기본 제품 정보
상표: SAMWHA EOCR (슈나이더 한국)
제품 유형: EOCR-SS Series Knob-type Electronic Motor Protector (Replaces traditional thermal overload relays)
- Model Code Breakdown of EOCRSS-60NW7PQ
| 분절 | 암호 | 정의 |
| EOCRSS | 시리즈 | SS Economy Integrated Through-Core Motor Protector |
| 60 | 현재 등급 | Built-in CT, adjustable rated current: 5.0~60A, compatible with 1.5~30kW three-phase motors |
| N | 보호 모드 | Type N Fail-Safe: Contacts open and contactor trips upon protector power loss or fault; Type R does not trip when power fails |
| W7 | 전원공급장치 | W7 = Wide Voltage AC 180~480V (Suitable for 380/400/440V industrial three-phase power grids) |
| 피 | 연락처 구성 | P = Standard changeover contacts: 95(NC)/97(아니요) (1 평상시 열림 + 1 평상시 닫힘) |
| 큐 | 추가 기능 | Q = Built-in Modbus-RTU RS485 communication; supports PLC/DCS remote monitoring, real-time current reading and fault code retrieval |
핵심 기술 사양
3.1 현재의 & Time Adjustment
현재 범위: 5~60A (10:1 wide adjustment ratio)
D-타임 (Start Stall Delay): 0.2~30s adjustable to avoid false tripping caused by high motor starting current
O-타임 (Overload Trip Delay): 0.2~30s adjustable to match motor thermal characteristic curves
3.2 보호 기능
- 초과 적재 & 과전류 보호 (O-Time delayed trip)
- Three-Phase Phase Loss Protection (Instant trip)
- Stall Protection (D-타임 + O-Time dual delay)
- Three-Phase Current Unbalance Protection
3.3 전기 사양
Operating Power Supply: AC 180~480V (W7 wide voltage)
출력 접점: 5A/250VAC changeover contacts (95NC, 96COM, 97아니요)
의사소통: RS485 모드버스 RTU (Exclusive to Q suffix models)
유전체 내전압: 2kV for 1 분
전력 소비: ≤250mA
3.4 환경 & 설치
작동 온도: -20℃~+60℃; 보관 온도: -30℃~+80℃
습기: 30%~85%RH, 비응축
설치: Standard 35mm DIN rail or screw fixing
주회로: Two through-core CTs (Pass L1 and L2 through protector windows)
- Front Panel Knobs & Indicators
- LOAD(에이): Motor rated current adjustment knob (5~60A)
- D-TIME: 시작 지연 (Prevent false tripping during startup)
- O-TIME: Overload trip delay
- Green PWR LED: Power supply normal
- Red TRIP LED: Fault tripping (Number of flashes indicates fault type)
- 다시 놓기: Manual reset button; 시험: Unit self-test button
- Key Differences of PQ Suffix (vs Standard 60NW7)
- Built-in RS485 Modbus communication: Remotely read real-time operating current, fault logs and protector status; receive remote reset commands from upper computer
- PCB of Q model integrates communication terminals, supporting multi-protector bus networking
- Ideal for automated production lines, 펌프장, central air conditioning and centralized monitoring control rooms
- 일반적인 애플리케이션 시나리오
380V three-phase fans, 물 펌프, 공기 압축기, belt conveyors and mixing motors
Motors with rated current 5~60A, no external current transformer required
Control cabinets requiring PLC remote motor data collection and remote fault reset
- 배선 지침
- 주회로: Run motor phase wires L1 and L2 through the two CT windows of the protector; L3 does not need to pass through
- Power Terminals A1/A2: Connect to AC380V control power supply
- 제어 회로: 96COM을 공통 터미널로 사용; wire 95NC normally closed contact in series with contactor coil (Type N opens on power loss); connect 97NO normally open contact to fault alarm indicator light
- RS485 Communication: A/B differential bus, daisy-chain wiring for multiple devices
- 문제 해결 매트릭스
| 결함 현상 | 근본 원인 | 솔루션 |
| TRIP LED stays lit and cannot be reset | Continuous overload / motor stall | 부하 감소, increase set current, check mechanical jamming |
| TRIP LED flashes twice | 위상 손실 | Inspect main circuit fuses, contactor contacts and motor wiring |
| No response after power-on, PWR LED 꺼짐 | Abnormal power supply to A1/A2 | Measure 380V power supply, replace the protector |
| No Modbus communication data | A/B wires reversed / duplicate device addresses | Swap RS485 A/B polarity, set unique address for each device |
- 동일한 시리즈의 대체 모델
- Non-communication version: EOCRSS-60NW7P (No RS485, 저렴한 비용)
- 24–240V power supply version: EOCRSS-60NS7PQ (S7 = 24~240V AC/DC)
- 더 높은 전류 등급: For motors over 60A, select EOCRSS-100 series with external CT
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

핵심 기술 사양