OMRON E5EC-QR2ASM-820 Controller - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

 OMRON E5EC-QR2ASM-820 Controller - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

전기 계량기/

OMRON E5EC-QR2ASM-820 Controller

Model Code Breakdown E5EC QR 2 A S M 820 E5EC: 시리즈, DIN panel mount digital PID temperature controller, 차원 48 mm(시간) × 96 mm(여) QR: Dual control outputs Q: OUT1 = Voltage pulse output (DC12V, for SSR drive) 아르 자형: OUT2 = SPST relay contact output (1에이) ✅ Supports Heating + Cooling dual control 2: ...

  • 제품 세부정보

모델 코드 분석

E5EC QR 2 A S M 820

  1. E5EC: 시리즈, DIN panel mount digital PID temperature controller, 차원 48 mm(시간) × 96 mm(여)
  2. QR: Dual control outputs

큐: OUT1 = Voltage pulse output (DC12V, for SSR drive)

아르 자형: OUT2 = SPST relay contact output (1에이)

✅ Supports Heating + Cooling dual control

  1. 2: 2 auxiliary alarm outputs
  2. 에이: Power supply AC 100~240 V (50/60 헤르츠)
  3. 에스: 나사식 터미널 블록
  4. 중: 범용 다중 입력

Supports K/J/T/S/R/B/N thermocouples, Pt100/Pt1000 RTD, 4~20 mA / 0~10 V analog signal

  1. 820: Function option code

Built-in RS485 Modbus communication

No heater burnout detection (CT 입력), no external event input

구별:

800 = No communication; 820 = With RS485; 808/828 = With CT heater current detection

  1. 주요 전기 사양
사양
전반적인 차원48(시간) × 96(여) × 60(디) mm, panel embedded mounting
전원공급장치AC100~240 V, 대략적인 전력 소비. 6.6 버지니아
제어 출력 1(큐)DC12V±20%, 최대. 21 mA PNP, SSR driving output
제어 출력 2(아르 자형)SPST relay 1a, AC250 V 5 에이 (저항 부하)
Auxiliary Outputs2 릴레이 출력 (for alarm, high/low limit, deviation alarm)
Sampling Cycle50 ms, high-speed PID calculation
제어 모드Standard PID, 자동 튜닝 (AT), ON/OFF control, 난방 & Cooling control
의사소통Modbus RTU over RS485 (Standard for suffix -820)
Input AccuracyRTD: ±0.2%FS; 열전대: ±0.3%FS
운영 환경0~50°C, 결로가 없을 것, non-corrosive atmosphere
  1. Simplified Terminal Definition

1, 2: AC Power Input

3, 4: OUT1 SSR voltage drive output

5, 6: OUT2 Relay control output

7, 8 / 9, 10: Two groups of auxiliary alarm outputs

Sensor terminals: Universal connection for thermocouple / Pt100 RTD

  1. 일반적인 애플리케이션 시나리오

Mold Temperature Controllers (TCU), Hot Air Ovens, Industrial Ovens, extruder heating & cooling control

Applications requiring SSR for heating + relay for cooling fan / cooling water valve

Automated production lines where PLC reads temperature and writes setpoint via RS485

  1. Cross-Series Alternative Models

E5EC-QR2ASM-800: RS485 통신 없음 (hardware identical otherwise)

E5EC-RR2ASM-820: Dual relay outputs, not suitable for high-frequency SSR control

E5EC-QX2ASM-820: Second output is 4~20 mA linear analog output

  1. 선택 & 조작상의 주의사항
  2. QR configuration is ideal: SSR for heating, relay for cooling loads;
  3. Relay output is NOT suitable for frequent switching (contact burnout risk); high-frequency loads must adopt Q voltage pulse output;
  4. Do not reverse A/B polarity of RS485 wiring; terminate resistor can be installed on demand;
  5. When enabling heating/cooling function, activate 2-PID heating-cooling control in parameters.

Practical Application Cases for OMRON E5EC-QR2ASM-820 Temperature Controller

Recap of core hardware strengths for this model:

✅ OUT1: DC12V voltage pulse output (drives SSR, suitable for high-frequency heating)

✅ OUT2: Relay contact output (drives fan / cooling water valve for cooling control)

✅ 2 independent alarm relay outputs

✅ Built-in RS485 Modbus-RTU (접미사 -820)

✅ Universal input: Pt100 RTD, K/J/T thermocouple, 4~20 mA analog signal

👉 Best fit: 난방 & Cooling 2-PID control + PLC network communication

사례 1: Injection Mold Temperature Controller (Most Common Industry Solution)

Working Requirements

Stable mold temperature 40~120°C; cooling water valve activates above set temperature, electric heater turns on below set temperature; PLC remotely reads process temperature & 설정값; overtemperature alarm.

Hardware Layout

감지기: Immersion Pt100 RTD

OUT1(큐) → SSR Solid State Relay → Electric heating tube

OUT2(아르 자형) → Intermediate Relay → Cooling water solenoid valve (cooling circuit)

ALM1: Absolute high overtemperature alarm; ALM2: Sensor breakage alarm

RS485 connected to Siemens S7-1200 / Mitsubishi FX5U PLC

Critical Controller Parameter Settings

  1. 제어 모드: HEAT/COOL 2-PID
  2. Action type: Heating Reverse Action, Cooling Direct Action
  3. Enable AT auto-tuning to auto-calculate heating & cooling gain
  4. 의사소통: 모드버스 RTU, 9600, 8, N, 1

Project Benefits

Contactless SSR supports frequent cycling and extends heater service life; relay dedicated to cooling water valve; centralized collection of temperature data for multiple TCUs via PLC, production curve monitoring on HMI/SCADA.

사례 2: Constant-Temperature Circulating Hot Air Oven / Food Baking Oven

Working Requirements

Temperature range 30~220°C; electric heating for temperature rise, exhaust fan activates for overheat ventilation; local panel operation + remote setpoint via HMI; audible & visual alarm when temperature exceeds limit.

Hardware Layout

감지기: Type K Thermocouple

OUT1(큐) → SSR → Heating elements

OUT2(아르 자형) → Relay → Heat exhaust fan

Dual alarms: High absolute limit alarm, deviation alarm

RS485 directly connected to Weinview / Kunlun Tongtai HMI (PLC not mandatory)

Operation Tips

Ovens feature large thermal inertia; appropriately increase derivative time parameter. Set cooling dead band to prevent frequent toggle between heater and exhaust fan.

사례 3: Auxiliary Zone Temperature Control for Plastic Extruder Barrel

Working Requirements

Thermal holding of extruder barrel section; cooling water jacket enabled when temperature rises excessively; unified communication management via machine main PLC.

Hardware Layout

Type K thermocouple mounted on outer barrel surface

OUT1: SSR control for heating bands

OUT2: Cooling water solenoid valve

RS485 integrated into machine Modbus bus; PLC reads zone process temperatures

Selection Advantage vs RR model

E5EC-QR2ASM-820 outperforms RR type: Contactless SSR on heating channel supports 24/7 continuous production and avoids relay contact ablation.

사례 4: Small High-Low Temperature Test Chamber / Thermostatic Water Bath

Working Requirements

Precise temperature control ±0.5°C; heating compensation at low temperature, refrigeration activated at high temperature; support simple programmable temperature ramp/soak profile.

공들여 나열한 것

Immersion Pt100 RTD probe

OUT1 = Heating SSR; OUT2 = Refrigeration compressor / chilled water circulation pump

Built-in 2-PID heating-cooling balance suppresses minor temperature fluctuations.

메모: Frequent compressor start-stop should be avoided; add start-stop delay logic in PLC program.

사례 5: Lithium Battery Formation & Aging Thermostatic Cabinet (에너지신산업)

Working Requirements

Constant aging temperature 45°C; heater turns on when temperature drops, cooling fan activates for overheat; multiple controllers networked, MES system collects temperature data for traceability.

Architecture

Daisy-chain RS485 wiring for multiple E5EC units

PLC acts as Modbus master to poll PV(process value), SV(set value) and alarm status of each controller.

Two alarm outputs wired into safety circuit; overtemperature triggers overall equipment shutdown protection.

사례 6: Small Rubber Curing Mold Heating Device

Working Requirements

Constant curing temperature 150~170°C; forced water cooling triggered on overtemperature; temperature adjustable locally, recipe parameters downloadable remotely.

Typical Fault Prevention

Cooling channel uses relay output, not suitable for ultra-frequent switching. PID buffering mitigates temperature fluctuation to prevent rapid cycling of cooling water valve.

Universal Wiring Logic (Applicable to all above cases)

  1. 전원공급장치: 단말기 1, 2 → AC100~240 V
  2. OUT1 (3,4): SSR drive → Heating load
  3. OUT2 (5,6): Relay output → Cooling valve / 냉각팬
  4. 11(에이), 12(비): RS485 communication wires
  5. Sensor terminals: Wiring for Pt100 RTD / 열전대

적합한 & Unsuitable Application Summary

✅ Recommended to select E5EC-QR2ASM-820

  1. Systems requiring Heating + Cooling bidirectional control
  2. High-frequency switching heating loads driven by SSR
  3. RS485 Modbus communication required with PLC/HMI
  4. Demand for two independent alarm outputs

❌ Not recommended for this model

  1. Only heating function required, no cooling (choose E5EC-QX2ASM-800 for cost saving)
  2. Continuous 4~20 mA analog output required (select QX series)
  3. Heater burnout detection via CT current transformer required (choose suffix -828 models)

이전:

답장을 남겨주세요

메시지를 남겨주세요