Mitsubishi AJ65SBTB1-32D Compact Remote Input Module

AJ65SBTB1-32D is a Mitsubishi MELSEC CC-Link compact remote DC digital input module Model Code Definition AJ65: CC-Link remote I/O module series SBTB1: Compact remote I/O main body 32: 32 I/O points D: 디지털 입력 (DC 입력) Key Specifications Item Parameter Network CC-Link Ver.1/2 Type Remote DC digital input module Points 32 input points Occupied stations ...

  • 제품 세부정보

AJ65SBTB1-32D is a 미쓰비시 MELSEC CC-Link compact remote DC digital input module

  1. 모델 코드 정의

AJ65: CC-Link remote I/O module series

SBTB1: Compact remote I/O main body

32: 32 I/O 포인트

디: 디지털 입력 (DC 입력)

  1. 주요 사양
목매개변수
회로망CC-Link Ver.1/2
유형Remote DC digital input module
전철기32 입력 포인트
Occupied stations1 station
Rated input voltageDC24V
입력 전류대략. 7포인트당 mA
Input response time1.5ms (끄기→켜기 / 켜기→끄기)
Input polarity싱크/소스 호환 (works with both NPN and PNP sensors)
격리광커플러 절연
모듈 전원 공급 장치DC24V; Module power consumption approx. 45엄마
ON threshold≥14VDC / ≥3.5mA
OFF threshold≤6VDC / 1.7mA 이하
전체 치수W179 × H50 × D40 mm
무게0.25 kg
터미널M3 screw terminal block
보호 등급IP2X
  1. 응용 시나리오

Remote sensor signal acquisition for production lines: 광전 센서, proximity switches, magnetic switches, pushbutton signals

Distributed I/O architecture to reduce bulk hardwiring from control cabinets to field devices via CC-Link bus networking

Compatible with Mitsubishi Q-series, FX3U/FX5U PLCs equipped with CC-Link master station

  1. 모델 구별 (Frequently Confused Models)
  2. AJ65SBTB1-32D: 표준 버전, 1.5ms 응답, 32에서
  3. AJ65SBTB1-32D1: High-speed version, 0.2ms 응답, 32에서, preferred for high-frequency sensors
  4. AJ65SBTB1-32T: 32-point transistor output module
  5. AJ65SBTB1-32DT: 16-input +16-output mixed I/O module

Lifecycle note: AJ65SBTB1-32D is discontinued. Only stock or used units available. 새로운 프로젝트의 경우, AJ65SBTB1-32D1 is the preferred replacement. Same mounting dimensions and terminal definitions; only faster response speed, no program modification required.

  1. 설치 & 배선 지침
  2. 전원공급장치: Independent DC24V supply for module itself; sensors also use DC24V signal
  3. CC-링크 버스: DA/DB cables; 110Ω terminating resistors fitted at both ends of the bus
  4. Common terminals: 8 points per common group, supports NPN/PNP. Keep unified polarity during wiring
  5. 접지: Reliable earthing on FG terminal to reduce bus interference
  6. Station number setting: DIP switches on module body to set CC-Link station number
  7. 일반적인 오류 문제 해결
  8. RUN indicator off: Check DC24V supply, polarity and internal fuse
  9. ERR indicator flashing: CC-Link communication failure. Inspect DA/DB wiring, terminating resistors, duplicate station numbers, shield earthing
  10. No signal at input channel: Verify sensor power supply and common polarity; measure terminal voltage with multimeter; check for damaged optocoupler channel
  11. 잘못된 신호 트리거링: Cable interference, use shielded cable; check response time. 긴 케이블용, select D1 high-speed variant
  12. Alternative Selection List
  13. 직접 드롭인 교체 (같은 크기 & 터미널): AJ65SBTB1-32D1 (새로운 프로젝트에 권장)
  14. Domestic compatible CC-Link 32DI remote I/O: 혁신, Inwell CC-Link remote input modules (verify CC-Link version and register mapping)
  15. Upgrade to CC-Link IE Field bus: NZ-series remote I/O (hardware architecture completely different; PLC program rewrite required)
  16. HS Code Reference

8537101100 (Programmable controller digital input module, for customs declaration only; subject to customs final judgement)

CC-Link Master Station Parameter Configuration (for AJ65SBTB1-32D, 리모트 I/O 스테이션, 차지하다 1 station)

Master module: QJ61BT11N (Q-series); Programming software: GX 웍스2; AJ65SBTB1-32D = Remote I/O Station, 차지하다 1 station, 32-point RX input, no RY output and no RW registers.

Master station fixed station number: Station 0. Slave AJ65SBTB1-32D station number set via DIP switch: 1~64. Station 1 is used in this example.

  1. Hardware DIP Switch (Set AJ65SBTB1-32D first!)
  2. Station number DIP switch: Binary DIP switch for station address (예를 들어. Station 1 = 00000001)
  3. Baud rate DIP switch: Must match master station baud rate

000 → 156kbps

001 → 625kbps

010 → 2.5Mbps (most commonly used on site)

011 → 5Mbps

100 →10Mbps

Fit 110Ω terminating resistors at both ends of the bus

  1. GX Works2 Q-series CC-Link Master Basic Parameters

Path: Project Navigator → Parameters → Network Parameters → CC-Link

목Setting Value비고
모듈 모델QJ61BT11NMaster station module
Start I/O Address0000 (modify according to actual slot)Module I/O address
Master Station No.0CC-Link master fixed at station 0
방법Remote Net(Ver.1 Mode)AJ65SBTB1-32D is Ver.1 compatible remote I/O
총 연결 스테이션1For single AJ65SBTB1-32D network; update for multiple slaves
Communication Speed2.5MbpsMust match slave DIP baud rate
Retry Count3기본
Standby Master없음Standard single-master system
Scan Mode비동기식기본

Station Information (비판적인!)

Click [Station Information], add Station No.1:

목환경
역 번호.1DIP station number of AJ65SBTB1-32D
스테이션 유형리모트 I/O 스테이션⚠️ NOT Remote Device Station!
Occupied Stations1AJ65SBTB1-32D fixed as 1 station
RX(Remote Input)32 전철기X0~X1F (corresponds to 32DI)
RY(Remote Output)0 전철기This module has inputs only, no outputs
RWw/RWr0 단어Remote I/O stations do not use registers

Remote I/O station soft element mapping rule:

Station1: RX0~RX1F correspond to the 32 DI channels of AJ65SBTB1-32D

PLC internal soft elements for master station: RX mapped to PLC X addresses (auto-refreshed by GX Works)

  1. Soft Element Refresh Mapping (QJ61BT11N)

CC-Link automatic refresh:

RX: Remote input → PLC internal X

RY: PLC output → Remote module output

RWw: PLC writes to remote registers

RWr: Remote registers read into PLC

AJ65SBTB1-32D (Station 1)

RX0~RX1F (32조금) = 32 DC input channels of the module

예: Sensor ON → RXn=ON; read RX bit directly in program.

  1. FX5U + FX5-CCL-MS (FX5U CC-Link Master, GX Works2/3)

FX5U with FX5-CCL-MS master card can connect AJ65SBTB1-32D

  1. Project → Parameters → CC-Link Parameters, Master type: Master station, Ver.1 mode
  2. Add station entry for Station 1: 리모트 I/O 스테이션, 차지하다 1 station, RX=32, RY=0
  3. Soft element refresh: RX mapped to FX5U X or M (customizable refresh address)

FX5U built-in Ethernet CC-Link IE Field Basic cannot directly connect old AJ65SBTB1-32D. This classic CC-Link uses RS485 bus and requires FX5-CCL-MS module.

  1. 다운로드 & 시운전 단계
  2. Complete all parameter settings, 딸깍 하는 소리 [확인하다], confirm no errors;
  3. Write [매개변수 + Program] to PLC; PLC reset;
  4. Power up remote modules with DC24V first, then power up PLC master station;
  5. Observe indicators:

M/S: Master steady ON; 달리다: Slave steady ON;

ERR off = Communication normal; ERR flashing = bus fault;

  1. Online monitor RX soft elements; trigger sensors and verify corresponding RX bits turn ON/OFF.
  2. 일반적인 실수
  3. ❌ Wrong station type: selected as Remote Device Station → communication failure; must use Remote I/O Station
  4. ❌ Baud rate mismatch between master and slave
  5. ❌ Missing terminating resistors, random disconnection over long cables
  6. ❌ Duplicate station numbers, frequent in multi-slave networks
  7. ❌ Ver.2 mode enabled; old AJ65SBTB1-32D is Ver.1 compatible, use Remote Net Ver.1 Mode by priority
  8. Sample Program (성 / Ladder compatible)

Directly monitor RX0~RX1F, no special communication instruction required, CC-Link auto cyclic refresh.

예: LD RX0 reads channel 0 input of AJ65SBTB1-32D.

Optional extensions available upon request:

  1. Screenshot-style GX Works2 CC-Link parameter setup guide
  2. Batch parameters for multiple AJ65SBTB1-32D network (Station1, Station2, Station3…)
  3. Communication fault code (ERR lamp) reference table
  4. Ladder example to map RX to internal M relays for easier programming

CC-Link ERR Lamp + QJ61BT11N Fault Code Reference Table (For AJ65SBTB1-32D)

Two sections: Quick LED Indicator Diagnosis (On-site check) + Hex Fault Codes read from GX Works Diagnosis (Precise troubleshooting)

주인: QJ61BT11N; 노예: AJ65SBTB1-32D

  1. LED Status Quick Reference (Master QJ61BT11N ERR Lamp)
Master ERR Lamp오류 설명문제 해결
끄다통신 정상–
계속 켜져 있음All stations communication failureBus breakage, DA/DB reversed, dual master conflict, parameter error, baud mismatch, missing terminating resistor
섬광Partial slave fault, faulty station existsSingle/multiple slave offline, duplicate station number, slave power off, slave hardware damage

Slave AJ65SBTB1-32D L.ERR Indicator

Slave L.ERR Lamp오류 설명문제 해결
끄다통신 정상–
계속 켜져 있음Slave communication errorStation number out of range, bus broken, power supply abnormal
Regular periodic flashingDIP switch modified under power (station/baud)전원 끄기, reset DIP switch, repower
Irregular random flashingNoise interference / faulty terminating resistor110惟 resistors at both bus ends, shield earthing, 케이블 손상, parallel power cable interference

PW lamp OFF: No DC24V supply to slave, check power terminals and fuse first.

L.RUN lamp OFF: Data link not established; master cannot detect this slave station.

  1. QJ61BT11N Master Hex Fault Codes (Read via GX Works CC-Link Diagnosis)
오류 코드(HEX)Fault Name원인행동
B823Remote control mode errorIncorrect master mode settingSet network parameter to Remote Net(Ver.1 Mode). AJ65SBTB1-32D does not support Ver.2 extended mode
B983 / B984Invalid module typeMode incompatibility between master and slaveOld AJ65SBTB1-32D is Ver.1 remote I/O; disable Ver.2 mode
BA1BAll stations failureWhole bus communication interruptionDA/DB wiring, 110惟 terminators, 전송 속도, cable breakage
BBC2Station number setting errorStation number out of range or wrong station typeStation type must be [리모트 I/O 스테이션], not Remote Device Station; station range 1~64
BBC5Duplicate master station (multi-master conflict)2 masters on the same CC-Link busCheck bus and keep only one master module
BD85Master hardware failureQJ61BT11N module damagePower cycle, replace master module if fault persists
BFFECPU watchdog timeoutCommunication error between PLC CPU and master moduleCheck QCPU backplane, 모듈 설치, PLC reset
C92EBaud rate mismatchMaster baud differs from slave DIP settingSet master baud equal to AJ65SBTB1-32D DIP baud
C932Duplicate station number conflictTwo slaves with identical station DIP settingCheck each module DIP and assign unique station number
C940Data link stopBus break / interference / missing terminatorCheck DA DB wiring, shield earthing, terminating resistors
  1. Q-series CC-Link Special Relay SW (Monitor in GX Works)

Identify offline station quickly via SW registers

  1. SW0080~SW0083: Link error bits, bit maps to station number. ON = fault at that station

SW0080 bit0 = Station1 fault; bit1 = Station2 fault, and so on

  1. SW006B: Detailed error type

0: 정상

1: Transmission line fault

2: Parameter error

3: CRC error (전자기 간섭)

4: Timeout error (slave no response)

5: Abort error

6: Setting error

  1. On-site Troubleshooting Sequence (AJ65SBTB1-32D)
  2. Check slave PW lamp: OFF → inspect DC24V supply
  3. Check slave L.RUN / L.ERR lamp
  4. Open GX Works → CC-Link Diagnosis, read fault code + SW0080 to locate faulty station
  5. Verify: station number, 전송 속도, station type (리모트 I/O 스테이션)
  6. Check DA/DB polarity, 110Ω terminators at both bus ends
  7. Single-point earthing for shield; avoid both-end earthing to prevent ground loop
  8. Separate CC-Link cable away from power cables to reduce interference
  9. Common Pitfall Summary
  10. Remote I/O Station mistakenly selected as Remote Device Station → BBC2 station type error, ERR flashing
  11. Master Ver.2 mode enabled, old AJ65SBTB1-32D incompatible → B983 invalid module type
  12. Terminating resistor fitted only on one end → random flashing, intermittent disconnection
  13. DA DB wires reversed, entire bus down, master ERR steady ON
  14. Modify DIP switches while powered on, slave L.ERR flashes periodically; power cycle to recover

Mitsubishi AJ65SBTB1 Series (CC-Link Compact Remote I/O, Screw Terminal Block, all discontinued, 1 station occupancy)

Suffix definition

디: DC Digital Input; D1: High-speed Input; D5: 5V Input

티: Sink transistor output; T1: High-speed transistor output; TE1: Source transistor output

DT: Mixed Input+Output; 케이: Special common terminal specification

All modules in this series are Remote I/O Stations (not Remote Device Stations), CC-Link Ver.1 compatible

  1. Pure DC Input Modules (에서)
모델전철기Brief Specification
AJ65SBTB1-8D8에서DC24V, standard response 1.5ms, NPN/PNP common terminal
AJ65SBTB1-16D16에서DC24V, standard response 1.5ms
AJ65SBTB1-16D116에서DC24V, high-speed 0.2ms
AJ65SBTB1-32D32에서DC24V, standard response 1.5ms (your target model)
AJ65SBTB1-32D132에서DC24V, high-speed 0.2ms, direct compatible replacement for 32D
AJ65SBTB1-32D532에서DC5V input, special signal acquisition for legacy projects
AJ65SBTB1-32KD32에서DC24V, special common terminal layout
  1. Pure Transistor Output Modules (~하다)
모델전철기Brief Specification
AJ65SBTB1-8T8~하다DC24V sink transistor, 0.5A per point
AJ65SBTB1-8T18~하다High-speed sink transistor output
AJ65SBTB1-8TE8~하다Source transistor output
AJ65SBTB1-16T16~하다DC24V sink transistor
AJ65SBTB1-16T116~하다High-speed sink transistor output
AJ65SBTB1-32T32~하다DC24V sink transistor output
AJ65SBTB1-32T132~하다High-speed sink transistor output
AJ65SBTB1-32TE132~하다Source transistor output
  1. Mixed I/O Modules (DI+DO)
모델I/O 구성Brief Specification
AJ65SBTB1-16DT8D+8CDC24V 입력 + sink transistor output
AJ65SBTB1-16DT18D+8CHigh-speed version
AJ65SBTB1-16DT28D+8CPositive common version
AJ65SBTB1-16DT38D+8CNegative common version
AJ65SBTB1-32DT16D+16C16-in 16-out, 표준 모델
AJ65SBTB1-32DT216D+16CRevised common terminal spec
AJ65SBTB1-32DT316D+16CImproved revision
AJ65SBTB1-32DTE116D+16CSource transistor output
AJ65SBTB1-32KDT216D+16CSpecial common terminal
AJ65SBTB1-32KDT816D+16C12V I/O, special legacy project

Distinguish other family series (AJ65SBTB2 / AJ65SBTB32 / AJ65SBTC connector type, NOT SBTB1 series)

Frequently confused during procurement, not part of SBTB1 series, reference only

  1. AJ65SBTB2: Relay output R, analog A modules

AJ65SBTB2-8R, AJ65SBTB2-16R (릴레이 출력); AJ65SBTB2-8A, 16A analog

  1. AJ65SBTB32: Compact small terminal block

AJ65SBTB32-8DT / 8DT2, AJ65SBTB32-16DT / 16DT2, AJ65SBTB32-16DR (mixed relay)

  1. AJ65SBTC: 퀵 커넥터 유형 (not screw terminals)

AJ65SBTC1-32D, AJ65SBTC1-32T, AJ65SBTC1-32DT, field plug wiring, different form factor from SBTB1

선택 참고 사항

  1. All AJ65SBTB1 series are discontinued. Not available for new project purchase, only stock / used units.
  2. 동일한 장착 치수: same point count D/D1, T/T1, DT/DT modules support direct drop-in replacement with no program modification.
  3. Station type: Must select [리모트 I/O 스테이션] in GX Works parameter; 결정된 1 occupied station.
  4. Analog modules are not in SBTB1 series: models AJ65SBT-64AD, AJ65SBT2B-64AD etc.