ABB F204B63-2CSF204592R1630

This is a ABB F200 Series 4-pole Type B Residual Current Circuit Breaker (RCCB) with a rated current of 63A and a rated residual operating current of 30mA. This model is obsolete. The original manufacturer replacement part number is 2CSF204568R1630 (F204B-63/0.03-4TE). It is designed for industrial applications equipped with frequency converters, UPS and other devices, ...

  • Détails du produit

C'est un ABB F200 Series 4-pole Type B Disjoncteur à courant résiduel (RCCB) with a rated current of 63A and a rated residual operating current of 30mA. This model is obsolete. The original manufacturer replacement part number is 2CSF204568R1630 (F204B-63/0.03-4TE). It is designed for industrial applications equipped with frequency converters, UPS and other devices, and provides protection against smooth DC leakage current.

  1. Explication du code modèle
Segment de modèleDéfinitionDescription détaillée
F204Modèle de baseF200 Series, 4-pole residual current circuit breaker
BType de courant résiduelTapez B, capable of detecting AC, pulsating DC and smooth DC residual current (0-1000HZ)
63Courant opérationnel nominal63UN, continuous current rating
0.03Courant de fonctionnement résiduel nominal0.03A = 30mA, high-sensitivity protection against direct human contact
2CSF204592R1630Code de commandeUnique official ABB identification code for purchasing and traceability
4LEType de montageStandard DIN rail mounting with 4-pole terminals (marked on partial versions)
  1. Principales spécifications techniques
CatégorieDonnées techniquesRemarques
Caractéristiques de base
Type de produitDisjoncteur à courant résiduel (RCCB)No overload or short-circuit protection; must be used with MCB
SérieSystem pro M compact® F200ABB modular power distribution product line
Poteaux4P. (L1, L2, L3, N)Protection for 3-phase 4-wire systems
Tension nominale400V et (50/60HZ)Plage de tension de fonctionnement: 380-415V
Courant nominal (Dans)63UNCompliant with IEC/EN 61008-1
Courant de fonctionnement résiduel nominal (JeΔn)30mAType instantané (no time delay)
Type de courant résiduelTapez BComprehensive protection against AC, pulsating DC and smooth DC leakage current
Paramètres de performances
Capacité de coupure (IΔm)3leBreaking capacity under rated conditions
Operating Time≤0.04s @ IΔn=30mAMeets requirements for rapid personal safety protection
Rated Residual Non-operating Current (IΔno)15mANo tripping below this value to avoid nuisance tripping
Bouton de testIntégréFor regular functional testing
Caractéristiques physiques
Dimensions (L × H × P)70mm × 85mm × 60mmConception modulaire standard, occupies 4 module units
Montage35mm rail DINConforme à la norme EN 50022
Type de borneBi-directional cylindrical terminalsFacilitates cable connection and enhances safety
PoidsEnviron. 360gWeight per unit
Environnement & Certifications
Température de fonctionnement-25°C ~ +55°CPerformance may be affected beyond this range
Température de stockage-40°C ~ +85°C
Humidité5% ~ 95% (sans condensation)
Protection contre la pénétrationIP20Finger-proof, not suitable for outdoor use
CertificationsCEI/EN 61008-1, CEI/EN 61008-2-1Certifié CE, complies with international safety standards
Statut du cycle de vie
StatutObsoleteStock still available via some distributors
Date d'arrêtJun-24Official record
  1. Liste complète des modèles (F204 Type B)
ModèleCode de commandeCourant nominalRated Residual CurrentCaractéristiques
F204 B-25/0.032CSF204592R125025UN30mA4-pole Type B, basic model
F204 B-40/0.032CSF204592R140040UN30mA4-pole Type B, medium current
F204 B-63/0.032CSF204592R163063UN30mA4-pole Type B, standard industrial model
F204 B-63/0.12CSF204592R263063UN100mA4-pole Type B, higher sensitivity
F204 B-63/0.32CSF204592R363063UN300mA4-pole Type B, equipment protection
F204 B-63/0.52CSF204592R463063UN500mA4-pole Type B, system protection
F204 B-80/0.032CSF204592R180080UN30mA4-pole Type B, courant élevé
F204 B-100/0.032CSF204592R1100100UN30mA4-pole Type B, extra high current
F204 B-125/0.032CSF204592R1125125UN30mA4-pole Type B, maximum current
F204 B-63/0.03-4TE2CSF204568R163063UN30mAReplacement model, 4-pole Type B, standard terminals
  1. Solutions de remplacement & Équivalents multimarques

4.1 Original Manufacturer Replacements

Modèle originalModèle de remplacementRaison du remplacementCompatibilité
F204 B-63/0.03 (2CSF204592R1630)F204 B-63/0.03-4TE (2CSF204568R1630)Product upgrade with optimized terminal designEntièrement compatible, remplacement direct
DDA204 B-63/0.03 AP-R (2CSB204592R1630)FI-Block series, integrated designIdentical mounting dimensions and functions

4.2 Cross-Brand Compatible Replacements

MarqueModèleTechnical Matching RateRemarques
SchneideriC60H RCCB 4P 63A 30mA Type B95%Dimensionally compatible, equivalent performance
Siemens5SU1356-6KK6390%Slight difference in tripping characteristics
Legrand4102 63 03 B90%Different wiring terminals
Chint (Chine)NXBLE-400/4P 63A 30mA Type B85%Cost-effective with complete certifications
  1. Environnements d'applications & Cas typiques

5.1 Applications recommandées

Systèmes d'automatisation industrielle: Frequency converters, servomoteurs, Armoires automates; protects against smooth DC leakage current.

Équipement médical: Operating rooms, ICU devices; provides top-level leakage protection.

Centres de données: UPS systems, server cabinets; prevents nuisance tripping caused by power fluctuation.

Renewable Energy: Onduleurs photovoltaïques, systèmes de stockage d'énergie; protects DC side leakage.

Bâtiments commerciaux: Kitchen equipment, central air conditioning, elevator control systems; protection for 3-phase loads.

5.2 Applications non recommandées

Pure residential single-phase loads: Type B is overqualified; Type AC is sufficient.

Outdoor humid environments: IP20 rating is inadequate; additional enclosure protection required.

Zones dangereuses explosives: Explosion-proof products must be used.

Applications requiring overload/short-circuit protection: This unit only provides leakage protection and shall be used together with MCB.

5.3 Cas d'application typiques

Cas 1: Automotive Manufacturing Workshop

Équipement: Robotic welding systems, converter-driven production lines

Issue: Frequent nuisance tripping of conventional Type AC RCCBs affected production.

Solution: Install F204 B-63/0.03 to protect against smooth DC leakage generated by converters.

Résultat: Nuisance tripping rate reduced by 90%, production efficiency improved by 15%.

Cas 2: Hospital Operating Room

Équipement: Anesthesia machines, patient monitors, surgical lights

Requirements: Highest safety level, zero nuisance tripping and fast response.

Solution: Adopt F204 B-63/0.03 combined with S204-B63 MCB.

Résultat: Complies with medical equipment safety standards and ensures operational safety.

  1. Dépannage & Maintenance Manual

6.1 Défauts courants & Solutions

Phénomène de défautCauses possiblesÉtapes de dépannage
Déclenchements fréquents1. Actual circuit leakage1. Test circuit insulation with megohmmeter after power off
2. DC leakage from loads2. Verify if loads require Type B RCCB
3. Product aging3. Check production date; replace if service life exceeds 10 années
4. Bornes de câblage desserrées4. Retighten wiring terminals
Failure to trip1. Damaged test button1. Replace test button assembly
2. Internal trip mechanism fault2. Send for repair or replace the unit
3. Mauvais câblage (neutral wire disconnected)3. Check wiring and ensure neutral wire is properly connected
Cannot be reset1. Mechanical lock failure1. Manually reset after power off; replace if failed
2. Persistent leakage2. Eliminate leakage fault before resetting
3. Température ambiante trop élevée3. Improve ventilation and lower ambient temperature
Indicator light off1. Damaged indicator lamp1. Replace indicator lamp
2. Défaut du circuit interne2. Send for repair or replace the unit

6.2 Maintenance Procedures

  1. Routine Inspection (Mensuel)

Visually inspect for damage or discoloration.

Press test button to confirm normal tripping and reset.

Check terminals for looseness and overheating marks.

  1. Entretien périodique (Annuellement)

Clean unit surface with dry soft cloth after power cut.

Check firmness of DIN rail mounting.

Measure insulation resistance (≥1 MΩ).

Record test results.

  1. Cycle de remplacement

Normal operating conditions: 10 années

Environnements difficiles (haute température / humidité élevée): 5~7 years

Frequent tripping conditions: 3~5 years

6.3 Quick Diagnosis Tips

Type B RCCB handles DC leakage well.

Check wiring first for frequent tripping; load type matters most.

Replace unit immediately if test button malfunctions.

Power off and clear faults before resetting.

Replace after 10 years for reliable safety.

  1. Lignes directrices de sélection
  2. Residual Current Type Selection: Choose Type B for systems with converters, UPS or medical devices; Type AC for general lighting and sockets; Type A for pulsating DC loads.
  3. Sélection du courant nominal: Courant nominal ≥ 1.2 times total load current. 63A is suitable for most industrial control cabinets.
  4. Residual Current Rating Selection: 30mA for personal protection; 100~300mA for equipment protection; 500mA~1A for system protection.
  5. Sélection des pôles: 2P for single-phase systems; 3P for 3-phase 3-wire systems; 4P. (with neutral wire) for 3-phase 4-wire systems.
  6. Replacement Principle: Prioritize upgraded models from the same series for obsolete products to guarantee identical dimensions and performance.