Module de base de contrôleur Siemens 6ED1052-1FB08-0BA2 - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Module de base de contrôleur Siemens 6ED1052-1FB08-0BA2 - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

électrique/

Module de base de contrôleur Siemens 6ED1052-1FB08-0BA2

Siemens 6ED1052-1FB08-0BA2 (LOGO!230RCE V8.4) Application Scenarios Key characteristics: Direct 230 V AC supply, sorties relais, on-board display, Ethernet (MQTT / Modbus-TCP / embedded web pages), multiplexable 0-10 V analog inputs. Suitable for small-I/O-count logic control with 220 V supply and remote monitoring requirements. Programmed via graphical function-block editor without complex PLC programming. Native I/O: 8 DEPUIS / 4 ...

  • Détails du produit

Siemens 6ED1052-1FB08-0BA2 (LOGO!230RCE V8.4) Scénarios d'application

Key characteristics: Direct 230 V AC supply, sorties relais, on-board display, Ethernet (MQTT / Modbus-TCP / embedded web pages), multiplexable 0-10 V analog inputs. Suitable for small-I/O-count logic control with 220 V supply and remote monitoring requirements. Programmed via graphical function-block editor without complex PLC programming. Native I/O: 8 DEPUIS / 4 FAIRE; expandable with LOGO!8-series expansion modules.

Full Designation: LOGO! 230RCE Logic Controller Base Module, avec affichage, Ethernet, Sortie relais, 115-230 V AC/DC Supply

  1. Model Code Decoding
Segment de codeDescription
6ED1052LOGO! base main unit series
1With display; 0 = without display
FBPower supply type: FB = 115‑230 V AC/DC, Sortie relais(R.)
8Version du matériel 08 (LOGO! 8 hardware platform)
0BA2Firmware version: V8.4 (supports MQTT, Web‑Server, Micro‑SD Card)
  1. Spécifications électriques de base
ArticleParamètre
Tension d'alimentation100‑253 V AC/DC (nominal 115/230 V), 47‑63 Hz
Digital Inputs DI8‑channel (I1‑I8); I1/I2/I7/I8 are multiplexable for 0‑10 V analog inputs
Digital Outputs DO4‑channel relay outputs Q1‑Q4
Charge résistive: 10 A per channel; Inductive load: 3 A per channel
⚠️ Outputs have no built‑in short‑circuit protection; external fuses are mandatory
Capacité du programmeMax.. 400 function blocks; Real‑time clock backup 480 h for retaining timer parameters upon power loss
Interface de communication1×RJ45 Ethernet; Prise en charge: LOGO! internal protocol, Modbus‑TCP, MQTT, built‑in Web‑Server, enregistrement de données, custom web pages
StockageMicro‑SD card slot (program backup, firmware upgrade)
Logiciel de programmationLOGO! Soft Comfort V8.4 or higher
Montage35 mm DIN‑rail mounting
Dimensions hors toutW71.5 × H90 × D60 mm, IP20
Ambient Operating Temperature‑20 ℃ ~ +55 ℃; Stockage: ‑40 ℃ ~ +70 ℃
CertificationsCE, UL, FM, RoHS
  1. Matériel & Remarques sur le câblage
  2. Input terminals I1-I8 are universal AC/DC inputs matched to the 115-230 V supply rating. When I1/I2/I7/I8 are software-enabled as 0-10 V AI, these terminals shall receive voltage signals and must NOT be connected to high-voltage mains.
  3. Relay outputs are potential-free contacts; common terminals can be wired to circuits of different voltage levels. Pour charges inductives (contacteurs, électrovannes), RC snubber circuits must be connected in parallel.
  4. LAN port: For programming, remote web-based monitoring, MQTT cloud uplink; built-in web pages are accessible directly via web browser.
  5. SD-Card: Importer / export programs & logs, perform firmware upgrade.

⚠️ Critical Prohibitions

Do not exceed ratings: 10 A resistive / 3 A inductive for relay outputs. Do not drive high-power motors directly. External fuses are required.

When channels are multiplexed for analog input (0-10 V), applying AC230 V will destroy input circuitry.

Indice IP20: For cabinet-mount use only. Not for outdoor installation, condensing or corrosive environments.

  1. Compatible Replacement Options

Direct drop-in replacement: `6ED1052-1FB08-0BA2` (LOGO! V8.4, current order reference)

Legacy compatible variant: `6ED1052-1FB08-0BA1` (V8.3, identical pin-out, backward-compatible program; older firmware lacks MQTT features)

Note: LOGO!8.x (0BA8) base units are NOT compatible with legacy 0BA7 / 0BA6 expansion modules. Use LOGO!8-series expansions only (par exemple. 6ED1055-1FB00-0BA2).

  1. Scénarios d'application typiques

Automatisation des bâtiments: contrôle de l'éclairage, ventilateur & pump management, CVC, auxiliary access-control logic; stand-alone simple machine control; agricultural irrigation; interlock logic for packaging machinery; IoT edge data acquisition, MQTT uplink to SCADA / cloud platforms.

  1. Contenu du paquet

Main unit ×1

Printed quick-start manual ×1

❗ Excluded: Ethernet cable, SD-card, external fuses, expansion modules (commander séparément).

5.1 Building HVAC (Primary Use-Case)

  1. Contrôle du ventilateur: Exhaust fans, fresh-air supply-fan interlocks; scheduled start-stop, differential-pressure trigger, alarme de panne; web-based remote status visualization.
  2. Contrôle de la pompe: Domestic-water / circulation pumps with duty-standby automatic change-over, overload alarm, water-level interlocking.
  3. Lighting-control system

Scheduled lighting for workshops, underground car-parks and public corridors; PIR trigger, holiday calendar scheduling.

Fire-alarm interlock for lighting cut-off; upload lighting status via Ethernet to central control room.

  1. Air-handling unit & damper control: Damper actuators, heater simple logic; 0-10 V channels acquire temperature / humidity transmitters for basic closed-loop regulation.
  2. Cooling-tower & roof ventilation: Local logic plus remote web monitoring; MQTT data upload to building BA-system.

Avantages: No separate 24 V power supply required for 230 V operation; built-in web-server removes need for dedicated SCADA for browser-based supervision.

5.2 Stand-alone Simple Machine Control

For low-I/O machinery where full-scale PLC is not justified

  1. Packaging auxiliary equipment: Conveyor start-stop interlocks, silo level detection, indicateurs d'alarme, timed discharging cycles.
  2. Injection-molding auxiliary & cooling units: Cooling-fan / circulation-pump logic; 0-10 V temperature acquisition, fault-alarm output.
  3. Air-compressor auxiliary control: Exhaust-fan, timed solenoid drain valve, aggregated fault-signal output.
  4. Gate / roller-shutter / lifting-door logic: Limit-switch monitoring, interlocks, time-delay, manual-auto mode switching.

⚠️ Limitation: Max.. 3 A inductive rating for relay contacts; use intermediate relays for large contactor coils. Not applicable for high-speed pulse-based motion control.

5.3 Agriculture & Traitement de l'eau

  1. Greenhouse simplified automation: Ventilateur & shade-blind actuation; 0-10 V temperature-humidity acquisition; timed irrigation solenoids; MQTT upload to IoT platform.
  2. Small-scale wastewater / reclaimed-water equipment: Pump rotation scheduling, high-low level interlocks, timed chemical-dosing, alarm outputs.
  3. Fountains & water-feature installations: Cyclic multi-pump sequencing, fault-alarm logic.

5.4 Electrical Cabinet & LV Panel Auxiliary Logic

  1. Low-voltage switchgear auxiliary logic: Bus-coupler interlocking, cabinet cooling-fan control, cabinet-door status acquisition, collective fault-alarm output.
  2. PV / energy-storage auxiliary cabinets: Cabinet-heater / dehumidifier & cooling-fan temperature-driven / timed control; alarm telemetry over Ethernet.
  3. UPS emergency-power auxiliary logic: Mains-failure detection, switching logic, audible-visual alarm outputs.

5.5 IoT Edge Acquisition (V8.4-Exclusive MQTT Feature)

Core enhancement versus older V8.3 (-0BA1 firmware):

  1. Acquire digital status and 0-10 V analog measurements; transmit via MQTT to private / public cloud servers (par exemple. Alibaba Cloud).
  2. Operate as Modbus-TCP slave for connection to HMI / host supervisory systems. Built-in web-server for PC / mobile-browser status access without dedicated software.
  3. Micro-SD-card data logging: record temperature, runtime timestamps; export CSV files for maintenance review.

❌ Non-Applicable Scenarios (Selection Pitfalls)

  1. High-speed counting, pulse-output, servo motion control: Not supported by LOGO!.
  2. Large I/O quantity: Native 8DI /4DO; maximum expandable to 24DI /16DO. For larger systems select S7-1200 PLC.
  3. Frequent switching of heavy inductive loads: Limited mechanical relay contact life; use transistor-output variants for high-cycle applications.
  4. Hazardous / explosive-risk zones: IP20 unit must be installed inside certified explosion-proof enclosures; cannot be mounted directly in Zone1/Zone2.
  5. High-precision PID closed-loop control: Only basic PID function-block available; use standard PLC for demanding closed-loop performance.

Typical System Configuration Examples

Temperature acquisition: Multiplex I1 as 0-10 V AI for connection to temperature transmitter.

Contactor driving: LOGO! relay output → intermediate relay → contactor coil.

Surveillance à distance: RJ45 LAN to local network; access embedded web-server via browser.

Extension d'E/S: 6ED1055-1FB00-0BA2 (230 V relay expansion module).

Siemens 6ED1052-1FB08-0BA2 (LOGO!230RCE V8.4) Full Technical Datasheet

Full Designation: LOGO! 230Module de base du contrôleur logique RCE, avec affichage, Ethernet, Sortie relais, 115-230 V AC/DC, Firmware V8.4 with MQTT support

Power Supply Ratings

ArticleSpécification
Tension d'alimentation100‑253 V AC / CC (nominal 115‑230 V AC/DC)
AC Frequency Range47‑63 Hz
Consommation d'énergieEnviron. 3.5 W
RTC Backup Duration480 h (20 days); retains real‑time clock and timer parameters after power loss

I/O Terminal Specifications

ArticleSpécification
Digital Inputs DI8‑channel (I1‑I8); rated for 115‑230 V AC/DC signals.
I1, I2, I7, I8 software‑configurable as 0‑10 V analog inputs (IA), 10‑bit resolution
Digital Outputs DO4‑channel potential‑free relay outputs Q1‑Q4
Charge résistive: 10 A per channel; Inductive load: 3 A per channel
⚠️ No built‑in short‑circuit protection; external fuses are mandatory
Type de sortieMechanical relay contacts; common terminals can be assigned to different voltage domains
Max.. Expanded I/OUnité de base + LOGO!8 expansion modules: Max.. 24DI /16DO

Program & Mémoire

ArticleSpécification
Max.. Function Blocks400 blocks (depends on block type)
Logiciel de programmationLOGO! Soft Comfort V8.4 or higher
Storage MediaMicro‑SD card slot: program backup, firmware update, CSV‑format data log export
Afficher6‑line backlit LCD; local push‑buttons for parameter modification & status review

Interface de communication (RJ45 Ethernet 10/100 Mbit/s)

LOGO! native protocol (programmation, multi-LOGO! LAN networking)

Modbus-TCP (Maître / Esclave)

MQTT Client (V8.4 new feature, for private / public cloud connection)

Embedded Web-Server: browser-based supervision, custom web pages, enregistrement de données, email alarm notification

❗ Does NOT support Profinet, CANopen, KNX.

Mécanique & Montage

ArticleSpécification
Montage35 mm standard DIN‑rail (4‑module width)
Dimensions hors toutW71.5 mm × H90 mm × D60 mm
Protection contre la pénétrationIP20 (cabinet‑installation only)
PoidsEnviron. 200 g

Conditions environnementales

ArticleGamme
Température ambiante de fonctionnement‑20 ℃ ~ +55 ℃ (inside control cabinet)
Stockage & Température de transport‑40 ℃ ~ +70 ℃
Humidité relative5 %‑95 % RH, condensation not permitted
Vibration & ChocCompliant with IEC60068‑2‑6 / IEC60068‑2‑27 industrial standards

Approvals & CEM

Certifications: CE, UL, FM, RoHS

CEM: EN55011 Class B (residential environment), EN61000-6-2 industrial immunity

Critical Limitations (Selection Constraints)

  1. Relay outputs are not suitable for high-cycle switching; intermediate relays must be used for heavy loads.
  2. When channels are configured for 0-10 V analog input, AC230 V mains must never be connected, as input hardware will be destroyed.
  3. No native high-speed counter, pulse-output or motion-control functions.
  4. Only LOGO!8-series expansion modules (order suffix-0BA2) are compatible; legacy 0BA7 / 0BA6 expansions will not work.
  5. No internal short-circuit protection; external fuses are required for all relay-output circuits.

Firmware Variant Comparison

6ED1052-1FB08-0BA1: V8.3, identical hardware pin-out; no MQTT, limited web-server capability.

6ED1052-1FB08-0BA2: V8.4, adds MQTT, enhanced web-server and improved email-alarm functions; current active ordering reference.

Précédent:

Suivant:

Laisser une réponse