상표: SAMWHA EOCR (슈나이더 한국)

제품 유형: EOCR-SS Series Knob-type Electronic Motor Protector (Replaces traditional thermal overload relays)

  1. Model Code Breakdown of EOCRSS-60NW7PQ
분절암호정의
EOCRSS시리즈SS Economy Integrated Through-Core Motor Protector
60현재 등급Built-in CT, adjustable rated current: 5.0~60A, compatible with 1.5~30kW three-phase motors
N보호 모드Type N Fail-Safe: Contacts open and contactor trips upon protector power loss or fault; Type R does not trip when power fails
W7전원공급장치W7 = Wide Voltage AC 180~480V (Suitable for 380/400/440V industrial three-phase power grids)
연락처 구성P = Standard changeover contacts: 95(NC)/97(아니요) (1 평상시 열림 + 1 평상시 닫힘)
추가 기능Q = Built-in Modbus-RTU RS485 communication; supports PLC/DCS remote monitoring, real-time current reading and fault code retrieval
  1. EOCR-SS Series Knob-type Electronic Motor Protector핵심 기술 사양

3.1 현재의 & Time Adjustment

현재 범위: 5~60A (10:1 wide adjustment ratio)

D-타임 (Start Stall Delay): 0.2~30s adjustable to avoid false tripping caused by high motor starting current

O-타임 (Overload Trip Delay): 0.2~30s adjustable to match motor thermal characteristic curves

3.2 보호 기능

  1. 초과 적재 & 과전류 보호 (O-Time delayed trip)
  2. Three-Phase Phase Loss Protection (Instant trip)
  3. Stall Protection (D-타임 + O-Time dual delay)
  4. Three-Phase Current Unbalance Protection

3.3 전기 사양

Operating Power Supply: AC 180~480V (W7 wide voltage)

출력 접점: 5A/250VAC changeover contacts (95NC, 96COM, 97아니요)

의사소통: RS485 모드버스 RTU (Exclusive to Q suffix models)

유전체 내전압: 2kV for 1 분

전력 소비: ≤250mA

3.4 환경 & 설치

작동 온도: -20℃~+60℃; 보관 온도: -30℃~+80℃

습기: 30%~85%RH, 비응축

설치: Standard 35mm DIN rail or screw fixing

주회로: Two through-core CTs (Pass L1 and L2 through protector windows)

  1. Front Panel Knobs & Indicators
  2. LOAD(에이): Motor rated current adjustment knob (5~60A)
  3. D-TIME: 시작 지연 (Prevent false tripping during startup)
  4. O-TIME: Overload trip delay
  5. Green PWR LED: Power supply normal
  6. Red TRIP LED: Fault tripping (Number of flashes indicates fault type)
  7. 다시 놓기: Manual reset button; 시험: Unit self-test button
  8. Key Differences of PQ Suffix (vs Standard 60NW7)
  9. Built-in RS485 Modbus communication: Remotely read real-time operating current, fault logs and protector status; receive remote reset commands from upper computer
  10. PCB of Q model integrates communication terminals, supporting multi-protector bus networking
  11. Ideal for automated production lines, 펌프장, central air conditioning and centralized monitoring control rooms
  12. 일반적인 애플리케이션 시나리오

380V three-phase fans, 물 펌프, 공기 압축기, belt conveyors and mixing motors

Motors with rated current 5~60A, no external current transformer required

Control cabinets requiring PLC remote motor data collection and remote fault reset

  1. 배선 지침
  2. 주회로: Run motor phase wires L1 and L2 through the two CT windows of the protector; L3 does not need to pass through
  3. Power Terminals A1/A2: Connect to AC380V control power supply
  4. 제어 회로: 96COM을 공통 터미널로 사용; wire 95NC normally closed contact in series with contactor coil (Type N opens on power loss); connect 97NO normally open contact to fault alarm indicator light
  5. RS485 Communication: A/B differential bus, daisy-chain wiring for multiple devices
  6. 문제 해결 매트릭스
결함 현상근본 원인솔루션
TRIP LED stays lit and cannot be resetContinuous overload / motor stall부하 감소, increase set current, check mechanical jamming
TRIP LED flashes twice위상 손실Inspect main circuit fuses, contactor contacts and motor wiring
No response after power-on, PWR LED 꺼짐Abnormal power supply to A1/A2Measure 380V power supply, replace the protector
No Modbus communication dataA/B wires reversed / duplicate device addressesSwap RS485 A/B polarity, set unique address for each device
  1. 동일한 시리즈의 대체 모델
  2. Non-communication version: EOCRSS-60NW7P (No RS485, 저렴한 비용)
  3. 24–240V power supply version: EOCRSS-60NS7PQ (S7 = 24~240V AC/DC)
  4. 더 높은 전류 등급: For motors over 60A, select EOCRSS-100 series with external CT