E82: 8200 Série vectorielle
751: 0.75kW (75 = 0.75; the last digit 1 denotes power class)
K4: 3-phase 380~480V voltage class
C: Basic unit, without integrated EMC filter (suffix C200 indicates version with filter)
| Article | Spécification |
| Puissance nominale du moteur | 0.75kW (4-pole asynchronous motor) |
| Alimentation d'entrée | 3-phase AC 320~550V, 45~65Hz |
| Courant de sortie nominal | 1.9UN (at 8kHz carrier frequency) |
| 60s overload current | 3.6UN (180% surcharge) |
| Classe de protection | IP20 |
| Dimensions hors tout (H×L×P) | 240 × 60 × 140 mm |
| Poids | 1.6kilos |
| Carrier frequency | 2/4/8/16kHz selectable |
| Plage de fréquence de sortie | 0~650Hz |
| Modes de contrôle | Contrôle V/F, contrôle vectoriel sans capteur |
| Onboard features | Brake transistor (external brake resistor ERBM370 available) |
| E/S (standard I/O module) | 5DEPUIS, 1IA, 1FAIRE, 1AU, 1 sortie relais |
Caractéristiques fonctionnelles
- Built-in PID, flying restart, motor load loss monitoring, DC braking, 4 parameter set switching;
- Plug-in expansion modules: PROFIBUS, PEUT, INTERBUS and other fieldbus modules;
- Fonctions de protection: court-circuit, défaut à la terre, surtension/sous-tension, surchauffe, motor PTC temperature measurement, motor stall protection;
- Refroidissement: natural air cooling, montage vertical; ambient temperature -10~+55℃, déclassement requis au-dessus de 40 ℃; déclasser 5% for every 1000m elevation above 1000m.
Applications typiques
Ventilateurs, pompes à eau, lignes de convoyeurs, small mixers, general industrial speed regulation, CVC, machines d'emballage.
Des pièces de rechange & Informations de remplacement
- Operator panel: Lenz XT panel;
- Résistance de freinage: ERBM370;
- In-series alternative: E82EV751K4C200 (version with integrated EMC filter);
- Discontinuation note: Le 8200 Vector series is an obsolete model; i500 series is recommended for new unit replacement.
Dépannage courant
Surintensité OC: Court-circuit moteur, câble endommagé, excessive carrier frequency, short circuit in brake circuit;
OV Overvoltage: Too short deceleration time, inertial load, grid surge;
OH Overtemperature: Dust accumulation in cooling channel, température ambiante élevée, insufficient top/bottom installation clearance (≥100mm clearance reserved on top and bottom);
CINH Controller Inhibit: Disconnected enable circuit at terminal 28.
Notes d'installation
Max.. length of shielded motor cable: 50m (8kHz); câble non blindé: 100m. Output du/dt filter is recommended for long motor wiring.
Lenze E82EV751K4C (8200 Vector 0.75kW, 380V) Scénarios d'application
Positionnement de base: Low-power general-purpose vector inverter, suitable for light constant-torque load and simple PID speed regulation. Mostly original equipment on legacy machinery, fin de vie, mainly used for spare part replacement of old equipment.
- Material Conveying Industry (Le plus courant)
Petits convoyeurs à bande, lignes de convoyeurs à rouleaux, chain feeders
Caractéristiques: Vecteur sans capteur, good low-speed torque; S-curve acceleration/deceleration for smooth start-stop to avoid material impact; multi-speed selection supported. Built-in brake transistor, external brake resistor can be fitted for inertial loads requiring fast deceleration.
Utilisation typique: Infeed/outfeed belts of packaging lines, sorting branch lines, petits palans.
- Machines d'emballage
Machines verticales de formage/remplissage/scellage, étiqueteuses, small slitter machines, auxiliary drives for pillow packaging machines, conveyor drives
Avantages: Native PID, simple tension control with dancer roller; 4 parameter set switching for one-click recipe changeover for different products; expandable PROFIBUS/CAN bus for PLC integration.
Industry stock: Large quantity of European legacy packaging machines originally equipped with this drive.
- Industrie de l'imprimerie (Classic OEM Model)
Auxiliary drives for Roland 700 offset presses, paper transport, delivery tray, soufflage d'air / paper traction motors. A popular spare part model in printing machine maintenance market.
Exigences: Stable low-speed operation, flying restart (start with rotating load); inertial load from paper rolls, fast stop achieved with brake resistor.
- CVC & Fluide (Ventilateur & Pompe)
Petits ventilateurs centrifuges, duct exhaust fans, pompes de surpression, pompes doseuses
Built-in PID for constant pressure / couler / contrôle de la température; quadratic V/F mode for energy saving; flying restart for fans still rotating after power loss.
Note: Limited 0.75kW power rating, only for small fans and pumps.
- Machines textiles
Small spinning auxiliary machines, fabric traction rollers, guide rollers, carding auxiliary rollers, simple unwinder/rewinder
Avantages: Constant torque at low speed, low noise at 16kHz carrier frequency to reduce fabric flutter; multi-speed switching for different fabric types.
- Travail du bois, Nourriture & Pharmaceutical Standalone Small Machines
Sanding auxiliary rollers for woodworking, small mixers, mixing tanks, food conveyors, pharmaceutical bottle feeding mechanisms
Operating conditions: Continuous low-speed operation, démarrages et arrêts fréquents, stable torque requirement; cabinet dust protection required for dusty environments.
- Other Niche Applications
Automatic revolving door drive, test bench motor drive, small stirring equipment, laboratory speed regulation platform.
✅ Operating Boundary for Selection
- Moteur: 3-phase asynchronous motor 0.75kW; 380~480V 3-phase power supply
- Type de charge: Light constant-torque load preferred; 180% short-time overload for max. 60s
- Not suitable: Heavy impact loads, high-speed servo positioning, high-precision synchronous control requiring encoder closed loop (8200 Vector is sensorless vector)
- Installation: Indice IP20, must be installed inside control cabinet, cannot be exposed directly on site.
⚠️ Industry Status
This model has been discontinued by the manufacturer for many years. Units available on market are mostly surplus stock or used reclaimed drives. Non recommandé pour les nouveaux projets; Lenze i500 series is preferred for replacement.
I can prepare a E82EV751K4C to i500 replacement selection & parameter migration comparison table if needed.
Method to Verify Suitability of Lenze E82EV751K4C for Your Application
Core premise: This obsolete 8200 Vector 0.75kW sensorless vector inverter is only suitable for spare part replacement on legacy machines; not recommended for new project procurement.
Verification covers four aspects: load power & couple, process control requirements, environnemental & installation conditions, project type (new retrofit / maintenance spare).
- Pouvoir & Correspondance de charge (Primary Check)
✅ Acceptable Conditions
- Rated power of driven motor: 3-phase 0.75kW, 380V asynchronous motor; motor rated current ≤1.9A (inverter rated output current)
- Short-time overload requirement: Max.. 180% overload for up to 60 secondes. Suitable for applications with mild start-stop shock and short peak load.
- Compatible load types:
✅ Recommandé: Light constant-torque loads (conveyor rollers, traction rollers, small mixers), charges à couple variable (petits ventilateurs, petites pompes)
✅ Inertial loads: Paper rolls, bandes transporteuses, fast stop with external brake resistor (onboard brake transistor)
❌ Not Suitable
Puissance du moteur >0.75kW; continuous heavy load, frequent heavy impact loads (concasseurs, stamping mechanisms)
Continuous overload exceeding 180% for extended duration
Quick check formula: Motor rated current ≤ inverter rated output current 1.9A
- Process Control Requirement Check
✅ Processes compatible with this inverter
- Speed regulation: 0~650Hz speed range, sensorless vector without encoder, decent low-speed torque; no high-precision position synchronization required
- Logic functions: Multi-speed selection, built-in PID closed loop (pressure/flow/simple tension), flying restart, DC braking, 4 parameter set switching (multi-product recipe)
- Communication: Expandable PROFIBUS / CAN bus modules for PLC connection; basic DI/DO analog terminal control
- Start-stop: S-curve acceleration/deceleration to reduce mechanical shock, ideal for conveying and packaging auxiliary equipment
❌ Unsuitable Applications
- Applications requiring encoder closed loop, high precision positioning, multi-axis electronic cam, contrôle synchrone (functions of servo or high-end vector drives, 8200 Vector does not support encoder interface)
- High-precision tension unwinding/rewinding, main drive of high-speed precision printing machines
- Operating conditions requiring fast dynamic response and frequent acceleration/deceleration under heavy load
III. Environnemental, Installation & Electrical Conditions
✅ Acceptable
- Alimentation: 3-phase AC320~550V, 45~65Hz
- Installation: Armoire de commande intérieure (IP20); full power at ambient temperature -10℃ ~ +40℃, derating required at 40~55℃; elevation ≤1000m, détarage au dessus de 1000m
- Poussière: Cabinet dust protection required; not for open-air, humidité élevée, corrosive gas environments
- Motor cable: Max.. 50m shielded cable (8kHz); output du/dt filter required for long motor cables
❌ Not Acceptable
Direct outdoor installation, humidité élevée, strong corrosion, heavy metallic dust environment
Excessively long motor cable without output filter
- Project Type Assessment (Critique)
✅ Convient: Remplacement de pièces de rechange, old equipment maintenance
Original machine is factory fitted with E82EV751K4C. Direct same-model replacement, parameters/program can be copied without mechanical or electrical control modification.
Inconvénient: Available stock is surplus or used, unstable lead time, no original manufacturer warranty.
❌ Non recommandé: Nouveaux projets, rénovation complète de la machine
New projects should adopt Lenze i500 series (i510 / i550), meilleures performances, full new warranty, approvisionnement stable en pièces de rechange.
✅ Quick Self-Check Checklist (Tick boxes)
Motor is 3-phase 380V asynchronous motor, rated power 0.75kW, rated current ≤1.9A
Max.. short-time load does not exceed 180% and lasts less than 60 secondes
Only speed regulation and simple PID required, no encoder closed-loop positioning
Inverter mounted inside control cabinet, ambient temperature ≤40℃
Application is legacy equipment maintenance spare replacement, not new machine development
✅ All boxes ticked: E82EV751K4C can be used;
❌ Any box fails: Not recommended, select different power rating or switch to i500 and other new models.
Supplémentaire: Replacement Selection Reference
If requirements are not met, Lenze i500 series (i510 / i550, 0.75kW, 380V) est préféré. Parameter migration supported, more bus options, optional integrated EMC filter, new units readily available.
Lenz 8200 Vecteur (E82EV) Liste complète des modèles
Series full name: E82EV = 8200 Vector vector inverter, IP20 built-in unit, 0.25~90kW, abandonné
Suffix explanation:
K2: Single/3-phase 230V; K4: 3-phases 380~480V
C: Small power housing (0.25~11 kW); B: High power housing (15~90kW)
C200 = Version with integrated EMC filter; base C version without EMC filter (E82EV751K4C in your query is base version without filter)
- 230Classe V (K2, single-phase input, 0.25~7,5 kW)
| Modèle | Pouvoir |
| E82EV251K2C | 0.25kW |
| E82EV371K2C | 0.37kW |
| E82EV551K2C | 0.55kW |
| E82EV751K2C | 0.75kW |
| E82EV152K2C | 1.5kW |
| E82EV222K2C | 2.2kW |
| E82EV302K2C | 3.0kW |
| E82EV402K2C | 4.0kW |
| E82EV552K2C | 5.5kW |
| E82EV752K2C | 7.5kW |
- 400Classe V (K4, 3-phases 380~480V, 0.55~11 kW, C housing)【Focus, E82EV751K4C belongs to this group】
| Modèle | Pouvoir |
| E82EV551K4C | 0.55kW |
| E82EV751K4C | 0.75kW |
| E82EV152K4C | 1.5kW |
| E82EV222K4C | 2.2kW |
| E82EV302K4C | 3.0kW |
| E82EV402K4C | 4.0kW |
| E82EV552K4C | 5.5kW |
| E82EV752K4C | 7.5kW |
| E82EV113K4C | 11kW |
III. 400Classe V (K4, 3-phases 380~480V, 15~90kW, B housing)
| Modèle | Pouvoir |
| E82EV153K4B | 15kW |
| E82EV223K4B | 22kW |
| E82EV303K4B | 30kW |
| E82EV453K4B | 45kW |
| E82EV553K4B | 55kW |
| E82EV753K4B | 75kW |
| E82EV903K4B | 90kW |
✅ Derivative Variants (Même puissance, different suffix)
- C200 version: Add C200 suffix for same power model, integrated EMC filter, example: E82EV751K4C200
- Safe-Standard safe torque off version: suffix 4xx, par exemple. E82EVxxxKxC400 (available for 3~11kW)
- Coated PCB version: PCB conformal coating for humid and dusty environments, suffix xxx1
- E82DV / E82CV: Même 8200 Série vectorielle, different mounting construction:
E82DV: Through-panel mounting
E82CV: Cold plate cooling type (base plate heat dissipation), power range same as E82EV
📌 Optional Accessories List (E82Z series accessories)
E82ZAFSC010: Standard I/O terminal module (E82EV main unit requires this I/O board for operation)
E82ZBC: Basic operator panel; EMZ9371BC: XT advanced panel
E82ZAFPC010: Profibus DP communication module
E82ZAFCC010: Module de communication CANopen
E82ZLxx: Line reactor
ERBM / ERBD: Matching brake resistor
⚠️ Remarks
- L'ensemble 8200 Vector series has been discontinued by OEM. i500(i510/i550) is recommended for new projects;
- Small power E82EV (0.25~11 kW) housing size increases with power rating, all IP20; B housing for 15kW and above with larger dimension;
- C and C200 versions of same power have identical electrical performance, difference only in EMC filter. Interchangeable for spare replacement, EMC compliance needs to be considered.
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

















NH42-63-318x560.png)