Numéro de commande: 2903154
Contact Phénix TRIO POWER 2nd-generation three-phase DIN rail switching alimentation with Push-in spring terminals. Designed for powering PLCs, sensors and actuators inside electrical control cabinets. Widely used in machine manufacturing, lignes de production automatisées, HVAC and hoisting equipment.
Le code 2901354 often appears in industry documents as shorthand; the complete official part number is 2903154.
✅ Définition du modèle
TRIO: TRIO POWER series industrial power supply
PS: Alimentation
2G: 2ème génération
3CA: 3-phase AC input
24CC: 24Sortie V CC
10: Rated output current 10A
📌 Key Technical Specifications
Saisir
Noté: 3×400~500V AC; capable of emergency operation with 2×400~500V AC two-phase supply
Plage de fonctionnement: 3×320~575V AC
Fréquence: 50/60Hz
Courant d'entrée: 3×0.6A @400VAC
Sortir
Noté: 24V DC /10A (240W)
Adjustable output: 24~28 V CC
Boost dynamique: 15Un pour 5 secondes (pour gérer les charges d'appel des moteurs et des condensateurs)
Ondulation & bruit: ≤50 mVpp
Protection contre les surtensions OVP: Sortie bloquée ≤30 V DC
Mécanique & Environnemental
Montage: Rail DIN 35 mm
Dimensions (L × H × P): 42 ×130 ×160 mm
Câblage: Bornes à ressort sans vis enfichables
Température de fonctionnement: -25℃ ~ +70℃; déclassement de 2,5 %/K au-dessus de 60 ℃
Efficacité: >92%
Fonctionnement parallèle: Prend en charge la connexion parallèle pour l'extension de capacité et la redondance; connexion en série pour augmenter la tension
Protections: Surintensité, court-circuit, surchauffe, surtension de sortie
Signal: Contact d'alarme relais (Signal DC-OK)
📋Attestation & Applications
Normes: EN61010, UL, CE, Très basse tension de protection PELV
Applications typiques: Lignes de production automatisées, machines d'emballage, systèmes de convoyeurs, 24Alimentation V pour armoires de commande alimentant les automates, Modules d'entrée/sortie, capteurs et électrovannes
MTBF élevé, adapté pour 24/7 exploitation industrielle continue
⚠️ Sélection & Notes de remplacement
- Distinction du modèle: 2903154 est triphasé 3AC; la version monophasée 1AC est 2903149, ne les mélangez pas
- Alternative nationale: Mean Well SDR-240-24, Delta DRP-240-24 (note: pas de capacité d'amplification dynamique pour le courant d'appel)
- Solution de redondance: Lors de la mise en parallèle de deux 2903154 unités, utiliser un module de redondance tel que QUINT-DIODE
- Installation: Maintenir un dégagement vertical ≥ 50 mm en haut et en bas pour la dissipation thermique; units can be mounted side-by-side with zero horizontal clearance
🛠️ Guide de dépannage
POWER LED off: Check 3-phase L1/L2/L3 mains supply; loss of any phase may prevent startup; verify PE earth connection
Chute de tension de sortie / insufficient load capacity: Prioritize checking loose terminals, low input voltage and high-temperature derating
OK contact open: Surintensité de sortie / short circuit or internal overtemperature protection. Disconnect load and retest
Tripping on power-up due to inrush: Utilize boost feature and evaluate switching surge current
📦 HS Code for Export
8504401400 (Convertisseurs statiques, industrial switching power supply, for customs reference only, subject to local customs determination)
TRIO-PS-2G/3AC/24DC/10 (Numéro de commande. 2903154)
Efficacité: >92%
Conditions d'essai: 400Entrée V CA, full rated load
Additional Power Consumption Parameters
Consommation d'énergie à vide: <1.1 W
Power loss at rated load: <22 W
Note: This value is the nominal figure from Phoenix Contact official datasheet. Actual efficiency under light load (20%~50% load) will be slightly lower than the 92% full-load rating.
TRIO-PS-2G/3AC/24DC/10 (Numéro de commande. 2903154)
Dimensions hors tout (L × H × P): 42 mm × 130 mm × 160 mm
📌 Installation Clearance (Critical for cabinet layout)
Horizontal sides: Zero gap side-by-side mounting allowed at ambient ≤40℃; reserve 10mm side clearance when temperature approaches 70℃
Verticale: ≥50mm clearance at top and bottom (obligatoire)
Rail de montage: Standard NS35 DIN rail (EN60715)
Poids
Environ. 1.1kilos
Phoenix Contact TRIO-PS-2G Series Full Model List (TRIO POWER 2nd Generation, Bornes push-in)
Series common features: Montage sur rail DIN35, dynamic Boost (1.5×rated current for 5s), DC-OK relay alarm, parallel redundancy support, -25~+70℃, déclassement de 2,5 %/K au-dessus de 60 ℃
1-phase Input 1AC (100~240 VCA)|24VDC Output
| Modèle | Numéro de commande. | Note de sortie | Dimension W×H×D(mm) |
| TRIO-PS-2G/1AC/24DC/3/C2LPS | 2903147 | 24V 3A /72W | 30 ×130 ×115 |
| TRIO-PS-2G/1AC/24DC/5 | 2903148 | 24V 5A /120W | 36 ×130 ×115 |
| TRIO-PS-2G/1AC/24DC/10 | 2903149 | 24V 10A /240W | 42 ×130 ×160 |
| TRIO-PS-2G/1AC/24DC/20 | 2903151 | 24V 20A /480W | 65 ×130 ×160 |
3-phase Input 3AC (3×320~575VAC, rated at 3×400VAC)|24VDC Output (Your target model group)
| Modèle | Numéro de commande. | Note de sortie | Dimension W×H×D(mm) |
| TRIO-PS-2G/3AC/24DC/5 | 2903153 | 24V 5A /120W | 36 ×130 ×115 |
| TRIO-PS-2G/3AC/24DC/10 | 2903154 | 24V 10A /240W | 42 ×130 ×160 |
| TRIO-PS-2G/3AC/24DC/20 | 2903155 | 24V 20A /480W | 65 ×130 ×160 |
| TRIO-PS-2G/3AC/24DC/40 | 2903156 | 24V40A /960W | 120 ×130 ×160 |
1-Phase Entrée 1AC ~ 48VDC Sortie
| Modèle | Numéro de commande. | Note de sortie | Dimension W×H×D(mm) |
| TRIO-PS-2G/1AC/48DC/5 | 2903159 | 48V5A /240W | 42 ×130 ×160 |
| TRIO-PS-2G/1AC/48DC/10 | 2903160 | 48V10A /480W | 65 ×130 ×160 |
- Accessoires assortis courants (Pour l'intégration en armoire)
- QUINT-DIODE/12-24DC/20 Module de diodes de redondance pour double redondance d'alimentation
- Disjoncteur électronique CBM E4 24DC/0,5-10A NO-R 4 canaux 24V (2905743)
- Disjoncteur électronique CBM E8 24DC/0,5-10A NO-R 8 canaux (2905744)
✅ Directives de sélection clés
- Suffixe C2LPS: Uniquement disponible pour la variante monophasée 3A avec capacité SIL; non requis pour les projets d'automatisation standard
- 3Les modèles triphasés AC peuvent fonctionner sur deux phases (L1/L2 uniquement)
- Référence de largeur: 3A=30mm; 5A=36mm; 10A=42mm; 20A=65mm; 40A=120mm, la disposition des armoires dépend principalement de la largeur
Liste des certifications de la série Phoenix Contact TRIO-PS-2G (Y compris TRIO-PS-2G/3AC/24DC/10, N° de commande 2903154)
Tous les modèles de cette série partagent le même package de certification. Seul le modèle avec suffixe C2LPS a une capacité SIL0 supplémentaire; les modèles standards sont SIL=0
✅Certifications mondiales
- CE (UE)
Directive Basse Tension LVD 2014/35/UE
Directive CEM 2014/30/UE
- UL / cULus (Homologué UL)
UL508 (Équipement de contrôle industriel)
UL60950-1 (Sécurité des technologies de l'information)
ANSI/ISA-12.12.01, Classe I Division II Groupes A/B/C/D (adapté aux zones dangereuses d'Amérique du Nord)
- Certificat IECEE CB (Régime CB, base pour la conversion des certifications multi-pays)
- Certification de l'Union douanière de la CAE (Russie, Biélorussie, Kazakhstan et autres marchés de l'UEE)
- Certificat marin DNV GL (Convient aux armoires de commande de navires et offshore)
- BIS (Licence BIS pour le marché indien)
✅ Conformité environnementale
RoHS (UE)
ATTEINDRE
DEEE conforme à la directive sur les déchets d'équipements électriques et électroniques
✅ Sécurité & Normes fonctionnelles (Normes ≠ Certificats; spécifications de conformité des produits)
CEI 60950-1: Très basse tension de sécurité SELV
DANS 50178: Très basse tension de protection PELV
DANS 60204-1: Sécurité des équipements électriques des machines (largement utilisé pour les machines)
DANS 50121-4: Norme CEM ferroviaire
CEI 61508: SIL 0 (Modèles standards de cette série; TRIO-PS-2G/1AC/24DC/3/C2LPS est spécifiquement marqué sécurité fonctionnelle SIL0)
Inflammabilité du boîtier: UL94V0
✅ Normes de compatibilité électromagnétique CEM
DANS 61000-6-1 / 6-2: Immunité (Résidentiel / environnements industriels)
DANS 61000-6-3 / 6-4: Rayonné & émissions conduites
DANS 61000-3-2: Limites de courant harmonique
📌 Remarques sur la sélection
- Projets nationaux: Pas de certificat CCC, n'entre pas dans le champ d'application obligatoire des 3C. CE pour l'exportation vers l'UE, UL pour l'Amérique du Nord, EAC pour la Russie/Asie centrale, DNV pour les projets marins.
- Niveau SIL: La norme TRIO-PS-2G ne peut pas être utilisée pour les boucles de sécurité SIL1 et supérieures.. Si un niveau SIL plus élevé est requis, sélectionnez les alimentations électriques classées SIL de la série QUINT.
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur
















NH42-63-318x560.png)