Lenze E82EV552K4C Inverter - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Lenze E82EV552K4C Inverter - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

inversor solar/

Lenze E82EV552K4C Inverter

E82EV552K4C is a 5.5kW three-phase inverter of Lenze 8200 Vector series. It accepts 380-480VAC input, delivers 13A output with IP20 protection grade. Built-in vector control and brake transistor, suitable for general industrial speed regulation applications. Model Code Definition Code Segment Description E82 Platform identifier for Lenze 8200 series inverters EV Vector control, supports precise torque ...

  • Detalles del producto

E82EV552K4C is a 5.5kW three-phase inverter of Lenze 8200 Vector series. It accepts 380-480VAC input, delivers 13A output with IP20 protection grade. Built-in vector control and brake transistor, suitable for general industrial speed regulation applications.

  1. Definición del código del modelo
Segmento de códigoDescripción
E82Platform identifier for Lenze 8200 series inverters
EVControl de vectores, supports precise torque and speed regulation
55Power rating code: 5.5kilovatios (7.5caballos de fuerza)
2Frame size code: Tamaño 2 alojamiento (100×240×140mm)
kIntegrated EMC filter, compatible con EN 61800-3
4Input voltage class: 3-phase 400-500VAC (compatible with 380-480VAC)
doStandard control interface with RS232/485 communication port

Número de orden: E82EV552K4C (Modelo estándar); E82EV552K4C200 (Extended Version)

  1. Especificaciones técnicas principales
CategoríaPresupuestoObservaciones
Parámetros básicos
Potencia nominal5.5kilovatios (7.5caballos de fuerza)Matches standard asynchronous motors
Voltaje de entrada3-phase 380-480VAC, 50/60HzDiseño de amplio voltaje
Voltaje de salida3-phase 0-480VAC, same frequency as inputVector controlled output
Corriente de salida13Una calificación, 150% overload for 60sStrong overload capability
Rango de frecuencia0-599HzApplicable to high-speed motors
Controlar el rendimiento
Modo de controlControl de vectores (Closed-loop V/F)High low-speed torque, ±0.5% precision
Speed Ratio0.111111111Stable wide-range speed adjustment
Torque ResponseLess than 100msFast dynamic response
Braking ModeBuilt-in brake transistor (≤11kW)Compatible with 75Ω/500W brake resistor
Physical Properties
Clase de protecciónIP20Indoor cabinet mounting only
Temperatura ambiente-10℃ ~ +55 ℃ (reducción de potencia por encima de 40 ℃)Almacenamiento: -25℃ ~ +70℃
Humedad relativa5%-95% sin condensaciónKeep away from humid environment
Dimensiones (Ancho×Alto×Profundidad)100×240×140mmStandard size 2 alojamiento
PesoAprox.. 3.5kilosLightweight structure
Comunicación & Funciones
Interfaz estándarRS232/485 (Modbus RTU)Remote parameter configuration supported
Optional ModulesPROFIBUS, DispositivoNet, etc..Compatible with industrial networks
Funciones integradasregulador PID, 4 parameter sets, energy saving modeMulti-scenario adaption
  1. Full E82EV Series Model List

3-phase 400V Series (Suffix K4C)

ModeloFuerzaCorriente de salidaSize CodeObservaciones
E82EV222K4C2.2kilovatios5.5A2Modelo básico
E82EV302K4C3.0kilovatios7.5A2
E82EV402K4C4.0kilovatios10A2
E82EV552K4C5.5kilovatios13A2Current model
E82EV752K4C7.5kilovatios18A2
E82EV113K4C11kilovatios25A3Enlarged housing
E82EV153K4C15kilovatios32A3

3-phase 230V Series (Suffix K2C)

ModeloFuerzaCorriente de salidaSize Code
E82EV251K2C0.25kilovatios1.5A1
E82EV371K2C0.37kilovatios2.0A1
E82EV551K2C0.55kilovatios2.8A1
E82EV751K2C0.75kilovatios3.8A1
E82EV112K2C1.1kilovatios5.5A2
E82EV152K2C1.5kilovatios7.5A2
E82EV222K2C2.2kilovatios11A2

Extended Models (Sufijo 200)

All standard models support 200 sufijo, p.ej. E82EV552K4C200

Enhanced C1-class EMC filter

Extended working temperature: -10℃ ~ +60℃

24-month warranty period

  1. Cross-brand Replacement Comparison
Lenze ModelsiemensSchneiderTEJIDOOmrónReplacement Tips
E82EV552K4CMM440-5.5kWATV312HU55N4ACS550-01-012A-43G3RX-A4055Functions matched, note communication protocol difference
Principales diferenciasRich parameter optionsRentableSuperior overload resistanceCompact dimensionReset parameters when keeping original motor
  1. Fallos comunes & Soluciones
Código de fallaTipo de fallaPosibles causasSoluciones
F02SobretensiónExcessive input voltage, rapid deceleration1. Comprobar tensión de red
2. Ampliar el tiempo de desaceleración
3. Install brake resistor
F05SubtensiónLow input voltage, power fluctuation1. Stabilize power supply
2. Inspect wiring
3. Equip voltage stabilizer
F08OverheatMala disipación del calor, temperatura ambiente alta1. Clean cooling fan
2. Mejorar la ventilación
3. Operate under derated load
F13sobrecorrienteMotor short circuit, carga excesiva1. Check motor winding
2. Reduce load
3. Adjust current limit parameters
Sin visualizaciónFallo de energíaPhase loss, internal power damage1. Verify 3-phase input
2. Test DC bus voltage
3. Replace power module
  1. Air Shipment Compliance & Certificaciones

Air Transport Assessment

Lithium Battery: Built-in electrolytic capacitor, no lithium battery, UN38.3 test exempted

Classification: Ordinary electrical equipment, non-dangerous goods

Embalaje: Anti-static package, fixed firmly against collision

Documents: Commercial invoice, packing list, CE certificate

Certification List

CertificateEstándarÁmbito de aplicación
CEEN 61800-5-1(Seguridad), EN 61800-3(CEM)EU market access
ULUL 508CAmérica del norte
CSAC22.2 No.14Canadá
CCCGB/T 12668.3Porcelana
RoHS2011/65/UEEnvironmental protection compliance

Shipment Instructions

  1. Disconnect all external connections before delivery
  2. Fix inside rigid container with cushion materials
  3. Avoid inversion and violent vibration
  4. Attach copies of certification documents
  5. Application Cases & Adaptación de la industria

Aplicaciones típicas

Material Conveying: Speed control for belt and chain conveyors, encima 30% ahorro de energía

Admirador & Bomba de agua: Constant pressure/flow PID control for central air conditioning and cooling towers

Máquinas herramienta: Spindle drive, stepless speed regulation and fast start-stop

Maquinaria de embalaje: Food and printing equipment, precise synchronous operation

Agitator Equipment: Chemical reactor stirring for variable viscosity materials

Adaptación de la industria

IndustriaIdoneidadVentajasNotas
Automobile Manufacturing★★★★★Alta confiabilidad, quick responseReinforce EMC protection against interference
Alimento & Bebida★★★★☆Suitable protection grade, fácil mantenimientoKeep away from damp and corrosive atmosphere
Logística & almacenamiento★★★★★Excellent energy saving, fácil mantenimientoAdapt to frequent start-stop operation
Industria química★★★☆☆Good temperature resistance, strong overload capacityOptional explosion-proof accessory required
Maquinaria de construcción★★★☆☆Vibration resistance, harsh environment adaptabilityAdditional reinforcement installation

Practical Case

An auto parts factory adopts E82EV552K4C for stamping line conveyor:

Speed control accuracy improved to ±0.1m/min

Energy consumption reduced by 28%, annual power saving about 120,000 RMB

Equipment failure rate decreased by 40%, costos de mantenimiento reducidos 35%

  1. Directrices de selección

Quick Rules

  1. Código de energía: 55=5.5kW, 75=7.5kW, 11=11kW
  2. Voltage Identification: K4=400V, K2=230V
  3. Size Identification: 2=100mm width, 3=140mm width
  4. Función principal: EV=Vector control, K=EMC filter, C=Standard control
  5. Application Environment Requirements

Suitable Conditions

Installed inside industrial automation control cabinets

Temperatura ambiente: -10℃ ~ +40℃, dry, dust-free and non-corrosive air

Stable power grid with voltage fluctuation ≤±10%

Scenarios requiring precise speed and torque adjustment

Unsuitable Conditions

Outdoor or humid locations (insufficient IP20 protection)

Heavy dust and corrosive gas environment

Severe grid fluctuation over ±15% without stabilizer

Heavy load frequent forward/reverse operation without brake resistor

Installation Precautions for Lenze E82EV552K4C

  1. Cabinet Installation Space
  2. Vertical wall mounting only; horizontal, side or upside-down installation forbidden
  3. Reserve ≥100mm vertical clearance, ≥30mm lateral clearance for heat dissipation
  4. Minimum 50mm spacing between multiple inverters to avoid heat interference
  5. Mantener alejado de fuentes de calor, air outlets and direct sunlight
  6. Environmental Limits

Temperatura de funcionamiento: -10℃ ~ +55 ℃, derate load above 40℃

Sin condensación, polvo, corrosive or flammable gas

Keep distance from high-power electromagnetic devices, contactors and motors

Derate operation when altitude exceeds 1000m

  1. Especificaciones de cableado

Cableado del circuito principal

  1. Do not reverse incoming L1/L2/L3 and outgoing U/V/W terminals
  2. Separate power cables and control cables with ≥20cm gap, no same conduit laying
  3. Reliable earthing, resistencia de puesta a tierra ≤4Ω, ground wire diameter no less than half of phase wire
  4. Fasten terminals with proper torque to prevent loose connection and overheating

Cableado del circuito de control

  1. Use shielded twisted pair for analog and communication cables, single-end shielding grounding
  2. Avoid routing signal cables close to power lines
  3. Prevent polarity reversal of external 24V power supply
  4. Disipación de calor & Ventilation
  5. Keep cabinet door ventilated, clean filter screen regularly
  6. Equip cooling fan for smooth air circulation
  7. Avoid direct sunlight on the device
  8. CEM & Anti-interference Protection
  9. Built-in EMC filter works only with complete grounding
  10. Motor cable length recommended ≤50m; install output reactor for long cables
  11. Do not coil or twist input and output wires
  12. Freewheel diodes parallel connected to peripheral relays and solenoid valves
  13. Brake Accessory Installation

Built-in brake transistor matched with external brake resistor

  1. Use 75Ω/500W resistor, mount in well-ventilated area
  2. Short resistor wiring, firm connection and thermal isolation protection
  3. Inspección previa al encendido
  4. Confirm 3-phase 380-480V input without phase loss
  5. Check no inter-phase or earth short circuit, correct and tight wiring
  6. Pass motor insulation test; perform no-load trial run first
  7. Mechanical Fixation
  8. Tighten four mounting screws evenly to avoid shake
  9. Flat mounting surface to prevent housing deformation
  10. Safety Regulations
  11. Wait 5 minutes after power off for DC bus discharge before disassembly
  12. Do not open cover or touch terminals during operation
  13. Forbid short-circuit protection terminals or disable fault protection functions

Anterior:

Deja una respuesta

Dejar un mensaje