Siemens 3RH1921-1HA22 Contactor Side-Mount Accessory - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 Siemens 3RH1921-1HA22 Contactor Side-Mount Accessory - Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur

contacteur/

Siemens 3RH1921-1HA22 Contactor Side-Mount Accessory

Nom complet du produit: SIRIUS side-mounted auxiliary switch block, 4-pôle, 2NON+2NC, screw terminals Product Status: Discontinué (PLM PM500). It is an older accessory for 3RT1 contactors. The new-generation replacement series is 3RH29xx Model Nomenclature 3RH: SIRIUS auxiliary switches / contactor relay accessories 19: External side-mounted auxiliary contacts for contactors 21: Side snap-on mounting, fits S0~S3 contactor ...

  • Détails du produit

Nom complet du produit: SIRIUS side-mounted auxiliary switch block, 4-pôle, 2NON+2NC, bornes à vis

Statut du produit: Discontinué (PLM PM500). It is an older accessory for 3RT1 contacteurs. The new-generation replacement series is 3RH29xx

  1. Nomenclature du modèle

3RH: SIRIUS auxiliary switches / contactor relay accessories

19: External side-mounted auxiliary contacts for contactors

21: Side snap-on mounting, fits S0~S3 contactor sizes

1: Bornes à vis; 2 = spring-cage terminals (3RH1921-2HA22)

HA: 4-pole side-mounted contact block

22: Configuration des contacts 2 Normalement ouvert + 2 Normalement fermé (2NON+2NC)

  1. Paramètres techniques clés
  2. Contacts: 2NON+2NC, 4-pôle, conforme à la norme EN 50012
  3. Montage: Snap-on side installation on the contactor
  4. Compatible base unit: SIRIUS 3RT1 motor contactors, frame sizes S0 / S2 / S3
  5. Terminaux: Type de vis, wire cross-section 0.5~2.5 mm²
  6. Protection: Front face IP20
  7. Tension d'isolement nominale: 690 V (degré de pollution 3), impulse withstand voltage 6 kV
  8. Endurance: Durée de vie mécanique 10 millions de cycles de manœuvres; AC-15 230V electrical life 200,000 cycles
  9. Température de fonctionnement: -25 ~ +60 °C; température de stockage: -55 ~ +80 °C
  10. Contact reliability: 17 V / 1 mA, maximum 1 failure within 100 millions d'opérations
  11. Scénarios d'application

Side expansion of auxiliary contacts for 3RT1 (S0~S3) Contacteurs CA

PLC feedback signals, indication d'état, circuits de verrouillage, fault signal output

Motor start-stop control circuits, ventilateur & water pump control panels, low-voltage switchgear cabinets

Note: Side auxiliary switches can only be fitted on the left side of the contactor. The total number of NC contacts is limited; positively driven contacts must be verified for safety interlock applications.

  1. Sélection de remplacement (Discontinued Upgrade)

Original model discontinued. The corresponding side-mounted unit for new 3RT2 (S0~S3) contacteurs:

3RH2921-1DA22 (borne à vis, 2NO+2NC side-mounted auxiliary switch)

  1. Dépannage & Inspection Guidelines
  2. Common failures: Contacter l'oxydation, contact burning, loose snap-fit clips leading to intermittent feedback signals
  3. Multimeter test: With the contactor de-energized, NC contacts shall be conducting and NO contacts open; contact status flips when the coil is energized
  4. Vérification du câblage: Tighten all terminal screws firmly; loose thin wires frequently cause unstable PLC digital inputs
  5. Remplacement: Direct snap-on disassembly without touching the main power circuit; always test interlock logic after replacement
  6. Cross-reference List for the Same Series

3RH1921-1HA22: Bornes à vis, 2NON+2NC, side mount S0–S3 (Discontinué)

3RH1921-2HA22: Bornes à ressort, same contact configuration (Discontinué)

3RH2921-1DA22: New-generation screw-type side-mounted 2NO+2NC (Modèle de remplacement)

Siemens 3RT1 Contactor Replacement Overview

3RT1 (S00~S3, ≤95A) est interrompu (PLM PM500). First-choice official direct replacement: 3RT2 (imported SIRIUS Innovation series). For cost-saving domestic alternatives, select 3RT6 / 3RT5. Larger frame 3RT1 (>95UN) remains available with no forced phase-out schedule

  1. 3RT2 [Importé, Preferred OEM Replacement]

Série: 3RT20xx, direct replacement for legacy 3RT10xx

Frame size match: S00 / S0 / S2 / S3, AC-3 current range 7A~95A

Règle de remplacement:

Exemple: 3RT1024-1BB40 → 3RT2024-1BB40. Keep coil voltage and rated current unchanged; only change the middle digit from 1 à 2.

Critical compatibility note (relevant to your 3RH1921 auxiliary contacts):

Old 3RH1921 cannot be used on 3RT2; you must upgrade to 3RH2921 series auxiliary switches together with the contactor body.

  1. Large-size 3RT1 (S6 / S10 / S12, Still Active, Not Discontinued)

S6 (3RT105×, Frame S6, 115UN ~ 150A, 55kW~75kW @400V)

Base Order No.Courant AC-3Puissance du moteur (400V)Type de borneAccessoires assortis
3RT1054115 UN55 kWVis / box terminalsContact auxiliaire: 3RH1951; Overload relay: 3RU1156
3RT1055150 UN75 kWVis / box terminalsContact auxiliaire: 3RH1951; Overload relay: 3RU1156

Complete model examples: 3RT1054-6AF36, 3RT1055-6NB36

S10 (3RT106×, Cadre S10, 185A~225A, 90kW~110kW @400V)

Base Order No.Courant AC-3Puissance du moteur (400V)Type de borneAccessoires assortis
3RT1064185 UN90 kWBusbar terminalsContact auxiliaire: 3RH1961; Overload relay: 3RU1166
3RT1065225 UN110 kWBusbar terminalsContact auxiliaire: 3RH1961; Overload relay: 3RU1166

S12 (3RT107×, Cadre S12, 265A~300A, 132kW~160kW @400V)

Base Order No.Courant AC-3Puissance du moteur (400V)Type de borneAccessoires assortis
3RT1075265 UN132 kWBusbar terminalsContact auxiliaire: 3RH1971; Overload relay: 3RU1176
3RT1076300 UN160 kWBusbar terminalsContact auxiliaire: 3RH1971; Overload relay: 3RU1176

S14 (Extra-large frame, still available)

3RT1096: 400UN / 200kW

3RT1097: 500UN / 250kW

  1. Dedicated Accessories for S6/S10/S12 (Not Interchangeable with S00~S3)

(1) Side-mounted auxiliary switches (Base unit already has built-in 2NO+2NC; add-on optional)

S6: 3RH1951

S10: 3RH1961

S12: 3RH1971

Important reminder: 3RH1921 (for small frames) cannot be installed here due to incompatible snap-in geometry.

(2) Plug-in thermal overload relays (direct plug-on mounting with 3RT1)

S6: 3RU1156

S10: 3RU1166

S12: 3RU1176

(3) Mechanical interlocks (pour paires de contacteurs inverseurs)

S6: 3RT1951

S10: 3RT1961

S12: 3RT1971

  1. Coil Voltage Suffix Codes (Universal for all frames)

1AB36: CA/CC 24 V

1AD36: CA/CC 48 V

6AF36: AC/DC 110~127 V

6AU36: AC/DC 200~277 V (bobine à large tension)

  1. Phase-out Boundary Rules (Critique)
  2. 3RT101~3RT104 (S00~S3, ≤95A): PM500, fully discontinued. Must migrate to 3RT2 / 3RT6.
  3. 3RT105~3RT107 (S6/S10/S12): PM300, active production, long-term supply, no end-of-life plan.
  4. Future upgrade path (if needed): 3RT105 → 3RT205; 3RT106 → 3RT206; 3RT107 → 3RT207. Replace accessories with 3RH2951/2961/2971 accordingly.
  5. Popular Complete Order Numbers
  6. 3RT1054-6AF36|S6, 115UN, AC/DC 110V coil
  7. 3RT1055-6NB36|S6, 150UN, bobine à large tension
  8. 3RT1064-6AU36|S10, 185UN, AC/DC 240V coil
  9. 3RT1065-6AU36|S10, 225UN, AC/DC 240V coil
  10. 3RT1075-6AU36|S12, 265UN
  11. 3RT1076-6AU36|S12, 300UN

Précédent: