IFM PN7032 ディスプレイ付き圧力センサー - コンタクタ,サーキットブレーカー,センサー,エンコーダ,PLC,コンバータ

微信: +86-13184948252 ワッツアップ: 0086-13811255435 電子メール: kent@bestcontactor.com

について 接触 |

IFM PN7032 ディスプレイ付き圧力センサー - コンタクタ,サーキットブレーカー,センサー,エンコーダ,PLC,コンバータ

電気/

IFM PN7032 ディスプレイ付き圧力センサー

完全なモデル番号: PN-100-SER14-QFRKG/US/ /V PN7032 belongs to PN70xx series, a relative pressure sensor with digital display, two switching outputs and IO-Link on one channel. It adopts ceramic-capacitive measuring cell, widely used for pressure switches and transmitters in industrial hydraulic and pneumatic systems. ✅ Key Specifications Item Parameter Measuring range 0…10 MPa (0~100バール), relative ...

  • 製品詳細

完全なモデル番号: PN-100-SER14-QFRKG/US/ /V

PN7032 belongs to PN70xx series, a relative pressure sensor with digital display, two switching outputs and IO-Link on one channel. It adopts ceramic-capacitive measuring cell, widely used for pressure switches and transmitters in industrial hydraulic and pneumatic systems.

✅ Key Specifications

アイテムパラメータ
測定範囲0…10 MPa (0~100バール), relative pressure
プロセス接続G1/4 internal thread; rotatable display head
Measuring elementCeramic-capacitive
Overpressure30 MPa; Burst pressure 65 MPa
出力2 x PNP switching outputs; OUT2 multiplexed for IO-Link
電源18…30 V DC; 逆極性保護 & 短絡保護
Medium temperature-25 ~ +80 ℃
侵入保護IP67; M12 A-coded 5-pin gold-plated connector
画面4-digit red/green digital display, tri-color status indicator, 3-key menu
Switch settingSP: 0.1~10 MPa; rP reset point; minimum hysteresis 0.05 MPa
Response frequencyマックス. 170 Hz
中くらいPrimarily for liquids; gas applications above 25 bar require separate evaluation

✅ Model Code Explanation

PN-100-SER14-QFRKG/US/ /V

PN: Series with display

100: Measuring range 0~10 MPa

S: 2 switching outputs

E: IO-Link function

R: G1/4 internal thread

14: M12 5-pin electrical connector

QFRKG: Code for housing, sealing and electrical configuration

✅ Product Features

  1. IO-Link通信: Read real-time pressure, temperature and diagnostic data; remote parameter read/write via PLC, device identification and fault diagnosis supported.
  2. Rotatable display head for convenient viewing after installation.
  3. Red/green color-changing display: green within valid pressure range, red when threshold exceeded.
  4. Ceramic cell, good resistance to pressure spikes and excellent long-term stability.
  5. Two independent switch points for high/low pressure dual alarm.
  6. Built-in short-circuit and reverse polarity protection, 過酷な産業環境に適しています.

✅ Typical Applications

Hydraulic station pressure monitoring, lube oil circuits, cooling water systems, high-pressure pneumatic loops, 射出成形機, 工作機械, ポンプ場, エアコンプレッサー.

✅ Reference Replacement Models

PN7032 (0~10MPa, G1/4 internal thread, IOリンク)

PN7033: 0~2.5MPa

PN7034: 0~1MPa

PN7036: 0~0.25MPa

注記: PN7032 is partially phased out. For new projects, consult IFM PN72 series alternatives. 糸, measuring range, IO-Link and output logic need to be verified.

✅ Pin Assignment (M12 5-pin A-coded)

1: Power +18~30V DC

2: OUT1 (PNP switch)

3: Power GND

4: OUT2 / IOリンク

5: Not used

✅ Common Troubleshooting

  1. 表示なし: Check supply voltage and confirm no reverse connection.
  2. Pressure reading drift: Verify medium temperature and pressure spikes upstream; ceramic cell is vulnerable to continuous overpressure.
  3. IO-Link communication failure: Check pin 4, IO-Link master baud rate and matched IODD file.
  4. Switch output not actuating: Enter menu to verify SP/rP setting and output mode (window / hysteresis).

比較表: IFM PN7032 vs PN72 Series (PN7292, 直接交換)

PN7032: PN-100-SER14-QFRKG/US/ /V (製造中止)

PN7292: PN-100-REN14-QFRKG/US/ /V (official recommended replacement, 0~10MPa, G1/4 internal thread, 2×PNP + IOリンク)

比較項目PN7032PN7292 (PN72 Series Replacement)備考
フルモデルPN-100-SER14-QFRKG/US/ /VPN-100-REN14-QFRKG/US/ /VIdentical measuring range: 0…10 MPa (0~100バール) relative pressure
Measuring CellCeramic-capacitiveCeramic-capacitive同じ, resistant to pressure spikes, suitable for hydraulic/lube oil
プロセス接続G1/4 internal threadG1/4 internal threadMechanically fully compatible, direct swap-in
Electrical ConnectorM12 A-coded 5-pinM12 A-coded 5-pinPinout identical, no cable rework required
出力構成2×PNP switching outputs, OUT2 multiplexed IO-Link2×PNP switching outputs, OUT2 multiplexed IO-Link; output software-selectable PNP/NPNPN72 adds PNP/NPN software switching
電源18…30 V DC18…30 V DCSame range, reverse polarity & 短絡保護
Overpressure30 MPa30 MPa同一
Burst Pressure65 MPa65 MPa同一
中温−25 ~ +80 ℃−25 ~ +80 ℃同じ温度範囲
侵入保護IP67IP67Same housing protection
画面4-digit red/green digital display, tri-color status, 3 keys4-digit red/green LED, side status indicators, 3 keysSame display logic; display head 360° rotatable
IO-Link VersionIOリンク 1.1IOリンク 1.1IODD files differ; PLC project needs IODD update
Switch Point SetupSP, rP hysteresis; min hysteresis 0.05 MPaSP, rP hysteresis; min hysteresis 0.05 MPaMenu logic mostly consistent; PN72 supports more pressure units
Response Frequencyマックス. 170 Hzマックス. 170 HzSame dynamic response
全体の寸法Identical body outlineIdentical body outlineNo modification to mounting space or bracket
主な違いFixed PNP outputSoftware PNP/NPN toggle; more menu parameters; extended diagnostic information; improved service life (>100 million pressure cycles)✅ Direct replacement for most applications; ⚠️ IO-Link projects require IODD update

PN72 Series Selection List for PN70xx Equivalents

測定範囲Original PN70xx ModelPN72 Series Replacement
0~10 MPa /100 バーPN7032PN7292G1/4 internal thread
0~2.5 MPa /25 バーPN7033PN7293G1/4 internal thread
0~1 MPa /10 バーPN7034PN7294G1/4 internal thread
0~0.25 MPa /2.5 バーPN7036PN7296G1/4 internal thread

⚠️ Replacement Engineering Notes

  1. 機械的設置: Thread and physical dimensions are identical; can be directly screwed into existing piping.
  2. 電気配線: M12 5-pin pinout fully identical, no cable modification needed.
  3. Switch-only Application (IOリンクなし): 直接交換, re-set SP/rP parameters only; PLC program unchanged.
  4. IO-Link Application: IODD file update mandatory. PN7032 and PN7292 IODD are not interchangeable; different device ID, PLC will recognize it as new equipment.
  5. 出力タイプ: PN7032 fixed PNP; PN7292 factory default PNP, can be switched to NPN via menu.
  6. Pressure Units: PN72 supports more units (bar/MPa/psi etc.), older PN7032 has fewer unit options.
  7. Media Note: Ceramic cell, avoid strongly corrosive media; high-pressure gas applications require separate evaluation.

Limitation Statement

PN72 series (PN7292) is functionally compatible replacement instead of 100% firmware identical. Diagnostic parameters and device ID read via IO-Link differ. For pure switch signals, zero-modification replacement; IO-Link projects require PLC IODD update and parameter download.

Complete Installation Instructions for IFM PN7032 Pressure Sensor

PN7032: G1/4 internal thread, M12 A-coded 5-pin, ceramic cell, gauge pressure 0~10MPa; Depressurize system and cut off power before installation

  1. インストール前の準備
  2. Safety Check

Shut down and depressurize piping; confirm medium, temperature and maximum pressure do not exceed PN7032 specification (medium -25~80℃, overpressure 30MPa).

  1. Pressure Tap Selection

Liquid medium: Tap taken from side of pipe to prevent air bubbles accumulating on measuring cell.

Gas medium: Tap taken from top of pipe to avoid liquid pooling on cell.

Avoid locations after pumps, valves and elbows with pressure spikes and high turbulence. Add snubber/damper under heavy vibration to protect ceramic cell.

  1. Piping Pre-treatment

Purge piping to remove metal chips and weld slag; debris can scratch ceramic diaphragm and cause zero drift.

  1. Sealing Parts Preparation

G1/4 is parallel pipe thread. Do NOT wrap large amount of PTFE tape. Copper gasket or O-ring is preferred. A small amount of thread sealant is allowed, but sealant must not squeeze into pressure chamber, which will permanently damage the cell.

  1. ツール: トルクレンチ, M12 pre-assembled cable, spanner.
  2. 機械的取り付け (Pressure Piping Connection)
  3. Align sensor G1/4 thread with pipe fitting, hand-tighten first. Do NOT use spanner on plastic display housing directly.
  4. Recommended tightening torque: 25~35 N·m. Must use torque wrench. Excessive torque causes housing deformation and ceramic cell cracking; insufficient torque causes leakage.
  5. Display Head Rotation: After tightening thread, the electronic display head can be rotated 345° for optimal viewing angle. Do not rotate beyond mechanical end stop, forced rotation damages internal wiring.

⚠️ Note: Rotate the upper display head, NOT the pressure thread base.

  1. インストール後, pressurize slowly and check thread for leakage.
  2. 電気配線 (M12 A-coded 5-pin)

Perform wiring with power OFF. IFM original M12 prefabricated cable recommended. M12 connector tightening torque: 0.6~1.2 Nm to maintain IP67.

ピン番号.ワイヤーの色意味備考
1BN BrownDC+ 18~30Vパワーポジティブ
2WH WhiteOUT1 (PNP switching output)Switch channel 1
3BU Blue直流- GNDパワーマイナス
4BK BlackOUT2 / IOリンクチャネル 2, IO-Link multiplex port
5Not usedSpare pin

出力: 2×PNP, max load current 250mA per channel.

IO-Link usage: ピン 4 for IO-Link communication.

Cable recommendation: 0.34~0.5mm². Route IO-Link wiring away from frequency converters and high-power power cables to reduce interference.

  1. パワーアップ & 試運転
  2. Double-check wiring for correctness and short circuit; fasten M12 connector.
  3. Apply DC24V power slowly, display lights up.
  4. Menu configuration: Set switch point SP, reset point rP, select window / hysteresis mode and pressure unit.
  5. Zero point verification: Confirm reading near 0 bar when piping is depressurized.
  6. Pressurize gradually, verify pressure reading and switch output actuation.
  7. IO-Link application: Import IODD file in PLC, identify device, read pressure, temperature and diagnostic parameters.
  8. Critical Installation Prohibitions (Engineering Key Points)
  9. ❌ Do NOT mount or demount sensor under pressure; high-pressure ejection may injure personnel and damage equipment.
  10. ❌ Do NOT use spanner on plastic display housing to tighten thread; only clamp lower metal thread base.
  11. ❌ Heavy PTFE tape on G1/4 thread; debris entering pressure chamber scratches ceramic cell.
  12. ❌ Over-tightening torque, may fracture ceramic measuring element.
  13. ❌ Direct medium impact above 80℃; add cooling buffer for high-temperature media.
  14. ❌ Operation under heavy shock and continuous vibration without snubber, leading to zero drift and shortened service life.
  15. ❌ Hot plug/unplug M12 connector, risk of burning output circuit.
  16. Post-installation Check List

No leakage at thread connection

M12 connector tightened, IP67 intact

電源電圧: 18~30V DC

No short circuit or reverse polarity

Zero reading normal with no applied pressure

Switch point action normal / IO-Link communication stable

  1. Replacement Hint for PN7292

Mechanical mounting, 糸, torque and M12 pinout are fully identical; piping and cables remain unchanged. Only IO-Link projects require IODD file update.

前へ:

次:

返信を残す

伝言を残す