Schneider BMXDDI3202KH Digital Input Module

Série: Modicon X80 (Automate M340) Explication du modèle: BMXDDI3202KH = BMXDDI3202K + H; H = Conformal Coating version for harsh environments. Electrical specifications are identical to BMXDDI3202K. Only the PCB is coated with conformal coating for moisture-proof, mould-proof and salt-spray resistance, suitable for ports, chemical plants, underground sites, high-humidity and dusty conditions. ✅ Basic Specifications Type: ...

  • Détails du produit

Série: Modicon X80 (Automate M340)

Explication du modèle: BMXDDI3202KH = BMXDDI3202K + H; H = Conformal Coating version for harsh environments. Electrical specifications are identical to BMXDDI3202K. Only the PCB is coated with conformal coating for moisture-proof, mould-proof and salt-spray resistance, suitable for ports, chemical plants, underground sites, high-humidity and dusty conditions.

✅ Spécifications de base

Taper: 32-channel isolated digital module d'entrée, Couler (positive logic)

Tension d'entrée: 24VCC, sensor supply range 19~30VDC

Input current per channel: 2.5mA @24V

Logique 1: ≥11V / ≥2mA; Logique 0: ≤5V / ≤0.5mA

Impédance d'entrée: 9600Oh

Temps de réponse: Typical 4ms, maximum 7ms

Isolement: Channel-to-channel isolation, résistance d'isolement >10MΩ at 500VDC

Câblage: Compatible avec 2 fils / 3-wire proximity switches (IEC61131-2 Type3, IEC60947-5-2). Input parallel connection is not allowed

Connecteur: Single 40-pin FCN interface, single slot, hot-swap supported

Consommation d'énergie: ≤3.9W; Typical backplane 3.3V consumption 121mA

Protection du boîtier: IP20

📌 Matching Cables (40-pin FCN)

  1. BMXFCWxxx3: Pre-wired loose cables (3m/5m/10m: BMXFCW303 / BMXFCW503 / BMXFCW1003)
  2. BMXFCCxxx3: Pre-assembled HE10 terminal cables (0.5/1/2/3/5/10m)

🧩 Compatible CPUs

Full Modicon M340 series: BMXP34xx00, BMXP34xx20 (including H versions). General X80 rack, configured via Unity Pro software.

⚖️ Model Comparison

BMXDDI3202K: Version standard, pas de vernissage, for conventional control cabinets

BMXDDI3202KH: Conformal coated version for harsh environments. Fully interchangeable in program, pinout and cabling.

📎 Alternative Selection Reference

Same-platform replacement: No drop-in equivalent. For fewer points, refer to BMXDDI1602K(H) (16-point Sink DI).

Remplacement domestique: Verify sink logic, isolation and filter time, suitable for domestic PLC remote IO modules.

⚠️ Troubleshooting Tips

  1. Aucun signal d'entrée: Check 24V supply, sensor polarity (Couler, signal connects to 0V), broken pins in prefabricated cables.
  2. Clignotant / faux déclenchement: Check voltage drop and shielding. This module uses fixed hardware filter; filter parameters cannot be modified by software.
  3. Prefer KH version for humid and corrosive environments; standard K version is prone to PCB corrosion under long-term high humidity.

Schneider Entrée numérique (DEPUIS) Module List by Platform

Note: Suffix H = Conformal coating for harsh environments. X80 platform compatible with M340 / M580; Sink = sinking input, Source = sourcing input; AC = AC input.

  1. Modicon X80 (BMX series, M340 / M580)

DC Digital Input (BMXDDI)

ModèlePointsDescription
BMXDDI1602K / BMXDDI1602KH1624VCC, Couler
BMXDDI1603K / BMXDDI1603KH1648VCC, Couler
BMXDDI1604T16125VCC, Couler, température large
BMXDDI3202K / BMXDDI3202KH3224VCC, Couler (the model you enquired)
BMXDDI3203K / BMXDDI3203KH3248VCC, Couler
BMXDDI3232K / BMXDDI3232KH3212/24VCC, Sink/Source configurable
BMXDDI6402K / BMXDDI6402KH6424VCC, Couler

AC Digital Input (BMXDAI)

ModèlePointsDescription
BMXDAI08058220ACC
BMXDAI08148100~120VAC
BMXDAI16021624VAC/24VDC, Source
BMXDAI16031648ACC
BMXDAI160416100~120VAC
BMXDAI161416220ACC

X80 Safety DI (Safety PLC dedicated)

ModèlePointsDescription
BMXSDI160216Safety digital input, 24VCC
  1. TM3 Series (Expansion for M221/M241/M251/M262 Compact PLC)
ModèlePointsDescription
TM3DI8824VCC, bornes à vis
TM3DI8G824VCC, spring clamp terminals
TM3DI8A8120ACC
TM3DI161624VCC, bornes à vis
TM3DI16G1624VCC, spring clamp terminals
TM3DI16K1624VCC, HE10 connector
TM3DI32K3224VCC, HE10 connector
  1. Advantys STB Distributed Remote IO
ModèlePointsDescription
STBDDI37251624Évier VDC
STBDDI3420824Évier VDC
STBDDI3610424Évier VDC
STBDAI02002100~240 VCA
STBDAI04004100~240 VCA
  1. Notes complémentaires
  2. X80 naming rule: `BMXDDI` = DC DI; `BMXDAI` = AC DI; `K` standard, `KH` conformal coated.
  3. K and KH variants of the same model are fully interchangeable in pinout, programming and backplane interface, only differing in PCB protection.
  4. Mixed I/O modules (DI+FAIRE) such as BMXDDM16022 are excluded from this table.

Application Scenarios of Schneider Digital Input (DEPUIS) Modules (X80/STB/TM3, etc.)

Core function of DI modules: Collect binary switch signals, transfer ON/OFF status from external dry contacts, capteurs, boutons-poussoirs, limit switches and auxiliary contacts of contactors to PLC. It only detects on/off status and does not process analog signals. The following is sorted by industry and signal type, applicable to BMXDDI3202KH and other X80 modules.

  1. General Signal Acquisition (Used across all industries)
  2. Boutons poussoirs, sélecteurs, boutons d'arrêt d'urgence

Local cabinet operation, remote control boxes, E-stop signals (general E-stop; safety E-stop should use dedicated safety DI module BMXSDI1602).

  1. Fins de course, commutateurs de voyage, détecteurs de proximité, capteurs photoélectriques

Equipment position detection: cylinder confirmation, door switches, baffle limit for material level, object presence detection.

BMXDDI3202KH is 24VDC Sink, compatible with mainstream NPN proximity switches.

  1. Auxiliary contacts of contactors / relais, circuit breaker status feedback

Motor running feedback, VFD ready feedback, circuit breaker open/close status, thermal relay fault signals.

  1. Dry contact signals

Fire alarm systems, contrôle d'accès, damper/valve position feedback in HVAC, float level switches.

  1. CVC

En cours d'exécution / fault feedback of fans and water pumps

Pressostats différentiels, frost protection switches, air damper / water valve end-position feedback

Alarme de pression différentielle du filtre, high/low float level switches

Feedback of smoke exhaust dampers and fire dampers

Conformal coated KH versions (BMXDDIxxxxKH) are preferred for humid and dusty machine rooms.

  1. Traitement de l'eau, Approvisionnement en eau & Drainage, Usines de traitement des eaux usées

Level switches (high level, niveau bas, overflow)

Pump run, faute, hand-auto status

Limit signals for bar screens and sludge scrapers

Pulse signals from flow meters (high-speed pulses require dedicated high-speed counter modules; standard DI is not suitable for high-frequency pulses)

Vanne ouverte / retour d'information en position fermée

KH coated modules are widely used in corrosive, high-humidity wastewater sites.

  1. Conditionnement, Lignes d'assemblage & Lignes de production automatisées

Photoelectric detection for material presence / missing material

Cylinder and clamp confirmation signals

Conveyor belt jam and deviation switches

Barcode detection, silo level switches

Safety gate and guard door status signals

BMXDDI6402K (64-point DI) is commonly used for high-point-count lines to save slots.

  1. Crane Systems, Convoyage & Warehouse Logistics

Crane travel limits, upper/lower hard limits, buffer switches

Palette en position, bay detection

Roller conveyor deviation and E-stop loop feedback

Roller shutter and guard door status

  1. Power Distribution Rooms & Energy Monitoring

Circuit breaker and disconnector open/close position feedback for high-voltage cabinets

Verrouillage de porte d'armoire, earthing switch status

Transformer thermostat switches, cooling fan feedback

DC panel fault alarm dry contacts

BMXDAI AC DI modules are often used for 220VAC cabinet signals.

  1. Huile & Gas, Industrie chimique, Ports (Environnements difficiles)

Valve position feedback, pump status, dry contact output of combustible gas detectors

Limit switches and door interlocks for trestle and quay equipment

Salt spray, high humidity and condensation → select KH conformal coated versions (BMXDDI3202KH etc.). Standard K versions are vulnerable to corrosion.

  1. Automatisation des bâtiments, Protection incendie & Pumping Stations

Dry contact alarms from fire host, sprinkler pressure switches

Elevator interlock signals, smoke exhaust fan status

Rainwater pumps, sump tank level monitoring

✅ Quick Selection Guide by Scenario

Normal indoor control cabinet, environnement sec: BMXDDIxxxK

Chimique / port / humidité élevée & brouillard salin: BMXDDIxxxKH (revêtement conforme)

220VAC contact signals: BMXDAI AC DI

Circuits de sécurité, barrières de sécurité, safety E-stop: BMXSDI safety DI

Petites machines, low I/O count: TM3DI series

Distributed remote IO with scattered field points: STB Advantys remote DI

⚠️ Scope Limitations (What DI modules cannot do)

  1. Cannot directly measure 4-20mA or temperature (AI analog modules required)
  2. Standard DI is not suitable for high-frequency pulse counting (high-speed counter module required)
  3. Safety functions shall not be implemented via ordinary DI; dedicated safety DI modules are mandatory.