Siemens 3SE5112-0CH50 Limit Switch - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 Siemens 3SE5112-0CH50 Limit Switch - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

électrique/

Siemens 3SE5112-0CH50 Limit Switch

Série: SIRIUS 3SE5 mechanical position limit switch (standard position switch, NOT positive-opening safety switch) ✅ Model Code Explanation 3SE5: SIRIUS family of mechanical position switches 3SE51: Metal enclosure, 40mm largeur, conforme à la norme EN 50041 12: 1NON + 1NC snap-action contacts 0CH50: Adjustable-length metal lever with φ19mm plastic roller; rotary actuator reversible for left/right mounting 📋 ...

  • Détails du produit

Série: SIRIUS 3SE5 mechanical position interrupteur de fin de course (standard position switch, NOT positive-opening safety switch)

✅ Model Code Explanation

3SE5: SIRIUS family of mechanical position switches

3SE51: Metal enclosure, 40mm largeur, conforme à la norme EN 50041

12: 1NON + 1NC snap-action contacts

0CH50: Adjustable-length metal lever with φ19mm plastic roller; rotary actuator reversible for left/right mounting

📋 Core Technical Specifications

ArticleParamètre
USB InterfaceUSB‑A, USB1.1/2.0 full‑speed, USB‑bus‑powered (≈50 mA)
Field Side2‑wire differential RS‑485, Uni‑Telway protocol dedicated
Débit en bauds300 bps‑1 Mbps
DIP Rotary Switch4‑position rotary switch for point‑to‑point/multidrop,‑TER‑port/other‑port selection
Indicateurs LEDPOWER power, TX transmit, RX receive
Température de fonctionnement‑40~+85℃, DIN‑rail clip‑on mounting support
Standard CableTSXCRJMD25 (Mini‑DIN8); XBTZ925 required separately for Twido RJ45 port
Supported SoftwarePL7‑Pro, Unité Pro (Control Expert), TwidoSoft
ArticleSpécification
Configuration des contacts1NON + 1Caroline du Nord, snap-action
EnceinteBoîtier métallique, 40mm largeur
Entrée de câbleM20×1.5 single cable gland
Classe de protectionIP66 / IP67
Tension d'isolement nominale Ui400V
Courant thermique conventionnel Ith6UN
AC-15 (24V)3UN; DC-13 (24V)
Durée de vie mécanique15,000,000 cycles
Couple de fonctionnement0.25 Nm
Température de fonctionnement-25℃ ~ +85℃
ActionneurTelescopic metal lever, φ19mm plastic roller, lever length adjustable from 0~100mm, reversible left/right
PoidsEnviron. 0.3kilos
Country of OriginAllemagne
Code SH85365080

📌 Product Features

  1. Modular construction: Composed of base housing, contact module, rotary actuator head and adjustable lever. Components can be replaced individually. Part numbers: Base 3SE5112-0CA00, actuator head 3SE5000-0AH00, lever 3SE5000-0AA50, contact block 3SE5000-0CA00
  2. Bidirectional reversal: Rotary head can be switched left or right to adapt to forward/reverse stroke triggering of equipment
  3. Adjustable lever length, convenient for fine-tuning trigger position on site
  4. Impact-resistant metal housing, adapté aux machines-outils, conveyor lines and automation sites
  5. ⚠️ Avis important: No positive opening function. NOT permitted for safety protection circuits (par exemple. safety gate interlock). Only for general position detection, travel limit and home position feedback signals.

🛠️ Typical Application Scenarios

Conveyor travel limit, machine tool stroke limit, automation frame position detection, mechanical trigger for silo material level, general position feedback of doors (non-safety interlock)

🔁 Substitute & Référence de sélection

Same series alternative (different actuator): 3SE5112-0CH01 (fixed-length lever)

Référence alternative nationale: Délicieux, Chint, Omron WL series roller lever limit switches (verify contact capacity, mounting dimensions and protection rating)

Model for safety applications: 3SE53xx series (positive-opening safety switches)

⚠️ Installation & Notes d'entretien

  1. Mounting holes comply with EN50041 standard; reserve buffer stroke for the lever to prevent roller damage from impact
  2. Properly seal the M20 cable gland to maintain IP67 protection
  3. Snap-action contacts are not suitable for high-frequency low-level signals; intended for power-type switching signals
  4. Periodically inspect lever wear and screw tightness; worn rollers allow replacement of actuator assembly alone, full switch replacement unnecessary

Application Scenarios of Siemens 3SE5112-0CH50

⚠️ Important Premise: Standard position switch without positive-opening contacts. Cannot be used for safety gates, safety circuits or emergency stop safety interlock. Only for general position feedback, travel limit and process trigger signals. IP66/IP67, metal housing with adjustable lever, suitable for dusty and humid industrial environments.

  1. Convoyeur & Automatisation de la logistique (Le plus courant)
  2. Ceinture / convoyeurs à rouleaux: Hard mechanical limit at head and tail to prevent trolley/stop block overtravel; position signal sent to PLC for deceleration, stop and direction change
  3. Transfer carts, shuttle trolleys: Home position locating and end-position detection
  4. Tri & lignes de conditionnement: Box-in-place trigger, stop plate position feedback
  5. Ascenseurs & vertical conveying equipment: Upper/lower limit signals for lifting platforms (general limit only; separate safety switch required for safety protection circuit)
  6. Machines-outils & Processing Equipment
  7. Machines CNC, centres d'usinage: Hard mechanical limit for worktable slides and saddles (backup for soft limit), travel end detection for X/Y/Z axes
  8. Press brakes, cisailles: Slide / material rack in-position signal and stroke end feedback (not for safety protection)
  9. Machines à bois, broyeurs: Mobile worktable in-position detection and process switching trigger signals

III. Automatisation personnalisée & Assembly Equipment

  1. Jigs & luminaires: Clamp closed/open position feedback
  2. Servo slides, cylinder-driven mechanisms: Mechanical end limit and home position confirmation
  3. Tooling around robots: Silo baffle and discharge mechanism position detection

Avantage: 0~100mm adjustable lever length, reversible actuator head for easy on-site fine-tuning of trigger position

  1. Material Storage & Silo Applications
  2. Silo gates, flap valves: Full-open / full-closed position feedback
  3. Warehouse mechanical level detection: Material push plate in-position detection
  4. Levage, Porte & Machines de construction (General Position Signals)
  5. Overhead cranes, petits palans: General travel limit for cross/longitudinal carriages (safety ultimate limit must use safety-type switches)
  6. Factory motorized sliding doors, volets roulants: Full-open / full-closed position feedback (non-safety interlock)
  7. Hydraulique / pneumatic actuators: Cylinder end position detection
  8. Autres applications industrielles générales

Impression & machines textiles: Roller frame and moving frame stroke detection

Traitement de l'eau & environmental equipment: Baffle and discharge mechanism position signals

General position indication for equipment access doors (⚠️ NOT for safety interlock door switches; safety gates require 3SE53xx positive-opening safety switches)

✅ Selection Checklist (Éviter les pièges)

  1. Adjustable metal lever + φ19 plastic roller, suitable for lateral impact from moving stop blocks; long lever preferred where installation space is ample and trigger position fine adjustment is required
  2. 1NO+1NC snap-action contacts for PLC DI position signals, AC15/DC13 24V 3A
  3. Adéquation environnementale: -25℃~+85℃, IP67, impact-resistant metal housing, ideal for dusty and humid workshops
  4. ❌ Forbidden applications: Safety gate interlock, emergency stop safety circuits, ISO13849 safety-related circuits (use 3SE53xx positive-opening safety position switches for these cases)

Voltage Parameters of Siemens 3SE5112-0CH50

This is a mechanical limit switch with no internal power supply required, it is merely passive contacts. Below are the permissible rated switching voltages for contacts:

  1. Tension d'isolement nominale Ui: 400V (maximum withstand voltage)
  2. AC-15 AC Operating Voltage (charge inductive)

24V et / 125V et / 240V et / 400V et

400V et: 4UN; 24/125/240V et: 6UN

  1. DC-13 DC Operating Voltage (charge inductive, most common for PLC DI)

24À DC: 3UN (widely used for PLC digital input)

125À DC: 0.55UN

250À DC: 0.27UN

400À DC: 0.12UN

✅ Engineering Selection Notes

PLC DI digital signal: DC24V, entièrement compatible, the most common usage of this model

Also applicable for AC220V circuits to switch high-power loads

Passive dry contacts, no power supply needed for the switch body

Mounting Dimensions of Siemens 3SE5112-0CH50 (EN50041 40mm Metal Housing)

Référence: Siemens original datasheet; dimensions separated for housing without lever and full assembly with lever

  1. Outer Housing Dimensions (excluding lever)

Largeur: 40.5 mm

Hauteur: 85.7 mm

Profondeur: 37.3 mm

  1. Mounting Fixing Holes (critical hole dimension, EN50041 standard)

Vertical center distance between two fixing holes: 61 mm

Diamètre du trou de montage: 5.3 mm (suitable for M5 bolts)

Distance from hole to side edge: 12.5 mm

Mounting orientation optional, 4 trous de montage (2 haut, 2 bas). Standard 40mm footprint, mounting holes fully interchangeable for all 3SE51xx base units.

  1. Actuator Lever Dimensions (adjustable metal lever + φ19 roller)

Roller diameter: φ19 mm (plastic roller)

Lever adjustment range: Min. 44 mm, Max. 109 mm (from rotary head center to roller center)

Overall maximum total length with lever fully extended: 192 mm

Actuator head reversible 180° left/right

  1. Entrée de câble

Single cable entry: M20 × 1,5

  1. Key Engineering Remarks
  2. Mounting plate cutout: Fixing hole center distance 61mm, hole φ5.3, fasten with M5 bolts
  3. Adjustable lever: Reserve sufficient buffer stroke. Stop block impact direction must be perpendicular to roller; do not forcibly bend laterally to avoid shaft damage
  4. Housing depth 37.3mm; reserve space for rear cover and cable gland during backplate mounting; M20 gland exits from bottom of housing
  5. Base mounting holes common across 3SE51xx series; no re-drilling required when replacing actuator head

 