The H3BA-8H is an older model discontinued in 1997. It only supports single ON-delay operation, ~와 함께 1 time-limit SPDT + 1 instantaneous SPDT contact. It is an 8-pin socket-mounted type. Do not confuse it with the newer H3BA-N8H, as they are different models entirely.
✅ 핵심 기능
작동 모드: ON-delay only (Mode H). No flicker, OFF-delay, one-shot or other multi-mode functions.
산출: 1 time-limit SPDT + 1 instantaneous SPDT (1c each). The instantaneous contact operates immediately upon power-up; the time-limit contact switches only after the preset time elapses. Widely used for star-delta motor starting.
재설정 방법: Power reset only (power cycle reset). No external reset terminal.
베이스: 8-pin socket (PF085A / P2CF-08 or equivalent 8-pin timer 기지).
✅ Time Ranges (Selected via DIP Switch)
4 time multipliers + 4 time units (비서 / 10에스 / 분 / 10시간)
Multipliers: 1.2, 3, 12, 30
Total timing coverage: 0.12 ~ 300 시간
✅ Electrical Specifications (Older H3BA-8H)
전원공급장치: AC100~120 V / AC200~240 V / DC24 V (varies by suffix)
접촉 등급: 5 A at AC250 V (저항 부하)
반복 정확도: ±2% FS (풀 스케일)
Panel Size: 48×48 square; surface or flush mounting
전력 소비: Several VA; RC solid-state timing circuit
✅ Model Differentiation (Common Pitfall)
- H3BA-8H (Discontinued Older Model)
Single ON-delay only; 결정된 1 time-limit + 1 instantaneous contact; 8-핀; no multi-mode selector switch.
- H3BA-8 (Discontinued Older Model)
Single ON-delay only; 2 time-limit contacts (2기음), no instantaneous contact.
- H3BA-N8H (Current Production New Model)
Multi-function model; toggle between two output configurations: Mode A (2 time-limit contacts) or Mode H (time-limit + instantaneous contact). 지원합니다 8 작동 모드.
✅ Officially Recommended Replacement
H3CR-A8E (AC/DC24 V, DC48~125 V); H3CR-A8EL (AC100~240 V)
Same 8-pin footprint; matches ON-delay + instantaneous output exactly.
메모: The H3CR body is shorter. If reusing the original PF085A socket, fit Y92H mounting clips. Installing a new P2CF-08 base is the simplest option.
✅ 일반적인 애플리케이션
Star-delta reduced-voltage motor starting; instantaneous bypass circuit energized on power-up, then switched to main circuit after delay. Used for fans, 공기 압축기, and conveyor sequential control.
✅ 문제 해결 가이드
- Instantaneous contact fails to actuate on power-up: Check power terminals and poor socket contact.
- Timing inaccuracy: Verify range & unit DIP switch settings. Worn potentiometers are the top failure cause on aged H3BA-8H units.
- Contact fails to switch after timing elapses: Internal solid-state component failure. No spare parts available for this discontinued model; replace directly with H3CR-A8E.
H3BA-8H (단종 모델) Accuracy Specification
중요사항: The H3BA-8H uses an RC analog solid-state timing circuit. All accuracy figures are calculated against the full scale (FS) of the selected range, not against the set time value. This is the most frequent mistake with analog timers.
Factory datasheet rating: Repeat accuracy ±2% FS (풀 스케일).
Breakdown of Accuracy Specifications
- 반복 정확도 (Cycle-to-cycle fluctuation with identical setting): ±2% FS
예: 30 s full-scale range → maximum fluctuation ±0.6 s.
If you set only 3 에스, the fluctuation remains ±0.6 s, resulting in much higher relative error.
- Dial Setting Error (Mechanical dial deviation): ±5% FS ±0.05 s
Intrinsic error of analog potentiometers; more significant on short time ranges.
- Voltage Influence: ±0.5%FS
- Temperature Influence: ±2% FS
- Fixed offset for the minimum 1.2 s range: ±10 ms
Operating Mode Clarification
No mode selector switch. Flicker, OFF-delay, one-shot and other timing sequences are not supported.
Timing Sequence:
Power ON → Instantaneous contact closes immediately
Timing starts simultaneously. When preset time expires → Time-limit contact switches
Reset only via power cut; no external reset terminal.
Output hardware is fixed at factory: 1 time-limit SPDT + 1 instantaneous SPDT. No contact reconfiguration possible. This is the key difference from the newer H3BA-N8H.
⚠️ Easy Confusion: H3BA-N8H (Current New Model)
The H3BA-N8H lets you switch between two output combinations, but the base operation remains ON-delay only:
Mode A: 2 time-limit contacts (no instantaneous output)
Mode H: 1 time-limit + 1 instantaneous contact (star-delta use)
It still does not support OFF-delay, flicker or one-shot modes — only contact combination selection.
✅ True Multi-Model Unit: H3BA-N (11-핀)
The H3BA-N offers 8 selectable operating modes:
A ON-delay, B Flicker (OFF-start), B2 Flicker (ON-start), C Signal ON-delay, D Signal OFF-delay, E Interval, G Signal ON-delay, J One-shot.
한 문장 요약
The older H3BA-8H supports only ON-delay timing, with fixed 1 time-limit + 1 instantaneous contact. No timing mode switching is available.
Factors Affecting Timing Accuracy of H3BA-8H
The H3BA-8H is an RC analog solid-state timer based on resistor-capacitor charging/discharging. All errors stack on top of the ±2% FS base rating.
- Internal Component Aging (No.1 On-Site Issue for Old H3BA-8H)
Timing electrolytic capacitors: Capacitance decay and increased leakage current are the leading cause of timing drift and unstable speed. Timing error far exceeds factory rating after long-term energization.
Adjustable potentiometer: Oxidation and contact wear cause inconsistent resistance at the same knob position, degrading repeatability.
Drift of timing resistors and comparator ICs with temperature.
This model has been out of production for decades. On second-hand or legacy equipment, aging drift almost always outweighs voltage and temperature errors.
- 주변 온도
Temperature changes alter resistance and capacitance of RC components. Factory-rated temperature drift: ±2% FS.
High temperature near contactors, inverters and heat-generating loads leads to fast/slow timing drift. Low temperature also causes deviation.
작동 온도 범위: -10 ~ +55 ℃. Do not use below freezing point.
- Supply Voltage Fluctuation
Voltage variation changes the capacitor charging slope. Factory voltage error: ±0.5%FS.
Voltage sags and sudden drops caused by large motor startup directly alter timing.
Always operate within the rated voltage range; error spikes sharply beyond the voltage tolerance.
- Time Range Selection (Critical Setup Mistake)
Analog timer error is calculated on full scale (FS), not on the set value.
예: 30 s full range → ±0.6 s maximum error. If you set only 3 에스, relative error becomes very large.
✅ Best Practice: Select the smallest suitable range; set the time close to the upper limit of the range. Avoid short timing on a large full-scale range.
- Manual Setting Error
Intrinsic dial error: ±5% FS ±0.05 s
Parallax reading error, loose knob, mis-set DIP switches (sec/min/h mix-up). Wrong time unit causes multiple-fold timing deviation.
Always double-check the time unit DIP setting.
- Electromagnetic Interference (EMI)
Noise from inverters, 접촉기, solenoid valves and welding equipment disturbs the internal comparator circuit, leading to random timing jumps, premature or delayed switching.
배선 권장 사항: Separate control wiring from power cables; do not run alongside inverter output cables in the same trunking.
- Reset Condition (Power-Only Reset Characteristic)
The H3BA-8H has no external reset terminal; reset is only achieved by cutting power.
Insufficient power-off time leaves residual charge on the timing capacitor. Next power-up starts timing from an incorrect baseline, resulting in shorter-than-set time.
Ensure adequate power-off reset time to guarantee consistent timing cycle after cycle.
- 진동, Humidity and Dust
진동: Poor potentiometer contact and cracked solder joints lead to unstable timing.
높은 습도, dust and oil contamination: Circuit board oxidation and leakage current shift the RC timing parameters.
접촉기,회로 차단기,감지기,인코더,PLC,변환기