ABB HPA24/612C 24kV indoor SF6 medium voltage circuit breaker

ABB HPA24/612C is a 24kV indoor SF6 medium voltage circuit breaker with rated current 630A and rated short-circuit breaking current 12.5kA. It is compatible with SafeSix switchgear and has been discontinued. The recommended replacement models are VD4-24/630-16 and HD4-24/630-16.

ABB HPA24/612C is a 24kV indoor SF6 întrerupător de circuit de medie tensiune with rated current 630A and rated short-circuit breaking current 12.5kA. It is compatible with SafeSix switchgear and has been discontinued. The recommended replacement models are VD4-24/630-16 and HD4-24/630-16.

  1. Codul modelului Explicația
Segment de codSensDescriere
HPACod seria produsuluiABB indoor SF6 medium voltage circuit breaker series, sharing the same platform with HD4 series, applicable for SafeSix switchgear
24Rated voltage level24kV (Standardul IEC, matching domestic 24kV power system)
612Combination of current and breaking capacity6 stands for 630A rated current; 12 stands for 12.5kA rated short-circuit breaking current
CStructura & configuration codeConfigurație standard, fixed type or withdrawable type (depends on switchgear type)
  1. Parametrii tehnici de bază (2026 Official Manual Version)
ParametruValoareStandard BasisObservații
Tensiune nominală (Un)24kVIEC 62271-100Max operating voltage: 27.5kV
Curent nominal (Şi)630OIEC 62271-100Continuous operation at ambient temperature 40℃
Rated Short-circuit Breaking Current (Isc)12.5celIEC 62271-1003-second short-circuit withstand
Curent nominal de rezistență de scurtă durată (Icw)12.5kA/3sIEC 62271-100Thermal stable current
Rated Peak Withstand Current (Ipk)31.5celIEC 62271-100Dynamic stable current
Mecanism de operareSpring energy storageIEC 62271-100Manual / electric operation optional
Insulating MediumSF6 gasIEC 62271-100Rated pressure: 0.45MPa @20℃
Grad de protectieIP4XIEC 60529Cabinet installation condition
Rezistenta mecanica10,000 operațiuniABB technical specificationStandard operation cycle
Rezistenta electrica100 oriIEC 62271-100Rated short-circuit breaking times
GreutateAproximativ. 85kgABB technical specificationExcluding accessories
Număr de ordine1VYN400551-XXXOfficial ABBSubject to actual configuration
  1. Cross-brand Compatibility Comparison (MV SF6 Circuit Breaker)
Modelul ABBSchneiderSiemensEatonTechnical Differences
HPA24/612CMVnex 24/630-12.53AH4 24kV/630A/12.5kAPower Xpert 24kV/630A/12.5kAABB HPA series adopts SF6 insulation and spring mechanism, fits SafeSix switchgear
Înlocuire: VD4-24/630-16HVX 24/630-163AH5 24kV/630A/16kAPower Xpert 24kV/630A/16kAVD4 adopts vacuum insulation with 30,000 mechanical operations and superior environmental performance
  1. Full HPA Series Model List
ModelTensiune nominalăCurent nominalCapacitate de rupereScenarii de aplicare
HPA12/616C12kV630O16celDistribuția de energie industrială, substation
HPA12/620C12kV630O20celIndustrie grea, fabrici mari
HPA12/1225C12kV1250O25celRegional substation, power plant
HPA12/1631C12kV1600O31.5celLarge industrial users, hub substation
HPA24/612C24kV630O12.5cel24kV power distribution system, small substation
HPA24/616C24kV630O16cel24kV power distribution system, medium-sized factories
HPA24/1220C24kV1250O20cel24kV regional substation
HPA24/1625C24kV1600O25cel24kV large industrial projects
HPA36/616C36kV630O16cel36kV power distribution system
  1. Defecte comune & Maintenance Guidelines
Fenomen de eroareCauze posibilePași de depanareSugestii de intretinere
Failure to close1. Incomplete energy storage1. Check energy storage indicator1. Test manual energy storage
2. Abnormal control voltage2. Measure control circuit voltage (DC220V/AC220V)2. Repair control circuit fault
3. Interlock not released3. Inspect mechanical interlock status3. Adjust interlock device
Failure to open1. Burnt trip coil1. Măsurați rezistența bobinei (normal: approx.100Ω)1. Replace trip coil
2. Tripping mechanism stuck2. Test manual opening operation2. Clean and lubricate tripping mechanism
3. Low SF6 gas pressure3. Check SF6 pressure gauge (≥0.4MPa)3. Refill gas or inspect air leakage
SF6 gas leakage1. Aging sealing parts1. Detect leakage with SF6 leak detector1. Replace sealing components
2. Loose connectors2. Check all connecting parts2. Fasten connectors
3. Shell crack3. Observe shell appearance3. Replace shell for severe damage
Excessive contact resistance1. Uzura de contact1. Measure contact resistance (≤50μΩ)1. Replace contacts
2. Dirty contact surface2. Inspect contact surface2. Clean contact surface
3. Loose connecting bolts3. Check bolt tightening torque3. Fasten bolts per standard torque
  1. Mediul de aplicare & Cazuri industriale

6.1 Scenarii aplicabile

24kV industrial power distribution system (chimic, metalurgie, mining industry)

Secondary substation of urban power grid

Commercial buildings and infrastructure (airport, spital, centru de date)

Renovation projects matching SafeSix switchgear

6.2 Inapplicable Scenarios

Altitude above 2000m (derating required, derating factor: 0.9 per 1000m)

Severe corrosive environment (seaside, chemical zone, special anti-corrosion treatment required)

Frequent short-circuit breaking operation (exceed 10% of rated breaking times)

Areas with strict environmental requirements (SF6 has strong greenhouse effect, VD4 vacuum circuit breaker is preferred)

6.3 Cazuri tipice de aplicare

Caz 1: 24kV Power Distribution Renovation for Chemical Plant

Aplicație: Replace old oil-minimum circuit breakers to improve power supply reliability

Soluţie: 8 sets HPA24/612C matched with ABB REF542 protection relay

Efect: Fault outage duration reduced by 80%, maintenance cost cut by 50%

Caz 2: 24kV Traction Substation for Urban Rail Transit

Aplicație: Protection for traction transformer and feeder line

Soluţie: 4 sets HPA24/612C with withdrawable structure for quick replacement

Efect: Meet high reliability requirements of rail transit, MTTR<30 minutes

  1. Conformitatea transportului aerian & Certification Information

7.1 Conformitatea transportului aerian

Hazard Classification: Mărfuri nepericuloase (fara baterie cu litiu, no explosive materials)

IATA Shipping Category: General cargo

Standard de ambalare: Comply with ISTA 3A standard to avoid SF6 seal damage caused by transportation vibration

Nota: Close SF6 inflation valve during transportation to prevent gas leakage

7.2 Documente de certificare

CE Certificate No.: 1YHA000091 (universal for HPA series)

IEC Standard Approval: IEC 62271-100:2017

China National Standard Approval: GB 1984-2014 High-voltage Alternating Current Circuit-breakers

Environmental Certification: SF6 gas recovery complies with IEC 62271-4

  1. Selectarea modelului & Replacement Suggestions
  2. Confirmarea modelului: HPA series is fully discontinued. It is recommended to contact ABB customer service 400-810-8888 and provide nameplate photos to confirm detailed configuration.
  3. Soluții de înlocuire

First choice: VD4-24/630-16 (vacuum type, 30,000 operatii mecanice, SF6-free eco-friendly design)

Alternative choice: HD4-24/630-16 (SF6 type, same platform as HPA, direct replacement without switchgear modification)

  1. Spare Parts Procurement: Limited stock of HPA series spare parts. Pre-order via authorized ABB distributors in advance or plan overall equipment upgrading.

ABB HPA24/612C is a 24kV indoor SF6 medium voltage circuit breaker with rated current 630A and rated short-circuit breaking current 12.5kA. It is compatible with SafeSix switchgear and has been discontinued. The recommended replacement models are VD4-24/630-16 and HD4-24/630-16.