- Model Segment Definition
XPSAV11113-24VDC
XPSAV: Schneider Safety Monitoring Relay Série, dedicated to dual-channel safety circuits for emergency stop, safety door and safety light curtain.
11113: Internal contact logic and channel configuration code.
24VCC: Rated power supply 24V DC.
- Core Basic Parameters
| Article | Spécification |
| Marque | Schneider |
| Type de produit | Industrial Safety Relay (Dual-channel Redundant Safety Type) |
| Rated Supply | 24VCC |
| Plage de tension | 20.4~26.4VDC |
| Safety Level | PL d / Cat.3, SIL2 |
| Type de montage | DIN35 Rail Mounting |
| Scénarios d'application | Machines-outils, automatic production lines, robot emergency stop / safety door circuits |
- Principales fonctionnalités
- Dual-channel redundant input with safety forced-guided contacts;
- Millisecond-level safety cut-off response;
- Only supports 24V DC power supply; AC voltage input is prohibited;
- Built-in self-diagnosis and circuit monitoring functions.
- Compatible Replacement Models
- Same-brand direct replacement: Direct replacement with the same model; no upgraded alternative version
- Domestique / Cross-brand compatible models:
Omron G9SA-301 24VDC
Weidmüller Dual-channel Safety Relay 24VDC
Siemens 3RK3 series 24V safety module with equivalent specifications
- Notes d'application
Safety signals must be connected synchronously through dual channels; single-channel connection cannot work normally;
Strictly prohibit mixed use with AC24V power supply, which will directly burn out the module;
Output contacts are only used for safety circuit control and cannot directly drive heavy loads.
Schneider Safety Monitoring Relay Series List & Comparaison entre marques
- Overview of Core Schneider Safety Monitoring Relay Series
Les relais de surveillance de sécurité Schneider sont centrés sur la série Preventa XPS, couvrant des fonctions de sécurité complètes telles que l'arrêt d'urgence, porte de sécurité, barrière immatérielle de sécurité et commande bimanuelle. Ils sont divisés en type de base et type universel, tous conformes à EN/ISO 13849-1 et CEI 61508 normes de sécurité.
| Série | Fonction principale | Safety Level | Application typique |
| XPSAV | Dual-channel emergency stop / safety door monitoring with solid-state output | PL e / Cat.4, SIL3 | Emergency stop circuits for machine tools and automatic production lines |
| XPSAF/XPSAFL | Emergency stop / porte de sécurité / light curtain monitoring, high/low level input | PL e/Cat.4(SIL3) / PL d/Cat.3(SIL2) | Safety light curtain and safety door interlock monitoring |
| XPSAC | Emergency stop button and limit switch monitoring | PL e / Cat.4, SIL3 | Simple emergency stop circuit and equipment limit protection |
| XPSAR | Dual-channel emergency stop / light curtain monitoring, 7 safety contacts + 2 contacts auxiliaires | PL e / Cat.4, SIL3 | Complex safety circuits and multi-equipment linkage |
| XPSATE/XPSATR | Configurable safety relay with time delay function | PL e / Cat.4, SIL3 | Safety scenarios requiring delay control |
| XPSCM | Dedicated monitoring module for light curtains | PL e / Cat.4, SIL3 | Safety light curtain / grating monitoring |
| XPSUAF/XPSUAT | Universal configurable safety relay | PL e / Cat.4, SIL3 | Replacement for XPSAR / XPSATE series |
- Model Segment Coding Rules
Taking XPSAV11113-24VDC as an example, Schneider safety relay model coding follows unified logic:
| Segment de code | Signification | Example Description |
| XPS | Product category identifier, Preventa safety relay series | All safety relays start with this prefix |
| AV/AF/AC/AR/ATE | Functional series code | AV=Emergency stop + solid-state output; AF=Standard emergency stop; AC=Basic emergency stop |
| 11113 | Internal configuration code | 1st digit = channel quantity; last four digits = contact type / quantité / reset mode |
| -24VDC/230VAC | Rated supply voltage | 24À DC / 230V et; some models support universal AC/DC |
| P. | Identifiant du type de terminal (facultatif) | P=Plug-in terminal; no suffix=screw terminal |
- Complete Model List of Each Series
3.1 XPSAV Series (Arrêt d'urgence + Solid-State Output)
| Modèle | Tension d'alimentation | Safety Contacts | Auxiliary Output | Mode de réinitialisation |
| XPSAV11113-24VDC | 24VCC | 3NO Instantaneous | 3 Solid-state Output | Automatique / Monitored Reset |
| XPSAV11113P-24VDC | 24VCC | 3NO Instantaneous | 3 Solid-state Output | Automatique / Monitored Reset (Plug-in Terminal) |
| XPSAV11123-24VDC | 24VCC | 3NO Instantaneous + 3NO Time-delay | 3 Solid-state Output | Réinitialisation manuelle |
| XPSAV11123P-24VDC | 24VCC | 3NO Instantaneous + 3NO Time-delay | 3 Solid-state Output | Réinitialisation manuelle (Plug-in Terminal) |
| XPSAV37113-230VAC | 230ACC | 3NO Instantaneous | 3 Solid-state Output | Automatique / Monitored Reset |
| XPSAV37113P-230VAC | 230ACC | 3NO Instantaneous | 3 Solid-state Output | Automatique / Monitored Reset (Plug-in Terminal) |
3.2 XPSAF/XPSAFL Series (Standard Emergency Stop / Light Curtain Monitoring)
| Modèle | Tension d'alimentation | Safety Level | Input Type | Safety Contacts |
| XPSAF5130 | 24VAC/DC | PL e / Cat.4 | High/Low Level Dual-channel | 3NON |
| XPSAF5130P | 24VAC/DC | PL e / Cat.4 | High/Low Level Dual-channel | 3NON (Plug-in Terminal) |
| XPSAF5130P-230VAC | 230ACC | PL e / Cat.4 | High/Low Level Dual-channel | 3NON (Plug-in Terminal) |
| XPSAFL5130 | 24VAC/DC | PL d / Cat.3 | High Level Dual-channel | 3NON (No Short-circuit Detection) |
| XPSAF3730P | 230ACC | PL e / Cat.4 | High/Low Level Dual-channel | 3NON (Plug-in Terminal) |
3.3 XPSAC Series (Basic Emergency Stop Monitoring)
| Modèle | Tension d'alimentation | Safety Contacts | Caractéristiques |
| XPSAC5121 | 24VCC | 2NON | Type de base, Cat.3 |
| XPSAC5121P | 24VCC | 2NON | Type de base, Cat.3 (Plug-in Terminal) |
| XPSAC3721P | 230ACC | 2NON | Type de base, Cat.3 (Plug-in Terminal) |
| XPSAC5140 | 24VCC | 4NON | Enhanced Type, Cat.4 |
3.4 XPSAR Series (Multi-contact Emergency Stop / Light Curtain Monitoring)
| Modèle | Tension d'alimentation | Safety Contacts | Contacts auxiliaires | Caractéristiques |
| XPSAR311144P | 24VAC/DC | 7NON | 2Caroline du Nord | Dual-channel, Cross-wire Monitoring |
| XPSAR351144P | 115ACC | 7NON | 2Caroline du Nord | Dual-channel, Cross-wire Monitoring |
| XPSAR371144P | 230ACC | 7NON | 2Caroline du Nord | Dual-channel, Cross-wire Monitoring |
3.5 Universal XPSU Series (Replacement for Traditional Series)
| Modèle | Replaced Series | Tension d'alimentation | Safety Contacts | Contacts auxiliaires |
| XPSUAF13AP | XPSAF | 24VAC/DC | 3NON | 1Caroline du Nord (Diagnostic Output) |
| XPSUAF13AC | XPSAF | 24VAC/DC | 5NON | 4 Contacts auxiliaires |
| XPSUAT13A3AP | XPSATE | 24VAC/DC | 3NON + 3 Time-delay NO | 3 Solid-state Output |
- Cross-Brand Comparison Table (Modèles grand public)
| Modèle Schneider | Omron Replacement | Remplacement Siemens | Pilz Replacement | Weidmüller Replacement |
| XPSAV11113-24VDC | G9SA-301 24VDC | 3SK1111-2AB40 | PNOZ X3 24VDC | SAFESERIES 24VDC Dual-channel |
| XPSAF5130 | G9SA-501 AC/DC24 | 3SK1122-2AB40 | PNOZ X4 24VAC/DC | PROMAX 24VAC/DC 3NO |
| XPSAC5121 | G9SA-101 24VDC | 3SK1101-2AB40 | PNOZ X1 24VDC | SAFESERIES 24VDC 2NO |
| XPSAR311144P | G9SA-321 AC/DC24 | 3SK1162-2AB40 | PNOZ X7 24VAC/DC | PROMAX 24VAC/DC 7NO+2NC |
| XPSUAF13AP | G9SA-511 AC/DC24 | 3SK2122-2AB40 | PNOZ X4P 24VAC/DC | PROMAX 24VAC/DC 3NO+Diagnostic |
- Lignes directrices de sélection & Replacement Precautions
- Safety Level Matching: The PL / Cat. level and SIL level of the replacement model shall not be lower than the original one.
- Input Type Compatibility: Distinguish High/Low Level Input and PNP/NPN types; XPSAF supports dual types, while XPSAFL only supports high level.
- Consistent Reset Mode: Divided into Automatic Reset, Monitored Reset and Manual Reset, which shall match the application scenario.
- Type de borne: Suffix P stands for plug-in terminal; no suffix for screw terminal. Pay attention to mounting compatibility during replacement.
- Tension d'alimentation: Strictly distinguish DC24V, AC230V and Universal AC/DC to avoid module burnout.
- Series Replacement Roadmap
Schneider is gradually replacing traditional series with the XPSU Universal Series:
XPSAR → Combined XPSUAF + XPSUEP or XPSUAT series
XPSATE/XPSATR → XPSUAT series
XPSAF/XPSAV → XPSUAF series
Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires