Modicon TM2 Discrete Output Expansion Module, for M238 / M241 PLC, End of Life
Full designation: TM2DDO8TT, 8-point 24VDC Source (PNP) transistor output module, removable screw terminal block
- モデルコードの定義
TM2: TM2 series expansion I/O (Compatible with M218 / M238 / M241)
D: デジタル
する: デジタル出力
8: 8 チャンネル
T: トランジスタ
T: Source output (PNP); UT = Sink output (NPN)
- 主要な電気仕様
| アイテム | 仕様 |
| 出力タイプ | 24VDC PNP Source Transistor |
| チャンネル | 8 ポイント, shared 1 コモン端子 |
| Rated current per channel | 0.5A/点; Max total current of common terminal: 4あ |
| 動作電圧範囲 | 20.4 ~ 28.8 VDC |
| 応答時間 | 450µs (rise / fall) |
| Voltage drop | Max 0.4V |
| Leakage current | ≤0.1mA |
| Max inductive load | 10mH; Tungsten lamp load:12W |
| 保護 | Per-channel short-circuit & 過負荷保護, 自動回復 |
| 分離 | Channel ↔ PLC internal bus: 500Vac for 1min; No isolation between channels |
| ターミナル | Removable screw terminal block |
| 取り付け | 35mm DINレール |
| 重さ | 0.085kg |
| 寸法 | W27.3 × H90 × D84.6 mm |
- 互換性 & End-of-Life Information
- 対応CPU: Modicon M218 / M238 / M241 PLC (TM2 local expansion); Not applicable for M221/M251
- EOL Status: Officially discontinued by シュナイダー の上 27 Sep 2024. No new original units available, only stock / second-hand modules on market.
- 推奨代替品: TM3DQ8T (TM3 series, 8-point Source transistor output, compatible with M221/M241/M251)
⚠️ Note: TM2 and TM3 bus hardware are not interchangeable. Direct replacement requires PLC backplane / expansion architecture modification.
- Same Series Selection Reference
TM2DDO8TT: 8する, PNP Source, 0.5あ, ネジ端子 (EOL)
TM2DDO8UT: 8する, NPN Sink, 0.3あ, ネジ端子 (EOL)
- 応用 & 配線上の注意
- PNP Source Output: Output terminal provides +24V; negative side of load connects to 0V. Suitable for solenoid valves, インジケーターライト, load connected to 0V.
- 誘導負荷の場合 (電磁弁), freewheeling diode is recommended to protect transistors.
- TM2 expansion modules must be installed at the end of local expansion bus, cannot be placed before TM3 expansion modules.
- Onboard LED channel status indicators for commissioning and troubleshooting.
- 障害のトラブルシューティング (Second-hand Module Inspection)
- Power on and check module power LED and bus communication LED.
- Test each output channel sequentially: When PLC output = ON, measure 24V at terminal; voltage drops when OFF.
- Short-circuit protection test: Short output to 0V, channel should cut off output automatically; output recovers once short circuit removed.
- Measure off-state leakage current to judge transistor aging.
- Inspect removable terminals for burn marks and deformed copper contacts.
- HS Code Reference
8537101100 (Programmable Controller I/O Expansion Module)
Replacement Options for TM2DDO8TT (8-point 24VDC PNP Source, TM2 Bus)
Original module: TM2DDO8TT, TM2 bus, only for M218/M238/M241, EOL; TM2 bus and TM3 bus hardware cannot be swapped directly. 3 categories for selection:
場合 1: Keep existing M218/M238/M241 CPU, only replace expansion module
TM3 modules cannot be used. Although M241 supports both TM2+TM3 bus, TM2 modules must be installed after TM3 modules. Mixed installation is not recommended for long-term engineering use. If you need direct plug-in on TM2 expansion bus: only surplus / used TM2DDO8TT available. Schneider has no new equivalent module on TM2 bus.
Alternative spare within same EOL series: No other TM2 8-point Source DO. Only TM2DDO8UT (NPN Sink) 利用可能, cannot directly swap, opposite output logic.
場合 2: Full PLC Upgrade (Recommended for new project / major overhaul, official replacement: TM3 series)
✅ TM3DQ8T [Top Recommendation]
Spec: 8-point 24VDC PNP Source transistor, 0.5チャンネルごとに, removable screw terminal
Compare with TM2DDO8TT: Same channel count, output type and per-channel current; Bus type is TM3, not TM2
対応CPU: M221 / M241 / M251 / M262
Modification effort:
- Original M241: TM3 expansion bus supported, but IO address must be reconfigured in EcoStruxure Machine Expert, IO mapping modification required in program.
- Original M218/M238: Does not support TM3 modules, CPU must be upgraded to M241/M251 together.
Other TM3 Alternatives (Same TM3 Bus)
- TM3DQ8TG: 8-point PNP Source, スプリング端子, electrical parameters same as TM3DQ8T, only wiring terminal difference
- TM3DQ16T: 16-point PNP Source, 0.5あ; spare IO channels, suitable for projects with IO reservation
事例3: Distributed Remote IO Replacement (Keep original CPU, no local bus modification, ideal for legacy retrofit)
Advantys OTB remote IO, communicate via Modbus RTU to original PLC, independent IO station, does not occupy TM2 local expansion port
- OTB1C08T: 8-point 24V PNP Source transistor output, Modbus RTU, ネジ端子
Pros: No modification to original local expansion bus, only add Modbus read/write logic, independent installation inside cabinet. Suitable for limited cabinet space, no change to existing expansion chain.
Cons: Modbus communication program required, response speed slightly slower than local expansion module.
事例4: 国内互換の交換品 (Cost-saving option, Modbus Remote IO)
Domestic Modbus RTU remote 8-channel PNP transistor output modules (革新, Xinje, Lansen etc.), functionally equivalent, connect to M218/M238/M241 via Modbus. For projects with tight budget.
Selection Comparison Table
| 代替機種 | 出力タイプ | Current per Channel | Bus Type | 対応PLC | Modification Workload |
| TM2DDO8TT (オリジナル) | PNP Source | 0.5あ | TM2 Local Bus | M218/M238/M241 | EOL, only stock / used |
| TM3DQ8T (公式推奨) | PNP Source | 0.5あ | TM3 Local Bus | M241/M251/M221/M262 | ★★★☆ Reconfigure IO address & PLC program |
| OTB1C08T | PNP Source | 0.5あ | Modbus RTU Remote IO | M218/M238/M241 (No CPU change) | ★★☆ Add Modbus communication program |
⚠️ Critical Retrofit Notes
- TM2 bus and TM3 bus have different hardware connectors, cannot hot-swap directly. When mixing TM2+TM3 on M241, TM2 modules must be placed after TM3 modules; long-term mixed configuration is not recommended in engineering.
- TM2DDO8TT is PNP Source. Never select NPN Sink model (TM3DQ8U / TM2DDO8UT), opposite output logic, load will not operate after wiring.
- TM3DQ8T has different common terminal and pin assignment from TM2DDO8TT, field secondary wiring cannot reuse the original terminal plug directly; rewiring required.
Schneider TM3DQ8T (Common miswriting: TM3DO8T)
Modicon TM3 discrete expansion output module, 8-point 24VDC PNP Source transistor output, removable screw terminal, official recommended replacement for TM2DDO8TT
- モデルコードの定義
TM3: TM3 series local expansion I/O module
DQ: Discrete Output
8: 8 チャンネル
T: Transistor PNP Source output (ネジ端子)
TM3DQ8TG = identical electrical parameters, spring cage terminal version
- コアの電気仕様
| アイテム | 仕様 |
| 出力タイプ | 24VDC PNP Source (正論理) トランジスタ |
| チャネル数量 | 8 ポイント, shared one common terminal |
| Rated current per channel | 0.5A/channel |
| Max total current of common terminal | 4あ (Total limit for 8 チャンネル) |
| Output supply voltage | 20.4 ~ 28.8 VDC (公称DC24V) |
| Voltage drop | ≤0.4V |
| Off-state leakage current | ≤0.1mA |
| 応答時間 | Max 450µs (rise / fall) |
| Max switching frequency (抵抗負荷) | 100Hz |
| Max incandescent lamp load | 12W |
| Inductive load | External freewheeling diode recommended; typical clamping voltage 50VDC |
| 短絡保護 | Per-channel independent short-circuit / 過負荷保護; auto-recovery after fault removal |
| Isolation rating | Module bus ↔ output channel: 500Vac, 1min withstand; No isolation between channels |
| Bus power supply | 5V supplied by TM3 expansion bus; 24V for output loop must be wired separately |
| 5V bus consumption | オフ:5ミリアンペア; の上:10ミリアンペア; 24V field circuit: OFF=0mA, ON max 20mA |
- 機械式 & 環境仕様
| アイテム | 仕様 |
| 取り付け | 35mm DIN rail TH35-7.5 / TH35-15, or panel screw mounting |
| Overall dimension | W27.4 × H90 × D84.6 mm |
| 正味重量 | 約. 0.076kg |
| 保護クラス | IP20 (For cabinet installation only) |
| ターミナル | Removable screw terminal block, 5.08mm pitch; ワイヤー:0.2~2.5mm² (24~14AWG) |
| 動作温度 | 水平取付: -10 ~+55℃; 垂直取り付け: -10 ~ +35℃ |
| 保管温度 | -25 ~ +70℃ |
| 相対湿度 | 10~95%, 結露しないこと |
| Max working altitude | 2000メートル |
| 汚染度 | 2 |
| 耐振動性 | 5~8.4Hz:3.5mm; 8.4~150Hz:3g |
| 耐衝撃性 | 15g,11MS |
| インジケータLED | 1 green LED per channel to display ON/OFF state |
| 認証 | CE, cULus, UKCA, RCM, CCC |
- PLC Compatibility
Works with Modicon M221 / M241 / M251 / M262
❗ M218, M238 do NOT support TM3 modules, cannot extend TM3DQ8T directly.
- Comparison vs Original TM2DDO8TT (鍵)
| パラメータ | TM2DDO8TT | TM3DQ8T |
| 出力 | PNP Source 0.5A, 8-point common terminal | PNP Source 0.5A, 8-point common terminal |
| Max total common current | 4あ | 4あ |
| 応答時間 | 450碌s | 450碌s |
| Withstand isolation | 500Vac | 500Vac |
| バス | TM2 Bus (M218/M238/M241) | TM3 Bus (M221/M241/M251/M262) |
| 寸法 | W27.3 脳 H90 脳 D84.6mm | W27.4 脳 H90 脳 D84.6mm |
| 端子配置 | Different pin assignment, secondary wiring cannot reuse terminal plug directly | Different pin assignment, secondary wiring cannot reuse terminal plug directly |
- 配線上の注意
- PNP Source: Output terminal provides +24V, load other end connects to 0V; suitable for solenoid valves and indicator lamps.
- 8 channels share one common power terminal, external +24V connects to common terminal.
- 誘導負荷の場合 (電磁弁), freewheeling diode must be paralleled to absorb back EMF and protect transistors.
- Module 5V bus power supplied by PLC backplane; 24V power for output circuit must be external.
- Fault Detection (Bench Test)
- 電源を入れる: Check module bus LED and channel LED status.
- Activate each point sequentially: 24V measured at terminal when ON; voltage drops at OFF state.
- Short-circuit test: Short output to 0V, module triggers protection, output restores automatically after short removed.
- Measure off-state leakage current to evaluate transistor aging.
- HS Code Reference
8537101100 (PLC discrete I/O expansion module)
- Alternatives within TM3 family
TM3DQ8TG: Same specs, spring cage terminal
TM3DQ8U: 8-point NPN Sink output, opposite logic, do not select by mistake
コンタクタ,サーキットブレーカー,センサー,エンコーダ,PLC,コンバータ















NH42-63-318x560.png)