ABB ACS550-01-031A-4 Variable Frequency Drive (VFD)

ABB ACS550-01-031A-4 Variable Frequency Drive (VFD) This is an ABB ACS550 series three-phase VFD, rated 15kW (Normal Duty) / 11kW (Robuste), with nominal output current 31A. It is designed for 380-480V power grid, mural (IP21) enclosure, built-in vector control and EMC filter. Suitable for general industrial applications such as pumps, fans and conveyors. Modèle ...

  • Détails du produit

ABB ACS550-01-031A-4 Variable Frequency Drive (VFD)

This is an ABB ACS550 series three-phase VFD, rated 15kW (Normal Duty) / 11kW (Robuste), with nominal output current 31A. It is designed for 380-480V power grid, mural (IP21) enclosure, built-in vector control and EMC filter. Suitable for general industrial applications such as pumps, fans and conveyors.

  1. Définition de la répartition du modèle
SegmentCodeDescription
ID de sérieACS550ABB standard low-voltage AC drive series for general-purpose applications
Type de structure1Wall-mounted construction (IP21 protection rating), for standard industrial environments
Courant nominal031UNNominal continuous output current 31A; corresponds to 15kW for normal duty / 11kW for heavy duty
Classe de tension4Suitable for three-phase 380-480V AC input power (+10/-15% voltage fluctuation tolerance)

Identifiant du produit: 3AUA0000002418-D

Taille du cadre: R3

  1. Core Specification Parameter Table
CatégorieParamètreNotationRemarques
Basic RatingsCourant de sortie nominal (I₂N)31UNContinuous operation at 40℃ ambient
Normal Duty Power15kWStandard 400V operating condition
Heavy Duty Power11kWStandard 400V operating condition
Overload Capability1.1×I₂N (1 minute per 10 minutes)For normal duty; 1.5×I₂hd for heavy duty
Caractéristiques électriquesTension d'entrée3-phase 380-480VInput frequency: 48-63Hz
Tension de sortie3-phase 0 ~ Input VoltageFréquence de sortie: 0-500Hz
Mode de contrôleContrôle vectoriel (Open-loop / Closed-loop)Open-loop accuracy: 20% motor slip; Closed-loop accuracy: 0.1% of rated speed
Fréquence de commutation4kHz (Défaut)Facultatif: 1/2/4/8/12kHz
Interface E/SEntrée analogique2 chaînes (0-10V / 4-20mA)Impédance d'entrée: Tension >312kΩ, Current 100Ω
Sortie analogique2 chaînes (4-20mA)Max load <500Oh, Accuracy ±3%
Entrée numérique6 chaînes24À DC, PNP/NPN compatible
Sortie relais3 chaînesMax 250V AC / 30À DC, Switching current 6A
Interface de communicationBuilt-in RS485 (Modbus)Support expansion of multiple fieldbuses
Caractéristiques physiquesClasse de protectionIP21Configuration standard; IP54 optional
Dimensions (L×H×P)270×600×450mmR3 frame size
PoidsEnviron. 20.5kilosBasic configuration included
Heat Dissipation457WAir flow: 134m³/heure
Environmental LimitsTempérature de fonctionnement-15℃ ~ 50℃Derating required above 40-50℃
Altitude0-1000m (Full rating)Déclasser 1% per 100m elevation increase
Humidité5-95% (Non-condensing)Conforme à la CEI 721-3-3
  1. Accessoires standards & Optional Parts List

3.1 Standard Supplied Accessories

Assistant Control Panel (ACS-CP-D), with real-time clock and parameter modification record function

Built-in Class C2 EMC Filter (First Environment), meets basic EMC requirements

Mounting template for quick drilling position marking

Product manual and quick start guide

Standard I/O terminals and Modbus communication interface

3.2 Recommended Optional Parts

TaperModèleDescription de la fonctionScénario d'application
Control PanelACS-CP-CAdvanced control panel with parameter copy and multi-language supportMise en service & batch configuration for multiple VFDs
Unité de freinageACS-BRK-DBrake chopper + resistor (10.5, 7kW)Frequent start-stop / fast deceleration applications
ReactorLOCH0030-60Output reactor (41UN)Suppress dv/dt when motor cable length >200m
Module de communicationVarious FieldbusProfibus-DP / AppareilNet / EtherNet/IPConnection to PLC control system
Encoder ModuleFacultatifSpeed feedback to improve closed-loop control accuracyHigh-precision speed control applications
Extended I/OFacultatifAdditional 3 sorties relaisMulti-status monitoring & control requirements
  1. Cross-Brand Alternative Comparison Table
MarqueSérieModèle équivalentKey Parameter MatchingDescription de la différence
SchneiderAltivar 610ATV610U15N415kW/31A/380-480VBuilt-in PLC with higher integration
SiemensSINAMICS G120C6SL3210-1PE21-8UL015kW/31A/380-480VModular design with strong expandability
MitsubishiFR-A840FR-A840-15K-NA15kW/31A/380-480VHigh vector control accuracy, suitable for complex loads
DanfossVLT 28002840PT37T20H15kW/31A/380-480VRentable, ideal for fan & pump applications
ABB AlternativeACS510ACS510-01-031A-415kW/31A/380-480VSimplified version for fan/pump, without vector control
  1. Lignes directrices de sélection & Solutions alternatives

5.1 Core Selection Principles

Current Priority: VFD rated current ≥ 1.1~1.3 times motor rated current, do not select only by power rating

Correspondance de charge:

Normal duty (Pump/Fan): Standard selection 15kW/31A

Robuste (Compressor/Crusher): Recommend upgrade to 18.5kW (ACS550-01-038A-4) or higher frame

Adaptation environnementale:

Température >40℃: Derate 5~10% per 5℃ rise

Altitude >1000m: Déclasser 1% per 100m rise

Dust environment: Select IP54 protection grade model

5.2 Solutions alternatives recommandées

Scénario d'applicationSolution recommandéeAdvantage Description
Standard General PurposeACS550-01-031A-4Built-in vector control, performance à coût élevé
Ventilateur & Pump DedicatedACS510-01-031A-4Energy-saving optimized algorithm, moindre coût
High Precision ControlACS550-01-031A-4 + Encoder ModuleContrôle en boucle fermée, speed accuracy up to 0.1%
Heavy Duty Frequent Start-StopACS550-01-038A-4 + ACS-BRK-DHigher power margin + braking assembly, longer service life
Cost-Sensitive ProjectSchneider ATV320U15N4Taille compacte, competitive price

5.3 Installation & Points clés de l'entretien

Cooling clearance reserved: 200mm top and bottom, no special requirement for left and right sides

Protection d'entrée: Recommended 35A gG fuse (UL Class T 40A)

Motor cable: Standard length ≤200m; install output reactor for longer distance

Cycle d'entretien: Inspect cooling fan and capacitor condition after 10,000 operating hours

  1. ACS550 Series Full Power Model List (R3 Frame Size)
ModèleCourant nominalNormal Duty PowerHeavy Duty PowerScénario d'application
ACS550-01-031A-431UN15kW11kWStandard general load
ACS550-01-038A-438UN18.5kW15kWRobuste / Frequent start-stop
ACS550-01-045A-445UN22kW18.5kWHigh-power general load

The ACS550-01-031A-4 is a cost-effective general-purpose vector VFD, suitable for 15kW normal duty / 11kW heavy duty loads. With rich built-in functions and interfaces, it is widely used in general machinery requiring high control accuracy and reliability in industrial automation. Prioritize motor current matching during selection, and determine expansion modules or power upgrade according to load type and ambient conditions.

Complete Full Range Model List of ABB Variable Frequency Drives (Structured Version)

  1. Quick Overview of Model Naming Rules

ABB VFD adopts standard format: ACSxxx-xx-xxxX-xx, definition of each segment as below:

SegmentSignificationExempleDescription
ACSxxxCode de sérieACS550/510/880Product positioning & application category
-xxCode de structure01/04/3101=Wall-mounted IP21; 04=Cabinet-type IP21; 31=Wall-mounted IP54
-xxxXCourant nominal031A/125ANumeric + letter for output current; A = Standard type
-xxClasse de tension2004/2/74=380-480V 3-phase; 2=200-240V 3-phase; 7=500-690V 3-phase
  1. Main Series Overview (Sorted by Power Range)
SériePositionnementPlage de puissanceApplication typiqueCaractéristiques
ACS150Economy Micro Drive0.37-4kWSmall pumps, les fans, rolling shuttersSingle/3-phase universal, opération simple, IP20/IP21
ACS355Compact General Drive0.37-15kWMachines d'emballage, petits convoyeursBuilt-in brake chopper, large plage de tension
ACS510Ventilateur & Pump Dedicated0.75-160kWAlimentation en eau à pression constante, cooling fan, CVCEnergy-saving optimized algorithm, built-in PID, faible coût
ACS550Enhanced General Drive0.75-355kWCompresseurs, convoyeurs, mélangeursContrôle vectoriel, strong heavy-duty capability, CEM intégrée
ACS580New Generation General Machinery Drive0.75-500kWAll kinds of industrial loadsIntegrated safety functions, conception modulaire, intelligent connection
ACS880Flagship High-Performance Drive0.75-2500kWHigh-precision control, complex machineryCompatibilité totale, haute fiabilité, built-in safety functions
ACH550HVAC Dedicated0.75-355kWClimatisation & ventilation systemsBuilding control protocol, comfort control algorithm
  1. Detailed Model List by Series

3.1 ACS550 Series (Enhanced General Drive, IP21 Wall-mounted, 380-480V 3-phase)

ModèleCourant nominalNormal Duty PowerHeavy Duty PowerTaille du cadreCode de commande
ACS550-01-003A-43UN0.75kW0.55kWR13AUA0000002415-D
ACS550-01-004A-44UN1.1kW0.75kWR13AUA0000002416-D
ACS550-01-006A-46UN1.5kW1.1kWR1
ACS550-01-009A-49UN4kW3kWR1
ACS550-01-012A-412UN5.5kW4kWR1
ACS550-01-015A-415UN7.5kW5.5kWR2
ACS550-01-019A-419UN11kW7.5kWR2
ACS550-01-023A-423UN11kW10kWR23AUA0000002417-D
ACS550-01-031A-431UN15kW11kWR33AUA0000002418-D
ACS550-01-038A-438UN18.5kW15kWR3
ACS550-01-045A-445UN22kW18.5kWR3
ACS550-01-057A-457UN30kW22kWR4
ACS550-01-072A-472UN37kW30kWR4
ACS550-01-09A4-494UN45kW37kWR5
ACS550-01-125A-4125UN55kW45kWR53ABD68589657
ACS550-01-157A-4157UN75kW55kWR6
ACS550-01-180A-4180UN90kW75kWR6
ACS550-01-210A-4210UN110kW90kWR7
ACS550-01-250A-4250UN132kW110kWR7
ACS550-01-290A-4290UN160kW132kWR8
ACS550-01-340A-4340UN185kW160kWR8
ACS550-01-400A-4400UN200kW185kWR9

3.2 ACS510 Series (Ventilateur & Pump Dedicated, IP21 Wall-mounted, 380-480V 3-phase)

ModèleCourant nominalPouvoirTaille du cadre
ACS510-01-003A3-43.3UN1.1kWR1
ACS510-01-004A1-44.1UN1.5kWR1
ACS510-01-005A6-45.6UN2.2kWR1
ACS510-01-007A2-47.2UN3kWR1
ACS510-01-009A4-49.4UN4kWR1
ACS510-01-012A5-412.5UN5.5kWR1
ACS510-01-015A6-415.6UN7.5kWR2
ACS510-01-019A0-419.0UN11kWR2
ACS510-01-024A1-424.1UN15kWR3
ACS510-01-030A8-430.8UN18.5kWR3
ACS510-01-038A0-438.0UN22kWR3
ACS510-01-045A0-445.0UN30kWR4
ACS510-01-057A0-457.0UN37kWR4
ACS510-01-072A0-472.0UN45kWR5
ACS510-01-09A4-494.0UN55kWR5

3.3 ACS880 Series (Flagship High-End Drive, Partial Models)

ModèleType de structureCourant nominalPouvoirClasse de tensionCaractéristiques
ACS880-01-003A-4Wall-mounted IP213UN0.75kW380-480VCompact type
ACS880-01-031A-4Wall-mounted IP2131UN15kW380-480VContrôle vectoriel
ACS880-31-145A-3Wall-mounted IP54145UN75kW380-480VÉtanche à la poussière & étanche
ACS880-04-271A-7Cabinet-type IP21271UN160kW500-690VHigh power density
ACS880-07-0450A-7Cabinet-type IP21450UN315kW500-690VConception modulaire

3.4 Selected Models of Other Common Series

SérieModèlePouvoirTensionApplication
ACS355ACS355-03E-04A7-41.5kW380-480VPetites machines
ACS355-03E-12A5-45.5kW380-480VPackaging equipment
ACS150ACS150-03E-03A3-41.1kW380-480VSmall pumps
ACS150-01E-02A4-20.75kW200-240VSingle-phase power supply
ACH550ACH550-01-031A-415kW380-480VHVAC system
ACH550-01-125A-455kW380-480VLarge air conditioning
ACS580ACS580-01-04A5-42.2kW380-480VGeneral machinery
ACS580-01-320A-4160kW380-480VHeavy-duty load
  1. Notes de sélection des clés
  2. Current Priority Principle: VFD rated current ≥ 1.1~1.3 times motor rated current; do not select merely by power rating.
  3. Correspondance du type de charge:

Ventilateur / Pompe: Choose ACS510 / ACS380 for better energy saving

Constant torque / Robuste: Choose ACS550 / ACS880 for stronger overload capability

HVAC dedicated: Choose ACH550 with built-in building control protocol

  1. Adaptation environnementale:

Dust environment: Select IP54 protection grade (par exemple. ACS880-31 series)

High temperature environment: Derating required above 40℃, derate 5~10% per 5℃ rise

Altitude >1000m: Déclasser 1% per 100m elevation increase

  1. Model Extension Rules

Basic model can be extended with +option code for additional functions, examples:

ACS550-01-031A-4+J400: Add Profibus DP communication module

ACS550-01-031A-4+K454: Add brake chopper

ACS550-01-031A-4+L501: Add output reactor