Débit en bauds9600
5304Parité0 No Parity, 1 Stop Bit

ACS355 Fault Code List (English with Troubleshooting Guidance)

Code d'erreurNom du défautDescriptionDépannage courant
1SURINTENSITÉOutput current exceeds trip thresholdCourt-circuit moteur, dommages au câble, locked load, temps de rampe trop court, incorrect motor data
2DC OVERVOLTDC bus voltage too highDécélération rapide, regenerative load, high supply voltage, manque de résistance de freinage
3DEV OVERTEMPIGBT module overtemperatureBlocked airflow, ventilateur en panne, température ambiante élevée, surcharge, mauvaise ventilation de l'armoire
4SHORT CIRCMotor-side short circuitMotor winding short, phase-to-phase short on power cable, shorted output terminals
6DC UNDERVOLTDC bus voltage insufficientPhase d'entrée manquante, open fuse/contact, voltage dip, undersized supply
9MOT OVERTEMPEstimated motor temperature exceededSurcharge du moteur, mauvais refroidissement, incorrect motor thermal protection settings
16EARTH FAULTEarth leakage on motor/power cableDamaged cable insulation, motor insulation failure, moisture ingress
22SUPPLY PHASEPerte de phase d'entrée / 3-déséquilibre de phaseFusible d'entrée grillé, poor contactor contacts, unbalanced 3-phase supply
44SAFE TORQUE OFF (STO)STO safety circuit activatedSTO terminals not jumpered, safety loop open, parameter 3025=1 triggers fault
28COMM ERRORBuilt-in EFB bus communication breakModbus wiring, résistance de terminaison, address conflict, master offline
35AI1 LOSSAI1 signal below fault thresholdTransmitter wire break, faulty sensor, threshold setting in 3021
36AI2 LOSSAI2 signal lossBroken AI2 wiring, faulty transmitter
41ID RUN FAILMotor identification run failedWrong motor wiring, mismatched power rating, rotor bloqué
51USER PARAM FAULTParameter set corruptedRestore factory defaults and re-enter motor parameters
71FAN FAULTCooling fan failureFan jammed, fan supply fault

✅ Reset Methods: Panel RESET, DI reset, communication reset, cycle d'alimentation. Fault history stored in Group 04 paramètres.

Quick Operation

Réinitialisation d'usine: Paramètre 9606, enter RESET. The drive restarts and loads ABB Standard Macro defaults.

Installation Notes for ABB ACS355-03E-07A3-4 (Frame R0, IP20)

This unit is for cabinet installation only. Indice IP20, not suitable for direct outdoor exposure.

  1. Montage mécanique & Dissipation thermique
  2. Orientation de montage: Vertical upright installation is mandatory. Do not invert. Side mounting is permitted for R0 frame but vertical is preferred. Cooling air flows bottom-in, top-out; inverted mounting causes overheating fault 0003.
  3. Minimum Clearances

Top ≥75 mm, Bottom ≥75 mm; no mandatory side clearance, reserve space for maintenance.

Stacked multiple drives: hot exhaust from lower unit must not blow directly onto upper unit. Use baffles, staggered layout or independent air ducts.

  1. Mounting Options: Screw fixing or 35 Rail DIN standard de mm. Mounting base must be rigid and flame-retardant. Prevent conductive dust from entering the unit during drilling (risk of short circuit).
  2. Conditions ambiantes

Température ambiante: -10 ~ +50 °C; déclasser au-dessus 40 °C. Pas de condensation, pas de glaçage.

Altitude: Full rating ≤1000 m; derate with increasing altitude above 1000 m.

Prohibited environment: conductive dust, gaz corrosif, strong magnetic fields (near contactors / large single-core cables), heavy vibration or shock.

  1. Sécurité & Power-off Procedures (Critique)

After disconnection, attendez 5 minutes for DC bus capacitors to fully discharge before opening covers, wiring or measuring. Do not touch power terminals or internal PCB when powered.

For permanent magnet motors: motor may generate back EMF when rotating even with supply disconnected. Mechanically lock the shaft before working on motor cables.

Before power-up: Disconnect U2/V2/W2 at the converter, test motor insulation to earth with 1000 V megger. Do not energise if insulation is poor (≥100 MΩ @25°C for ABB motors).

Strictly forbidden: Connect mains supply to U2/V2/W2 output terminals, this will destroy the unit.

  1. Sélection des câbles, Routing & CEM
  2. Cable Recommendations

Motor cable: Symmetric shielded VFD cable preferred, reduces bearing currents and EMI. Unshielded standard cables often interfere with sensors and instruments.

Signaux analogiques (IA/Monde): Double-shielded twisted pair. DI/DO relay signals: shielded twisted pair. Separate power cables and control cables in different trunking, minimum gap ≥20 cm. Cross only at 90° where unavoidable.

Do not mix 24 V low-voltage and 220 V high-voltage circuits inside one cable.

  1. Shield Grounding Rules

360° shield termination with earthing clamp; avoid pigtail earthing (poor high-frequency EMC performance). Shield of motor cable grounded at both converter and motor ends.

PE conductor must be short, thick and connected reliably to cabinet earth bar.

  1. IL / Ungrounded Delta System: Remove internal EMC filter earth screw, otherwise earth fault 0016 may occur. Keep screw fitted for standard TN-S systems.
  2. Output-side Restrictions: Do not connect capacitors or surge suppressors to U2/V2/W2. For long motor cables (>50 m), fit output du/dt reactor to protect motor insulation.
  3. Couple aux bornes & STO Safety Circuit

Control terminal tightening torque: 0.4 N·m. Power terminals follow datasheet torque specification.

STO (Coupure sûre du couple): Factory fitted with jumper. If STO function is unused, STO terminals must be permanently jumpered. Open STO triggers fault 0044. For safety applications, wire to safety relay contacts.

Résistance de freinage (BRK+, BRK-): Utiliser un câble blindé, mount close to drive to minimise lead inductance.

  1. Input Protection, Mise à la terre & Auxiliary Devices

Fit circuit breaker or fuses on input side, sized for 7.3 Une note. Input AC reactor is recommended to reduce harmonic distortion.

Mise à la terre: PE conductors must be home-run separately to earth bar, do not daisy-chain. Never use neutral N as protective earth PE.

Cabinet ventilation: Install cabinet fans to keep internal temperature below 40 °C. Clean filters regularly to prevent blocked cooling paths.

  1. Pre-power-up Checklist
  2. Bornes de puissance: U1/V1/W1 supply, U2/V2/W2 motor, BRK+/braking resistor – verify connections.
  3. Circuits de contrôle: DI/AI/AO, STO jumper, mise à la terre du blindage.
  4. Insulation test passed, no short circuit or earth leakage.
  5. Air path unobstructed.
  6. Motor nameplate data ready; perform motor identification after first power-up.
  7. Installation-related Fault Quick Reference

0003 Overtemp: Blocked airflow, insufficient top/bottom clearance, montage inversé, high cabinet temperature

0016 Défaut de terre: Mise à la terre incorrecte du blindage, EMC screw not removed for IT system, damaged/wet motor cable

0044 STO Fault: STO terminals not jumpered, safety loop open

Fluctuating AI signals: Mixed power/control wiring, poor shield grounding, non-twisted analog cable

ABB ACS355 Model & Part Number List|03E 3-phase 380–480 V, IP20, Filtre CEM intégré, Version standard

Description du modèle:

03 = entrée triphasée; E = EMC filter enabled (50 Hz); trailing 4 = 380~480 V; +B063 = IP66 high protection variant (commande séparée)

Part Number format: 3AUA00000XXXXX (ABB part number, used for purchasing, quotation and customs declaration)

Tailles de cadre: R0/R1/R3/R4; built-in braking chopper and STO.

ModèlePuissance nominale kWOutput Current I₂N(UN)CadreABB Part Number (3AUA)
ACS355-03E-01A2-40.371.2R03AUA0000058186
ACS355-03E-01A9-40.551.9R03AUA0000058243
ACS355-03E-02A4-40.752.4R03AUA0000058187
ACS355-03E-03A3-41.13.3R13AUA0000058184
ACS355-03E-04A1-41.54.1R13AUA0000058185
ACS355-03E-05A6-42.25.6R13AUA0000058189
ACS355-03E-07A3-437.3R03AUA0000058188
ACS355-03E-08A8-448.8R13AUA0000058190
ACS355-03E-12A5-45.512.5R33AUA0000058191
ACS355-03E-15A6-47.515.6R33AUA0000058192
ACS355-03E-23A1-41123.1R33AUA0000058193
ACS355-03E-31A0-41531R43AUA0000058195
ACS355-03E-38A0-418.538R43AUA0000058194
ACS355-03E-44A0-42244R43AUA0000058196

Supplementary Range: 01E Single-phase 200–240 V, IP20, CEM intégrée

ModèlePower kWCurrent ACadreNuméro de pièce
ACS355-01E-02A4-20.372.4R03AUA0000058174
ACS355-01E-04A7-20.754.7R13AUA0000058175
ACS355-01E-06A7-21.16.7R13AUA0000058176
ACS355-01E-07A5-21.57.5R23AUA0000058177
ACS355-01E-09A8-22.29.8R23AUA0000058178

Accessoires communs & Part Numbers for ACS355

Nom de l'accessoireModèleNuméro de pièce
Basic Control PanelACS-CP-A3AUA0000040901
Panneau de configuration adjoint (Chinois)ACS-CP-D3AUA0000040902
Profibus DP AdapterFPBA-013AUA0000040888
CANopen AdapterFCAN-013AUA0000040889
DeviceNet AdapterFDNA-013AUA0000040890
EtherCAT AdapterFECA-013AUA0000040891

Suffix Options (added after model +xxxx)

+B063: IP66 high protection version (pour humide, dusty environments)

+N830: Non-coated PCB (standard cabinet version)

+J400: Potentiometer kit

Exemple: ACS355-03E-07A3-4+B063 (IP66 variant, numéro de pièce différent)

Model Code Guide for Export Selection

03E: 3-phase, EMC filter enabled (mainstream for China market) ✅

03U: 3-phase, EMC filter disabled (60 Hz overseas version)

03X: Export special version, not common locally

01E / 01U: Monophasé 220 V models

Replacement series: ACS380 (nouvelle génération, successor to ACS355)

Précédent:

Suivant:

Laisser une réponse