Phoenix 2981800 Safety Relay - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Phoenix 2981800 Safety Relay - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

électrique/

Phoenix 2981800 Safety Relay

  Model Segment Full Designation Description 2981800 Numéro de commande. Phoenix Contact global unique part number PSR PSR Phoenix Contact PSR series safety relay (Programmable Safety Relay) SCP SCP Safety function: dedicated for Emergency Stop / Safety Gate monitoring (Safety Control for E-Stop/Door) 24DC 24DC Control voltage: DC24V input ESD ESD Function feature: Emergency Stop Delay ...

  • Détails du produit

 

Segment de modèleFull DesignationDescription
2981800Numéro de commande.Contact Phénix global unique part number
PSRPSRPhoenix Contact PSR series safety relay (Programmable Safety Relay)
SCPSCPFonction de sécurité: dedicated for Emergency Stop / Safety Gate monitoring (Safety Control for E-Stop/Door)
24CC24CCTension de commande: DC24V input
ESDESDFunction feature: Emergency Stop Delay
4X14X1Configuration des contacts: 4 contacts (2 safety NO + 2 auxiliary NO), 1-channel safety input
3030Delay range: adjustable power-off delay 0.1s ~ 30s

Application principale: Single-channel safety relay for Emergency Stop and Safety Gate monitoring. It complies with safety rating SIL 3 / Cat.4 PL e, with 0.1–30s adjustable power-off delay. Suitable for protection scenarios of automated equipment requiring safety stop delay.

  1. Spécifications de base
Catégorie de paramètreSpécification détailléeRemarques
Safety PerformanceSafety Level: SIL 3 (CEI 61508)Meets highest industrial safety requirements
Niveau de performance: PL e, Catégorie 4 (EN ISO 13849-1)
PFHd: 2.5×10⁻⁸/h
Caractéristiques d'entréeTension de contrôle: DC24V (19.2~28.8V)Compatible with standard industrial 24V DC control systems
Courant d'entrée: Max 40mA
Input Channel: 1 safety input (NC/NO optional)
Mode de réinitialisation: Automatique / Manual selectable
Caractéristiques de sortieSafety Contacts: 2 pcs N/O (Force-guided)Force-guided safety contacts ensure fail-safe operation
Contacts auxiliaires: 2 pcs N/O
Contacter l'évaluation: AC-15: 230V/2,5A
DC-13: 24V/2,5A
Max Switching Voltage: 250V CA/CC
Max Switching Current: 6UN
Delay CharacteristicsPower-off delay: continuously adjustable 0.1s~30sAdapt to different equipment stopping time requirements
Setting Accuracy: ±10%
Caractéristiques physiquesDimensions: W22.5mm × H99mm × D121mmSingle-channel width, saves cabinet space
Poids: Environ. 0.22kilos
Montage: 35mm rail DIN (DANS 60715)
Câblage: Plug-in screw terminals
Environmental CharacteristicsTempérature de fonctionnement: -20~+60℃Industrial-grade environmental adaptability for harsh working conditions
Température de stockage: -40~+85℃
Humidité: 5~95%RH (sans condensation)
Résistance aux vibrations: 10~150Hz, 2g
Résistance aux chocs: 15g
Certifications de sécuritéCE, UL, ASC, TUV, ATEXConforme aux normes de sécurité internationales, globally applicable
  1. Liste des accessoires & Directives d'installation

3.1 Accessoires standards

Safety relay unit ×1

Installation manual ×1

Terminal marking label ×1

Fixing clip ×2 (for DIN rail locking)

Delay adjustment screwdriver ×1 (special tool)

3.2 Précautions d'installation

  1. Mounting Requirement: Install on standard 35mm DIN rail; maintain ≥5mm clearance from adjacent modules for heat dissipation.
  2. Spécification de câblage:

Circuit de contrôle: Connect DC24V to A1(+)、A2(-)

Safety Input: Connect E-stop / safety gate contact to S11S12 (NC contact preferred)

Safety Output: Connect safety circuit (par exemple. bobine de contacteur) à 13-14、23-24

Auxiliary Output: Connect alarm / indication circuit to 31-32、41-42

  1. Reset Setting:

Auto Reset: Automatically restore after power cycle

Réinitialisation manuelle: Requires external reset signal or manual reset button operation

  1. Delay Adjustment: Use the dedicated screwdriver to adjust the front panel potentiometer to set 0.1–30s power-off delay.
  2. Cross-model & Cross-brand Replacement

4.1 Phoenix Contact Same Series Alternative Models

Model No.Core DifferenceScénario d'application
29818001 canal, 2 sécurité + 2 contacts auxiliaires, 0.1–30s delayStandard E-stop / safety gate monitoring (current model)
29818011 canal, 2 sécurité + 2 contacts auxiliaires, 0.1–10s delayEquipment with short stopping time
29818021 canal, 2 sécurité + 2 contacts auxiliaires, 0.1–1s delayFast stop equipment
29818102 chaînes, 4 sécurité + 2 contacts auxiliaires, no delayDual-channel redundant safety system
29818201 canal, 2 sécurité + 2 contacts auxiliaires, with alarm outputSystem requiring alarm indication

4.2 Cross-brand Equivalent Solutions

MarqueModèleParamètres clésRemarque sur la compatibilité
SchneiderZelio SR2P121BD1 canal, 2 safety contacts, 24À DC, Cat.4Similar function, different wiring layout
Siemens3SK1111-1AB301 canal, 2 safety contacts, 24À DC, SIL 3Different dimensions, cabinet rearrangement required
OmronG9SA-321-T151 canal, 2 safety contacts, 24À DC, Cat.4Delay range 0.05–10s, slightly narrower
ABBMSR12751 canal, 2 safety contacts, 24À DC, SIL 3Higher price, fully identical function
WeidmüllerDRM570730LT1 canal, 2 safety contacts, 24À DC, Cat.4Fixed 1s non-adjustable delay

 

  1. Sélection & Directives de remplacement

5.1 Core Selection Criteria

✅ Safety Level Matching: Ensure required safety rating (SIL/PL/Cat.) does not exceed product capability (SIL 3 / Cat.4 PL e).

✅ I/O Requirement:

Saisir: 1 channel sufficient; confirm NC or NO contact type.

Sortir: Verify 2 sécurité + 2 auxiliary contacts meet control demands.

Capacité de contact: Ensure load current ≤2.5A (AC-15/DC-13).

✅ Delay Requirement: Confirm 0.1–30s adjustable range covers equipment stopping time.

✅ Reset Mode: Select auto or manual reset according to operation needs.

✅ Environmental Adaptation: Operating temperature ≤60℃ and humidity within industrial standard range.

5.2 Mise à niveau & Replacement Options

Option A: Same Series Function Upgrade

More channels: 2981800 → 2981810 (2 chaînes, 4 safety contacts)

Add alarm output: 2981800 → 2981820 (with alarm output)

Shorter delay: 2981800 → 2981801 (0.1–10s) ou 2981802 (0.1–1s)

Option B: Migrate from PSRclassic to PSRmini (Space Optimization)

Modèle de remplacement: 2981900 (PSRmini-SCP-24DC/ESD/4X1/30)

Avantage: Only 17.5mm width (5mm narrower), fonctions identiques, saves cabinet space.

Option C: Migrate from PSRclassic to PSRmodular (System Expansion)

Solution: PSRmodular system + safety function modules

Avantage: Multi-channel expandable; integrates safety gate, E-stop, light curtain and other safety functions, suitable for complex safety systems.

5.3 Dépannage courant

Phénomène de défautCause possibleSolution
Module indicator offControl power disconnected or faultyCheck DC24V input, measure voltage within 19.2~28.8V
No safety output actionSafety input loop openCheck E-stop / safety gate contact wiring and loop continuity
Abnormal delay timeImproper potentiometer adjustmentReadjust with dedicated screwdriver; calibrate with timer recommended
Échec de la réinitialisationIncorrect reset mode settingVerify auto/manual reset configuration and check reset signal
Adhérence par contactOverload current exceededMeasure load current; add intermediate relay if necessary

Contact Phénix 2981800 (PSR-SCP-24DC/ESD/4X1/30) is a single-channel safety relay with adjustable power-off delay, specially designed for emergency stop and safety gate monitoring, reaching the highest safety level SIL 3 / Cat.4 PL e. Its 22.5mm slim design and plug-in wiring facilitate installation and maintenance, while the 0.1–30s adjustable delay adapts to various equipment shutdown requirements. During selection, focus on safety rating, I/O configuration, delay range and reset mode. For upgrade, choose extended models in the same series or migrate to PSRmini / PSRmodular for space saving or system expansion.

Complete Model List of Phoenix Contact Safety Relays (Structured Classification)

  1. Model Naming Rule Overview
PréfixeCode de sérieMiddle CodeSignificationSuffixeSignification
PSRBasic identifier for Phoenix safety relaySCPE-stop / Safety Gate dedicated24CCControl voltage DC24V
PSRSafety RelaySPPStandard Safety ProtectionESDEmergency Stop Delay (0.1-30s)
PSRSafety RelayMCMini Compact4X1Contact: 4 NON (2 sécurité + 2 auxiliaire)
PSRSafety RelayMSMonitoring Safety30Delay time range (0.1-30s)
PSRSafety RelayUNIUniversal ConfigurablePIPush-in spring terminal
PSRSafety RelayMMMotion MonitoringSCBorne à vis
  1. PSRclassic Series (Standard Safety Relays)

2.1 E-Stop / Safety Gate (SCP Series)

ModèleNuméro de commande.Core ParameterSafety LevelApplication
PSR-SCP-24DC/ESD/4X1/3029818001Ch, 2Safety+2Aux, 0.1-30s delaySIL 3/Cat.4 PL eStandard E-stop / Safety Gate
PSR-SCP-24DC/ESD/4X1/1029818011Ch, 2Safety+2Aux, 0.1-10s delaySIL 3/Cat.4 PL eShort stop time equipment
PSR-SCP-24DC/ESD/4X1/129818021Ch, 2Safety+2Aux, 0.1-1s delaySIL 3/Cat.4 PL eFast stop equipment
PSR-SCP-24DC/ESD/5X1/1X2/30029814281/2Ch, 3Safety+1NC+2Aux, 0.1-300s delaySIL 3/Cat.4 PL eLong delay shutdown system
PSR-SCP-24UC/ESA4/3X1/1X2/B29637632Ch, 3Safety+1Aux, no delaySIL 3/Cat.4 PL eDual-channel redundant safety system
PSR-SCP-24DC/MXF3/4X1/2X2/B2903257Multi-Ch, 4Safety+2Aux, 3 safety functionsSIL 3/Cat.4 PL eMulti-function safety monitoring

2.2 Standard Safety Function (SPP Series)

ModèleNuméro de commande.Core ParameterSafety LevelApplication
PSR-SPP-24DC/SDC4/2X1/B29014261Ch, 2Safety contacts, no delaySIL 3/Cat.4 PL eBasic safety loop
PSR-SPP-230AC/ESAM2/3X1/1X2/B29014311Ch, 3Safety+1Aux, AC230VSIL 3/Cat.4 PL eAC power supply system
PSR-SPP-24UC/URM/3X1/3X229014271Ch, 3Safety+3Aux, universal voltageSIL 3/Cat.4 PL eMulti-voltage compatible system
PSR-SPP-24DC/ESD/3X1/1X2/3029814271Ch, 3Safety+1Aux, 0.1-30s delaySIL 3/Cat.4 PL eDelay-type safety system

2.3 Light Curtain Monitoring (SCR Series)

ModèleNuméro de commande.Core ParameterSafety LevelApplication
PSR-SCR-24DC/3X1/1X229815002Ch, 3Safety+1Aux, dedicated for light curtainSIL 3/Cat.4 PL eStandard light curtain monitoring
PSR-SCR-24DC/4X1/2X229815012Ch, 4Safety+2Aux, dedicated for light curtainSIL 3/Cat.4 PL eComplex light curtain safety system
PSR-SCR-24DC/5X1/1X229815022Ch, 5Safety+1Aux, dedicated for light curtainSIL 3/Cat.4 PL eHigh-density safety output

2.4 Two-Hand Control (SCT Series)

ModèleNuméro de commande.Core ParameterSafety LevelApplication
PSR-SCT-24DC/2X1/1X229816002Ch, 2Safety+1Aux, two-hand controlSIL 3/Cat.4 PL eStandard two-hand operation
PSR-SCT-24DC/3X1/2X229816012Ch, 3Safety+2Aux, two-hand controlSIL 3/Cat.4 PL eComplex two-hand operation
  1. PSRmini Series (Micro Compact, 17.5mm Width)

3.1 Basic Safety Function (Série MC)

ModèleNuméro de commande.Core ParameterSafety LevelApplication
PSR-MC32-3NO-1NC-24-230UC-SP27005251/2Ch, 3Safety+1NC, universal voltageSIL 3/Cat.4 PL eGeneral safety monitoring
PSR-MC34-3NO-1DO-24DC-SP27005481/2Ch, 3Safety+1diagnostic output, DC24VSIL 3/Cat.4 PL eSystem with diagnostic output
PSR-MC45-3NO-1DO-24DC-SC10820241Ch, 3Safety+1diagnostic output, DC24VSIL 3/Cat.4 PL eCompact E-stop system
PSR-MC22-2NO-1NC-24DC-SP27005001Ch, 2Safety+1NC, DC24VSIL 3/Cat.4 PL eSmall safety loop

3.2 Safety Monitoring Module (MS Series)

ModèleNuméro de commande.Core ParameterSafety LevelApplication
PSR-MS21-1NO-1DO-24DC-SC27021921Ch, 1Safety+1digital output, DC24VSIL 3/Cat.4 PL eSafety controller expansion
PSR-MS31-2NO-1DO-24DC-SP27022001Ch, 2Safety+1digital output, DC24VSIL 3/Cat.4 PL eSafety status monitoring
  1. PSRmodular Series (Modular Safety System)

4.1 Main Control Module

ModèleNuméro de commande.Core ParameterSafety LevelApplication
PSR-UNI-L-1X4NO-1DO-24DC-PI14876481/2Ch, 4Safety+1DO, configurableSIL 3/Cat.4 PL eUniversal configurable safety system
PSR-UNI-L-2X4NO-2DO-24DC-PI14876492Ch, 8Safety+2DO, configurableSIL 3/Cat.4 PL eComplex safety system
PSR-UNI-L-1X2NO-1NC-1DO-24DC-PI14876501/2Ch, 2Safety+1NC+1DOSIL 3/Cat.4 PL eSystem with NC output

4.2 Module d'extension

ModèleNuméro de commande.Core ParameterSafety LevelApplication
PSR-EXT-L-1X4NO-24DC-PI14876514-safety output expansionSIL 3/Cat.4 PL eOutput expansion
PSR-EXT-L-1X2NO-1NC-24DC-PI14876522Safety+1NC output expansionSIL 3/Cat.4 PL eMixed output expansion
  1. PSRmotion Series (Motion Monitoring Safety Relay)

5.1 Zero Speed / OverSpeed Monitoring

ModèleNuméro de commande.Core ParameterSafety LevelApplication
PSR-MM25-1NO-2DO-24DC-SC2702355Sensorless zero-speed monitoring, 3-moteur phaseSIL 3/Cat.3 PL eMotor zero-speed safety protection
PSR-MM35-1NO-2DO-24DC-SC2702356Overspeed monitoring, 3-moteur phaseSIL 3/Cat.3 PL eMotor overspeed safety protection
PSR-MM45-1NO-2DO-24DC-SC2702357Zero-speed + overspeed dual monitoring, 3-moteur phaseSIL 3/Cat.3 PL eFull motor speed monitoring

5.2 Rotation Direction Monitoring

ModèleNuméro de commande.Core ParameterSafety LevelApplication
PSR-MD25-1NO-2DO-24DC-SC2702360Rotation direction monitoring, 3-moteur phaseSIL 3/Cat.3 PL eMotor rotation direction safety control
  1. Safety Coupling Relays (PSR-SCP/SPP Series)
ModèleNuméro de commande.Core ParameterSafety LevelApplication
PSR-SCP-24DC/FSP/1X1/1X229817001Safety+1Aux contact, coupling functionSIL 3Safety signal isolation
PSR-SCP-24DC/FSP2/2X1/1X229817012Safety+1Aux contact, coupling functionSIL 3Dual-channel safety isolation
PSR-PS21-1NO-1NC-24DC-SC29817021Safety+1NC contact, coupling functionSIL 3Safety signal switching
  1. Key Selection Parameter Comparison
Catégorie de paramètreKey IndexConseils de sélection
Safety LevelSIL 1-3, Cat.1-4, PL a-eDetermined by equipment risk assessment; max support SIL 3/Cat.4 PL e
Input Channel1 Channel / 2 ChannelSingle channel for basic safety; dual channel for redundant safety
Configuration des contactsQuantity of safety / contacts auxiliaires≥2 safety contacts recommended; auxiliary contacts for alarm & indication
Tension de contrôleDC24V / AC230V / UniverselMatch on-site control system power supply
Function FeatureDelay / Diagnostic / Cross-circuit detectionE-stop requires delay; complex system needs diagnostic function
Mounting Width17.5mm / 22.5mm / 27.5mmChoose PSRmini (17.5mm) for limited cabinet space
Type de câblageVis / Push-in springPush-in for frequent wiring; screw type for vibration environment
  1. Notes complémentaires

8.1 Series Positioning

PSRclassic: Standard type with complete functions, width starting from 22.5mm, suitable for conventional safety applications.

PSRmini: Micro compact type, only 17.5mm width, saves cabinet space.

PSRmodular: Configurable modular system, suitable for complex safety systems with expandable functions.

PSRmotion: Dedicated for motion monitoring, applicable to motor zero-speed / overspeed / rotation direction safety control.

8.2 Informations de remplacement

Old models are gradually phased out; priority recommended to select models manufactured after 2020.

Some models are discontinued; refer to Phoenix Contact official website or technical support for replacement.

8.3 Safety Certification

Full series certified by CE, UL, ASC, TUV, conforme à la CEI 61508 and EN ISO 13849-1.

Partial models with ATEX certification for explosive atmosphere applications.

Précédent:

Suivant:

Laisser une réponse

Laisser un message