Danfoss FC-051P18KT4E20H3BXCXXXSXXX Inverter - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Danfoss FC-051P18KT4E20H3BXCXXXSXXX Inverter - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

inversor solar/

Danfoss FC-051P18KT4E20H3BXCXXXSXXX Inverter

Con estructura compacta, high-efficiency control and reliable performance, Danfoss FC-051P18KT4E20H3BXCXXXSXXX inverter delivers outstanding performance in fields including fans & bombas de agua, manejo de materiales, food & textile industry, tratamiento de agua, achieving an average energy-saving rate of 30-50%. It also extends service life of equipment, improves product quality and cuts maintenance costs. Reasonable configuration shall be conducted ...

  • Detalles del producto

Con estructura compacta, high-efficiency control and reliable performance, Danfoss FC-051P18KT4E20H3BXCXXXSXXX inverter delivers outstanding performance in fields including fans & bombas de agua, manejo de materiales, food & textile industry, tratamiento de agua, achieving an average energy-saving rate of 30-50%. It also extends service life of equipment, improves product quality and cuts maintenance costs. Reasonable configuration shall be conducted according to load characteristics, ambient conditions and control requirements during model selection to maximize its technical advantages.

  1. Definición del código del modelo
CódigoSignificadoDescripción detallada
FC-051Código de serieVLT® Micro Drive FC-51 Compact General-purpose Inverter Series
P18KClasificación de potenciaMatched motor power: 18.5kilovatios / 25caballos de fuerza
T4Power Supply Spec.T=Three-phase input; 4=380-480VAC voltage class
E20Clase de protecciónProtección IP20, chassis mounting type
H3RFI FilterEquipped with RFI Class A1/B (C1) filtrar
BUnidad de frenoBuilt-in brake chopper
incógnitaLocal Control PanelWithout local control panel (LCP to be ordered separately)
doPCB CoatingCoated printed circuit board for higher reliability in harsh environments
incógnitaPower OptionStandard power configuration without special options
incógnitaAdapter AStandard cable entry
incógnitaAdapter BNo extra adapters
SXXXVersión de softwareLatest standard software version
M5Tamaño del marcoM5 frame (corresponding to 18.5kW power grade)
Número de pedido.132F0060Official unique identification code
  1. Especificaciones técnicas básicas
CategoríaEspecificaciónObservaciones
Parámetros básicos
Potencia nominal18.5kilovatios / 25caballos de fuerzaMatched motor power
Corriente de salida nominal37A (Trabajo pesado) / 34A (Light-duty)Current values for different load types
Voltaje de entrada3-phase 380-480VACAllowable fluctuation: ±10%
Frecuencia de entrada50/60HzAuto-adaptive
Voltaje de salida0~100% of input voltageVaries with frequency
Frecuencia de salida0-200Hz (VVC+ Mode) / 0-400Hz (U/f Mode)Control de vectores / V/f ratio control
Control Features
Modo de controlVVC+ (Voltage Vector Control), U/f ControlClosed-loop vector control available (encoder optional)
Capacidad de sobrecarga150% corriente nominal para 60 artículos de segunda claseStandard overload protection
Acc/Dec Time0.1~3600sAcceleration and deceleration time set independently
Entrada digital5 programmable inputsSupport PNP/NPN logic, 0-24VCC
Entrada analógica1 channel 0-10V/4-20mAProgrammable functions
Salida de relé2 canales (1 NO + 1 CAROLINA DEL NORTE)Max switching capacity: 250VAC/2A
Physical Properties
Grado de protecciónIP20Chassis mounting
Método de enfriamientoNatural cooling + refrigeración por aire forzadoM5 frame with built-in fan
Temperatura ambiente-20°C ~ +50°CDerating operation required above 40°C
Humedad relativa5%~95%, sin condensaciónStandard industrial environment requirement
PesoAprox.. 9.98kilos (net weight)Aprox.. 10.27kg with package
Proceso de dar un título & Cumplimiento
Certificaciones de seguridadCE, UL, cUL, RoHSCompliant with EU Low Voltage Directive 2014/35/EU
EMC StandardEN 55011 Clase AEMC requirement for industrial environment
ECCN CodeEU: Y901, US: 3A999.aExport control classification code
  1. Full Series Model List (380-480V Trifásico)
FuerzaModeloOrder NumberCorriente nominalTamaño del marco
0.37kilovatiosFC-051PK37T4E20H3BXCXXXSXXX132F00011.1AM1
0.75kilovatiosFC-051PK75T4E20H3BXCXXXSXXX132F00022.1AM1
1.5kilovatiosFC-051P1K5T4E20H3BXCXXXSXXX132F00033.7AM1
2.2kilovatiosFC-051P2K2T4E20H3BXCXXXSXXX132F00045.2AM1
3.0kilovatiosFC-051P3K0T4E20H3BXCXXXSXXX132F00247.0AM2
4.0kilovatiosFC-051P4K0T4E20H3BXCXXXSXXX132F00259.3AM2
5.5kilovatiosFC-051P5K5T4E20H3BXCXXXSXXX132F002612.5AM3
7.5kilovatiosFC-051P7K5T4E20H3BXCXXXSXXX132F002717.0AM3
11kilovatiosFC-051P11KT4E20H3BXCXXXSXXX132F005925.0AM4
15kilovatiosFC-051P15KT4E20H3BXCXXXSXXX132F006032.0AM5
18.5kilovatiosFC-051P18KT4E20H3BXCXXXSXXX132F006037.0AM5
22kilovatiosFC-051P22KT4E20H3BXCXXXSXXX132F006145.0AM5
  1. Cross-brand Equivalent Model Comparison
Danfoss FC-051P18KT4E20H3BXCXXXSXXXsiemensSchneiderTEJIDOReplacement Suggestion
18.5kW/37A/380-480VSINAMICS G120C 6SL3210-1KE22-6UF1Altívar 320 ATV320U40N4ACS150-03E-04A1-4Funciones similares, communication protocols need matching
Modo de control: VVC+/U/fControl de vectoresControl de vectoresControl de par directo DTCABB features fastest dynamic response; Schneider offers higher cost performance
Built-in brake chopperExternal accessory requiredIncorporadoExternal accessory requiredDanfoss features more flexible configuration
RFI Class A1/BOptional Class A/BBuilt-in Class AOptional Class A/BMeet industrial EMC standards
Without LCP (comprado por separado)Standard BOP-2Standard keypadStandard assistant control panelSiemens owns friendliest operation interface

Obsolete Replacement: FC-051 is still mainstream without direct discontinued substitutes. For function upgrade, choose Danfoss FC-301 series with richer functions and support for PROFINET and other advanced communication protocols.

  1. Entorno de aplicación & Industry Cases

Escenarios aplicables

aficionados & Bombas de agua: sistemas de climatización, water treatment plants, cooling towers, realize 30%-50% energy saving via variable frequency speed regulation

Material Conveying: Transportadores, polipastos, maquinaria de embalaje, achieve smooth start/stop and precise speed control

Alimento & Beverage Industry: Filling lines, máquinas etiquetadoras, sterilization equipment, adapt to humid environment with PCB coating protection

Maquinaria Textil: Máquinas de hilar, weaving machines, satisfy low-speed high-torque demands

Small Machine Tools: Drilling machines, fresadoras, grinders, realize accurate speed adjustment

Non-recommended Scenarios

Heavy-duty impact loads: Such as crushers and punch presses (FC-302 series is recommended)

Ocasiones a prueba de explosiones: Special explosion-proof models required (FC-051 has no explosion-proof certification)

Altitude above 1000m: Derating operation needed (1% power reduction per 100m rise)

Ambient temperature over 50°C: Additional cooling measures or derating operation required

Casos de aplicación típicos

  1. Constant Pressure Water Supply System

Adopt FC-051P18KT4 to control 18.5kW water pump with closed-loop control via pressure sensor, realizing 40% ahorro de energía, stabilizing pipeline pressure and extending equipment service life.

  1. Packaging Production Line

Four sets of FC-051 series inverters including 18.5kW model are applied to control conveyor speed for synchronous operation, lowering product damage rate and greatly reducing downtime frequency.

  1. Central Air-conditioner Fan System

Applied in shopping mall air conditioner fans to adjust rotating speed automatically by ambient temperature, ahorrando sobre 28,000 RMB electricity fee annually per unit and reducing operating noise.

  1. Air Freight Compliance & Proceso de dar un título

Air Freight Regulations

Built-in Capacitor: Equipped with DC bus electrolytic capacitors without lithium batteries, UN38.3 test report is not required

Transport Classification: Non-dangerous goods, deliverable as common electronic products by air

Packaging Requirements

Power off completely with capacitors discharged for more than 5 minutos

Fixed in anti-static package to avoid collision damage

Mark with labels ofFragile Electronic Equipment” y “This Side Up

Main Certifications

Código de fallaFault DescriptionPosibles causasPasos para solucionar problemas
AL16Output Short Circuit1. Cortocircuito en el devanado del motor1. Cut off power and disconnect UVW motor wiring
2. Damaged motor cable2. Test three-phase motor winding resistance balance
3. Power module failure3. Check cable insulation condition
4. Reset and test inverter output under no-load state
AL10Motor Overheating1. Overloaded operation1. Confirm actual load within rated range
2. Poor motor heat dissipation2. Clean motor heat sink
3. Temperature sensor failure3. Inspect PT100 and thermistor connection
AL51DC Bus Undervoltage1. Low input voltage1. Measure input voltage (rango normal: 342-528V)
2. Phase loss of power supply2. Check three-phase power balance
3. Rectifier bridge failure3. Detect rectifier module output
AL71Inverter Overheating1. Temperatura ambiente excesivamente alta1. Ensure ambient temperature ≤40°C
2. Cooling fan malfunction2. Check fan running status
3. Radiator blockage3. Remove dust and sundries on radiator
AL52Pérdida de fase de entrada1. Power supply phase missing1. Measure three-phase input voltage
2. Terminales de cableado flojos2. Fasten terminal wiring
3. Faulty input contactor3. Test contactor switching performance
  1. Fallos comunes & Troubleshooting Guide
Nombre del accesorioModeloFunciónNecessity
Local Control PanelLCP 12On-site parameter setting and monitoringRecomendado (not standard equipped)
Resistencia de frenoMCE 101-0300Dissipate regenerative energy and prevent overvoltageMandatory for models with code B
Communication ModuleFC CAN/ProfibusRealize industrial network connectionOptional on demand
Input FilterH3 Upgrade KitUpgrade EMC performance to Class BRecommended for electromagnetic sensitive occasions
Cubierta protectoraFC-051-IP40Upgrade protection class to IP40Recommended for dusty working sites
  1. Selection Rules & Quick Tips
  2. Coincidencia de poder: Inverter rated current ≥ 1.1 times motor rated current to cope with starting impact
  3. Voltage Confirmation: Input voltage shall stay within 380-480V with fluctuation ≤±10%
  4. Brake Configuration: Models with code B have built-in brake choppers, external brake resistors required (power ≥ 30% of motor power)
  5. Disipación de calor: Keep ventilation space over 10cm for M5 frame; derate 10% power per 5°C rise above 40°C
  6. Communication Expansion: Additional Modbus/Profibus modules need separate purchase for network communication
  7. Recommended Key Accessories
Nombre del accesorioModeloFunciónNecessity
Local Control PanelLCP 12On-site parameter setting and monitoringRecomendado (not standard equipped)
Resistencia de frenoMCE 101-0300Dissipate regenerative energy and prevent overvoltageMandatory for models with code B
Communication ModuleFC CAN/ProfibusRealize industrial network connectionOptional on demand
Input FilterH3 Upgrade KitUpgrade EMC performance to Class BRecommended for electromagnetic sensitive occasions
Cubierta protectoraFC-051-IP40Upgrade protection class to IP40Recommended for dusty working sites

Full Analysis on Application Cases of Danfoss FC-051P18KT4E20H3BXCXXXSXXX (18.5kilovatios) Inversor

  1. Overview of Core Application Fields

This 18.5kW/37A/380-480V inverter with built-in brake chopper and coated PCB board is widely applied relying on VVC+ vector control, IP20 protection and high cost performance:

HVAC industry: Central air conditioner fans, cooling towers, bombas de agua

Tratamiento de agua: Constant pressure water supply, aeration tanks, sludge return pumps

Manipulación de materiales: Heavy-duty conveyors, ascensores, logistics sorting lines

Food industry: Filling machines, sterilization equipment, máquinas de embalaje

Textile industry: Máquinas de hilar, weaving machines, setting machines

Building material machinery: Mezcladores, light-duty crushers

  1. Detailed Introduction of Five Typical Application Cases

Caso 1: Constant Pressure Water Supply for Residential Communities

Original power frequency water supply system suffered from severe pressure fluctuation, high power consumption and frequent pump startup-stop. After adopting FC-051 constant pressure frequency conversion control system with pressure sensor feedback, it realizes sleep & wake-up automatic operation, cutting daily power consumption greatly, stabilizing water supply pressure and prolonging pump service life obviously.

Caso 2: Central Air-conditioner Fan System in Shopping Malls

Replace fixed-speed fan operation with variable frequency temperature closed-loop control, set minimum frequency to avoid fan surging, realize intelligent speed regulation according to indoor temperature, save massive electricity cost annually and lower operating noise effectively.

Caso 3: Food Packaging Production Line Multi-machine Linkage

Adopt multi-speed regulation and synchronous follow-up control to match operating speed of different conveying equipment. Built-in brake chopper achieves rapid stop, reduces material stacking and product damage rate, and improves overall production efficiency. Coated PCB adapts to humid and dusty food workshop environment.

Caso 4: Spinning Machine Control System in Textile Mill

Replace traditional slip speed regulating motor with VVC+ vector control inverter, realize high torque output at low speed, broaden speed regulation range, promote motor operating efficiency, reduce yarn breakage rate and cut daily maintenance frequency.

Caso 5: Aeration System for Sewage Treatment Plant

Match dissolved oxygen sensor to build PID closed-loop control system, automatically adjust fan air volume to keep dissolved oxygen content in optimal range, stabilize sewage treatment effect, reduce invalid energy consumption and lower equipment abrasion.

  1. Application Scene Matching Table
Application SceneMatching LevelVentajas principalesNotas
Constant pressure water supply / circulating pump★★★★★PI regulation + intelligent logic, prominent energy-saving effectEquipped with pressure sensor and brake resistor suggested
Central air conditioner / cooling tower fan★★★★★Temperature closed-loop control, low noise and energy savingSurge prevention setting required, derate at high altitude
Heavy conveyor / hoist★★★★☆Stable start-stop, strong overload resistanceConfirm actual load type in advance
Alimento & beverage production line★★★★☆Multi-speed control, high synchronization precisionCoated PCB for humid environment adaptation
Textile printing & dyeing machinery★★★★☆Low-speed high torque, wide speed rangeAdd anti-interference measures
Sewage treatment aeration system★★★★☆Precise PID control, energy consumption optimizationRegular radiator cleaning required
Heavy impact load equipment★☆☆☆☆Choose FC-302 series instead
Explosion-proof working environment★☆☆☆☆Special explosion-proof inverters required
Altitude over 2000m★☆☆☆☆Not recommended due to large power derating amplitude
  1. Key Selection Points for Practical Application
  2. Match inverter current reasonably according to actual motor load
  3. Select models with built-in brake units for frequent start-stop and fast stop working conditions
  4. Choose U/f control mode for fan & pump loads, VVC+ vector control for transmission and processing equipment
  5. Prioritize coated PCB models for humid, dusty and corrosive sites
  6. Select matched external accessories and control panels according to on-site debugging and remote control demands

Anterior:

Deja una respuesta

Dejar un mensaje