Full Model: EMG 17-REL/KSR-24/21-21-LC
✅ Basic Information
Part No.: 2940391
Product Type: DIN-rail mounted electromagnetic relay module (built-in miniature relay soldered, relay core non-removable)
Series: EMG 17-REL
Origin: Germany
HS Code: 85364190
Connection: Screw terminal M3
Dimensions: 17.5(W) ×75(H) ×62.5(D) mm
Packaging: 10 pcs per box, minimum order 1 pc
⚙️ Core Electrical Parameters
Coil Supply: 24V AC/DC universal, typical current 18mA, power consumption 0.43W
Contact Configuration: 2 changeover contacts DPDT (2C)
Contact Material: AgNi silver nickel, suitable for medium-load applications
Rated Continuous Current: 5A; maximum inrush switching current 6A
Maximum Switching Voltage: 250V AC/DC
Mechanical Life: approx. 5×10⁷ operations
Operating Temperature: -20℃ ~ +40℃; Storage Temperature: -20℃ ~ +70℃
Isolation: Basic isolation between input and output, with status LED and surge suppression circuit
Wiring Cross-section: 0.2–4mm² solid wire / 0.2–2.5mm² flexible wire
📌 Terminal Definition
A1/A2: Coil power supply (24V AC/DC)
11, 12, 14: 1st changeover contact
21, 22, 24: 2nd changeover contact
📋 Application Scenarios
PLC/controller signal isolation, low-side control of high-power loads, solenoid valves, contactors and indicator light circuits.
Feature: Integrated soldered construction, relay core cannot be replaced separately; interchangeable pluggable models belong to the RIF series.
🔁 Alternative Reference (Compatible Equivalents)
Same brand alternative: RIF-1-RSC-24DC/2X21 (pluggable relay core, easier maintenance, same width 17.5mm)
Domestic alternative: 17.5mm width relay module, 24V AC/DC, 2 changeover contacts, screw terminal type
📎 Certifications
cULus, EAC, CE; compliant with EN 61810-1, EN50178
Full List of Phoenix Contact EMG-REL Relay Modules
Note: EMG-REL includes 3 sub-width series: EMG10-REL (10mm), EMG17-REL (17.5mm, mainstream), EMG22-REL (22.5mm). All adopt soldered built-in relays (non-removable relay core), screw terminals and DIN rail mounting.
KSR = standard monostable electromagnetic relay; SG = latching relay; G = DC-only coil; W = AC-only coil; LC = LED indicator + surge suppression circuit
- EMG 17-REL / 17.5mm (Most Common, including 2940391)
| Part No. | Full Model | Coil Voltage | Contact Spec | Remarks |
| 2940391 | EMG 17‑REL/KSR‑24/21‑21‑LC | 24V AC/DC | 2 changeover (2C) | ✅ Item you enquired, AgNi, with LED & suppression circuit |
| 2940430 | EMG 17‑REL/KSR‑W230/21‑21‑LC | 230V AC | 2 changeover (2C) | AC-only version, dual contacts |
| 2953854 | EMG 17‑REL/KSR‑24/21 | 24V AC/DC | 1 changeover (1C) | Single changeover, simplified version without LC |
| 2947420 | EMG 17‑REL/KSR‑12/21 | 12V AC/DC | 1 changeover (1C) | 12V universal model |
| 2947653 | EMG 17‑REL/KSR‑230/21 | 230V AC/DC | 1 changeover (1C) | 230V universal, dual A2 terminal |
| 2946353 | EMG 17‑REL/KSR‑230/21/SO54 | 230V AC/DC | 1 changeover (1C) | SO54 special contact configuration, reinforced insulation |
| 2949994 | EMG 17‑REL/KSR‑G24/SO38 BK | 24V DC | 1 normally open (NO) | Black housing, AgSnO₂, 80A inrush withstand, dedicated for lamp loads |
| 2946654 | EMG 17‑REL/SG‑B48/21/P | 48V DC | 1 changeover (1C) | SG latching relay, with forward diode circuit |
- EMG 10-REL / 10mm Narrow Version (Cabinet Space Saving)
| Part No. | Full Model | Coil Voltage | Contact Spec | Remarks |
| 2942108 | EMG 10‑REL/KSR‑G24/1‑LC | 24V DC | 1 normally open (NO) | With LED, AgNi for standard loads |
| 2941400 | EMG 10‑REL/KSR‑G60/1‑LC AU | 60V DC | 1 normally open (NO) | AU gold-plated contacts, for low-current weak signals |
- EMG 22-REL / 22.5mm Wide Version (High Isolation / Built-in Transistor Drive)
| Part No. | Full Model | Coil Voltage | Contact Spec | Remarks |
| 2951885 | EMG 22‑REL/KSR‑24/21 | 24V AC/DC | 1 changeover (1C) | High isolation, 5kV dielectric strength, general purpose |
| 2952350 | EMG 22‑REL/KSR‑G24/TRN35 | 24V DC | 1 changeover (1C) | Built-in NPN transistor, direct drive by low-current PLC outputs, hybrid relay |
- Suffix Explanation for Model Selection
KSR: Standard monostable electromagnetic relay
SG: Latching relay (remains state after power loss)
G: DC-only coil
W: AC-only coil
LC: Integrated LED status indicator + coil surge suppression circuit (freewheeling diode / varistor)
/21: 1 changeover contact (1C: 11/12/14)
/21-21: 2 changeover contacts (2C: 11-12-14 & 21-22-24)
SO38 / SO54: Special contact material (AgSnO₂, suitable for lamp loads and high inrush current)
AU: Gold-plated contacts, weak signal and low-level circuits
TRN35: Built-in NPN pre-drive transistor
- Key Distinction (Avoid Confusion with RIF Series)
EMG-REL: Relay soldered to base, non-replaceable relay core, cost-effective for fixed installation
RIF-REL / RIF-1: Plug-in replaceable relay core, separate base and relay, easier maintenance, same width for replacement
Application Fields of Phoenix Contact EMG-REL Relay Modules
Positioning: Isolation relay for PLC / controller digital interfaces. Soldered integrated DIN-rail modules. Core functions: low-voltage signal isolation, signal amplification, level conversion, driving contactors, valves and indicator loads. Special variants (AU gold-plated, SO38 high-inrush, SG latching, TRN built-in transistor) for differentiated working conditions.
- General Industrial Automation (Most Common, including 2940391)
Machine tools, packaging equipment, conveyor lines, injection molding machines, woodworking machinery and custom automation control cabinets
Isolation for PLC DO channels: PLC 24V DC outputs driving contactors, solenoid valves, indicator lights and sound-light alarms
Door interlock, status feedback, fault alarm circuits, auxiliary start-stop control
Advantage: LC versions with LED and suppression circuit suppress reverse EMF and protect PLC modules
- Building Automation / HVAC
Air handling units, fresh air systems, fan coil units, air dampers and water valve actuator control
Lighting circuits, exhaust fans, water pumps, BA system signal interfaces
230V AC coil variants directly work with mains circuits; narrow EMG10-REL saves cabinet space
- Water Treatment & Municipal Water Supply / Drainage
Clean water tanks, sewage pump stations, chemical dosing systems, bar screens, valve actuation and liquid level alarm signal isolation
Stable screw wiring suitable for long continuous operation in humid cabinet environments
- Renewable Energy (PV, Energy Storage, Wind Power)
Inverter cabinets, combiner boxes, auxiliary control for box-type transformers, fault alarm and status dry contact upload
Signal isolation to prevent strong electrical interference to acquisition boards; for onshore power stations (No ATEX certification, RIF explosion-proof series for hazardous areas)
- Logistics Sorting & Warehouse Automation
Sorters, roller conveyors, stackers, AGV control cabinets, high-frequency switching signals, brake control and solenoid valves for sorting chutes
High mechanical life (up to 5×10⁷ operations) for frequent switching cycles
- Infrastructure: Tunnel & Road Lighting, Pump Stations
Lighting control (SO38 models with AgSnO₂ contacts withstand high inrush current from incandescent and LED lamps, up to 80A inrush)
Remote start-stop control of fans and drainage pumps
- Test Equipment, Instrumentation & Medical Equipment
AU gold-plated variants: Low contact resistance for mA-level weak signal switching, sensor signal switching and test fixtures; not suitable for high-power loads, gold layer may be damaged by arcing
- Other Applications
Control cabinet signal transfer, relay logic expansion, remote IO isolation, auxiliary dry contacts for fire alarm linkage
SG latching variants: retain switching state after power loss for state memory applications
✅ Selection Guide by Suffix
KSR standard type: General solenoid valves, contactors, indicator lights (90% common applications, e.g. 2940391)
SO38 BK: Lamp loads, capacitive loads, high inrush current
AU gold-plated: Weak signal, instrument and low-current test circuits
SG latching: State retention after power failure
TRN35 built-in transistor: Direct drive by low-current PLC outputs without external pre-resistor
⚠️ Not Suitable Applications
EMG-REL complies with Class A EMC standards, not designed for consumer electronics. It does not have forcibly guided contacts, cannot be used for PLd / PLe safety circuits (safety relays with forcibly guided contacts required). No ATEX certification, not permitted in explosive hazardous areas.
Working Principle of Phoenix Contact EMG-REL Relay Modules
EMG-REL is an integrated electromagnetic relay module. Base, electromagnetic relay, LED indicator and suppression components are assembled in one DIN-rail housing. The relay core is permanently soldered and non-pluggable. Fundamentally, it is an electromechanical contact relay for low-voltage control of high-voltage circuits, electrical isolation and signal conversion.
- Basic Electromagnetic Principle
- Coil Side (Control Terminals A1/A2)
When rated coil voltage (DC24V / AC24V / AC230V etc.) is applied to A1 and A2, excitation current flows through the coil and generates magnetic flux on the iron core. The magnetic force overcomes spring tension and pulls the armature.
Coil energized → Armature pulls in → Contacts switch
Coil de-energized → Magnetic field disappears → Spring resets → Contacts return to original position
AC/DC universal coil versions (such as 2940391) have coil windings designed for both AC and DC supply. Pure DC (suffix G) and pure AC (suffix W) variants use different winding parameters.
- Contact Side (Load Terminals 11/12/14, 21/22/24)
Changeover contacts (1C / 2C) include normally closed (NC) and normally open (NO):
De-energized state: Common terminal (11) connects to NC (12) and disconnects from NO (14)
Coil energized: Common terminal (11) disconnects from NC (12) and connects to NO (14) to activate the external load (solenoid valves, contactor coils, indicator lights etc.)
- Principle of Built-in Auxiliary Components (LC suffix, 2940391 is LC version)
LC = LED indicator + coil surge suppression circuit
LED status indicator: Wired parallel to the coil. Lights up when coil is powered to visually indicate drive signal presence. Integrated current-limiting resistor matched to rated voltage.
Surge suppression circuit (freewheeling diode / varistor):
Relay coils are inductive loads and produce high reverse EMF upon de-energization, which may damage PLC output chips.
DC coils: Usually use freewheeling diodes to dissipate inductive energy
AC coils: Use varistor or RC snubber circuits to suppress AC voltage spikes
Models without LC suffix have no indicator or suppression; external surge protection must be added.
- Differentiated Principle of Special Sub-models
- SG Latching Version (EMG…SG)
Not conventional monostable relays. Permanent magnet inside:
Forward pulse power → Contacts close and stay latched after power removal
Reverse pulse power → Contacts reset and stay open after power removal
No continuous power required to maintain state, only pulse signal for switching, low power consumption.
- TRN35 Built-in Transistor Version (EMG…TRN35)
NPN pre-drive transistor integrated before coil: Low-current PLC signal drives the transistor first, then the transistor energizes the relay coil. Suitable for PLC channels with weak drive capacity.
- AU Gold-plated Contact Version
Gold plating on contact surface reduces contact resistance for mA-level weak signal switching. Not for heavy loads; gold plating is vulnerable to arc damage under high current.
- SO38 (AgSnO₂ Contacts)
Tin oxide silver contact material, arc-resistant and withstands high inrush surges, dedicated for lamp and capacitive loads to prevent contact welding.
- Electrical Isolation Logic
Basic insulation separates the coil control circuit and load contact circuit. It isolates PLC low-voltage side from high-voltage load side, blocks common-mode interference and prevents load-side faults from propagating into controller IO boards.
⚠️ Important: This is only functional isolation. It is not a safety relay with forcibly guided contacts and cannot be used for PLe / PLd safety circuits.
- Simplified Working Flow (2940391, EMG17-REL/KSR-24/21-21-LC)
PLC digital output → 24V AC/DC supplied to A1/A2 → LED on, coil energized → Magnetic field pulls armature → Two changeover contacts switch synchronously → Solenoid valve / contactor energized
PLC output off → Coil de-energized → Suppression circuit dissipates residual coil energy → Spring resets contacts → Load de-energized
Contactor,circuit breaker,sensor,Encoder,PLC,Converter



















NH42-63-318x560.png)