Schneider Marine-grade Circuit Breaker 24338 - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 Schneider Marine-grade Circuit Breaker 24338 - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

disjoncteur/

Schneider Marine-grade Circuit Breaker 24338

Full Range of Marine Classification Society Certifications: Approved by major global marine classification societies, complying with regulatory requirements for various vessels and offshore engineering equipment. Large plage de températures de fonctionnement: -30°C à +60°C, suitable for extreme temperature variations in marine environments. Model Code Explanation Segment Code Description Product Range C60 Miniature Circuit Breaker of Multi9 series ...

  • Détails du produit

Full Range of Marine Classification Society Certifications: Approved by major global marine classification societies, complying with regulatory requirements for various vessels and offshore engineering equipment.

Large plage de températures de fonctionnement: -30°C à +60°C, suitable for extreme temperature variations in marine environments.

  1. Explication du code modèle
SegmentCodeDescription
Product RangeC60Disjoncteur miniature of Multi9 series
Capacité de coupureNPouvoir de coupure standard (10le, 400V et)
Nombre de pôles2P.2 poteaux (2 poteaux protégés)
Courant nominal20UNCourant de fonctionnement nominal: 20 Amperes
Courbe de déplacementCCourbe C (Trips at 8~12 times rated current, for combined lighting and motor loads)
Numéro de commande24338Original standard order number of Schneider (equivalent to M9F11220)

Modèle complet: C60N 2P C20A (Official Standard Model)

Numéro de commande: 24338 (M9F11220)

  1. Principales spécifications techniques
Catégorie de paramètreSpécifications détaillées
Paramètres de base2-pole miniature circuit breaker, C-type trip curve, rated current 20A
Tension nominaleCA: 400V (50/60HZ); CC: 125V
Capacité de coupure10kA @ 400V AC (conforme à la CEI 60947-2)
Caractéristique du voyageCourbe C: 8.2In ±20% (In=20A, tripping range: 164~200A)
Endurance mécanique20,000 cycles de fonctionnement
Endurance électrique10,000 operating cycles at rated current
Conditions ambiantesTempérature: -30°C ~ +60°C; Humidité: ≤95% (sans condensation)
Montage35mm Montage sur rail DIN (conforme à la norme EN 60715)
Dimensions & PoidsHauteur: 85mm; Largeur: 45mm; Profondeur: 60mm; Poids: environ. 180g
Degré de protectionIP20 (conforme à la CEI 60529)
Marine CertificationsCertified by 9 major classification societies including ABS, BV, DNV, GL, LRS, RINA, CCS, KRS
Standard ApprovalsCEI 60947-2, FR 14048.2, CE, CCC, etc..
  1. Marine Features & Scénarios d'application

3.1 Core Advantages for Marine Use

Full Marine Classification Certifications: Complies with standards of mainstream global marine classification societies for vessels and offshore facilities.

Large adaptation à la température: Operates stably from -30°C to +60°C to cope with harsh marine temperature conditions.

Vibration & Résistance aux chocs: Conforme à la CEI 60068-2-6 (Vibration) et CEI 60068-2-27 (Choc), applicable to rough working conditions during vessel navigation.

Corrosion Resistance: Special salt-fog resistant housing material extends service life in marine environments.

3.2 Scénarios applicables

Ship Power Systems: Protection for main switchboards, emergency switchboards, lighting and ventilation systems.

Offshore Platforms: Power distribution and protection for drilling platforms, offshore wind farms, FPSO and other facilities.

Marine Auxiliary Equipment: Control circuit protection for pumps, compresseurs, les fans, navigation equipment, etc..

Yachts & Small Vessels: Meets safety standards for recreational marine craft.

3.3 Scénarios non recommandés

High Short-circuit Current Environment: Locations with short-circuit current exceeding 10kA (C60H series with 15kA breaking capacity is recommended).

High-voltage DC Systems: DC circuits over 125V (special DC circuit breakers required).

Frequent Cycling Circuits: Operations over 10 cycles per minute (use contactors with protective devices instead).

  1. Remplacement & Upgrade Solutions

4.1 Original Schneider Replacements

Modèle originalModèle de remplacementRaison du remplacementCompatibilité
24338 (C60N 2P C20A)A9F44220 (iC60N 2P C20A)Upgraded Acti9 series, breaking capacity increased to 15kADimensions de montage identiques, remplacement direct
24338 (C60N 2P C20A)M9F11220 (C60N 2P C20A)Official original model, fully identical to 24338100% compatible
24338 (C60N 2P C20A)C60H 2P C20ABreaking capacity upgraded to 15kA for severe working conditionsDimensions de montage identiques, enhanced breaking performance

4.2 Cross-brand Replacements

MarqueModèle de remplacementPrincipales différencesApplicability
ABBS202-C2010kA pouvoir de coupure, Courbe C, 2P 20ASame mounting size, remplacement direct
Siemens5SY6220-7CC10kA pouvoir de coupure, Courbe C, 2P 20ASlight difference in auxiliary functions, consistent basic protection
ChintDZ47-63 2P C20Domestic alternative with cost advantage, 6kA pouvoir de coupureFor non-critical marine equipment
  1. Dépannage & Directives d'entretien

5.1 Diagnostic de panne courant

Phénomène de défautCauses possiblesSolutions
Déclenchements fréquents1. Overloaded load; 2. Circuit short circuit; 3. Mismatched trip curve1. Check if load current exceeds rated value; 2. Inspect circuit insulation; 3. Verify suitability of C-curve for the load
Failure to trip1. Damaged tripping mechanism; 2. Current below trip threshold; 3. Câblage incorrect1. Inspect mechanical condition of tripping mechanism; 2. Measure actual operating current; 3. Confirm correct wiring (line in, load out)
Severe overheating1. Bornes lâches; 2. Oxidized contacts; 3. Excess ambient temperature1. Retighten wiring terminals; 2. Nettoyer les contacts; 3. Improve ventilation and heat dissipation
Bourrage mécanique1. Foreign object ingress; 2. Worn operating mechanism; 3. Loose parts caused by vibration1. Power off and remove foreign objects; 2. Inspect operating mechanism; 3. Reinforce mounting fixtures

5.2 Maintenance Recommendations for Marine Environments

Article d'entretienFaire du véloOpération
Inspection visuelleMensuelCheck for salt-fog corrosion, cracks and loose components
Insulation Resistance TestTrimestrielUse megohmmeter to test insulation resistance (value shall be higher than 1MΩ)
Contactez-nousSemestriellementCheck contacts for ablation and oxidation; measure contact resistance
Test de fonctionnementAnnuellementSimulate overload and short circuit to verify normal tripping performance
NettoyageAnnuellementRemove internal dust with dry compressed air; avoid chemical detergents
  1. Guide de sélection & Conformité du fret aérien

Mnemonic for Selection

C60N two-pole, twenty ampere C-curve,

Nine marine approvals, ten kiloamp breaking,

Replace with iC60 for higher capacity,

Safe for marine use, DIN rail mount ready.

Conformité du fret aérien

Transport Classification: Marchandises non dangereuses. No built-in lithium batteries or supercapacitors, compliant with IATA regulations.

Exigence d'emballage: Individual packaging to prevent damage from vibration during transit. Original moisture-proof packaging is recommended.

Documents de certification: Carry copies of marine classification certificates for customs and inspection.

Full Specification Comparison Table for Schneider C60 Series Marine Miniature Circuit Breakers

This table provides a detailed comparison of core specifications for C60N / C60H marine series (y compris 24338: C60N 2P C20A), covering commonly used pole counts (1P/2P/3P/4P) and current ratings (16A/20A/25A/32A/40A/50A/63A) for bulk selection.

  1. General Specification List (Marine C-curve)
ModèleNuméro de commandePoteauxCourant nominalCapacité de coupureLargeurPoidsMarine CertificationsModèle de remplacement (iC60 Series)
C60N 1P C16AM9F111161P.16UN10le18mm90g9 Classification SocietiesA9F74116
C60N 1P C20AM9F111201P.20UN10le18mm90g9 Classification SocietiesA9F74120
C60N 1P C25AM9F111251P.25UN10le18mm90g9 Classification SocietiesA9F74125
C60N 1P C32AM9F111321P.32UN10le18mm90g9 Classification SocietiesA9F74132
C60N 2P C16AM9F112162P.16UN10le36mm180g9 Classification SocietiesA9F74216
C60N 2P C20A24338 / M9F112202P.20UN10le36mm180g9 Classification SocietiesA9F74220
C60N 2P C25AM9F112252P.25UN10le36mm180g9 Classification SocietiesA9F74225
C60N 2P C32AM9F112322P.32UN10le36mm180g9 Classification SocietiesA9F74232
C60N 3P C16AM9F113163P.16UN10le54mm270g9 Classification SocietiesA9F74316
C60N 3P C20AM9F113203P.20UN10le54mm270g9 Classification SocietiesA9F74320
C60N 3P C25AM9F113253P.25UN10le54mm270g9 Classification SocietiesA9F74325
C60N 3P C32AM9F113323P.32UN10le54mm270g9 Classification SocietiesA9F74332
C60N 4P C16AM9F114164P.16UN10le72mm360g9 Classification SocietiesA9F74416
C60N 4P C20AM9F114204P.20UN10le72mm360g9 Classification SocietiesA9F74420
C60H 2P C20AM9F142202P.20UN15le36mm180g9 Classification SocietiesA9F84220
C60H 3P C20AM9F143203P.20UN15le54mm270g9 Classification SocietiesA9F84320
  1. Comparison of Breaking Capacity & Caractéristiques du voyage
SérieCapacité de coupureCourbe de déplacementScénarios d'applicationMax Rated CurrentNiveau de prix
C60N10kA @ 400V ACB / C / DGeneral ship power systems, combined lighting & motor loads63UNStandard
C60H15kA @ 400V ACB / C / DShip systems with high short-circuit current, par exemple. main switchboards63UNStandard +15%
iC60N15kA @ 400V ACB / C / DUpgraded replacement for C60N with improved performance63UNStandard +20%
iC60H30kA @ 400V ACB / C / DHigh-standard marine systems and offshore platforms63UNStandard +30%

Trip Curve Description

B-curve: Trips at 3~5 times rated current, for pure resistive loads (éclairage)

Courbe C: Trips at 8~12 times rated current, for combined lighting and motor loads (le plus largement utilisé)

D-curve: Trips at 12~14 times rated current, for inductive loads such as motors and transformers

  1. Detailed Comparison between 24338 (C60N 2P C20A) & Modèles courants

3.1 Same Poles, Different Current Ratings (2P.)

ModèleCourant nominalTrip Current RangeApplicable LoadsDifférence par rapport à 24338
C60N 2P C16A16UN128~192AÉclairage & motor loads below 16A20% lower current, more sensitive protection
C60N 2P C20A (24338)20UN164~200ACombined loads below 20AConfiguration standard
C60N 2P C25A25UN205~300ACombined loads of 20~25A25% higher current, larger load capacity
C60N 2P C32A32UN262~384ACombined loads of 25~32A60% higher current, for higher-power equipment

3.2 Same Current, Different Pole Counts (20UN)

ModèlePoteauxLargeurScénarios d'applicationDifférence par rapport à 24338
C60N 1P C20A1P.18mmSingle-phase lighting & circuits de priseHalf width, only live pole protected
C60N 2P C20A (24338)2P.36mmSingle-phase motors & équipement, line and neutral disconnected simultaneouslyConfiguration standard, protection complète
C60N 3P C20A3P.54mmThree-phase motors & équipement, 380Systèmes V50% wider, for three-phase circuits
C60N 4P C20A4P.72mmThree-phase four-wire systems with neutral protectionDouble width, for circuits requiring neutral pole protection

3.3 Same Specification, Different Breaking Capacity (2P 20A C)

ModèleCapacité de coupureEnvironnement d'applicationDifférence de prixDifférence par rapport à 24338
C60N 2P C20A (24338)10leGeneral ship systemsStandardConfiguration standard
C60H 2P C20A15leSystems with high short-circuit current15%50% pouvoir de coupure plus élevé
iC60N 2P C20A15leUpgraded replacement solution20%New generation product with longer service life
iC60H 2P C20A30leOffshore engineering platforms30%200% pouvoir de coupure plus élevé
  1. Selection Reference Table for Marine Applications
Type de chargeRecommended Trip CurveRecommended Breaking CapacityRecommended PolesReference Current
Ship Lighting SystemBC60N (10le)1P. / 2P.6UN / 10UN / 16UN
Ventilateurs & Pump MotorsCC60N (10le)3P.16UN / 20UN / 25UN
Compresseurs & Air-conditioning UnitsCC60H (15le)3P.25UN / 32UN / 40UN
Navigation & Équipement de communicationBC60N (10le)1P. / 2P.6UN / 10UN
Branches of Main SwitchboardCC60H (15le)3P. / 4P.32UN / 40UN / 50UN
Emergency Power SystemDC60H (15le)3P.40UN / 50UN / 63UN
  1. Notes for Bulk Selection
  2. Marine Certifications: All C60 marine models are certified by 9 major classification societies including ABS, BV, DNV, GL, LRS, RINA, CCS and KRS, available for global use.
  3. Compatibilité de montage

All models adopt 35mm DIN rail mounting (conforme à la norme EN 60715).

Width varies by pole count: 1P=18mm, 2P=36mm, 3P=54mm, 4P=72mm.

Uniform dimensions: Height 85mm, Depth 60mm.

  1. Replacement Strategy

Short-term replacement: Prioritize identical models from the same series (par exemple. 24338 = M9F11220).

Long-term upgrade: Choose iC60N series (par exemple. A9F74220 for 24338) with breaking capacity upgraded to 15kA.

Severe working conditions: Select C60H / iC60H series with 15~30kA breaking capacity.

  1. Adaptabilité environnementale

Température de fonctionnement: -30°C ~ +60°C, suitable for extreme marine environments.

Vibration & shock resistance: Conforme à la CEI 60068-2-6 et CEI 60068-2-27.

Salt-fog resistant design: Special housing material extends service life in marine conditions.

  1. Selection Mnemonic for C60 Marine Series

Marine C60N holds nine approvals,

Two-pole 20A with C-curve set,

iC60 upgrades breaking power,

Match poles and current for your load hour,

Wide temp and anti-vibration, ideal for marine power.