Siemens 3RV1901-1A Side-Mounted Auxiliary Contact

Nome completo do produto: SIRIUS Classic side-mounted auxiliary contact (lateral auxiliary switch) Suitable for legacy 3RV1 motor protection circuit breakers, frame sizes S00 / S0 / S2 / S3; terminal de parafuso, 1NÃO+1NC (1 normalmente aberto + 1 normalmente fechado) Vida útil: Obsoleto (Eliminação gradual). It is an accessory for the older 3RV1 platform; the manufacturer promotes the upgraded ...

  • Detalhes do produto

Nome completo do produto: SIRIUS Classic side-mounted auxiliar contato (lateral auxiliary switch)

Suitable for legacy 3RV1 motor protection circuit breakers, frame sizes S00 / S0 / S2 / S3; terminal de parafuso, 1NÃO+1NC (1 normalmente aberto + 1 normalmente fechado)

Vida útil: Obsoleto (Eliminação gradual). It is an accessory for the older 3RV1 platform; the manufacturer promotes the upgraded 3RV2 platform.

Especificações principais

Configuração de contato: 1NÃO + 1NC

Montagem: Lateral side mounting (distinguished from front-mounted 3RV1901-1E)

Fiação: Terminais de fixação por parafuso

Avaliação de contato: AC-12, máx.. 6UM / 240V e; commonly used for 24VAC/DC, 220VAC signal feedback in control circuits

Proteção: IP20

Aplicativo: Passive feedback of circuit breaker ON/OFF status for PLC, indicator lamps and circuit interlocks

Compatible breaker bodies: 3RV10, 3RV11, 3RV13, 3RV14, 3RV16 and other legacy 3RV1 motor protectors; not directly compatible with the new 3RV2 series

Explicação do código do modelo

3RV1: Legacy SIRIUS motor protection circuit breaker series

3RV19: Accessory group for the 3RV1 series

01: Interruptor auxiliar

1UM: Lateral mounting, 1NÃO+1NC, terminais de parafuso

Opções de substituição (Importante)

  1. If migrating to 3RV2 circuit breakers: Front auxiliary contact 3RV2901-1E (1NÃO+1NC, parafuso); lateral type 3RV2901-2E (2NÃO+2NC)
  2. If keeping the existing 3RV1 breaker body: Apenas estoque / second-hand 3RV1901-1A is available; 3RV29xx accessories cannot be fitted onto legacy 3RV1 breakers
  3. Other accessories of the same series for reference:

3RV1901-1E: Contato auxiliar montado na frente, 1NÃO+1NC

3RV1901-1J: Lateral, 2NÃO

3RV1901-1C: Lateral, 2NC

Full Accessory List for Siemens 3RV1 (Legacy SIRIUS Motor Protection CB)

Compatible bodies: 3RV10 / 3RV11 / 3RV13 / 3RV14 / 3RV16; frame S00, S0, S2, S3; entire series obsolete. Accessories fit only 3RV1 bodies and cannot be installed on 3RV2

Terminal distinction: -1xxx = screw terminals; -2xxx = spring-cage terminals

  1. Contatos Auxiliares (Feedback de status, reflects CB ON/OFF position)
Número do pedido.Posição de montagemConfiguração de contatoObservações
3RV1901-1ALateral1NÃO+1NCModel inquired, terminal de parafuso
3RV1901-1BLateral2NÃO+2NCParafuso
3RV1901-1CLateral2NCParafuso
3RV1901-1JLateral2NÃOParafuso
3RV1901-2ALateral1NÃO+1NCSpring-cage
3RV1901-2BLateral2NÃO+2NCSpring-cage
3RV1901-2CLateral2NCSpring-cage
3RV1901-1EFrente (transverse)1NÃO+1NCParafuso, most common front type
3RV1901-1FFrente2NÃOParafuso
3RV1901-1DFrente2NCParafuso
3RV1901-1GFrente1NÃO+1NCFor low-current / electronic circuits, dust-resistant
3RV1901-0HDust cover for front auxiliary contact-Protective cap, pacote de 10

Limitação: Maximum one lateral auxiliary contact per 3RV1 breaker; montado na frente + lateral can be used together.

  1. Fault Signal Switch (Trip signal, distinguishes overload / curto-circuito, not equal to standard auxiliary contact)
Número do pedido.Configuração de contatoObservações
3RV1921-1M1NÃO+1NCFault contact, actuates only on overload or short-circuit trip; no action during manual ON/OFF. For PLC fault alarm.
  1. Liberação de subtensão (UVT, trip on loss of supply)
Número do pedido.Tensão da bobina
3RV1902-1AB0AC24V 50Hz
3RV1902-1AF0AC110V 50Hz
3RV1902-1AP0AC230V 50Hz
3RV1902-1DC0CC24V
  1. Liberação de derivação (MERDA, disparo remoto)
Número do pedido.Tensão da bobina
3RV1903-1AB0CA24V
3RV1903-1AF0AC110V
3RV1903-1AP0AC230V
3RV1903-1DC0CC24V

Release rule: Undervoltage release and shunt release are mutually exclusive, cannot be fitted on the same breaker.

  1. Door-coupled Rotary Operating Mechanism (External cabinet operation, IP65, padlockable)
Número do pedido.Comprimento do eixoCompatible Frame
3RV1926-0B130milímetrosS0 / S2 / S3
3RV1926-0K330milímetrosS0 / S2 / S3

Função: Cabinet door cannot be opened when CB is closed; lockable in OFF position to prevent accidental closing.

  1. Busbar Modules (Main circuit interconnection for side-by-side mounting)

S00 / Quadro S0

Número do pedido.Propósito
3RV1915-1ABBusbar for 2 breakers
3RV1915-1BBBusbar for 3 breakers
3RV1915-1CBBusbar for 4 breakers
3RV1915-1DBBusbar for 5 breakers
3RV1915-3AB2 breakers (with space for accessories)
3RV1915-3BB3 breakers (with space for accessories)
3RV1915-3CB4 breakers (with space for accessories)

S2 Frame

Número do pedido.Propósito
3RV1935-1A2 breakers
3RV1935-1B3 breakers
3RV1935-1C4 breakers
3RV1935-3A2 breakers (with space for accessories)
  1. Contactor Link Module (Direct assembly for 3RV1+3RT1 starter group, no extra busbar)
Número do pedido.Compatible Assembly
3RA1941-1BMecânico & electrical link for 3RV1.41 + 3RT1.4 starter combination
  1. Selos, Capas & Other Mechanical Accessories
Número do pedido.Descrição
3RV1920-1AKit de vedação, prevents unauthorised adjustment of current setting dial
3RV1910-1AExtended terminal cover

Cross Reference for Migration to 3RV2 Platform

Legacy 3RV1 Part No.3RV2 Replacement
3RV1901-1A (Lateral 1NO+1NC, parafuso)3RV2901-1A
3RV1901-1E (Front 1NO+1NC, parafuso)3RV2901-1E
3RV1921-1M (Fault signal switch)3RV2921-1M

Notas de seleção de chave

  1. Contatos auxiliares padrão (3RV1901): Only indicate handle position, cannot distinguish fault trip. Fault alarm requires 3RV1921-1M.
  2. Liberação de subtensão: The breaker must be closed before supply is restored; it trips automatically when supply fails. Liberação de derivação: Trips when energised.
  3. Busbars have two versions: standard and accessory-space type. If auxiliary contacts are fitted on the side, select suffix 3AB/3BB/3CB.
  4. Only stock items are available for purchase; manufacturer no longer accepts new production orders.

Operating Principle of 3RV1901-1A (Mechanically Synchronised Position Auxiliary Switch)

Core summary: Pure mechanical linkage, contact state follows the mechanical position of the 3RV1 handle synchronously. It only reflects ON / OFF status and cannot detect overload or short-circuit faults.

It is a passive snap-on auxiliary contact module clipped to the side of the 3RV1 motor protection circuit breaker. No electromagnetic components or trip detection mechanism inside.

  1. Mechanical Linkage Structure

The operating mechanism of the breaker handle and main contacts has a drive cam. Once 3RV1901-1A is fully engaged, its internal lever bears against this cam:

Handle movement → cam displacement → actuates internal rocker mechanism of auxiliary contact

Internal double-break silver bridge contact, one changeover contact (CO:1NÃO+1NC) with snap-action spring to ensure clean switching without chatter.

Estados operacionais

  1. Circuit Breaker ON

Handle switched to ON position, cam fully advanced: NÃO fechado, NC aberto

→ ON signal to PLC, run indicator lamp energised

  1. Circuit Breaker OFF (Manual opening)

Handle switched to OFF position, cam retracts: NÃO aberto, NC fechado

→ Stop status feedback

  1. Circuit Breaker Tripped by Overload / Curto-Circuito

⚠️ Importante: Depois de tropeçar, the handle rests in the intermediate trip position. The handle mechanism also drives the cam, so 3RV1901-1A switches to OFF state (NÃO aberto, NC fechado).

✅ Limitation: This contact alone cannot tell whether opening is manual or fault-induced.

👉 Separate fault alarm requires 3RV1921-1M (fault signal switch). It has an independent trip plunger and only switches state on overload/short-circuit trip; no action on manual ON/OFF.

  1. Características Elétricas

Passive dry contact, no internal power supply; it is simply a mechanical switch to route low-current signals for PLC digital inputs, lamps and interlock circuits.

Utilisation category AC-12: 6UM / 240V e. Designed exclusively for control signal circuits, not permitted for main power circuits.

Contact timing: Switches nearly synchronously with the main breaker contacts, no advance or delayed action (slightly different from contactor auxiliary contacts).

  1. Comparison with 3RV1921-1M (Common Pitfall in Selection)
Número da peça.Actuation SourceDistinguish manual OFF vs fault tripAplicativo
3RV1901-1ACam from handle mechanism❌ No, same contact state for both casesPosition feedback, run indication, general interlock
3RV1921-1MIndependent plunger from thermal / magnetic trip unit✅ Yes, state changes only on fault tripAlarme de falha, registro de falhas, fault interlock shutdown
  1. Installation Constraints & Notas Adicionais

Lateral mounting. Maximum one lateral auxiliary contact (3RV1901-1A) per 3RV1 breaker; one front auxiliary contact (3RV1901-1E) may be added together.

Poor snap fit causes the internal lever to lose engagement with the cam: handle moves but auxiliary contact does not toggle (most frequent site fault).

Insulated housing separates high-voltage main circuit from signal contacts, meeting low-voltage isolation requirements.

Common Site Misconception

❌ Mal-entendido: 3RV1901-1A is a fault contact and triggers alarm when tripped

✅ Correction: It is only a position contact. An open signal from this contact to PLC merely means the breaker is not closed. Combine it with 3RV1921-1M using AND/OR logic to discriminate fault trip.