카를로 가바치 VNY 4 NS/NT Conductive Level Sensor (Item No.: 481046)
| 모델 세그먼트 | 설명 |
| VNY | 제품 시리즈: Conductive level probe; VNY series features threaded connection with PBTP housing and non-insulated electrodes |
| 4 | Electrode quantity: 4 electrodes, supporting multi-level monitoring (높은 / 중간 / 낮은 / Ultra-low) |
| NS | Electrode type: Non-Isolated, suitable for general conductive liquid measurement |
| NT | 연결 유형: 나사 터미널, convenient for field wiring |
| 481046 | Global unique item / 주문 번호, official Carlo Gavazzi part identifier |
- Full Core Technical Specifications
| 매개변수 카테고리 | 명세서 | 비고 |
| 기본 정보 | Conductive level sensor for multi-point level control of conductive liquids | Must be used with amplifier relays (SV series, S195/196, ELA/ELC/ELD) |
| 주문 번호. | 481046 (corresponds to model VNY 4 NS/NT) | Order strictly by this part number |
| 제조업체 | 카를로 가바치 | Well-known brand in industrial automation sensors |
| Electrode Configuration | 4 non-insulated electrodes, AISI316 stainless steel (DIN1.4401) | Diameter 5mm, standard length 100cm (field-cuttable) |
| 하우징 재질 | PBTP engineering plastic | Corrosion-resistant for industrial environments |
| 장착 유형 | 1 1/2″ pipe thread (ISO 228/1-G1 1/2″) | Standard industrial pipeline mounting, fixed with VM15 nut |
| 연결 방법 | Screw terminal connection (NT) | More suitable for vibrating environments than cable connection, 쉬운 유지 보수 |
| 유입 방지 | IP67 | Dust-tight and waterproof, submersible in liquid |
| 작동 온도 | 0°C ~ 90°C (32°F ~ 194°F) | Compatible with most industrial liquid temperature ranges |
| 보관 온도 | -25°C ~ 100°C (-13°F ~ 212°F) | Adaptable to extreme transportation and storage conditions |
| 작동 압력 | 10 술집 (@ 60°C) | Suitable for medium and high-pressure tank applications |
| 케이블 사양 | No built-in cable (screw terminal type) | Customer-supplied cable recommended; shielded cable preferred to reduce interference |
| 인증 | CE certified (IEC를 준수 529) | Meets EU industrial safety requirements |
| 치수 | Electrode diameter 5mm, total length approx. 100cm | Electrode length can be cut on-site according to actual liquid level |
| 무게 | 대략. 0.8kg | Lightweight design for easy installation and maintenance |
- VNY Series Full Model List
| Item No. | 모델 | Electrode Qty | Electrode Type | 연결 유형 | 하우징 재질 | Mounting Thread | 특별한 기능 |
| 481046 | VNY 4 NS/NT | 4 | Non-Isolated (NS) | 나사식 터미널 (NT) | PBTP | 1 1/2″ | Multi-level control, general industrial use |
| 481043 | VNY 1 NS/NT | 1 | Non-Isolated (NS) | 나사식 터미널 (NT) | PBTP | 1 1/2″ | Single-point level detection, 비용 효율적 |
| 481044 | VNY 2 NS/NT | 2 | Non-Isolated (NS) | 나사식 터미널 (NT) | PBTP | 1 1/2″ | Two-point high/low level control |
| 481045 | VNY 3 NS/NT | 3 | Non-Isolated (NS) | 나사식 터미널 (NT) | PBTP | 1 1/2″ | Three-point high/medium/low level control |
| 481047 | VNYI 4 IS/NT | 4 | Insulated (IS) | 나사식 터미널 (NT) | PBTP | 1 1/2″ | PE insulated electrodes, anti-clinging liquid interference |
| 481042 | VNY 1 NS/CB | 1 | Non-Isolated (NS) | Cable Connection (CB) | PBTP | 1 1/2″ | 2m fixed cable length, suitable for long-distance installation |
- 대사 & Cross Reference
4.1 동일 브랜드 직접 교체
| 원래 모델 | 교체 모델 | 교체 설명 | 응용 시나리오 |
| VNY 4 NS/NT (481046) | VNYI 4 IS/NT | Upgraded insulated electrodes to avoid false triggering from liquid clinging | Viscous liquids and wall-adhering media (syrup, lubricating oil) |
| VNY 4 NS/NT (481046) | VNY 4 NS/CB | Changed to cable connection for heavy vibration environments | Level monitoring for vibrating equipment such as pump sets and compressors |
| VNY 4 NS/NT (481046) | VN 4 NS/CB | Cable type with PBTP housing and 1 1/2″ thread | General industrial environments, better cost performance |
4.2 브랜드 간 동등한 모델
| 카를로 가바치 | 슈나이더 | 옴론 | 페펄+푹스 | 주요 차이점 |
| VNY 4 NS/NT (481046) | XPSAK3711 | D4CC-4000 | FTL20-0020 | Carlo Gavazzi adopts superior AISI316 material with IP67 protection |
| Schneider higher integration; Omron more cost-competitive | ||||
| Field-cuttable electrode length for better adaptability | ||||
| Pepperl+Fuchs suitable for explosion-proof areas; Carlo Gavazzi for general industry |
- Application Industries & 일반적인 경우
권장 애플리케이션
- Process Industry: Tank level monitoring in chemical, petrochemical and pharmaceutical industries to prevent overflow and dry running
- 음식 & 음료: Raw material and finished tank level control for beer, beverage and dairy production lines
- 수처리: Level monitoring for sedimentation tanks and reaction tanks in waterworks and wastewater plants
- Energy Sector: Level protection for cooling and lubrication systems in power plants and substations
- Mechanical Manufacturing: Oil level monitoring for hydraulic and lubrication systems to avoid equipment damage
- 해양산업: Level measurement for ship ballast tanks, fuel tanks and fresh water tanks
일반적인 적용 사례
- Chemical Plant Acid & Alkali Tank Level Control System
Application Goal: Monitor high/low levels of three 100m³ acid and alkali tanks to prevent overflow and pump dry running
핵심 장점: AISI316 corrosion-resistant electrodes; IP67 suitable for outdoor installation; 4-electrode enables multi-point level monitoring
시스템 구성: VNY 4 NS/NT (481046) × 3 + ELA amplifier relay + PLC control system + HMI touch screen
Operation Effect: Level control accuracy ±1cm, false alarm rate reduced by 95%, maintenance cost cut by 60%
- Automobile Factory Hydraulic Station Oil Level Monitoring System
Application Goal: Monitor oil levels of 5 hydraulic stations to ensure stable operation and prevent oil shortage failure
핵심 장점: Vibration-resistant screw terminal design; oil-resistant PBTP housing; field-cuttable electrodes adaptable to various tank heights
시스템 구성: VNY 4 NS/NT (481046) × 5 + S196 amplifier + indicator light + buzzer
Operation Effect: Equipment failure rate reduced by 40%, maintenance cycle doubled
Not Recommended Applications
Non-conductive liquids: Such as pure oil, alcohol, acetone; not detectable by conductive sensors
고온 >90℃: Adopt VPP series (up to 100°C) or high-temperature versions
Working pressure >10 술집: Special high-pressure level sensor required
Strong corrosive media: Concentrated hydrochloric acid, concentrated sulfuric acid; use VPP series with PVDF electrodes or anti-corrosion coated models
- 설치 & 배선 지침
설치 요구 사항
- 장착 위치: Install on tank top or side, away from inlet ports and agitators; ensure vertical electrode immersion
- Electrode Cutting: Cut electrode length on-site according to actual liquid level; deburr the end after cutting for accuracy
- 씰링: Use suitable gaskets (PTFE recommended) for leak-tight installation to maintain IP67 protection
- Earthing Requirement: Conductive tank body can serve as common electrode; non-conductive tanks require separate common electrode grounding
- 간격 요구 사항: Keep ≥50mm between electrodes and between electrodes and tank wall to avoid signal interference
핵심 터미널 정의
| 터미널 번호. | 기능 | 유형 | 비고 |
| E1/E2/E3/E4 | Electrode 1–4 | Signal Input | Correspond to four level detection points; freely assign high/medium/low functions |
| COM | Common Terminal | Signal Reference | Connect to tank wall or separate common electrode to complete circuit |
| +V/-V | 전원공급장치 | 24VDC | Requires matching amplifier relay; sensor itself needs no independent power supply |
| NO/NC/COM | 릴레이 출력 | Switch Contact | Provided by amplifier relay for valve control or alarm output |
시운전 핵심 사항
- Electrode Setting: Define corresponding level heights for each electrode (예를 들어. E1=Low, E2=Medium, E3=High, E4=Ultra-high)
- 감도 조정: Adjust amplifier relay sensitivity to avoid false triggering caused by foam or clinging liquid
- 기능 테스트: Simulate level changes to verify accurate switching action and response time
- Insulation Check: For non-insulated type, ensure no short circuit between electrodes and tank wall; check insulation integrity for insulated type
- Environmental Adaptation Test: Verify long-term stability within rated temperature and pressure range
- 선택 규칙 & 빠른 참조
선택 지침
- Liquid Type: Choose VNY series for conductive liquids; use capacitive or ultrasonic sensors for non-conductive liquids
- Electrode Quantity: 1=single point, 2=high/low, 3=high/medium/low, 4=four-point full control
- Electrode Insulation: NS for normal liquids; IS insulated type for viscous wall-adhering media
- 연결 유형: NT screw terminal for vibration environments; CB cable type for long-distance installation
- Mounting Thread: 1 1/2″ for large tanks, 1″ for medium, 1/2″ for small containers
- 온도 & Pressure: VNY for 0–90°C / 10 술집; VPP for higher temperature; special models for higher pressure
- 항공 화물 규정 준수 & 인증
항공 화물 규정 준수: 리튬 배터리 없음 / 슈퍼커패시터. Pure mechanical and metallic structure, IATA DGR 클래스 준수 9, shippable as standard general cargo.
인증:
– CE: IEC를 준수 529 ingress protection standard
– RoHS 규제: EU RoHS 준수, 유해 중금속이 없음
– Material Certification: AISI316 stainless steel electrodes meet food-contact grade requirements for food & beverage industry
환경 준수: Compliant with REACH regulations for global market access
- 구매 & 물류정보
| Purchase Item | 세부 |
| MOQ | 1 단위 |
| 리드타임 | Standard 5–7 days; Express 2–3 days |
| 포장 | Individual carton with installation manual, sealing gasket and mounting nut |
| 보증 | 12 months from commissioning acceptance |
| 권장 예비품 | Same model sensor, electrode extension joint (VD1), mounting nut (VM15) |
| 어울리는 액세서리 | Carlo Gavazzi ELA/ELC/ELD amplifier relay, PLC, HMI touch screen |
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지