CHINT NXC-65 AC Contactor

NXC-65 from the Kunlun Series by CHINT Electric is a 3-pole AC contactor, rated at 65A in the NXC series. The full model is typically expressed as NXC-65 [Coil Voltage] [Frequency] (e.g., NXC-65 220V 50Hz). It is mainly used for frequent starting and control of AC motors, as well as remote making and breaking of ...

  • Product Details

NXC-65 from the Kunlun Series by CHINT Electric is a 3-pole AC contactor, rated at 65A in the NXC series. The full model is typically expressed as NXC-65 [Coil Voltage] [Frequency] (e.g., NXC-65 220V 50Hz). It is mainly used for frequent starting and control of AC motors, as well as remote making and breaking of circuits.

Core Electrical Parameters

ItemSpecificationDescription
Rated Operational Current (Ie)65ARated current of the main circuit
Conventional Thermal Current (Ith)80AMaximum continuous operating current
Rated Operational Voltage (Ue)220V~690VVoltage range of the main circuit
Number of Poles3PThree-phase main contact design
Main Contact Configuration3NO (3 Normally Open)Standard for connecting three-phase power
Auxiliary Contacts1NO + 1NCBuilt-in 1 NO and 1 NC, expandable
Coil VoltageAC24V/127V/220V/380V, etc.Multiple voltages available for various control systems
Mechanical Life1,200,000 operationsMechanical operating cycles
Electrical Life100,000 operationsElectrical cycles under rated load
Applicable StandardsGB/T 14048.1/IEC 60947-1, GB/T 14048.4/IEC 60947-4-1National and international standards

Product Features

  1. Compact structure: Kunlun series design, small size, low installation space requirement
  2. High reliability: Made of high-quality materials with precision manufacturing, suitable for harsh industrial environments
  3. Low power consumption: Low coil power loss, obvious energy-saving effect
  4. Easy installation & maintenance: Standard 35mm DIN rail mounting, clear terminals for easy operation
  5. Strong expandability: Optional auxiliary contacts, air delay modules and other accessories available
  6. Good safety performance: Excellent arc extinguishing performance and high breaking capacity

Applications

AC motor control: Frequent start, stop and reversing control for three-phase asynchronous motors up to approx. 30kW

Industrial automation systems: Control of production lines, conveyors, fans, pumps, etc.

Electrical control systems: Combined with thermal overload relays to form magnetic starters for motor overload protection

Building electrical: Air conditioning systems, fire equipment, water pump control systems

New energy equipment: Auxiliary control circuits for charging piles, PV inverters, etc.

Partial List of CHINT NXC Series Models

ModelRated CurrentConventional Thermal CurrentTypical Motor PowerNotes
NXC-066A10AUp to 2.2kWMinimum rating
NXC-1212A16AUp to 5.5kW
NXC-1818A25AUp to 7.5kW
NXC-2525A32AUp to 11kW
NXC-3232A40AUp to 15kW
NXC-4040A50AUp to 18.5kW
NXC-5050A63AUp to 22kW
NXC-6565A80AUp to 30kW
NXC-8080A100AUp to 37kW
NXC-9595A125AUp to 45kW
NXC-115115A140AUp to 55kW
NXC-150150A175AUp to 75kW

Cross-Brand Comparison (Equivalent AC Contactors)

Below is a comparison between CHINT NXC-65 and equivalent contactors from major brands, all functionally compatible:

CHINTSchneiderSiemensABBDelixiCompatibility
NXC-65LC1D65M7C3RT2036-1AP00A63-30-10CJX2-6511Functionally compatible, slight dimensional differences, mounting may need adjustment

Brand Feature Comparison

BrandCore StrengthsTypical Applications
CHINTCost-effective, extensive after-sales networkGeneral industrial control, civil & building electrical
SchneiderInternational brand, mature technology, high reliabilityHigh-end industrial automation, critical equipment
SiemensHigh intelligence, strong communication functionsIndustry 4.0, intelligent manufacturing
ABBHigh performance, robust in harsh environmentsHeavy industry, new energy, rail transit
DelixiAffordable, high domestic market shareSMEs, civil electrical systems

Important Notes

  1. Ensure the coil voltage matches the control system to avoid malfunction.
  2. Use the contactor with protective devices such as thermal overload relays for motor overload protection.
  3. For high-frequency operation, select models with longer electrical life or increase maintenance frequency.
  4. Ensure firm wiring of main and control circuits to prevent failures caused by poor contact.

CHINT Contactor Full Series Coding System & Cross-Brand Reference

  1. CHINT Contactor Series Overview & Naming Rules

1.1 Main Series Classification

SeriesPositioningCurrent RangeTypical Applications
NXC SeriesKunlun, new flagship6A~630AGeneral industrial control, motor starting, power distribution
NC1 SeriesEconomic basic series9A~95ASmall equipment, lighting control
NC2 SeriesStandard industrial series9A~630AGeneral industrial & motor control
NC8 SeriesHigh-performance series6A~100AFrequent operation, precision control
CJX2 SeriesClassic predecessor of NXC9A~95ATraditional industrial equipment, small motors
CJ20 SeriesHigh-current series10A~630AHigh-power motors, heavy-duty equipment
CJ19 SeriesCapacitor switching dedicated16A~100AReactive power compensation, capacitor cabinets
NCH8 SeriesHousehold / civil use16A~63ASmart home, small appliances
NXJ SeriesMini electromagnetic relay5A~10AControl circuits, signal switching
CKJ SeriesVacuum contactor63A~630AHigh-voltage applications, frequent starting

1.2 CHINT Contactor Model Naming Rules

NXC Series Format

NXC □□□ [M] [Coil Voltage] [Frequency]

│     │    │      │        │

│     │    │      │        └─ Coil frequency (50Hz/60Hz, default 50Hz)

│     │    │      └─ Coil voltage (AC24V/110V/220V/380V or DC24V/110V/220V)

│     │    └─ M = reversing contactor; blank = non-reversing

│     └─ Rated operational current (A)

└─ Brand code + product type (CHINT + AC contactor)

Auxiliary Contact Marking

Base model: default 1NO + 1NC (11)

Extended format: NXC-□□□-[XX], where XX = contact combination (01=0NO1NC, 22=2NO2NC)

Special Function Codes

Z: DC-operated contactor

N: Reversing contactor (NS = horizontal, NC = vertical)

-12: Newer version with improved performance

  1. Complete CHINT Contactor Model List

2.1 Full NXC Series (Kunlun)

ModelRated CurrentThermal CurrentTypical Motor Power (AC-3, 380V)Base Aux. Contacts
NXC-066A10AUp to 2.2kW1NO+1NC
NXC-099A12.5AUp to 3kW1NO+1NC
NXC-1212A16AUp to 5.5kW1NO+1NC
NXC-1818A25AUp to 7.5kW1NO+1NC
NXC-2525A32AUp to 11kW1NO+1NC
NXC-3232A40AUp to 15kW1NO+1NC
NXC-4040A50AUp to 18.5kW1NO+1NC
NXC-5050A63AUp to 22kW1NO+1NC
NXC-6565A80AUp to 30kW1NO+1NC
NXC-8080A100AUp to 37kW1NO+1NC
NXC-9595A125AUp to 45kW1NO+1NC
NXC-115115A140AUp to 55kW1NO+1NC
NXC-150150A175AUp to 75kW1NO+1NC
NXC-185185A210AUp to 90kW1NO+1NC
NXC-225225A250AUp to 110kW1NO+1NC
NXC-265265A300AUp to 132kW1NO+1NC
NXC-300300A350AUp to 160kW1NO+1NC
NXC-370370A400AUp to 200kW1NO+1NC
NXC-400400A450AUp to 220kW1NO+1NC
NXC-500500A560AUp to 250kW1NO+1NC
NXC-630630A700AUp to 315kW1NO+1NC

2.2 Core Models of Other Series

SeriesCore ModelsCurrent RangeKey Features
NC1NC1-09/12/18/25/32/40

/50/65/80/95

9A~95ACompact, economical
NC2NC2-09~1509A~150AStandard design, versatile
NC8NC8-06~1006A~100ALow power, long mechanical life
CJX2CJX2-09~959A~95AMounting compatible with Schneider LC1-D
CJ20CJ20-10~63010A~630AHigh current carrying capacity
CJ19CJ19-16~10016A~100ASpecial arc quenching for capacitor switching
  1. Cross-Brand Reference for CHINT Contactors

3.1 General Contactor Cross Reference (AC-3, 380V)

CHINTSchneiderSiemensABBDelixiFunctional Compatibility
NXC-06LC1D0610M5C3RT2015-1AP00A6-30-10CJX2-0610Fully compatible, minor dimensional differences
NXC-09LC1D0910M5C3RT2016-1AP00A9-30-10CJX2-0910Fully compatible, minor dimensional differences
NXC-12LC1D1210M5C3RT2017-1AP00A12-30-10CJX2-1210Fully compatible, minor dimensional differences
NXC-18LC1D1810M5C3RT2026-1AP00A18-30-10CJX2-1810Fully compatible, minor dimensional differences
NXC-25LC1D2510M5C3RT2027-1AP00A26-30-10CJX2-2510Fully compatible, minor dimensional differences
NXC-32LC1D3210M5C3RT2036-1AP00A30-30-10CJX2-3210Fully compatible, minor dimensional differences
NXC-40LC1D4010M5C3RT2037-1AP00A40-30-10CJX2-4010Fully compatible, minor dimensional differences
NXC-50LC1D5010M5C3RT2040-1AP00A50-30-10CJX2-5010Fully compatible, minor dimensional differences
NXC-65LC1D6510M5C3RT2046-1AP00A63-30-10CJX2-6510Fully compatible, minor dimensional differences
NXC-80LC1D8010M5C3RT2056-1AP00A75-30-10CJX2-8010Fully compatible, minor dimensional differences
NXC-95LC1D9510M5C3RT2066-1AP00A95-30-10CJX2-9510Fully compatible, minor dimensional differences
NXC-115LC1D11510M5C3RT2076-1AP00A110-30-10CJX2-11510Generally compatible, mounting may need adjustment
NXC-150LC1D15010M5C3RT2086-1AP00A145-30-10CJX2-15010Generally compatible, mounting may need adjustment

3.2 Brand Technical Comparison

BrandTechnical FeaturesStrengthsPrice Position
CHINTModular Kunlun design, low-power coil, long-life contactsGeneral industry, building electricsMid-low, cost-effective
SchneiderTeSys series, intelligent control, rich communicationHigh-end automation, critical loadsMid-high, leading tech
Siemens3RT series, high reliability, integrated protectionIndustry 4.0, smart manufacturingHigh, stable
ABBModular, high noise immunity, eco-friendly materialsHeavy industry, new energy, transitHigh, premium performance
DelixiCJX2 compatible with CHINTSMEs, civil installationsLow, affordable
  1. Selection & Replacement Guidelines

4.1 Key Selection Parameters

  1. Rated current (Ie): Select according to load; for motors, Ie ≥ 1.2 × motor rated current.
  2. Coil voltage: Must match control system (AC/DC not interchangeable).
  3. Operating frequency: For >1200 operations/hour, use long-life models.
  4. Auxiliary contacts: Choose based on control logic (default 1NO+1NC).
  5. Mounting: Standard 35mm DIN rail; high-current models may use bolt mounting.

4.2 Cross-Brand Replacement Notes

  1. Mechanical compatibility

NXC mostly compatible with Schneider LC1-D mounting, but hole positions differ slightly.

Models above 100A vary greatly; brackets may need modification.

  1. Electrical compatibility

Coil voltage and frequency must match exactly.

Auxiliary contact ratings differ (CHINT ~5A, some Schneider ~10A).

Short-circuit coordination with fuses/circuit breakers should be rechecked.

  1. Performance differences

NXC: mechanical life 1.2 million, electrical life 100,000 (AC-3).

Premium Schneider/Siemens models reach 200,000 electrical cycles for ultra-frequent use.

4.3 NXC vs CJX2 Replacement

CHINT CJX2Equivalent NXCUpgrade Benefits
CJX2-09NXC-09Smaller, lower power, longer life
CJX2-12NXC-12Smaller, lower power, longer life
CJX2-18NXC-18Smaller, lower power, longer life
CJX2-25NXC-25Smaller, lower power, longer life
CJX2-32NXC-32Smaller, lower power, longer life
CJX2-40NXC-40Smaller, lower power, longer life
CJX2-50NXC-50Smaller, lower power, longer life
CJX2-65NXC-65Smaller, lower power, longer life
CJX2-80NXC-80Smaller, lower power, longer life
CJX2-95NXC-95Smaller, lower power, longer life
  1. Quick Motor Selection Table
Motor Power (kW)Rated Current (A)Recommended CHINTSchneiderSiemensABB
2.25NXC-06LC1D06103RT2015A6-30-10
36.5NXC-09LC1D09103RT2016A9-30-10
5.512NXC-12LC1D12103RT2017A12-30-10
7.516NXC-18LC1D18103RT2026A18-30-10
1123NXC-25LC1D25103RT2027A26-30-10
1532NXC-32LC1D32103RT2036A30-30-10
18.539NXC-40LC1D40103RT2037A40-30-10
2247NXC-50LC1D50103RT2040A50-30-10
3063NXC-65LC1D65103RT2046A63-30-10
3778NXC-80LC1D80103RT2056A75-30-10
4594NXC-95LC1D95103RT2066A95-30-10

CHINT contactors cover a full range from 6A to 630A. The NXC (Kunlun) series offers greatly improved performance, reliability and compatibility, and can directly replace the CJX2 series and equivalent products from other brands. For cross-brand replacement, verify rated current, coil voltage, mounting dimensions and auxiliary contact configuration to ensure stable system operation.