Z2: Z2 series economical built-in amplifier capteur photoélectrique
R.: Retro-reflective type (requires matching reflector)
400: Maximum sensing distance of 4 m
N: Sortie NPN, cable type (corresponding connector version: Z2R-400CN4)
Spécifications de base
| Article | Paramètre |
| Méthode de détection | Rétro-réfléchissant (with reflector V-61) |
| Distance de détection | 0.01~4 m (typical range: 0.01~4.4 m) |
| Source de lumière | 4-element red LED, longueur d'onde 640 nm |
| Temps de réponse | ≤500 μs |
| Alimentation | C.C 10 ~ 30 V (y compris 10% ondulation) |
| Sortir | Collecteur ouvert NPN, max load current 100 mA, withstand voltage DC30V, residual voltage ≤1.8 V |
| Consommation d'énergie | ≤13 mA |
| Ajustement de la sensibilité | Single-turn potentiometer adjustable |
| Voyants lumineux | Orange: operation indicator; Vert: stable sensing indicator |
| Protection contre la pénétration | IP67 |
| Operating Ambient Temp. | -25℃ ~ +55℃, humidity 35~85%RH (sans condensation) |
| Matériau du boîtier | Glass fiber reinforced ABS; Front cover PMMA |
| Accessoires | Mounting bracket BEF-W100-B, reflector V-61 |
Caractéristiques du produit
- Red light source with visible light spot for easy alignment during commissioning; capable of detecting semi-transparent objects, ideal for blocking detection on production lines
- Switchable light-on / dark-on operation mode (NON/NF)
- IP67 dustproof and waterproof, vibration and shock resistant, suitable for factory automation and conveyor lines
- Faible consommation d'énergie, standard square housing for universal mounting
- Stable indicator light to judge mounting offset and signal margin
Scénarios d'application typiques
Object presence / position detection on conveyor lines
Obstacle detection for automatic doors and gates
Machines d'emballage, tri logistique, workpiece counting on automated lines
Detection of transparent films and plastic bottles (retro-reflective type offers obvious advantages for transparent materials)
Alternative Model Comparison
Z2R-400P: Mêmes spécifications, PNP cable type
Z2R-400CN4: NPN, M8 connector type
Z2R-400CP4: PNP, M8 connector type
Description du câblage (4-core Cable)
Brun: DC+ 10~30 V
Bleu: 0 V
Noir: Sortie de signal (NPN)
Blanc: Operation mode selection (Lumière allumée / Dark-ON)
OPTEX Z2R-400N Application Case Summary
Recap of key features: Retro-reflective type, sensing range 0.01~4 m, Sortie NPN, IP67, red light source, response ≤500 μs. Reflector V-61 is mandatory. Suitable for stations within 4 m where wiring is only required on the sensor side; compatible with solid workpieces and semi-transparent materials.
Cas 1: Box Presence / Position Detection on Logistics Conveyor (Manutention des matériaux)
Industrie: E-commerce warehousing, packaging conveyor lines
But: Box / tote position confirmation, missing material alarm, product counting on belt conveyors
Installation: Sensor mounted on one side of the conveyor; reflector fixed on the opposite frame. When a box passes and blocks the light beam, an NPN signal is sent to PLC.
Justification de la sélection: 4 m sensing distance accommodates wide conveyors; wiring only needed for sensor, reflector requires no wiring to reduce installation cost; IP67 withstands dust in production environment; visible red light spot for fast on-site alignment.
Logique du processus: Dark-ON. Count is triggered when box passes; continuous light reception without workpiece triggers empty material alarm.
Cas 2: Compte & Position Detection on Tire Production Line (Official OPTEX Reference Case)
Industrie: Rubber tire manufacturing
But: Counting and position signal for tires after vulcanization, preventing stacking
Installation: Sensor and reflector installed opposite across the belt; tire body blocks light beam. Retro-reflective principle is less affected by workpiece color variation for large rubber parts.
Avantages: 500 μs response time suitable for high-speed conveying; adjustable sensitivity via single-turn potentiometer to reduce false triggering in dusty production environments.
Cas 3: Packaging Machinery – Transparent PET Bottle & Film Detection
Industrie: Nourriture, daily chemical filling lines
But: Presence detection of transparent PET bottles and plastic films (diffuse sensors often fail to detect transparent parts)
Remarques: Z2R-400N is standard retro-reflective sensor, supports semi-transparent material detection. Fully transparent glass requires dedicated transparent-object photoelectric sensor such as ZR-Q series. When bottle blocks light beam, return light from reflector is cut off and sensor outputs signal.
Précautions: Thin transparent films require fine potentiometer adjustment to lower sensitivity and avoid missing detection caused by light penetration. Reflector needs regular cleaning to prevent contamination by liquid splashes.
Cas 4: Obstacle Detection for Automatic Doors / Gates
Industrie: Entrepôt automatisé, workshop rolling shutters, AGV channel barriers
But: Obstacle detection as an alternative to safety light curtains, anti-pinch protection
Installation: Sensor mounted on one side of channel, reflector on opposite column. Human / material intrusion blocks light beam to stop door movement.
Avantages: 4 m range meets most channel width requirements; standard square housing compatible with mounting bracket BEF-W100-B; wide temperature range -25~+55℃ adapts to hot and cold workshop environments.
Cas 5: Work Tray & Fixture Return Line Position Confirmation
Industrie: 3C, automotive component assembly lines
But: Position signal for circulating work trays, pre-confirmation signal for robot pick-and-place operation
Installation: Sensor mounted on side of frame, reflector fixed on opposite bracket. Tray in position blocks light beam and sends “tray ready” signal to PLC to enable robot operation.
Avantages: Lumière allumée / Dark-ON switchable via white wire connection to match different equipment logic; NPN output compatible with Japanese PLC input modules.
Cas 6: Discharge Counting for Carton Sealing & Strapping Machines
Industrie: Post-packaging equipment
But: Count finished packaged products and missing package alarm
État de fonctionnement: Heavy vibration, paper scraps and dust on equipment; IP67 protection against vibration and impact; large light spot maintains stable detection with minor workpiece offset.
Sélection & On-site Operation Notes
- Max effective distance is 4 m, not applicable beyond this range. Signal margin is more sensitive to dust at longer distances.
- Retro-reflective principle: Reflector shall not be covered by oil or dust for long periods, regular maintenance required.
- Use caution for highly reflective workpieces (polished metal): workpiece surface reflection may replace reflector and cause false triggering. For such scenarios, use diffuse or background suppression photoelectric sensors instead.
- Not recommended for fully transparent glass. OPTEX ZR-Q series dedicated transparent-object photoelectric sensor is preferred.
OPTEX Z2R-400N BOM List + PLC Wiring Example
- BOM List (Single Station)
| Non. | Description | Modèle | Remarques |
| 1 | Capteur photoélectrique rétro-réfléchissant | Z2R-400N | Unité principale, 4 m, NPN cable type |
| 2 | Reflector | V-61 | Original matching reflector for Z2 series; low-cost third-party reflective sheet is not recommended due to insufficient signal margin at long range |
| 3 | Sensor Mounting Bracket | BEF-W100-B | Metal bracket compatible with Z2 square housing, angle adjustable |
| 4 | Field Cable (User Supplied) | 4-core shielded cable 0.3~0.5 mm | Brown/Blue/Black/White; ordinary 4-core cable acceptable for short distance; shield grounding recommended for high interference environment |
| 5 | PLC Input Module | Japanese PLC (Mitsubishi / Omron) | NPN sink input module |
| 6 | Fastening Screws | M3/M4 | For bracket and reflector fixing |
Optional Replacement: If M8 connector version is required, replace sensor with Z2R-400CN4, matched with M8 4-core straight / angled cable.
- Schéma de câblage (Z2R-400N 4-core Cable)
| Couleur du fil | Définition | Instructions de câblage |
| Brun | DC10~30 V+ | Connect to positive terminal of power supply |
| Bleu | CC 0 V | Puissance négative, also connect to PLC COM terminal (sink input PLC) |
| Noir | NPN Signal Output | Connect to PLC input terminal Xn (signal) |
| Blanc | Operation Mode Selection Wire | 1. White wire open: Lumière allumée (output ON when light path is unobstructed; output OFF when light blocked) |
| 2. White wire connected to 0 V: Dark-ON (output ON when light blocked; output OFF when light unobstructed, most commonly used on production lines) |
PLC Wiring Key Points (Japanese Sink PLC, Mitsubishi FX / Omron)
- Alimentation: DC24V power supply feeds sensor; power negative connected to PLC COM terminal
- Signal circuit: Sensor black output wire → PLC input terminal X
- Recommended mode: White wire to 0V → Dark-ON. PLC receives ON signal when workpiece blocks light, suitable for position detection and counting.
- Load note: Sensor max output current is 100 mA. PLC input draws tiny current and can be directly connected. Do NOT drive solenoid valve directly.
- On-site Commissioning Procedure (Dark-ON Mode, for Transparent & Ordinary Workpieces)
- Complete wiring and power on. Align light beam to reflector until green stable indicator remains lit (good light alignment).
- Turn potentiometer clockwise to maximum sensitivity.
- Place test workpiece and verify change of orange operation indicator.
- Fine-tune potentiometer: Gradually reduce sensitivity to ensure stable triggering when workpiece blocks light and avoid false triggering caused by workpiece surface reflection.
Commissioning Tip for Transparent Film / PET Bottle: Lower sensitivity to reduce missed detection caused by light penetration.
- Program Logic Example (Mitsubishi FX Ladder Description)
Installation: X0 connected to Z2R-400N black signal wire (Dark-ON)
- Détection de position: `X0 ON` → Workpiece in position, activate Y0 position indicator
- Compte: Rising edge of X0 triggers counter C0, increment count by 1 for each workpiece
- Empty Material Alarm: Trigger missing package alarm Y1 when X0 stays OFF longer than preset time
- Notes complémentaires
- Mount reflector V-61 with surface perpendicular to sensor beam; inclination reduces effective sensing distance.
- For dusty working conditions, reserve maintenance access for reflector cleaning; oil contamination leads directly to light path failure.
- Not recommended for polished metal workpieces. Workpiece reflection may mimic reflector and cause false reading. Use background suppression photoelectric sensor for this case.
- Température de fonctionnement: -25~55℃. Heat insulation protection required for high-temperature baking environment.
- Z2R-400N VS Z4R-400N Application Comparison
| Article | Z2R-400N | Z4R-400N |
| Logement | Economical ABS square housing | Upgraded housing with higher impact resistance |
| Tache lumineuse | Standard spot | Small spot version for tiny object detection |
| Prix | Inférieur, preferred for mass production lines | Plus haut, for high-precision detection stations |
| Temps de réponse | ≤500 μs | ≤250 μs, suitable for high-speed lines |
| Scénarios d'application | General conveyor, packaging machine, tray position detection | High-speed sorting, small workpiece detection |
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur


















NH42-63-318x560.png)



